Johnson Controls 13 SEER manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 12 pages
- 0.24 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Air Conditioner
Johnson Controls J15
40 pages 2.67 mb -
Air Conditioner
Johnson Controls S1-ECL25
1 pages 0.14 mb -
Air Conditioner
Johnson Controls 22 SEER
46 pages 2.31 mb -
Air Conditioner
Johnson Controls AL6B SERIES
18 pages 0.54 mb -
Air Conditioner
Johnson Controls 16 SEER - CZF
18 pages 0.54 mb -
Air Conditioner
Johnson Controls S1-ECL20
1 pages 0.14 mb -
Air Conditioner
Johnson Controls ROOMTOP R407C
2 pages 0.37 mb -
Air Conditioner
Johnson Controls S1-ECL05
1 pages 0.14 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Johnson Controls 13 SEER. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Johnson Controls 13 SEER ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Johnson Controls 13 SEER décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Johnson Controls 13 SEER devrait contenir:
- informations sur les caractéristiques techniques du dispositif Johnson Controls 13 SEER
- nom du fabricant et année de fabrication Johnson Controls 13 SEER
- instructions d'utilisation, de réglage et d’entretien de l'équipement Johnson Controls 13 SEER
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Johnson Controls 13 SEER ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Johnson Controls 13 SEER et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Johnson Controls en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Johnson Controls 13 SEER, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Johnson Controls 13 SEER, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Johnson Controls 13 SEER. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
347337-UIM-A-0408 R-22 OUTDOOR SPLIT -SYSTEM AIR CONDITIONING MODELS: 13 SEER A Y018-030 SERIES 1.5 TO 2.5 T ONS INSTALLATION MANUAL LISTED ISO 9001 Certified Quality Management System SECTION I: GENERAL The outdoor units are designed to be connected to a matching indoor coil with sweat connect lines. Sweat connect units are factory charged with re[...]
-
Page 2
347337-UIM-A-0408 2 Johnson Controls Unitary Products SECTION III: UNIT INST ALLA TION LOC A T IO N Before starting the installation, select and check the suitability of the location for both the indoor and outdoor unit. Observe all limitations and clearance requirements. The outdoor unit must have sufficient clearance for air entrance to the conde[...]
-
Page 3
347337-UIM-A-0408 Johnson Controls Unitary Produ cts 3 PIPING CONNECTIONS The outdoor condensing unit must be connected to the indoor evapora - tor coil using field supplied r efrigerant grade (ACR) co pper tubing that is internally clean and dry . Units shoul d be installed only with the tubing sizes for approved system combinations as specified i[...]
-
Page 4
347337-UIM-A-0408 4 Johnson Controls Unitary Products Connect the refrigerant lines u sing the following proced ure: 1. Remove the cap and Schrader core from both the liquid and vapor service valve service ports at the outdoor unit. Connect low pres- sure nitrogen to the liquid line service port. 2. Braze the liquid line to the liqui d valve at the[...]
-
Page 5
347337-UIM-A-0408 Johnson Controls Unitary Produ cts 5 SECTION V : INST ALLA TIONS REQUIRING AN ADD-ON TXV KIT For installations requiring a TXV kit, refer to the Installation Instruct ions accompanying the TXV kit. SECTION VI: EV ACU A TI ON It will be necessary to evacuate the system to 500 microns or less. If a leak is suspected, leak test with [...]
-
Page 6
347337-UIM-A-0408 6 Johnson Controls Unitary Products SECTION VIII: ELECTRICAL CONNECTIONS GENERAL INFORMA TION & GROUNDING Check the electrical supply to be sure that it meets the values specified on the unit nameplate and wiring label. Power wiring, control (low voltage) wiring, disconnect switch es and over current protection must be supplie[...]
-
Page 7
347337-UIM-A-0408 Johnson Controls Unitary Produ cts 7 For additional connection diagrams for a ll UP G equipment refer to “Low V oltage System Wiring” document available online at www . upgnet.com in the Product Catalog Section. FIGURE 9: Thermostat Chart - Single S tage AC with PSC Air Handler AC 1A Single Stage Air Conditioner – PSC Air Ha[...]
-
Page 8
347337-UIM-A-0408 8 Johnson Controls Unitary Products FIGURE 10: Thermostat Chart - Single S tage AC with PSC Air Handler AC 1B Single Stage Air Conditioner – PSC Air Handler C 24 – Volt Comm on Y Compressor Contactor SINGLE STAGE AIR CONDIT IONER MA SHP AHP ID MODELS SINGLE STAGE AIR CONDIT I O N ER Other Part Nu mbers: SAP = Legacy 265902 = 0[...]
-
Page 9
347337-UIM-A-0408 Johnson Controls Unitary Produ cts 9 FIGURE 1 1: Thermostat Chart - Single St age AC with PSC Fur nace AC 5D Single Stage Air Conditioner – Single Stage PSC Furnace HM1 Humidistat Y Full Stage Compressor G Fan *PP11C70224 THERMOSTAT RH 24 – Volt Hot (Heat XFMR) RC 24 – Volt Hot (Cool XFMR) W Full Stage Heat Clipping Jump er [...]
-
Page 10
347337-UIM-A-0408 10 Johnson Controls Unitary Products FIGURE 12: Thermostat Chart - Single S tage AC with PSC Furnace AC 5E Single Stage Air Conditioner – Single Stage PSC Furnace C 24 – Volt Comm on Y Compressor Contactor SINGLE STAGE AIR CONDIT IONER SINGLE STAGE AIR CONDIT I O N ER Y Full Stage Compressor G Fan *BP11C50124 *BN11C01124 *DP11[...]
-
Page 11
347337-UIM-A-0408 Johnson Controls Unitary Produ cts 11 INDICA TIONS OF PROPER OPERA TION Cooling 1. The outdoor fan should be running, with warm air being dis- charged from the top of the unit. 2. The indoor blower (furnace or air handler) will be operating, dis- charging cool air from the ducts. Co ils or other parts in the air cir- cuit should b[...]
-
Page 12
Subject to change without notice. Printed in U.S.A. 347337-UIM-A-0408 Copyright © 2008 by Johnson Controls, Inc. All rights reserved. Supersedes: 259715-UIM-A-0606 Johnson Contro ls Unitary Produc t s 5005 Y ork Driv e Norman, OK 7306 NOTES[...]