Heat & Glo LifeStyle Wood Burning Fireplace EXCLAIM-36 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 56 pages
- 6.03 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Indoor Fireplace
Heat & Glo LifeStyle SL-950TV-IPI-E
47 pages 4.54 mb -
Indoor Fireplace
Heat & Glo LifeStyle Cosmo-130
35 pages 3.46 mb -
Indoor Fireplace
Heat & Glo LifeStyle XLR-N-AU
70 pages 10.54 mb -
Indoor Fireplace
Heat & Glo LifeStyle CF750ENH
28 pages 1.24 mb -
Indoor Fireplace
Heat & Glo LifeStyle EM-485TH
52 pages 5.12 mb -
Indoor Fireplace
Heat & Glo LifeStyle 6100PLUS
40 pages 1.87 mb -
Indoor Fireplace
Heat & Glo LifeStyle BE-41
31 pages 1.21 mb -
Indoor Fireplace
Heat & Glo LifeStyle PALOMA-BZ-MOD
59 pages 2.77 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Heat & Glo LifeStyle Wood Burning Fireplace EXCLAIM-36. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Heat & Glo LifeStyle Wood Burning Fireplace EXCLAIM-36 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Heat & Glo LifeStyle Wood Burning Fireplace EXCLAIM-36 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Heat & Glo LifeStyle Wood Burning Fireplace EXCLAIM-36 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Heat & Glo LifeStyle Wood Burning Fireplace EXCLAIM-36
- nom du fabricant et année de fabrication Heat & Glo LifeStyle Wood Burning Fireplace EXCLAIM-36
- instructions d'utilisation, de réglage et d’entretien de l'équipement Heat & Glo LifeStyle Wood Burning Fireplace EXCLAIM-36
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Heat & Glo LifeStyle Wood Burning Fireplace EXCLAIM-36 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Heat & Glo LifeStyle Wood Burning Fireplace EXCLAIM-36 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Heat & Glo LifeStyle en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Heat & Glo LifeStyle Wood Burning Fireplace EXCLAIM-36, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Heat & Glo LifeStyle Wood Burning Fireplace EXCLAIM-36, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Heat & Glo LifeStyle Wood Burning Fireplace EXCLAIM-36. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
1 Owner ’ s Manual Installation and Operation Models: EXCLAIM-36 EXCLAIM-42 Wood Burning Fireplace DO NOT DISCARD THIS MANUAL NOTICE • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operati[...]
-
Page 2
2 Read this manual before installing or operating this fi replace. Please retain this owner ’ s manual for future reference. Homeowner Reference Information Model Name: Date purchased/installed: Serial Number: Location on fi replace: Dealership purchased from: Dealer phone: Notes: We recommend that you record the following pertinent information[...]
-
Page 3
3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury . ?[...]
-
Page 4
4 W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or Canada. W arranty starts with date of purchase b[...]
-
Page 5
5 This limited warranty does not extend to or include surface ? nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, ? rebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/or corrosion on any of the metal surfaces, cast iron components, baf? es, ? repots, doors, or ? rebox area are no[...]
-
Page 6
6 1 1 Listing and Code Appro v als NOTICE: This fireplace is tested and approved as a decorative fi replace. It should not be factored as a primary heat source in residential heating calculations. W ARNING! Risk of Fire! Hearth & Home T echnologies disclaims any responsibility for , and the warranty and agency listing will be voided by the fol[...]
-
Page 7
7 2 2 Operat ing Instr uct ions W ARNING! DO NOT operate fi replace before reading and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury . User Guide W ARNING Hot glass will cause burns. • DO NOT touch glass until it is cooled • NEVER allow children to touch gl[...]
-
Page 8
8 • The fi rst three or four fi res should be of moderate size to allow the oils and binders to be burned from the fi replace and the refractory and paint to cure. Y ou may notice an industrial odor the fi rst few fi res. This is considered normal. • Use well-seasoned wood. • Open the fl ue damper to a fully open position. • Place cru[...]
-
Page 9
9 FULL Y OPEN CORRECT P ARTL Y CLOSED INCORRECT P ARTL Y OPEN INCORRECT FULL Y CLOSED CORRECT Figure 2.2 Operating Positions of Bi-fold Doors W ARNING! Risk of Fire and Smoke! Fireplaces equipped with doors should be operated only with doors fully open or doors fully closed. If doors are left partly open, gas and fl ame may be drawn out of the fi[...]
