Heat & Glo LifeStyle AT-ZC manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 28 pages
- 0.84 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Indoor Fireplace
Heat & Glo LifeStyle ST-CFL-24LP
21 pages 1.1 mb -
Indoor Fireplace
Heat & Glo LifeStyle 8000TVC
31 pages 1.39 mb -
Indoor Fireplace
Heat & Glo LifeStyle 8000CMOD-IPI
71 pages 3.97 mb -
Indoor Fireplace
Heat & Glo LifeStyle AT-ZC
28 pages 0.84 mb -
Indoor Fireplace
Heat & Glo LifeStyle 6000 ARCH
46 pages 1.33 mb -
Indoor Fireplace
Heat & Glo LifeStyle 8000TVD
20 pages 0.54 mb -
Indoor Fireplace
Heat & Glo LifeStyle BE-41IPIC
69 pages 4.44 mb -
Indoor Fireplace
Heat & Glo LifeStyle RCOR-HV-IPI
45 pages 3.14 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Heat & Glo LifeStyle AT-ZC. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Heat & Glo LifeStyle AT-ZC ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Heat & Glo LifeStyle AT-ZC décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Heat & Glo LifeStyle AT-ZC devrait contenir:
- informations sur les caractéristiques techniques du dispositif Heat & Glo LifeStyle AT-ZC
- nom du fabricant et année de fabrication Heat & Glo LifeStyle AT-ZC
- instructions d'utilisation, de réglage et d’entretien de l'équipement Heat & Glo LifeStyle AT-ZC
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Heat & Glo LifeStyle AT-ZC ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Heat & Glo LifeStyle AT-ZC et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Heat & Glo LifeStyle en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Heat & Glo LifeStyle AT-ZC, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Heat & Glo LifeStyle AT-ZC, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Heat & Glo LifeStyle AT-ZC. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Heat-N-Glo Fireplace Model: A T -ZC Patents Pending Installers Guide W ARNING: IMPROPER INST ALLA TION, ADJUSTMENT , AL TERA TION, SER VICE OR MAINTENANCE CAN CAUSE INJUR Y OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSIST ANCE OR ADDITIONAL INFORMA TION CONSUL T A QUALIFIED INST ALLER, SER VICE AGENCY , OR THE GAS SUPPLIER. Underwriters Laborat[...]
-
Page 2
i SAFETY AND W ARNING INFORMA TION READ and UNDERST AND all instructions carefully before starting the installation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty . Prior to the first firing of the fireplace, READ the Using Y our Fireplace section of the Owners Guide . DO NOT USE t[...]
-
Page 3
ii Safety and W arning Information .................... i Section 1: Approvals and Codes ................ 1 Approval Listings and Codes .................................. 1 Appliance Certification ............................................ 1 Installation Codes ................................................... 1 High Altitude Installations .....[...]
-
Page 4
1 Approval Listings and Codes Appliance Certification The Heat-N-Glo models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. CERTIFICA TION MODEL LABORA TO R Y TYPE S T ANDARD A T -ZC Underwriters Direct V ent ANSI Z21.44CGA2.19/IR#41 Laboratories W all Furnace Installation[...]
-
Page 5
2 2 Getting S t arted Introducing the Heat-N-Glo Gas Appliances Heat-N-Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. The information contained in this Installers Guide , unless noted otherwise, applies to all models and gas control [...]
-
Page 6
3 VENTING AND INST ALLA TION 1. Heat -N-Glo gas inserts are designed for recessed installations into solid fuel Masonry or Factory Built Non Combustible fireplaces that have been installed in accordance with the National, Provincial, S tate and local building codes. 2. Minimum fireplace opening requirements are shown in Figure 1 of this instal- lat[...]
-
Page 7
4 When planning a fireplace insert installation, its necessary to determine: The vent system configuration to be used. Gas supply piping. Whether optional accessoriesdevices such as a wall switch, or remote controlare desired. Figure 1. Diagram of the AT -ZC TOP VIEW MINIMUM FIREPLACE SIZE FRONT WIDTH : 23 3/4 ” (603 mm) REAR[...]
