Lennox International Inc. XC21 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 19 pages
- 0.68 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Air Conditioner
Lennox International Inc. 506510-01
49 pages 1.7 mb -
Air Conditioner
Lennox International Inc. WING
34 pages 2.76 mb -
Air Conditioner
Lennox International Inc. PCO-20C
3 pages 0.14 mb -
Air Conditioner
Lennox International Inc. PCO-12C
3 pages 0.14 mb -
Air Conditioner
Lennox International Inc. Lennox Unit
4 pages 0.41 mb -
Air Conditioner
Lennox International Inc. Lennox Air Handler
16 pages 0.44 mb -
Air Conditioner
Lennox International Inc. HSXA12
4 pages 0.11 mb -
Air Conditioner
Lennox International Inc. HSXA15
4 pages 0.49 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Lennox International Inc. XC21. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Lennox International Inc. XC21 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Lennox International Inc. XC21 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Lennox International Inc. XC21 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Lennox International Inc. XC21
- nom du fabricant et année de fabrication Lennox International Inc. XC21
- instructions d'utilisation, de réglage et d’entretien de l'équipement Lennox International Inc. XC21
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Lennox International Inc. XC21 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Lennox International Inc. XC21 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Lennox International Inc. en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Lennox International Inc. XC21, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Lennox International Inc. XC21, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Lennox International Inc. XC21. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Page 1 7/2012 506923−01 *2P72012* *P506923-01* E 2012 Lennox Industries Inc. Dallas, T exas, USA THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE W ARNING The S tate of California has determined that this product may contain or produce a chemical or chemicals, in very low doses, which may cause serious illness or death. It may als[...]
-
Page 2
Page 2 UNIT DIMENSIONS − INCHES (MM) 39−1/2 (1003) 35−1/2 (902) 47 (1 194) 18−1/2 (470) 8 (203) 1 (25) 4−1/2 (1 14) LIQUID LINE INLET ELECTRICAL INLETS SIDE VIEW ACCESS VIEW DISCHARGE AIR 4−5/8 (1 17) BASE WITH ELONGA TED LEGS 16−7/8 (429) 8−3/4 (222) 26−7/8 (683) 3−3/4 (95) 30−3/4 (781) 3−1/8 (79) SUCTIOn LINE INLET UNIT SU[...]
-
Page 3
Page 3 XC21 SERIES INST ALL UNIT AW A Y FROM WINDOWS TWO 90 _ ELBOWS INST ALLED IN LINE SET WILL REDUCE LINE SET VIBRA TION PLACEMENT FIGURE 2 Install unit level or , if on a slope, maintain slope tolerance of 2 degrees (or 2 inches per 5 feet [50 mm per 1.5 m]) away from building structure. GROUND LEVEL MOUNTING SLAB BUILDING STRUCTURE DISCHARGE A[...]
-
Page 4
Page 4 IMPORT ANT ! If this unit is being matched with an approved line set or indoor unit coil that was previously charged with mineral oil, or if it is being matched with a coil which was manufactured before January of 1999, th e coil and line set must be flushed prior to inst alla- tion. T ake care to empty all existing trap s. Polyol es- ter (P[...]
-
Page 5
Page 5 XC21 SERIES STEP 2 −− REFRIGERANT PIPING −− Removing Existing Indoor Metering Device SENSING LINE TEFLON ® RING FIXED ORIFICE BRASS NUT LIQUID LINE ASSEMBL Y (INCLUDES STRAINER) LIQUID LINE ORIFICE HOUSING DISTRIBUT OR TUBES DISTRIBUT OR ASSEMBL Y REMOVE AND DISCARD WHITE TEFLON ® SEAL (IF PRESENT) 1. On fully cased coils, remove t[...]
-
Page 6
Page 6 STEP 2 −− REFRIGERANT PIPING −− Brazing Procedures A TTACH THE MANIFOLD GAUGE SET FOR BRAZING LIQUID AND SUCTION / V APOR LINE SERVICE V AL VES OUTDOOR UNIT LIQUID LINE SUCTION / V APOR LINE LIQUID LINE SERVICE VA LV E SUCTION / V APOR LINE SER VICE VA LV E A TT ACH GAUGES INDOOR UNIT SUCTION / V APOR SERVICE PORT MUST BE OPEN AND SE[...]
-
Page 7
Page 7 XC21 SERIES CAUTION Brazing alloys and flux cont ain materials which are hazardous to your health. Avoid breathing vapors or fumes from brazing operations. Perform operations only in well−ventilated areas. Wear gloves and protective goggles or face shield to protect against burns. W as h hands with soap and water af ter handling brazing al[...]
