Lincoln Electric PRO-MIG 175 IM810 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 36 pages
- 0.73 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Welder
Lincoln Electric IDEALARC SVM136-A
102 pages 1.56 mb -
Welder
Lincoln Electric 248HO
2 pages 0.06 mb -
Welder
Lincoln Electric 450 CE
32 pages 5.32 mb -
Welder
Lincoln Electric WELDMARK 135 PLUS IM767
47 pages 0.77 mb -
Welder
Lincoln Electric MAGNUM IM632-B
21 pages 0.46 mb -
Welder
Lincoln Electric COOL ARC 35 IM959
22 pages 0.88 mb -
Welder
Lincoln Electric IM847-D
49 pages 5.33 mb -
Welder
Lincoln Electric K2376-1
4 pages 0.72 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Lincoln Electric PRO-MIG 175 IM810. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Lincoln Electric PRO-MIG 175 IM810 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Lincoln Electric PRO-MIG 175 IM810 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Lincoln Electric PRO-MIG 175 IM810 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Lincoln Electric PRO-MIG 175 IM810
- nom du fabricant et année de fabrication Lincoln Electric PRO-MIG 175 IM810
- instructions d'utilisation, de réglage et d’entretien de l'équipement Lincoln Electric PRO-MIG 175 IM810
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Lincoln Electric PRO-MIG 175 IM810 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Lincoln Electric PRO-MIG 175 IM810 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Lincoln Electric en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Lincoln Electric PRO-MIG 175 IM810, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Lincoln Electric PRO-MIG 175 IM810, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Lincoln Electric PRO-MIG 175 IM810. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
P ro-MIG 175 OPERA TOR’S MANUAL IM810 July, 2005 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL A[...]
-
Page 2
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilatedareas or vent the engine exhaust fumes outdoors. _________________________________________________[...]
-
Page 3
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin[...]
-
Page 4
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical C[...]
-
Page 5
iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les circuits ?[...]
-
Page 6
v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay[...]
-
Page 7
vi vi T ABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications ........................................................................................A-1 Safety Precautions...........................................................[...]
-
Page 8
A-1 A-1 INST ALLA TION Fuse or Output Mode Input Voltage Breaker Size Input Amps Power Cord RATED 230V/60Hz 40 Super Lag 20/22 50 Amp, 250V, 208V/60Hz Three-Prong Plug (NEMA Type 6-50P) TECHNICAL SPECIFICA TIONS – Pro-MIG 175 INPUT – SINGLE PHASE ONL Y RA TED OUTPUT OUTPUT RECOMMENDED INPUT CABLE AND FUSE SIZES Height Width Depth Weight 12.0 in[...]
-
Page 9
A-2 A-2 INST ALLA TION SAFETY PRECAUTIONS Read entire installation section before starting installation. IDENTIFY AND LOCA TE COMPONENTS If you have not already done so, unpack the Pro-MIG 175 from its carton and remove all packing material around the Pro-MIG 175. Remove the following loose items from the carton (see Figure A.1): 1. Pro-MIG 175 2. [...]
-
Page 10
A-3 A-3 INST ALLA TION SELECT SUIT ABLE LOCA TION Locate the welder in a dry location where there is free circulation of clean air into the louvers in the back and out the front of the unit. A location that minimizes the amount of smoke and dirt drawn into the rear louvers reduces the chance of dirt accumulation that can block air passages and caus[...]
-
Page 11
A-4 A-4 INST ALLA TION Work Cable Installation Refer to Figure A.2. 1. Open the wire feed section door on the right side of the Pro-MIG 175. 2. Pass the end of the work cable that has the termi- nal lug with the smaller hole through the Work Cable Access Hole (1) in the case front. 3. Route the cable under and around the back of the Wire Feed Gearb[...]
-
Page 12
A-5 A-5 INST ALLA TION Pro-MIG 175 2 . With the cylinder securely installed, remove the cylinder cap. Stand to one side away from the out- let and open the cylinder valve very slightly for an instant. This blows away any dust or dirt which may have accumulated in the valve outlet. BE SURE TO KEEP YOUR FACE AWAY FROM THE VALVE OUTLET WHEN “CRACKIN[...]
-
Page 13
A-6 A-6 INST ALLA TION Line Cord Connection A 3 conductor line cord with a 50 amp, 250 volt, three- prong plug (NEMA Type 6-50P) is factory installed. Connect this plug to a mating grounded receptacle which is connected to an appropriate power supply per the U.S. National Electric Code and any applica- ble local codes. CONNECT TO A SYSTEM GROUNDING[...]
-
Page 14
B-1 B-1 OPERA TION Read entire operation section before operating the Pro-MIG 175. ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet clothing. Insulate yourself from work and ground. • Always wear dry insulating gloves. FUMES AND GASES can be dangerous. • Keep your head out of fumes. • Use ventila[...]
-
Page 15
Pro-MIG 175 Pro-MIG 175 3 2 1 4 B-2 B-2 OPERA TION ● No external shielding gas is required when used with Lincol .035 ” (0.9 mm) Innershield NR ® -211- MP electrode. ● Spindle accommodates both 8 in. (200 mm) diame- ter and 4 in. (100 mm) diameter spools of wire. WELDING CAP ABILITY The Pro-MIG 175 is rated at 130 amps, 20 volts, at 30% duty[...]
-
Page 16
B-3 B-3 OPERA TION WELDING OPERA TIONS SEQUENCE OF OPERA TION Wire Loading Refer to Figure B.2 and B.3. The machine power switch should be turned to the OFF ( “ O ” ) position before working inside the wire feed enclosure. The machine is shipped from the factory ready to feed 8 ” (200 mm) diameter spools [2.2 ” (56 mm) max. width]. These sp[...]