-
Page 8
5 V ent System Installation Precautions Before starting installation of vent kits, the installer should read these instructions and the V ent Kit Instructions to ensure that a proper vent installation is completed. Consult your local Building Codes before beginning the Installation. W ARNING THIS GAS INSERT AND VENT ASSEMBL Y MUST BE VENTED DIRECTL[...]
-
Page 9
6 A vertical vent termination system installed on this model will include one (1) length of 3-inch flexible vent pipe for the combustion air , one (1) pipe-to-cap adaptor , and one (1) SLK-991DA or SLK-980D V ertical termination Cap. NOTE: The damper of the masonry chimney may need to be removed to allow installation of the flexible- vent pipe. Thi[...]
-
Page 10
7 TO A VOID DOWNDRAFTS AND/OR COLD AIR PROBLEMS, IT IS RECOMMENDED TO SEAL OFF THE AREA BETWEEN THE TERMINA TION CAP AND THE TOP OF THE SOLID-FUEL CHIMNEY OPENING INTO WHICH THE VENT CAP HAS BEEN INST ALLED. WHEN USING THE LINK-DV4-30 VENT SYSTEM, IT IS REQUIRED TO SEAL AROUND THE FLEXIBLE VENT PIPES IN THE DAMPER AREA. SEE FIGURE 3. USE FIBERGLASS[...]
-
Page 11
8 Figure 3. W ARNING THE EXHAUST PIPE MUST ONL Y BE CONNECTED TO THE EXHAUST ST ARTING COLLAR OF THE UNIT AND THE CENTER COLLAR OF THE TERMINA TION CAP . THE INLET AIR PIPE MUST ONL Y BE CONNECTED TO THE INLET A IR COLLAR OF THE UNIT AND EITHER A T T ACHED TO THE INLET A IR COLLAR OF THE TERMINA TION CAP OR TERMINA TED IN THE CHIMNEY . This option [...]
-
Page 12
9 Figure 4 Figure 5 EXHAUST ST ARTING COLLAR INLET AIR ST ARTING COLLAR[...]
-
Page 13
10 1. Place the insert into position. 2. Level the insert from side to side and from front to back. If necessary use the legs included in the manual bag. Screw the legs into the nuts installed in the bottom rear of the insert. T urn legs in until insert is level. Step 3 The Gas Control Systems W ARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL. [...]
-
Page 14
11 Step 4 The Gas Supply Line NOTE: Have the gas supply line installed by a qualified service technician in accordance with all building codes . NOTE: Before the first firing of the fireplace, the gas supply line should be purged of any trapped air . NOTE: Consult local building codes to properly size the gas supply line leading to the 1/2 inch (13[...]
-
Page 15
12 Step 5 Gas Pressure Requirement s Pressure requirements for Heat-N-Glo gas appliances are shown in the table below . Pressure Natural Gas Propane Mini mum 5.0 inches 1 1.0 inches Inlet Pressure w .c. w .c. Maximum Inlet 14.0 inches 14.0 inches Gas Pressure w.c. w . c. Manifold 3.5 inches 10.0 inches Pressure w .c. w .c. A one-eighth (1/8) inch ([...]
-
Page 16
13 Optional Accessories Optional fan and remote control kits require that 1 10- 120 V AC be supplied to the factory installed junction box. Run the cord out the notch in the surround and plug into a convenient outlet. Remote W all Switch Position the remote wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less leng[...]
-
Page 17
14 NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED , IT MUST BE REPLACED WITH TYPE 105 DEGREE C RA TED WIRE. NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED , IT MUST BE REPLACED WITH TYPE 105 DEGREE C RA TED WIRE. BLOWER BLOWER RECEPT ACLE JUNCTION BO X V ARIABLE SPEED CONTROL TEM[...]