-
Page 8
Page 8 STEP 3 −− INST ALLING INDOOR EXP ANSION V AL VE This outdoor unit is designed for use in systems that include an exp ansion valve metering device. Se e the XC21 Product Specifications bulletin (EHB) for ap p r o v e d ex p a n s i o n va l v e kit ma t c h − u ps an d ap p l i c a t i o n in f o r m a t i o n . The expansion valve can [...]
-
Page 9
Page 9 XC21 SERIES STEP 4 −− LEAK TEST AND EV ACUA TION TO V APOR SER VICE V AL VE HFC−410A MANIFOLD GAUGE SET OUTDOOR UNIT HIGH LOW CONNECT GAUGE SET A. Connect the high pressure hose of an HFC−410A manifold gauge set to the vapor valve service port. NOTE Normally , the high pressure hose is connected to the liquid line port. However ,[...]
-
Page 10
Page 10 STEP 4 −− LEAK TEST AND EV ACUA TION (Continued) A. Open both manifold valves and start the vacuum pum p. B. Evacuate the line set and indoor unit to an absolute pressure of 23,000 microns (29.01 inches of mercury). NOTE During the early stages of evacuation, it is desirable to close the manifold gauge valve at least once. A rapid r[...]
-
Page 11
Page 1 1 XC21 SERIES STEP 5 −− ELECTRICAL −− Circuit Sizing and Wire Routing In the U.S .A., wiring must conf orm wit h current local codes and the cur rent National Elec tric Code (NE C). In Canada, wiring m ust confor m with current local codes and t he current Canadian Elec trical Code (CEC) . Refer to the furnace or a ir handler install[...]
-
Page 12
Page 12 NOTE For proper voltages, select control wires gauge per table below . WIRE RUN LENGTH A WG# INSULA TION TYPE LESS THAN 100’ (30 METERS) 18 TEMPERA TURE RA TING MORE THAN 100’ (30 METERS) 16 35ºC MINIMUM. NOTE Wire tie provides low voltage wire strain relief and maintains separation of field−installed low and high voltage cir[...]
-
Page 13
Page 13 XC21 SERIES STEP 5 −− ELECTRICAL (Continued) −− Out door Control (A175) Jumpers and T erminals 55 50 DEGREE TARGET 45 DEGREE TARGET 40 DEGREE TARGET (DEFAULT) 55 50 45 40 55 50 45 40 55 50 45 40 55 50 45 40 DEGREE TARGET 100 90 DEGREE TARGET 70 DEGREE TARGET 50 DEGREE TARGET 100 90 70 50 DEGREE TARGET 100 90 70 50 100 90 70 50 100 9[...]
-
Page 14
Page 14 STEP 5 −− ELECTRICAL (Continued) −− Field Control Wiring Th e following two illustrations provide examples of control wiring connections when using a non−communicating thermostat. For examples of control wiring in complete or p artial communicating systems, see the icomfort t −enabled thermosta t Quick Start Guide which is provi[...]
-
Page 15
Page 15 XC21 SERIES Y1 O R W1 G D R Y1 L C C B Y2 Y2 W O DS L T T W2 H H O C L Y2 DS DH G R Y1 W2 W1 1 2 4 5 Furnace ComfortSense [ 7000 Thermostats Catalog # Y0349 or Y2081 XC21 T wo − Stage Air Conditioner Control On − board link Low voltage thermostat wiring 3 1. Thermostat T terminals are used for outdoor sensor input. Use for thermostat’[...]
-
Page 16
Page 16 Charging The XC21 unit is factory−charged with enough HFC−410A refrigerant to accommodate a 15−foot length of refrigerant piping. Charge should be checked and adjusted using the tables provided on the charging procedure sticker on the unit access panel. Det ailed information is given in the XC21 Inst allation and Service Procedures ma[...]
-
Page 17
Page 17 XC21 SERIES XC21 Field Operational Checklist Unit Readings Cooling*** Heating*** Y1 First S tage Expected results during Y2 demand (toggle switch ON) Y2 Second S tage Y1 First St age Expected results during Y2 demand (toggle switch ON) Y2 Second S tage Compressor V oltage Same Same Amperage Higher Higher Condenser Fan motor Amperage Same or[...]
-
Page 18
Page 18 XC21 S tart−Up and Performance Checklist Customer Address Indoor Unit Model Serial Outdoor Unit Model Serial Solar Module Mfg and Model Serial Notes: ST ART−UP CHECKS Refrigerant T ype: Rated Load Amps Actual Amps Rated V olts Actual V olts Condenser Fan Full Load Amps Actual Amps: COOLING MODE V apor Pressure: Liquid Pressure: Supply A[...]
-
Page 19
Page 19 XC21 SERIES Homeowner Information CAUTION Before attempting to perform any service or mainte- nance, turn the electrical power to unit OFF at discon- nect switch. Cleaning of th e out door unit’s coil should be performed by a licensed professional service technician (or equivalent). Contact your dealer and set up a schedule (preferably tw[...]