Honda Automobiles EM3000 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 41 pages
- 2.06 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Portable Generator
Honda Automobiles EG2500X
55 pages 1.5 mb -
Portable Generator
Honda Automobiles EM5000SX
56 pages 2.14 mb -
Portable Generator
Honda Automobiles E900
38 pages 2.83 mb -
Portable Generator
Honda Automobiles EB2500X
52 pages 2.26 mb -
Portable Generator
Honda Automobiles EM7000is
100 pages 4.45 mb -
Portable Generator
Honda Automobiles EM3000c
55 pages 2.18 mb -
Portable Generator
Honda Automobiles EM400
35 pages 2.23 mb -
Portable Generator
Honda Automobiles EG5000X
40 pages 1.42 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Honda Automobiles EM3000. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Honda Automobiles EM3000 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Honda Automobiles EM3000 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Honda Automobiles EM3000 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Honda Automobiles EM3000
- nom du fabricant et année de fabrication Honda Automobiles EM3000
- instructions d'utilisation, de réglage et d’entretien de l'équipement Honda Automobiles EM3000
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Honda Automobiles EM3000 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Honda Automobiles EM3000 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Honda Automobiles en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Honda Automobiles EM3000, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Honda Automobiles EM3000, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Honda Automobiles EM3000. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Owner ’ s Manual EM3000•EM4000 ©1994 American Honda Motor Co., Inc. — All Rights Reserved[...]
-
Page 2
[...]
-
Page 3
Thank you for purchasing a Honda generator. This manual covers operation and maintenance of the EM 3000 and EM4000 generators. All information in this publication is based on the latest product information available at the time of approval for printing. Honda Motor Co., Ltd. reserves the right to make changes at any time without notice and without [...]
-
Page 4
CONTENTS CONTENTS 1. GENERATOR SAFETY ................................... 1 2. COMPONENT IDENTIFICATION ............................ 2 3. PRE-OPERATION CHECK ................................. 4 4. STARTING THE ENGINE ................................... 8 5. GENERATOR USE ....................................... 11 6. STOPPING THE ENGINE ............[...]
-
Page 5
1. GENERATOR SAFETY To ensure safe operation - l Place the generator at least 1 m (3 ft) away from buildings or other equipment when operating the generator. l Operate the generator on a level surface. If the generator is tilted, fuel spillage may result. l Exhaust gas contains poisonous carbon monoxide. Never run the generator in an enclosed area.[...]
-
Page 6
2. COMPONENT IDENTIFICATION VOLT METER PILOT LAMP VOLTAGE SELECTOR SWITCH ENGINE SWITCH FUEL VALVE , RECOIL ,/ STARTER, GRIP AC CIRCUIT BREAKER DC CIRCUIT RECEPTACLES - I OIL FILLER CAP ENGINE OIL DRAIN PLUi; 2[...]
-
Page 7
SPARK PLUG COVER FUEL GAUGE FUEL TANK CAP / tkJFFLER 3[...]
-
Page 8
3. PRE-OPERATION CHECK CAUTION: Be sure to check the generator on a level surface with the engine stopped. 1. Check the engine oil level. CAUTION: Engine oil is a major factor affecting engine performance and service life. Non-detergent or vegetable oils are not reommended. Use Honda cl-stroke oil, or an equivalent high detergent, premium quality m[...]
-
Page 9
NOTE: vyhen the oil runs lower than the specified level during operation, the oil alert switch automatically turns off to protect the engine from overheating. If this occurs, add oil to the top of the filler hole neck, then turn the switch on and restart the engine according to the instructions. OIL ALERT SWITCH 5[...]
-
Page 10
2. Check the fuel level. Use any regular grade automotive gasoline (unleaded gasoline is preferred) with a pump octane rating of 86 or higher. Never use an oil/gasoline mixture or dirty gasoline. Avoid getting dirt, dust or water in the fuel tank. CAUTION: Gasoline substitutes are not recommended; they may be harmful to the fuel system components. [...]
-
Page 11
3. Make sure that the AC circuit breaker is OFF and that nothing is con- nected to the DC terminals. The generator may be hard to start if a load is connected. AC ClRCUlT BREAKER DC TERMINALS[...]
