Heat & Glo LifeStyle ST-36TRB-IPI manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 82 pages
- 5.38 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Indoor Fireplace
Heat & Glo LifeStyle SL-750TV-IPI-D
54 pages 3.3 mb -
Indoor Fireplace
Heat & Glo LifeStyle Montana-42
44 pages 2.32 mb -
Indoor Fireplace
Heat & Glo LifeStyle ST-42TVFL-IPI
27 pages 1 mb -
Indoor Fireplace
Heat & Glo LifeStyle SLR (COSMO)
67 pages 3.27 mb -
Indoor Fireplace
Heat & Glo LifeStyle VRT-GY-N-AUB
75 pages 12.36 mb -
Indoor Fireplace
Heat & Glo LifeStyle CFL-30LP-B
21 pages 1.1 mb -
Indoor Fireplace
Heat & Glo LifeStyle 6000XLT-CDN
48 pages 1.61 mb -
Indoor Fireplace
Heat & Glo LifeStyle EM-415H
52 pages 5.12 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Heat & Glo LifeStyle ST-36TRB-IPI. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Heat & Glo LifeStyle ST-36TRB-IPI ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Heat & Glo LifeStyle ST-36TRB-IPI décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Heat & Glo LifeStyle ST-36TRB-IPI devrait contenir:
- informations sur les caractéristiques techniques du dispositif Heat & Glo LifeStyle ST-36TRB-IPI
- nom du fabricant et année de fabrication Heat & Glo LifeStyle ST-36TRB-IPI
- instructions d'utilisation, de réglage et d’entretien de l'équipement Heat & Glo LifeStyle ST-36TRB-IPI
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Heat & Glo LifeStyle ST-36TRB-IPI ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Heat & Glo LifeStyle ST-36TRB-IPI et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Heat & Glo LifeStyle en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Heat & Glo LifeStyle ST-36TRB-IPI, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Heat & Glo LifeStyle ST-36TRB-IPI, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Heat & Glo LifeStyle ST-36TRB-IPI. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 1 Models: ST -36TRB-IPI PIER-36TRB-IPI LCOR-36TRB-IPI RCOR-36TRB-IPI • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try t[...]
-
Page 2
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: _________________[...]
-
Page 3
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . ?[...]
-
Page 4
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 4 = Contains updated information. 13 Finishing A. Splatter Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 B. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 56 C. Facing Material .[...]
-
Page 5
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 5 B. Limited Lifetime W arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies Inc., on behalf of its hearth brands (”HHT”), extends the following warrant[...]
-
Page 6
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 6 B. Limited Lifetime W arranty (continued) 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: 7KLVZDUUDQWRQOFRYHUV++7DSSOLDQFHVWKDWDUHSXUFKDVHGW KURXJKDQ++7 DXWKRUL]HGGHDOHURUGLVWUL[...]
-
Page 7
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 7 B. T empered Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as de fi ned by the Con- sumer Product Safety Commiss[...]
-
Page 8
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned[...]
-
Page 9
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 9 2 2 Operat ing Instruc tions Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating ins[...]
-
Page 10
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.4. Avoid placing candles and other heat-sensitive objects on mantel or hearth. H[...]
-
Page 11
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 1 1 I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer . T o prolong battery life, remove them when using the transformer . 1. This appliance is equipped w[...]
-
Page 12
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 12 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace of f and allow it to completely cool. • Remove fi xed glass assembly . See Section 14.G. • Clean fi xe[...]
-
Page 13
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 13 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scrat[...]
-
Page 14
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 14 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc. • V erify term[...]
-
Page 15
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 15 Figure 3.1 IPI Pilot Flame Patterns Burner Ignition and Operation Frequency: Annually By: Quali fi ed Service T echnician T ools needed: Protective gloves, vacuum cleaner , whisk broom, fl ashlight, voltmeter , indexed drill bit set,[...]
-
Page 16
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 16 4 4 Get ting Star ted A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from picture[...]
-
Page 17
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 17 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outs[...]
-
Page 18
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 18 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). W ARNING! Risk of Fire or Burns! Provide adequate cl[...]
-
Page 19
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 19 C A B D B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should enclosed inside the chase. NOTICE: T reatment of ceiling[...]
-
Page 20
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 20 C A B D Figure 5.3 Clearances to Combustibles PIER-36TRB-IPI G F I I E H * Adjust framing dimensions for interior sheathing (such as sheetrock) PIER-36TRB-IPI AB C D E F G H I DVP Pipe SLP Pipe Rough Opening (Height) DVP Pipe* Rough Op[...]
