Intel 80C51FA manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 13 pages
- 1.43 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Computer Hardware
Intel FSB800 / DDR333 (PC2700)
96 pages 7.69 mb -
Computer Hardware
Intel 80219
30 pages 0.23 mb -
Computer Hardware
Intel IM-Q35 Series
69 pages 2.55 mb -
Computer Hardware
Intel BX80635E51660V2
232 pages 2.31 mb -
Computer Hardware
Intel EMX-965GME
43 pages 1.18 mb -
Computer Hardware
Intel BX80623I72700K
2 pages 0.18 mb -
Computer Hardware
Intel AXXRMS2AF080
2 pages 0.99 mb -
Computer Hardware
Intel 8VM533M-RZ-C
36 pages 2.89 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Intel 80C51FA. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Intel 80C51FA ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Intel 80C51FA décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Intel 80C51FA devrait contenir:
- informations sur les caractéristiques techniques du dispositif Intel 80C51FA
- nom du fabricant et année de fabrication Intel 80C51FA
- instructions d'utilisation, de réglage et d’entretien de l'équipement Intel 80C51FA
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Intel 80C51FA ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Intel 80C51FA et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Intel en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Intel 80C51FA, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Intel 80C51FA, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Intel 80C51FA. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
* Other brands and names are the property of their respective owners. Information in this document is provided in connection with Intel products. Intel assumes no liability whatsoever, including infringement of any patent or copyright, for sale and use of Intel products except as provided in Intel's Terms and Conditions of Sale for such produc[...]
-
Page 2
AUTOMOTIVE 80C51FA/83C51FA 270501 ± 1 Figure 1. 83C51FA Block Diagram 2[...]
-
Page 3
AUTOMOTIVE 80C51FA/83C51FA 80C51FA/83C51FA PRODUCT OPTIONS Intel’s extended and automotive temperature range product s are designed to meet the needs of those application s whose operating requirements exceed commercia l standards. Wit h the commercial standard temperature range, operationa l characteristics are guaranteed over the temperatur e r[...]
-
Page 4
AUTOMOTIVE 80C51FA/83C51FA PIN DESCRIPTIONS V CC : Supply voltage. V SS : Circuit ground. Port 0 : Port 0 is an 8-bit, open drain, bidirectional I/O port. As an output port each pin can sink several LS TTL inputs. Port 0 pins that have 1's written to them float, and in that state can be used as high-im- pedance inputs. Port 0 is also the multi[...]
-
Page 5
AUTOMOTIVE 80C51FA/83C51FA addresses (MOVX @ Ri), Port 2 emits the contents of the P2 Special Function Register. Port 3 : Port 3 is an 8-bit bidirectional I/O port with internal pullups. The Port 3 output buffers can drive LS TTL inputs. Port 3 pins that have 1's written to them are pulled high by the internal pullups, and in that state can be[...]
-
Page 6
AUTOMOTIVE 80C51FA/83C51FA 270501 ± 6 Figure 5. External Clock Drive Configuration IDLE MODE The user's software can invoke the Idle Mode. When the microcontroller is in this mode, power consump- tion is reduced. The Special Function Registers and the onboard RAM retain their values during Idle, but the processor stops executing instructions.[...]
-
Page 7
AUTOMOTIVE 80C51FA/83C51FA ABSOLUTE MAXIMUM RATINGS * Ambient Temperature Under Bias ...................................-40°C to +125°C Storage Temperature .......................-65°C to +150°C Voltage on Any Other Pin to V SS ........-0.5V to +6.5V I OL I/O Pin ........................................................15mA Power Dissipation (Ba[...]
-
Page 8
AUTOMOTIVE 80C51FA/83C51FA DC CHARACTERISTICS : (T A eb 40 § Ct o a 125 § C; V CC e 5V g 10%; V SS e 0V) (Continued) Symbol Parameter Min Typ Max Unit Test Conditions I TL Logical 1 to 0 Transition Current b 265 b 650 m AV IN e 2V (Ports 1, 2, and 3) RRST RST Pulldown Resistor 40 100 225 K X CIO Pin Capacitance 10 pF @ 1MHz, 25 § C I CC Power Su[...]
-
Page 9
AUTOMOTIVE 80C51FA/83C51FA 270501 ± 7 I CC Max at other frequencies is given by: Active Mode I CC Max e (3 c Osc Freq) a 4 Idle Mode I CC Max e (0.49 c Osc Freq) a 1.6 Where Osc Freq is in MHz, I CC is in mA. Figure 6. I CC vs Frequency 270501 ± 8 TCLCH e TCHCL e 5n s Figure 7. I CC Test Condition, Active Mode All other pins disconnected. 270501 [...]
-
Page 10
AUTOMOTIVE 80C51FA/83C51FA EXPLANATION OF THE AC SYMBOLS Each timing symbol has 5 characters. The first char- acter is always a `T' (stands for time). The other characters, depending on their positions, stand for the name of a signal or the logical status of that signal. The following is a list of all the characters and what they stand for. A:[...]
-
Page 11
AUTOMOTIVE 80C51FA/83C51FA EXTERNAL PROGRAM MEMORY READ CYCLE 270501 ± 12 EXTERNAL DATA MEMORY READ CYCLE 270501 ± 13 EXTERNAL DATA MEMORY WRITE CYCLE 270501 ± 14 11[...]
-
Page 12
AUTOMOTIVE 80C51FA/83C51FA SERIAL PORT TIMING-SHIFT REGISTER MODE Test Conditions : T A eb 40 § Ct o a 125 § C; V CC e 5V g 10%; V SS e 0V; Load Capacitance e 80 pF Symbol Parameter 12 MHz Oscillator Variable Oscillator Units Min Max Min Max T XLXL Serial Port Clock Cycle Time 1 12T CLCL m s T QVXH Output Data Setup to Clock 700 10T CLCL b 133 ns[...]
-
Page 13
AUTOMOTIVE 80C51FA/83C51FA AC TESTING INPUT, OUTPUT WAVEFORMS 270501 ± 17 AC Inputs during testing are driven at V CC b 0.5V for a Logic ``1'' and 0.45V for a Logic ``0''. Timing measurements are made at V IH min for a Logic ``1'' and V OL max for a Logic ``0''. FLOAT WAVEFORMS 270501 ± 18 For timing purpos[...]