-
Page 12
4. STARTING THE ENGINE 1. Turn the fuel valve on. FUEL VALVE 2. Pull the choke rod to CLOSE. CHOKE ROD[...]
-
Page 13
3. Turn the oil alert switch on. 4. Turn the engine switch on. ENGI 9[...]
-
Page 14
5. Pull the starter grip until compression is felt, then pull briskly. NOTE: Do not allow the starter grip to snap back. Return it slowly by hand. STARTER GRIP 6. Push the choke rod to OPEN as the engine warms up. CHOKE ROD[...]
-
Page 15
5. GENERATOR USE w To prevent electrical shock from faulty appliances, the generator should be grounded. Connect a length of heavy wire between the ground terminal and the ground source. CAUTION: l Limit operation requiring maximum power (EM3000: 3.0kVA. EM4000: 4.0 kVA) to 30 minutes. For continuous operation, do not exceed the ‘rated power of 2[...]
-
Page 16
AC applications 1. Start the engine and make sure the pilot lamp comes on. If not, the filament may be burnt out. 2. Turn the voltage selector switch to either position as required. When the switch is turned to “120V ONLY” position, you can use only 120V AC. At “12OVf24OV” position, you can use both 120V and 240V sources. 3. Switch on the A[...]
-
Page 17
DC application The DC terminals may be used for charging 12 volt automotive-type batteries only. m Batteries produce explosive gases. Keep sparks, flames, and cigarettes away. To prevent the possibility of creating .a spark near the battery, connect charging cables first to the battery, then to the generator, and disconnect cables first at the gene[...]
-
Page 18
6. STOPPING THE ENGINE To stop the engine in an emergency, turn the engine switch OFF. In normal use: 1. Turn the AC circuit breakers OFF and or disconnect the charging leads at the DC terminals. AC CIRCUIT BREAKER 2. Turn the engine switch OFF. -ENGINE SWITCH 14[...]
-
Page 19
3. Turn the fuel valve OFF. FUEL VALVE 15[...]
-
Page 20
7. MAINTENANCE The purpose of the maintenance schedule and adjustment is to keep the generator in the best operating condition. Inspect or service as scheduled in the table on the next page. m Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated. The exhaust contains poisonous carbo[...]
-
Page 21
Maintenance Schedule erform at every indi- Spark arrester Clean every 100 operating hours. NOTE (1) : Service more frequently when used in dusty areas. (2) : These items should be serviced by an authorized Honda dealer, unless the owner has the proper tools and is mechanically proficient. See the Honda Shop Manual.[...]
-
Page 22
Tool kit The tools supplied are necessary for performing some periodic maintenance, simple adjustments and repairs. Always keep the kit with the generator. Changing oil Drain the oil -while the engine is still warm to assure rapid and complete draining. 1. Remove the drain plug and filler cap, and drain the oil. Retighten the plug securely. 2. Refi[...]
-
Page 23
AIR CLEANER CLIP c i ‘CLIP Air cleaner service A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly (page 20). Service more frequently when operating the generator in extremely dusty areas. m Never use gasoline or low flash point solvents for cleaning the air cleaner el[...]
-
Page 24
2. Wash the element in a non-flammable or high flash point solvent and dry it thoroughly. 3. Soak the element in clean engine oil and squeeze out the excess oil. 4. Reinstall the air cleaner element and the cover. 20[...]
-
Page 25
Fuel filter service The filter prevents dirt or water which may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the filter should be cleaned. I. Turn the fuel valve OFF. Remove the filter cup. 2. Clean the cup thoroughly. 3. Reassemble. Do not damage the rubber gasket. m After installing the filter [...]
-
Page 26
Spark plug service Recommended spark plug: BPR4HS-10 (NG K) W14FPR-ULlO (ND) To ensure proper engine operation, the spark plug .must be properly gapped and free of deposits. 1. Remove the spark plug cover. 2. Clean any dirt from around the spark piug base. 3. Remove the spark plug cap. PLbG CAP 22[...]
-
Page 27
4. Use the wrench supplied in the tool kit to remove the spark plug. 5. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. 6. Measure the plug gap with a feeler gauge. The gap should be 0.9-1.0 mm (0.035-0.039 in). Correct as necessary by bending the side electrode. 7. Attach the plug washer. Thread the plug in by h[...]