-
Page 21
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 21 Note: All measurements in inches. MEASUREMENTS FROM TOP E DG E OF TH E OPE NIN G TO CEIL ING 5 10 11 12 2-1/2 13 14 15 16 17 18 19 32 9 10 11 12 8 7 6 5 4 3 25 18 MAX. MIN. See-Through Combustible Mantel PIER/LCOR/RCOR Combustible Mant[...]
-
Page 22
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 22 TOP VIEW 3-1/4 in. Min. 2-3/4 in. Min. 1/2 in. Min. Unlimited 1 in. Max. FIREPLACE OPENING Note: Clearance from opening to perpendicular wall. Figure 5.10 Non-Combustible Zone (PIER and ST) Figure 5.9 Combustible Mantel Leg or W all Pr[...]
-
Page 23
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 23 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* Over 7/12 to 8/12 ...[...]
-
Page 24
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 24 Figure 6.3 Minimum Clearances for T ermination O N P R Q X = AIR SUPPL Y INLET A = 12 inches................. clearances above grade, veranda, porch, deck or balcony B = 12 inches................. clearance to window or door that may b[...]
-
Page 25
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 25 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies a DVP or SLP venting system. Refer to Section 16.B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent[...]
-
Page 26
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 26 T o replace the fi rst starter elbow with two 45° elbows, refer to Figure 7.3. All other 90° elbows can be replaced with two 45° elbows. General Rules: • A maximum of three 90° elbows (or six 45° elbows) may be used in any vent[...]
-
Page 27
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 27 H 1 V 1 Figure 7.4 Figure 7.5 One Elbow T wo Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 1. T op V ent - Horizontal T ermination - (continued) V 1 Minimum H 1 Maximum Elbow only 1-1/2 ft. 457 mm 6 in. 152 mm 2-1/2 ft. 610 mm 1 ft. 305[...]
-
Page 28
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 28 Figure 7.6 1. T op V ent - Horizontal T ermination - (continued) Three Elbows H 2 H 1 V 2 V 1 V 1 Minimum H 1 Maximum V 2 Minimum H 2 Maximum V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft. 305 mm 6 in. 152 mm 1 ft. 305 mm 6 in. 1[...]
-
Page 29
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 29 Refractory Panel T o access the exhaust opening, remove the refractory panel and exhaust baffle. T o remove refractory panel, remove the two screws on top. To remove the exhaust baffle, remove the three screws securing it. T op V ent A[...]
-
Page 30
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 30 Figure 7.10 4. Center the exhaust restrictor in the open end of the exhaust outlet and secure through the slots on the exhaust restrictor with the 2-1/4 in. self tapping screws provided in the appliance manual bag. 5. Reinstall the exh[...]
-
Page 31
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 31 Figure 7.1 1 T wo Elbows H 1 V 2 V 1 Three Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 2 V 1 Figure 7.12 V 1 H 1 Maximum V 2 V 1 + V 2 Minimum One Elbow 2-1/2 ft. 762 mm * * * 2 ft. 607 mm 6 ft. 1.8 m * * * 4 ft. 1.2 m 12 ft. 3.7 m * * [...]
-
Page 32
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 32 3. Rear V ent - Horizontal T ermination Figure 7.13 Figure 7.14 No Elbow One 45° Elbow H 1 = 16 in. (406 mm) Maximum H 1 H 1 DO NOT use a 45º elbow in corner installations. Use two 90º elbow instead.[...]
-
Page 33
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 33 INSTALLED HORIZONTALLY H 3 H 2 V 1 H 1 3. Rear V ent - Horizontal T ermination - (continued) T wo Elbows Figure 7.15 Figure 7.16 Three Elbows H 2 V 1 H 1 H 1 Maximum V 1 Minimum H 2 Maximum H 1 + H 2 Maximum 1 ft. 305 mm 6 in. 152 mm 1[...]
-
Page 34
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 34 4. Rear V ent - V ertical T ermination One Elbow Figure 7.17 T wo Elbows Figure 7.18 V 1 H 1 INST ALLED HORIZONT ALL Y H 2 V 2 H 1 V 1 Minimum H 1 Maximum 1 ft. 305 mm 3 ft. 914 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft. 914 mm 7 ft. 2.1 m 4 ft[...]