-
Page 10
10 M. Wood Fuel Hardwood vs Softwood Y our fi replace performance depends on the quality of the fi rewood you use. • Seasoned wood contains about 8,000 BTUs per pound . • Hard woods are more dense than soft woods. • Hard woods contain 60% more BTUs than soft woods. • Hard woods require more time to season, burn slower and are harder to ig[...]
-
Page 11
11 3 3 Maintainance and Ser vice Figure 3.1 Chimney & T ermination Cap Cleaning A. Disposal of Ashes Frequency: When they reach bottom of grate By: Homeowner W ARNING! Risk of Fire! Ashes could contain hot em- bers. • Place ashes in a metal container with a tight- fi tting lid. • The closed container should be placed on a noncombustible ?[...]
-
Page 12
12 C. Check Firebox Refractory Frequency: After each ash removal By: Homeowner D. Inspect Grate Frequency: After each ash removal By: Homeowner Inspect grate for: • W arping or sagging 1-1/2 in. (38 mm) or more • Broken welds • Burn-through of grate bars For safe operation, replace only with an approved grate from Hearth & Homes T echnolo[...]
-
Page 13
13 4 4 T roubleshooting Guide Start Fire Problems Possible Cause Solution Can’t get fi re started Excessive smoke or spillage Burns too slowly Smolders, sizzles Not enough kindling/paper or no kindling/paper Use dry kindling, more paper . Arrange kindling & wood for air movement. Damper closed/not fully open Open damper . Not enough air for [...]
-
Page 14
14 5 5 Get ting Star ted A. T ypical Fireplace System Installer Guide Heat & Glo • EXCLAIM-36, EXCLAIM-42 • 4013-251 Rev C • 1 1/08 ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Non-combustible roof flashing maintains minimum clearance around chimney A[...]
-
Page 15
15 Negative pressure results from the imbalance of air avail- able for the fi replace to operate properly . It can be stron- gest in lower levels of the house. Causes include: • Exhaust fans (kitchen, bath, etc.) • Range hoods • Combustion air requirements for furnaces, water heaters and other combustion appliances • Clothes dryers • Loc[...]
-
Page 16
16 Marginal Location: • Below peak Location NOT recommended: • Not the highest point of the roof • Wind loading possible Multi-level Roofs Windward Leeward Recommended Location: • Above peak Recommended: • Insulated exterior chase in cooler climates Recommended Location: • Above peak • Inside heated space Location NOT recommended: •[...]
-
Page 17
17 Before beginning the installation be sure the following tools and building supplies are available: Reciprocating saw Framing material Pliers Non-combustible sealant Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric drill and bits Plumb line Safety glasses Level T ape measure 1/2-3/4 in. length, #6 or #8 self-drill[...]
-
Page 18
18 6 6 F raming & Clearances F D E A 5/8 in. (16 mm) all configurations In an exterior chase or projecting into a garage Across a corner As a room divider Along a wall G B A G G B A 48 in. (1219 mm) min. H A H Note: Note: Exclaim-36 - 1 in. (25 mm) Exclaim-42 - 1 1/2 in. (38 mm) minimum distance from sides & back of fireplace to combustible[...]
-
Page 19
19 B. Clearances W ARNING! Risk of Fire! Y ou must comply with all minimum air space clearances to combustibles as speci fi ed in Fig- ure 6.2. DO NOT pack required air spaces with insulation or other materials. Heat & Glo • EXCLAIM-36, EXCLAIM-42 • 4013-251 Rev C • 1 1/08 (insulation) 0 in. to level of standoffs Attic Insulation Shield [...]
-
Page 20
20 B C A 2 in. (51 mm) min. air space clearance from chimney . Note: Framing must be extended straight up, all the way to the ceiling. Header MUST NOT be notched! D D = extra space needed for outside air connection. If outside air duct has no bend, this dimension may be reduced as long as minimum clearances are met. B A 24 in. [610 mm] 19 3/4 in. [[...]
-
Page 21
21 7 7 Installation of Fireplace CAUTION! Risk of Cuts/Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp. A. Things to Consider • Location of chimney air kit • Location(s) of outside air kit • Electrical connections and/or wall switch • Gas line piping Figure 7.1 Unpacking Back Refractory [...]
-
Page 22
22 • Remove smoke shield by removing fi ve screws. See Figure 7.3. Smoke shield is located at top of fi replace front. Figure 7.5 Shipping Spacers Figure 7.4 Removing the Screen Rods Front Face Smoke Shield Remove these screws. Skip Skip Figure 7.3 Removing Smoke Shield • Remove hearth stone by removing three corrugated shipping spacers (Figu[...]