-
Page 28
Spark arrester maintenance w If the generator has been running, the muffler will be very hot. Allow it to cool before proceeding. CAUTION: The spark arrester must be serviced every 100 hours to maintain its efficiency. 1. Loosen the bolts and nuts and remove the muffler. 2. Loosen two 8mm bolts to remove the exhaust pipe. 3. Check the muffler exhau[...]
-
Page 29
Before storing the unit for an extended period: 1. Be sure the storage area is free of excessive humidity and dust. 2. Drain the fuel - z: With the fuel valve OFF, remove and empty the filter cup.. Turn the fuel valve ON and drain the gasoline in the fuel suitable container. With the fuel valve OFF, remove and empty the filter cup.. Turn the fuel v[...]
-
Page 30
d. Drain the carburetor by loosening the drain screw. Drain the gasoline into a suitable container. DRAIN / SCREW e. Pull the starter grip until resistance is felt; the piston is coming up on its compression stroke. At this position, the exhaust and intake valves are closed, and this will help protect the engine from corrosion. STARTER GRIP 26[...]
-
Page 31
9. TROUBLESHOOTING A. When the engine wil! not stati: 1. Is there enough fuel? 2. Is the fuel valve on? 3. Is gasoline reaching the carburetor? To check, loosen the drain screw with the fuel valve on. m If any fuel is spilled, make sure the area is dry before testing the spark plug or starting the engine. Fuel vapor or spilled fuel may ignite. DRAI[...]
-
Page 32
a. Remove the spark plug cover and cap. Clean any dirt from around the spark plug base, then remove the spark plug. b. Install the spark plug in the plug cap. c. Turn the engine switch on. d. Turn the oil alert switch on. e. Grounding the side electrode to the stay, pull the recoil starter to see if sparks jump across the gap. ENGINE SWITCH GROUNDI[...]
-
Page 33
B. When the engine starts but stops immediately: Is there enough oil in the crankcase? If not, the oil alert switch will turn off after starting. C. No electricity at the AC receptacles: 1. Are the AC circuit breakers on? 2. Check the electrical appliance or equipment for any defects. D. No electricity at the DC terminals: 1. Is the DC circuit prot[...]
-
Page 34
10. SPEClFlCATlQNS Dimensions Length x Width x Height EM3000: 605 x 425 x 545mm (23.8 x 16.7 x 21.5 in) Dry weight EM4000: 650 x 425 x 575mm (25.6 x 16.7 x 22.6 in) EM3000: 64.0kg (141.1 lb) EM4000: 81 .Okg (178.6 lb) Engine Model Honda GE300 Honda G E400 Engine Type 4-stroke, side valve, 1 cylinder Displacement 272cm3 (16.6 cu in) 406cm3 (24.8 cu [...]
-
Page 35
(IINIRAKIR r----------------------.. O”N0 AUlNAL L ______m__________ --------J 1 c P 1 L----- _______ -----------L-z. ------ I3 . . . . . . BLACK G . , . . * * .GREEN k::::: RED .WHITE[...]
-
Page 36
Warranty Service Owner Satisfaction Your satisfaction and goodwill are important to your dealer and to us. All Honda warranty details are explained in the Distributor’s Limited Warranty. Normally, any problems concerning the product will be handled by your dealer’s service department. If you have a warranty problem that has not been handled to [...]
-
Page 37
Regional Office Locations NORTHWEST REGIONAL OFFICE (includes Alaska1 American Honda Motor Co.. Ins. Customer Relations Dspsrtmsnt P.O. 60x 30286 Portland. Ore@on 97220 T&phone: (6031256-l 186 J * MIDWEST REGIONAL OFFICE American Honda Motor Co.. Inc. NORTHEAST REGIONAL OFFCE American Honda Mot01 CO.. Inc. Cmtomer Relations Depsrtment P.O. B[...]
-
Page 38
Current customer service contact information: United States, Puerto Rico, and U.S. Virgin Islands: Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership'[...]
-
Page 39
NOTE[...]
-
Page 40
[...]
-
Page 41
Printed on Recycled Paper 00809909 PRINTED IN U.S.A. AHM 31899010 00X31-899-0100 POM 53161[...]