-
Page 35
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 35 4. Rear V ent - V ertical T ermination - (continued) Three Elbows Figure 7.19 Three Elbows Figure 7.20 INST ALLED HORIZONT ALL Y H 3 H 2 V 1 H 1 V 2 V 1 H 2 H 1 H 1 H 2 H 3 V 1 Minimum H 1 + H 2 + H 3 Maximum *** 8 ft. 2.4 m 4 ft. 1.2 [...]
-
Page 36
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 36 A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops • Between wall shield fi restops • Around vent system F[...]
-
Page 37
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 37 Figure 8.5 W all Penetration * Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) inch (25.4 mm) above the center of the horizontal vent pipe. C D A* B* 10 in. 10 in. 12 in. 12 in. A* B* C D 43[...]
-
Page 38
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 38 D. V ertical Penetration Framing Figure 8.6 Figure 8.7 Installing the Attic Shield 3 F ASTENERS PER SIDE INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP INST ALLED BELOW CEILING CEILING FIR[...]
-
Page 39
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 39 E. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 and NFPA[...]
-
Page 40
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 40 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later [...]
-
Page 41
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 41 B. Rear V ent NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. NOTICE: Once the vent cap has been removed it CANNOT be reattached. Figure 9.5 Cut the metal retaining band. Figure 9.6 Remov[...]
-
Page 42
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 42 C. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent[...]
-
Page 43
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 43 1 0 10 Inst alling V ent Pi p e ( DVP and S LP P ip e ) A. Assemble V ent Sections (DVP Pipe Only) Attach V ent to the Firebox Assembly Note: The end of the pipe sec tions wi t h the lanced tabs wi ll face toward the appliance. Attach [...]
-
Page 44
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 44 B. Assemble V ent Sections (SLP Pipe Only) T o attach the fi rst vent component to the starting collars of the appliance: • Attach a DVP-2SL adapter to the starting collar of the appliance. • Lock the vent components into place by[...]
-
Page 45
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 45 120º Figure 10.8 Securing V ertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble V ent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown i[...]
-
Page 46
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 46 F . Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a fl at ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the fi restop. • Seal the gap be[...]
-
Page 47
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 47 G. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through the[...]
-
Page 48
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 48 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.18 Figure 10.18 TERMINA TION CAP I. Install V ertical T ermination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe sectio[...]
-
Page 49
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 49 Cap Speci fi cation Chart (depth without using additional pipe sections) 36 inch Multisided Series DVP-TRAPK1 T op V ent Depth DVP-TRAP1 Rear V ent Depth DVP-TRAPK2 T op V ent Depth DVP-TRAP2 Rear V ent Depth 2-7/8 in to 4-3/4 in 3-1/[...]
-
Page 50
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 50 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts. B. Gas Pressur[...]
-
Page 51
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 51 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric [...]
-
Page 52
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 52 Figure 12.1 Intelli fi re Ignition Wiring Diagram with Wall Switch or Thermostat Figure 12.2 Intelli fi re Ignition Wiring Diagram with Remote Receiver NOTE: 1 . Ignition module, valve, pilot, and wall switch operate on 3 volts. 120 [...]
-
Page 53
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 53 F . W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.4): • The power supply for the appliance must be brought into a switch box. • The power can then [...]
-
Page 54
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 54 1 3 13 Fi nishing Step 4. Center the splatter guard in front of the unit as shown in Figure 13.3. Place the splatter guard in the unit by guiding the top fl ap into proper position and then con- tinuing to guide the tabs on the side ?[...]
-
Page 55
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 55 Step 5. Fold bottom fl ap along score line as indicated in Figure 13.6 and tuck into valve access area of appliance. Splatter guard should fi t securely on front of unit. Once plumbing and wiring are complete on the fi replace, the [...]
-
Page 56
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 56 Note: All measurements in inches. MEASUREMENTS FROM TOP E DG E OF TH E OPE NIN G TO CEIL ING 5 10 11 12 2-1/2 13 14 15 16 17 18 19 32 9 10 11 12 8 7 6 5 4 3 25 18 MAX. MIN. See-Through Mantel Projection PIER/LCOR/RCOR Mantel Projection[...]
-
Page 57
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 57 Figure 13.16 Combustible Mantel Leg or W all Projections (Acceptable on both sides of opening) TOP VIEW 3-1/4 in. Min. 2-3/4 in. Min. 1/2 in. Min. Unlimited 1 in. Max. FIREPLACE OPENING Note: Clearance from opening to perpendicular wal[...]
-
Page 58
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 58 Figure 13.20 Inside fi t door Figure 13.21 Operable hinge door DOOR FINISHING MA TERIAL FINISHING MA TERIAL (Outside door width) (Includes 1/8 in. opening each side of door) 37 in. 37-1/4 in. Finishing materials over 1 inch thick. Fin[...]