-
Page 23
23 Not e: T o ensure pro per installati on, gas knoc kouts in the side r e f r a c t o r y s h o u l d b e p o s i t i o n e d t o w a r d s b a c k o f fi replace. See Figure 7 . 1 1. • Ti l t t o p o f s i d e r e f r a c t o r y t o w a r d s c e n t e r o f fi rebox w hen placing it into fi replac e. Push side refractory towards back corne[...]
-
Page 24
24 ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) )) ) ) )))) )) ))) )) )))))))) ) ))) )) )) ))))))) ))) ))))))) ))) ) ) ) ) ) ) ) ) ) ) ) ) 3 ft min. from top of uppermost chimney section to air inlet. Protective metal strips are placed 2 in. (51 mm) under the front of the fireplace and must extend beyond the front and sides o[...]
-
Page 25
25 Outlet placed higher than 3 ft below the termination cap Attic space Garage or combustible liquids storage Outlet blocked by snow , leaves, etc. Clear area outside house or in ventilated crawl space YES NO NO NO NO Use only duct materials specified by manufacturer (preferably with short run or mainly straight duct, except small dip for cold air [...]
-
Page 26
26 Chimney must extend beyond combustible roof structure Maintain minimum height of chimney above roof Additional support for tall chimneys Install roof flashing according to minimum requirements Maintain minimum clearances to combustibles as specified Offsets/returns may not exceed 30° from vertical Lock chimney sections together firmly to resist[...]
-
Page 27
27 A. Chimney Requirements Measure vertical distances from the base of the fi replace as shown in Figure 8.2. 6 ft (1.8 m) max. unsupported run 20 ft (6 m) max. pipe between an offset & return Ceiling Firestop 35 ft (10.7 m) max. straight unsupported chimney height 18.5 ft (5.6 m) min. height single offset-return 24 ft. (7.3 m) min. height dou[...]
-
Page 28
28 T able 8.2 B. Using Offsets/Returns • Use an of fset/return to bypass overhead obstructions. • An of fset and return can be used as a single entity or separated by chimney section(s). W ARNING! Risk of Fire! DO NOT use offset/returns greater than 30°. Chimney draft will be restricted and could cause overheating and fi re. • Measure the s[...]
-
Page 29
29 Figure 8.4 Assembling Chimney Sections • Support the pipe during construction and check to be sure inadvertent loading has not dislodged the chimney section from the fi replace or at any chimney joint. • Attach a straight chimney section or an offset to the top of the fi replace. • Place inner fl ue to the inside of the chimney section [...]
-
Page 30
30 ROOM ABOVE (non-insulated ceiling) A TTIC ABOVE (insulated ceiling) B A Ceilng firestop from bottom Ceiling firestop from top Note: Use same dimensional lumber for framing ceiling firestop and joists. Figure 8.5 Installing the Ceiling Firestop • Install a ceiling fi restop whenever chimney penetrates ceiling/ fl oor . • Mark and cut an ope[...]
-
Page 31
31 3 in. (76 mm) overlap Insert three screws Bend inward 90° Bend remaining tabs to rest against pipe to prevent insulation from falling in. Figure 8.6 Prepare Attic Insulation Shield Installation of a ceiling fi restop is required • Refer to Figures 8.6 - 8.8. • Roll the shield (around the chimney if already installed) until you have a 3 in.[...]
-
Page 32
32 Figure 8.9 Ceiling/Attic Construction H. Complete Installation W ARNING! Risk of Fire! Y ou MUST maintain 2 in. (51 mm) air space to insulation and other combustible materials around the chimney system. Failure to do so could cause overheating and fi re. • Keep chimney sections from separating or twisting. • Y ou may secure straight chimney[...]
-
Page 33
33 Slanted Roofs Flat Roofs Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.6 m) above any portion of the roof or adjacent structures within 10 ft (3 m) of the chimney Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.6 m) above any portion of the roof or adjacent structures within 10 ft (3 m) of th[...]
-
Page 34
34 9 9 Chase Installations Ceiling Firestop Metal Chase T op Round T ermination Cap False Ceiling Insulation in the outside walls of the chase Attic Insulation Shield Chimney Ceiling Firestop T abs False Ceiling False Ceiling Insulation Insulation Figure 9.1 Chase Assembly 1 2 3 1. Fireplace and chimney enclosed in an exterior chase. 2. Chimney off[...]
-
Page 35
35 Slope Downward (1/4 in. per foot minimum) T urn-down Drip Edge Chase 2 in. (51 mm) Collar on Chase T op .018 (26 ga) min. Galvanized Chase T op Figure 9.3 Chase T op Construction B. Install Fireplace & Chimney Install as per Sections 7 and 8. Heat & Glo • EXCLAIM-36, EXCLAIM-42 • 4013-251 Rev C • 1 1/08 C. Install Chase T op • Y [...]