-
Page 18
15 GLASS DOOR Remove the glass door from the unit. Cover the top of the burner with a single layer of ember material. Then sprinkle GE-93 on top of the burner . Save the remaining ember materials for use during fireplace servicing. Replace the glass door . Reset the three glass eye bolts, be sure they are securely latched. R[...]
-
Page 19
16 Combustible materials MUST NEVER overlap onto the front face. Step 8 Inst alling T rim Surrounds NOTE: REMOVE FRONT TRIM DOOR AND GLASS DOOR ASSEMBLIES FROM THE INSERT BEFORE SURROUND INST ALLA TION. 1. Find the coiled low voltage wires and ON/OFF switch attached to outer right side of the insert. See Figure 12. 2. Disconnect the ON/OFF switch f[...]
-
Page 20
17 3. Run the low voltage lead wires up the back of the right side of the surround and secure them with the three wire ties found there. Re-connect the low voltage wires to the short wires of the ON/OFF switch. 4. Position surround on face of unit by hooking surround behind top ledge on unit. Then push flush on unit and secure by bending three hold[...]
-
Page 21
18 Step 9 Before Lighting the Appliance Before lighting the appliance, be sure to do the following: Review safety warnings and cautions Read the Safety and W arning Information section at the beginning of this Installers Guide . Double-check for gas leaks Before lighting the appliance, double-check the unit for possible gas leaks. Double-ch[...]
-
Page 22
19 4 Maint aining and Servicing Y our Appliance Appliance Maintenance Although the frequency of servicing and maintenance will depend on use and the type of installation, you should have a qualified service technician perform an appliance check-up at the beginning of each heating season. See the table below for specific guidelines regarding each ma[...]
-
Page 23
20 ST ANDING PILOT 3/8" (10 mm) Figure 14. Burner Flame Patterns MAKE SURE THE FLAMES ARE STEADYNOT LIFTING OR FLOA TING . Figure 15. Pilot/Ignitor Flame Patterns[...]
-
Page 24
21 PAR T P A RT DESCRIPTI O N PAR T N U M B E R V al v e LP SRV60–523 V alv e NG SRV60–522 Pi ez o I gn i tor SRV418-513 T h erm opi le SR V 60–512 T h er m oco u pl e SR V446- 51 1 Pi lot O rifi ce LP SRV446–517 Pi lot O rifi ce NG SR V4 46–50 5 Pilo t Ass em bly LP SR V485- 51 1A Pilo t Ass em bl y N G SR V485 -5 10A Pi lot T u be SRV44[...]
-
Page 25
22 PAR T P A RT DESCRIPTI O N P A RT NUM BE R Bu r n er SR V485-275A Bu r n er O ri fi ce N G SR V60-800 Bu r n er O r i fi ce LP SR V60-801 R otory Sw i tch SR V436-525A G l ass Door Assem b ly G L A -A T Z C G r ate Assem bl y SR V485-360A R efractory SR V485-700 St anding Pilot Continued[...]
-
Page 26
23 St anding Pilot (Cont.) Accessories A CCESSO R Y P A RT DESCR I PTI O N P A RT NUM BER R em ot e Con t ro l K i t R CH- 09A RC - S MA RT SM AR T -ST A T RC -MLT W al l Sw it c h Kit - Off Wh i te WS K-2 1 - White WS K -2 1 -W RC-SMART SMART -ST A T RC-ML T PAR T P A RT DES CRI PT I O N PAR T NUM BER Log #1 SR V447-701 Log #2 SRV446- 703 Log #3 S[...]
-
Page 27
24 Accessories - (Continued) ZC-3624-3 DF-ZC-Carch T rim Door ZC-3627-4 DF-ZC T rim Door ZC-4028-3 ZC-3627-3[...]
-
Page 28
25 DF-ZC32- T rim Door DF-ZC36- T rim Door DF-ZC32-Carch T rim Door DF-ZC36- Carch Door Accessories - (Continued)[...]