-
Page 59
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 59 E. Elevated Hearth Systems Use the table below to identify the hearth system that will be used. The table will also help identify ef fects on the various dimensions. Some hearth systems will elevate the appliance off the fl oor at a g[...]
-
Page 60
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 60 A. Remove Fixed Glass Assembly See Section 14G. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the ?[...]
-
Page 61
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 61 F . Install the Log Assembly Figure 2. Factory Installed Logs Figure 2. Factory Installed Logs F F igure 1. Log Assembly Location igure 1. Log Assembly Location CAUTION: DO NOT reposition logs that have been factory installed! Follow t[...]
-
Page 62
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 62 F F igure 5. Placement of Log #2 igure 5. Placement of Log #2 2 2 F F igure 7. Placement of Log #3 igure 7. Placement of Log #3 3 3 2 2 INDENT A TIONS INDENT A TIONS STEP 3. Log #2 (SR V2128-705): The Y -shaped end of log #2 should res[...]
-
Page 63
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 63 I. Air Shutter Setting This appliance has an adjustable air shutter (which con- trols the primary air) factory set for the minimum vertical vent run (see Figure 12.15). If your installation has more than the minimum required vertical v[...]
-
Page 64
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 64 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed technicia[...]
-
Page 65
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 65 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl[...]
-
Page 66
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 66 1 6 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. Figure 16.1 See-Through Dimensions B C FRONT VIEW R[...]
-
Page 67
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 67 Figure 16.2 Pier Dimensions B C FRONT VIEW RIGHT VIEW LEFT VIEW A P L Ø K D M O N E ELECTRICAL ACCESS GAS LINE ACCESS J Ø K F G H i Location Inches Millimeters I 1-1/2 38 J 27 686 K 8 203 L 12 305 M 9-1/2 241 N 38 965 O 34-5/8 880 P [...]
-
Page 68
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 68 Figure 16.3 LCOR, RCOR Dimensions B C FRONT VIEW RIGHT VIEW ELECTRICAL ACCESS GAS LINE ACCESS LEFT VIEW A J Ø K L Ø K D F G H M P N i O E Location Inches Millimeters I 1-1/2 38 J 27 686 K 8 203 L 12 305 M 9-1/2 241 N 24-1/2 622 O 38 [...]
-
Page 69
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 69 B. V ent Components Diagrams Figure 16.4 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in. (337 mm) 1/2 in. TYP DVP90ST (90° Elbow)[...]
-
Page 70
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 70 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm).[...]
-
Page 71
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 71 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extension 13-3/4 in. (349 mm) 5 in. (127[...]
-
Page 72
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 72 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 10-1/2 in. (267 mm) 3-7/8 in. (98 mm) DVP-TV VerticalTermination Cap 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) [...]
-
Page 73
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 73 B. V ent Components Diagrams (continued) Figure 16.8 V ent Components 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) DVP-HRC-SS Optional Wire Harness DESCRIPTION P ART NUMBER 10 ft. PV Wire Harness PVI-WH10 20 ft. PV Wire Harness P[...]
-
Page 74
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 74 B. V ent Components Diagrams (continued) Figure 16.9 SLP Series V ent Components EFFECTIVE HEIGHT/ LENGTH 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 9-7/8 in. 251 mm 6-1/2 in. 165 [...]
-
Page 75
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 75 B. V ent Components Diagrams (continued) Figure 16.10 SLP Series V ent Components SLP-SNKD Snorkel T ermination Cap SLP-TVHW V ertical T ermination Cap SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-DCF-BK Ceiling Firestop Black SL[...]
-
Page 76
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 76 C. Service Parts ST -36TRB-IPI Beginning Manufacturing Date: Nov . 2008 Ending Manufacturing Date:______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model num[...]
-
Page 77
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 77 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocke[...]
-
Page 78
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 78 C. Service Parts LCOR-36TRB-IPI Beginning Manufacturing Date: Nov . 2008 Ending Manufacturing Date:______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model nu[...]
-
Page 79
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 79 C. Service Parts RCOR-36TRB-IPI Beginning Manufacturing Date: Nov . 2008 Ending Manufacturing Date: ______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model n[...]
-
Page 80
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 80 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocke[...]
-
Page 81
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 81 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocke[...]
-
Page 82
Heat & Glo • ST -36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev . H • 8/1 1 82 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the loc[...]