-
Page 17
B-4 B-4 OPERA TION Wire Threading Refer to Figure B.4 1 . Release the Spring Loaded Pressure Arm (1) rotate the Idle Roll Arm (2) away from the Wire Feed Drive Roll (3). Ensure that the groove size in the feeding position on the drive roll matches the wire size being used. See Maintenance section for further information. 2 . Carefully detach the en[...]
-
Page 18
B-5 B-5 OPERA TION Making A Weld 1. See “ Process Guidelines ” in this section for selec- tion of welding wire and shielding gas and for range of metal thicknesses that can be welded. 2. See the Application chart on the inside of the wire feed compartment door for information on setting the Pro-MIG 175 controls. Refer to Table B.1 for aluminum [...]
-
Page 19
Pro-MIG 175 B-6 B-6 OPERA TION The Pro-MIG 175 is suitable for .035" aluminum wire and .023" – .035" stainless wire. Refer to Table B.1 for recommended procedure settings. (Requires K586-1 regulator kit and K664-2 Aluminum - Stainless Feeding Kit.) It is important when changing between welding with steel wire and aluminum to exchan[...]
-
Page 20
B-7 B-7 APPLICA TION CHART Pro-MIG 175[...]
-
Page 21
C-1 C-1 ACCESSORIES OPTIONAL ACCESSORIES 1. K549-1 .035" (0.9 mm) Innershield® Welding Kit — Includes a contact tip, a gasless nozzle and a .030/.035 (.8/.9mm) cable liner to permit the Magnum ™ 100L gun and cable to use .035" (0.9 mm) diameter flux-cored electrode. The fitting on the end of the liner is stenciled with the maximum ra[...]
-
Page 22
C-2 C-2 ACCESSORIES INNERSHIELD (FCA W) CONVERSION Several changes are needed to convert the unit for operation with the Innershield (FCAW) process. The K549-1 Innershield Kit includes all the necessary accessories for this conversion and is provided for this purpose. The following conversions should be made using the contents of this kit: 1. Chang[...]
-
Page 23
MAINTENANCE SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Disconnect input power by removing plug from receptacle before working inside Pro-MIG 175. Use only grounded receptacle. Do not touch electrically “hot” parts inside Pro-MIG 175. • Have qualified personnel do the mainte- nance and trouble shooting work. ROUTINE MAINTENANCE POWER SOUR[...]
-
Page 24
D-2 D-2 MAINTENANCE GUN AND CABLE MAINTENANCE FOR MAGNUM™ 100L GUN Gun Cable Cleaning Clean cable liner after using approximately 300 lbs (136 kg) of solid wire or 50 lbs (23 kg) of flux-cored wire. Remove the cable from the wire feeder and lay it out straight on the floor. Remove the contact tip from the gun. Using low pressure air, gently blow [...]
-
Page 25
D-3 D-3 MAINTENANCE COMPONENT REPLACEMENT PROCEDURES CHANGING THE CONT ACT TIP 1. Refer to Figure D.2. Remove the gas nozzle from the gun by unscrewing counter-clockwise. 2. Remove the existing contact tip from the gun by unscrewing counter-clockwise. 3. Insert and hand tighten desired contact tip. 4. Replace gas nozzle. CHANGING DRIVE ROLL (Refer [...]
-
Page 26
D-4 D-4 MAINTENANCE 8. Screw the gas diffuser onto the end of the gun tube and securely tighten. 9. Replace the contact tip and nozzle. GUN HANDLE P ARTS The gun handle consists of two halves that are held together with a collar on each end. To open up the handle, turn the collars approximately 60 degrees counter-clockwise until the collar reaches [...]
-
Page 27
Pro-MIG 175 E-1 TROUBLESHOOTING E-1 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting Guide is provided to help you locate and repair poss[...]
-
Page 28
E-2 E-2 TROUBLESHOOTING PROBLEMS (SYMPTOMS) Major physical or electrical damage is evident. No wire feed, weld output or gas flow when gun trigger is pulled. Fan does NOT operate. No wire feed, weld output or gas flow when gun trigger is pulled. Fan operates normally. POSSIBLE CAUSE None Contact your local Authorized Field Service Facility. 1. Make[...]
-
Page 29
Pro-MIG 175 E-3 E-3 TROUBLESHOOTING PROBLEMS (SYMPTOMS) No wire feed when gun trigger is pulled. Fan runs, gas flows and machine has correct open circuit voltage (33 vcd maximum) – weld output. POSSIBLE CAUSE 1. If the wire drive motor is running make sure that the correct drive rolls are installed in the machine. 2. Check for clogged cable liner[...]
-
Page 30
Pro-MIG 175 E-4 E-4 TROUBLESHOOTING If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your LOCAL AUTHORIZED LINCOLN ELECTRIC FIELD SERVICE FACILITY for assistance before you proceed. CAUTION PROBLEMS (SYMPTOMS) Arc is unstable – Poor starting POSSIBLE CAUSE 1. Check for correct [...]
-
Page 31
F-1 F-1 WIRING DIAGRAMS W IRIN G DIA GR A M W ARNING HIGH VOLTAGE can kill Only qualified perso ns should install, use or service this machine. Do not operate with covers removed. Disconnect input power by unplugging po wer cord before se rvicing. Do n ot t ouch el ect ri ca lly l iv e par ts B M20143 ELECTRICAL S YMBOLS PER E153 7 CAVITY NUMBERING[...]
-
Page 32
NOTES[...]
-
Page 33
NOTES[...]
-
Page 34
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE PARA EL U[...]
-
Page 35
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes fro[...]
-
Page 36
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products •[...]