Hellenbrand Iron Curtain System manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 28 pages
- 0.56 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Water System
Hellenbrand CH-4272
1 pages 0.01 mb -
Water Dispenser
Hellenbrand Iron Curtain System
28 pages 0.56 mb -
Water System
Hellenbrand Water Purification System NF 1.5"
2 pages 0.29 mb -
Water System
Hellenbrand 1
24 pages 1.3 mb -
Water System
Hellenbrand GRO Series
2 pages 0.16 mb -
Water System
Hellenbrand H-150 Series
2 pages 0.2 mb -
Water System
Hellenbrand CH-3672
1 pages 0.01 mb -
Water System
Hellenbrand 3.2
2 pages 0.61 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Hellenbrand Iron Curtain System. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Hellenbrand Iron Curtain System ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Hellenbrand Iron Curtain System décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Hellenbrand Iron Curtain System devrait contenir:
- informations sur les caractéristiques techniques du dispositif Hellenbrand Iron Curtain System
- nom du fabricant et année de fabrication Hellenbrand Iron Curtain System
- instructions d'utilisation, de réglage et d’entretien de l'équipement Hellenbrand Iron Curtain System
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Hellenbrand Iron Curtain System ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Hellenbrand Iron Curtain System et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Hellenbrand en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Hellenbrand Iron Curtain System, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Hellenbrand Iron Curtain System, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Hellenbrand Iron Curtain System. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
For systems manufactured after October 1997 Manufactured by: HELLENBRAND, INC. 404 Moravian Valley Road • PO Box 187 Waunakee, Wisconsin 53597 Phone: 608-849-3050 • Fax: 608-849-7398 Web: www.hellenbrand.com • Email: info@hellenbrand.com Owner ’ s Manual ©2003 TM TM[...]
-
Page 2
2 Congratulations on your purchase of one of the finest water treatment systems available today – the Iron Curtain System. This patented, non-chemical filter system, when properly applied will remove iron, manganese and/or hydrogen sulfide from your water supply. The Iron Curtain has been third-party tested by the Water Quality Association. An op[...]
-
Page 3
3 INST ALLA TION DA T A Date of Installation _______________________________________ Model No.___________________________________ Address of Installation ___________________________________________________________________________________ Installed By_____________________________________________________________________________________________ Raw Wa[...]
-
Page 4
4 IRON CUR T AIN the way to solve this problem is to use layers of media.” The advantages of a multi-media bed are: 1. Longer runs between backwash times. 2. Caking of the bed and breakthrough of turbidity are virtually eliminated. 3. Much higher service flow rates per square foot. 4. Higher degree of clarity because of the heavier, finer filter [...]
-
Page 5
5 Operating Conditions The Iron Curtain System has been validated by the WQA under their S-200 Filter Standard for the reduction/removal of iron, manganese, and/or hydrogen sulfide. The concentration limits listed below reflect the maximum individual limit that each contaminant was tested for separately without any interference of other contaminant[...]
-
Page 6
6 Caution: The water pressure is not to exceed 70 p.s.i.; water temperature is not to exceed 110 ° F; conditioner cannot be subject to freezing conditions; conditioner cannot be subject to a negative pressure or vacuum. On installations where there is the possibility of a negative pressure or vacuum, a vacuum breaker or check valve must be install[...]
-
Page 7
7 Instructions for Adding IC pH Correction Media See Figures 1, 2 & 3 on page 8.. 1. Place Iron Curtain System on bypass. (Close inlet and outlet valves and open bypass valve.) 2. Relieve pressure by manually advancing timer to back- wash position (see page 10). Unplug control valve after valve is shifted into backwash position and piston has s[...]
-
Page 8
8 Due to existing plumbing conditions, you may want to choose an alternate installation configuration. Refer to Figures 2 and 3 below for alternate installation diagrams. FIGURE 1 Carefully place a pry bar (long screwdriver, wrench, etc.) between the screws and apply pressure clockwise until tight. Be careful not to crease or tear the o-rings in th[...]