-
Page 36
36 D. Install T ermination Cap Install the chimney sections up through the chase enclo- sure. • Refer to termination cap instructions. W ARNING! Risk of Fire! The minimum overlap of cap to pipe (as shown in the following illustrations) MUST be met or chimney may separate from cap. Separation allows sparks, heat and embers to escape. NOTICE: Paint[...]
-
Page 37
37 Heat & Glo • EXCLAIM-36, EXCLAIM-42 • 4013-251 Rev C • 1 1/08 • TCT1 175 T erra Cotta Cap Chimney Pipe Chase T op T ermination Cap Chase Collar 2 in. (51 mm) Minimum Height T ermination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Place waterproof sealer under each flange of the termina- tion cap and on top of each scr[...]
-
Page 38
38 3 in. (76 mm) tall legs Ø 17 1/2 in. (444.5 mm) Round Hole to fit over cap Length x Width to fit inside shroud Figure 10.1 Radiation Shield 1 0 10 Shrouds • Chase top shrouds may be fi eld constructed where permitted by regional building codes. W ARNING! Risk of Fire! Shrouds must be constructed as speci fi ed. Improper construction may ove[...]
-
Page 39
39 3 in. (76 mm) Min. Opening Height Min. Base Dim Min. Height above radiation shield Min. Base Dim 3 in. (76 mm) Min. Radiation Shield Height from top of Chase Min. Opening Width Figure 10.3 Mailbox Style Shroud Dimensions Minimum Opening Height Minimum Base Dimension Min. Opening Width Min . Base Dimension Minimum Height above Radiation Shield Ch[...]
-
Page 40
40 1 1 11 Fi n i s hi n g A. Non-Combustible Materials • Materials which will not ignite and burn, composed of any combination of the following: - Steel - Iron - Brick - T ile - Concrete - Slate - Glass - Plasters • Materials reported as passing ASTM E 136, Standard T est Method for Behavior of Metals, in a V ertical T ube Furnace at 750° C B.[...]
-
Page 41
41 IMPORT ANT ! Hear th e x tension design must be determined before inst allation of fi replac e. Floor Noncombustible Framing Material Noncombustible Finishing Material Protective Metal Hearth Strips HX4 20 in. Min. Hearth Extension Figure 1 1.3 Raised Platform Hearth Extension Detail Raised Hearth Extension Framing The hearth framing must be co[...]
-
Page 42
42 Non-combustible Sealant After completing the framing and applying the facing materials over the framing, a bead of non-combustible sealant must be used to close off any gaps at the top and sides between the fi replace hearth. Non-combustible Sealant Figure 1 1.6 Place Non-combustible Sealant 30 in. min. 12 in. Min. 12 in. Min. Figure 1 1.7 Flus[...]
-
Page 43
43 D. Finishing Material Refer to Sections 1 1.A. and Sections 1 1.B. for combus- tible/noncombustible materials. Refer to Figure 1 1.9 for noncombustible zone. W ARNING! Risk of Fire! Y ou must maintain clearances. • Use only non-combustible framing material below standoffs. • Sheetrock, wood or other combustibles must NOT be used as sheathing[...]
-
Page 44
44 E. Combustible Mantel • See Figure 1 1.1 1. • A combustible mantel may be positioned no lower than 12 in./305 mm (EXCLAIM-36) OR 20 in./508 mm (EXCLAIM-42) above the top of the fi replace opening. • A combustible mantel may have a maximum depth of 12 in. (305 mm). • Combustible trim and materials cannot be placed within 6 in. (152 mm) o[...]
-
Page 45
45 F . Sidewalls/Surrounds • Adjacent combustible sidewalls must be located a minimum of 24 in. (610 mm) from the fireplace opening. • Combustible or non-combustible mantel legs, surrounds and stub walls may be constructed per Figure 1 1.12. B A 24 in. [610 mm] 19 3/4 in. [502 mm] 24 in. [610 mm] 28 5/8 in. [727 mm] FLUSH FRONT 4 in. [102 mm] B[...]
-
Page 46
46 Firebox Repack Insulation Knockout Combustible Materials Maintain air clearance to combustibles. Gas Line Combustible materials may be located at zero clearance to gas line beyond 4 in. (102 mm) from fireplace side. Gas Line 1 1/2 in. (38 mm) air space around pipe Refractory Seal with fireplace mortar or non-combust- ible sealant 4 in. (102 mm) [...]