-
Page 9
9 How T o Set T imer 1 How to set days on which water conditioner is to regenerate. Rotate the skipper wheel until the number "1" is at the red pointer. Set the days that regeneration is to occur by sliding tabs on the skipper wheel outward to expose trip fingers. Each tab is one day. Tab at red pointer is tonight. Moving clockwise from t[...]
-
Page 10
10 How T o Manually Regenerate Y our W ater F ilter At Any T ime Slowly turn the manual regeneration knob clockwise until the drive motor starts running. The movement of the manual regeneration knob engages the program wheel and starts the regeneration program. The black center knob will make one revolution in approximately the following three hour[...]
-
Page 11
11 How T o Set Regeneration Cycle Program 1 How to set the regeneration cycle program. The regeneration cycle program on your Iron Curtain Filter has been factory preset, however, portions of the cycle or program may be lengthened or shortened to suit local conditions. To expose cycle program wheel, grasp timer in upper left- hand corner and pull, [...]
-
Page 12
12 Iron Curtain System Iron Curtain Wiring Diagram 1 2 3 WHITE BLK/WHT GREEN GREEN BLACK WH WHITE BLK/WHT BROWN YELLOW RED BLACK WHITE BLK/WHT BROWN YELLOW RED BLACK BLACK BLACK BLACK BLACK/WHITE TIMER MOTOR PROGRAM ACTUATOR SWITCH AIR PUMP SWITCH BLACK BLACK BLACK PROGRAM SWITCH HOMING SWITCH VALVE DRIVE MOTOR HOMING SWITCH TO AIR PUMP (Located be[...]
-
Page 13
13 Iron Curtain T imer Assembly ITEM NO. NO. REQ'D. PART NO. DESCRIPTION 1 ..................... 1 ............. 49-13870 ....... Timer Housing 2 ..................... 1 ............. 49-13011 ....... Cycle Actuator Arm 3 ..................... 1 ............. 49-49-60519 .. 24 Hour Gear 4 ..................... 1 ............. 49-13959 ....... [...]
-
Page 14
14 Iron Curtain Control Drive Assembly 32 10 7 9 11 12 8 4 13 14 1 2 31 33 17 16 18 19 28 30 29 26 25 24 21 20 27 34 23 15 ITEM NO. NO. REQ'D. PART NO. DESCRIPTION 1 ..................... 1 ............. 22-01 ............. IC Air Pump 2 ..................... 3 ............. 22-05 ............. IC Pump Feet 3 ..................... 3 ..........[...]
-
Page 15
15 Iron Curtain Aeration Pump Item Part No. No. Description Qty. 1 .......... 74-625646 .............. Screw/Head .................................... 4 2 .......... 74-660631-504 ....... Head ............................................... 1 3 .......... 74-623121 .............. O-Ring/Head .................................. 1 4 .......... 74-6253[...]
-
Page 16
16 Iron Curtain Aeration Pump Repair Instructions Air pump must be removed from tank and have power supply disconnected before proceeding. 1. Remove four front cover screws and remove front cover and cover gasket. 2. Remove four pump head screws and remove pump head. 3. Remove valve plate assembly. 4. Remove felt air filter on side of pump with a f[...]
-
Page 17
17 IC-10 Series Control V alve Assembly ITEM NO. NO. REQ'D. PART NO. DESCRIPTION 1 ..................... 1 ............. 49-11212NP .. Nickel Valve Body 2 ..................... 1 ............. 49-10757 ....... End Spacer 3 ..................... 6 ............. 49-10545 ....... Seal Ring 4 ..................... 5 ............. 49-11451 ....... [...]