-
Page 47
47 28-1/2 in. (724 mm) 55-1/2 in. (1410 mm) (Efective Height 49-1/8 in. (1248 mm) 49-5/8 in. (1260 mm) 59-1/4 in. (1505 mm) 7-5/8 in. (194 mm) 42 in. (1067 mm) Gas Knockout 18-1/2 in. (470 mm) 8-5/8 in. (219 mm) Gas Knockout 8-5/8 in. (219 mm) 9-5/8 in. (244 mm) 9-1/2 in. (241 mm) 9-1/4 in. (235 mm) Outside Air 34-1/2 in. (876 mm) 9-1/2 in. (241 mm[...]
-
Page 48
48 B. Optional Components Bi-fold Glass Doors 20 in. (508 mm) 66 in. (1676 mm) 1/2 in. (13 mm) HX4 Hearth Extension EXCLAIM-36 EXCLAIM-42 Description DM6036 DM8042 Glass doors - Bi-fold, clear view , black DM6036B DM8042B Glass doors - Bi-fold, clear view , polished brass DM6036S DM8042S Glass doors - Bi-fold, clear view , stainless steel HX4 HX4 H[...]
-
Page 49
49 C. Chimney Components The following pictures show only those chimney components which may be safely used with this fi replace. ID4 Insulated Duct UD4 Uninsulated Duct 42 in. (1067 mm) 4 in. (102 mm) i 42 in. (1067 mm) 4 in. (102 mm) i Heat & Glo • EXCLAIM-36, EXCLAIM-42 • 4013-251 Rev C • 1 1/08 Catalog # A B US CAN in mm in mm SL1 10[...]
-
Page 50
50 Heat & Glo • EXCLAIM-36, EXCLAIM-42 • 4013-251 Rev C • 1 1/08 AS10 Straight Attic Insulation Shield AS10 Straight Attic Insulation Shield Assembled Diameter: 17 in./432 mm Height: 24 in./610 mm AS10 Straight Attic Insulation Shield JB577 Chimney Joint Band CB576 Chimney Joint Band 13 in. (330 mm) 2 in. (51 mm) 13 in. (330 mm) A B 17 in[...]
-
Page 51
51 TR-TVK TR T op V ent Kit Heat & Glo • EXCLAIM-36, EXCLAIM-42 • 4013-251 Rev C • 1 1/08 TR1 1/TR444 - Round T ermination Cap TR1 1T/TR442 - Round T elescoping T ermination Cap ST1 175/ST475 - Square T ermination Cap TCT1 175 - T erra Cotta Cap 15-3/4 in. (400 mm) 32-3/8 in. (822 mm) 34-3/8 in . (873 mm) 14-3/4 in. (375 mm) 23 in. (584 m[...]
-
Page 52
52 A B C D LDS33/LDS46 Decorative Shroud Catalog # ABCD in. mm in. mm in. mm in. mm LDS33 36 914 36 914 8-1/2 216 1 1 279 LDS46 48 1219 72 1829 8-1/2 216 1 1 279 E D A C B Catalog # A B C D E LDS-BV in. 26 12-1/2 15-1/2 22 23 mm 660 318 394 533 584 LDS-BV Decorative Shroud Heat & Glo • EXCLAIM-36, EXCLAIM-42 • 4013-251 Rev C • 1 1/08 CT56[...]
-
Page 53
53 D. Service Parts 06/08 Service Parts Service Parts Diagram 36 in. Woodburning Fireplace Part number list on following page. EXCLAIM-36H, EXCLAIM-36T Beginning Manufacturing Date: March 2004 Ending Manufacturing Date: Active 1 3 4 5 6 7 8 9 2 T raditional Herringbone Refractories 06/08 Service Parts Service Parts List 36 in. Woodburning Fireplace[...]
-
Page 54
54 D. Service Parts (continued) 06/08 Service Parts Service Parts Diagram 42 in. Woodburning Fireplace Part number list on following page. Beginning Manufacturing Date: March 2004 Ending Manufacturing Date: Active 1 2 5 4 3 7 6 8 9 T raditional Herringbone Refractories EXCLAIM-42H, EXCLAIM-42T 06/08 Service Parts Service Parts List 42 in. Woodburni[...]
-
Page 55
55 T his page intentionally left blank. Heat & Glo • EXCLAIM-36, EXCLAIM-42 • 4013-251 Rev C • 1 1/08[...]
-
Page 56
56 – NOTES – E. Contact Information DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation. DO NOT DISCARD This product may be covered by one or mor[...]