-
Page 18
18 1 IC-12 Series Control V alve Assembly 14 1 2 3 4 5 11 10 9 8 7 6 12 13 15 12 19 20 16 17 18 ITEM NO. NO. REQ'D. PART NO. DESCRIPTION 1 .............. 1 ................... 49-14749-02NP .. Nickel Valve Body 2 .............. 1 ................... 49-10757 ............ End Spacer 3 .............. 6 ................... 49-10545 ............ S[...]
-
Page 19
19 Instructions for Replacing Piston Assembly and Seal Kit Replacing Piston Assembly See pages 17 and 18 for Parts Diagrams. 1. Place Iron Curtain System on bypass. (Close inlet and outlet valves and open bypass valve.) See Figures 1, 2 & 3 on page 8. 2. Relieve pressure by manually advancing timer to back- wash position (See page 10). Unplug c[...]
-
Page 20
20 Removing Power Head Removing Seal from Valve Body Piston Back Plate Seal Hook to Remove Seals Seal FIGURE 14 FIGURE 15 8. Using the puller, remove the first spacer. 9. Alternately remove the remaining seals and spacers in accordance with steps #7 and 8. 10. The last or end spacer does not have any holes for the pins of the puller to engage, ther[...]
-
Page 21
21 Removing Spacer from Valve Body Replacing Spacer in Valve Body Placing Seal in Brass Sleeve of Stuffer Removing Stuffer from Valve Body after Inserting Seal Puller to Remove Spacers Stuffer to Replace Spacers and Seals Spacer Stuffer Seal FIGURE 18 FIGURE 19 FIGURE 16 FIGURE 17 24. Open inlet valve no more than 1/4 turn and allow system to fill [...]
-
Page 22
22 IRON CURT AIN FLOW DIAGRAMS Step 1. Service Position Raw water enters the aeration- tank inlet, flows thru the inlet diffuser, thru a head of air, down thru the aeration tank, thru the pick-up tube, out the aeration head, into the filter control inlet, and down thru the multi-media bed. Filtered water is collected by the bottom distributor, flow[...]
-
Page 23
23 Step 3. Bleeding Off the Aeration System The Iron Curtain Control Center automatically shifts the controller into the Aeration recharge cycle. The air bleedoff valve opens up and allows raw water and/or air to pass thru the bleed off tube in the aeration tank to the drain. The air recharge valve is also open during this time; however, a check va[...]
-
Page 24
24 Step 5. Bleeding Off Excess Air The Iron Curtain Control Center automatically turns the air com- pressor pump off and allows both valves to remain open. The air bleedoff valve will bleed off any excess air which was pumped in during the previous step and the check valve in the recharge line prevents any backflow into the air compressor system. U[...]
-
Page 25
25 1a. Clean or replace drain line flow control 2a. Check for minimum specified flow and pressure requirements of filter system 3a. (Generally will only plug with the presence of iron bacteria) Clean aeration assembly and shock treat the water supply with chlorine as needed to control iron bacteria 4a. Rebed filter and correct the cause of fouling [...]
-
Page 26
26 Complaint Problem Cause Solution A. Dirt lodged under seat of valve B. Faulty or defective relief valve A. This can be expected when water is aerated under pressure A. See complaint #1 problem A & B A. Inlet check valve not sealing A. Reduced pressure in distribution system A. New filter backwashed during first 24 hours after installation B.[...]
-
Page 27
27 Winterizing Iron Curtain Systems (Optional) In certain climates where houses and/or cottages are not heated during the winter months, Iron Curtain Systems must have the water removed from them to protect from damage due to freezing. Following are instructions for “winterizing” Iron Curtain Systems. Prior to draining water distributor system [...]
-
Page 28
28 73-510 7/03-2500 IRON CURT AIN FIL TER SYSTEMS LIMITED W ARRANTY Hellenbrand, Inc., warrants to the original consumer/purchaser against defects in material and/or workmanship from the date of the original installation as follows: For a Period of FIVE YEARS: The 3/4” or 1” control valve(s) including electrical parts, internal parts, and valve[...]