Maytag HVP41250VCGA manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 32 pages
- 0.79 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Water Heater
Maytag HRE2950S
36 pages 1.21 mb -
Water Heater
Maytag HRE21250PC
40 pages 1.79 mb -
Water Heater
Maytag HRE41250T
28 pages 0.48 mb -
Water Heater
Maytag HE3940S
36 pages 1.29 mb -
Water Heater
Maytag HRN11240X
32 pages 0.66 mb -
Water Heater
Maytag HE21250T
32 pages 1.24 mb -
Water Heater
Maytag HRX82DERT
32 pages 1.07 mb -
Water Heater
Maytag HN41240X
36 pages 1.53 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Maytag HVP41250VCGA. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Maytag HVP41250VCGA ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Maytag HVP41250VCGA décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Maytag HVP41250VCGA devrait contenir:
- informations sur les caractéristiques techniques du dispositif Maytag HVP41250VCGA
- nom du fabricant et année de fabrication Maytag HVP41250VCGA
- instructions d'utilisation, de réglage et d’entretien de l'équipement Maytag HVP41250VCGA
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Maytag HVP41250VCGA ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Maytag HVP41250VCGA et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Maytag en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Maytag HVP41250VCGA, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Maytag HVP41250VCGA, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Maytag HVP41250VCGA. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
1 www.maytagwaterheaters.com PRINTED IN THE U.S.A. 1005 P ART NO. 185380-000 FOR POT ABLE W A TER HEA TING ONL Y NOT SUIT ABLE FOR SP ACE HEA TING NOT FOR USE IN MANUF ACTURED (MOBILE) HOMES POWER VENT GAS W A TER HEA TER USER’S GUIDE Series T welve Model Numbers HVN41240PCGA HVP41240PCGA HVN41250PCGA HVP41250PCGA HVN41250VCGA HVP41250VCGA For Y [...]
-
Page 2
2 SAFE INST ALLA TION, USE AND SERVICE Y our safety and the safety of others is extremely important in the inst allation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety [...]
-
Page 3
3 SAFETY PRECAUTIONS[...]
-
Page 4
4 SAFE INST ALLA TION, USE AND SER VICE .................................................................................................................................... 2 SAFETY PRECAUTIONS ............................................................................................................................................................[...]
-
Page 5
5 Thank Y ou for purchasing a Maytag water heater . Properly inst alled and maintained, it should give you years of trouble free service. It is strongly suggested that this new water heater be professionally installed, contact Maytag Customer Service (1-800-788-8899) for recommended installers . Abbreviations Found In This Instruction Manual: • C[...]
-
Page 6
6 MA TERIALS AND BASIC T OOLS NEEDED Accessories T o simplify the installation Maytag has available the inst allation parts shown below . Y ou may or may not need all of these accessories depending on your type of installation. Call Mayt ag Customer Service at 1-800-788-8899 for an authorized installer . EXP ANSION T ANKS FOR THERMAL EXP ANSION CON[...]
-
Page 7
7 TYPICAL INST ALLA TION GET T O KNOW YOUR W A TER HEA TER - GAS MODELS A V ent Pipe–Exhaust B V ent T erminal C V ent Adapter-Rubber Boot D Blower Assembly E Cold Water Inlet F Inlet Water Shut-off V alve G Union H Inlet Dip T ube J Anode** FIGURE 1. K Hot Water Outlet L Outlet Receptacle (1 15 V AC) M T emperature-Pressure Relief V alve N Flue [...]
-
Page 8
8 TYPICAL INST ALLA TION FIGURE 2. MIXING V AL VE USAGE HOTTER W A TER CAN SCALD: W ater heaters are intended to produce hot water . Water heated to a temperature which will satisfy space heating, clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanentl[...]
-
Page 9
9 1. Turn “OFF” the gas supply to the water heater . If the main gas line Shut-off valve serving all gas appliances is used, also shut “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is completed, see Figures 3 and 4. 2. Turn “OFF” the water supply to the water heater at the w[...]
-
Page 10
10 FACTS TO CONSIDER ABOUT THE LOCA TION Carefully choose an indoor location for the new water heater , because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in manufactured (mobile) homes or outdoor installation. Whe[...]
-
Page 11
11 and 12" (30.5 cm) from the top. (S tandard clearance.) If clearances stated on the heater differ from standard clearances, install water heater according to clearances stated on the heater . Adequate clearance for servicing this appliance should be considered before installation, such as changing the anodes, etc. A minimum clearance of 5&qu[...]
-
Page 12
12 Chemical vapor corrosion of the flue, blower assembly and vent system may occur if air for combustion contains certain chemical vapors. S pray can propellant s, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which ar[...]
-
Page 13
13 The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of the water heater’s temperature-pressure relief valve is reached, the valve will relieve the excess pressure. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion.[...]
-
Page 14
14 Figure 16 shows the typical attachment of the water piping to the water heater . The water heater is equipped with 3/4 inch NPT water connections. NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the cold water inlet connection. Do not solder the cold water supply line directly to the cold water inlet. It[...]
-
Page 15
15 GAS PIPING Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 14 inch water column (3.5 kPa) for natural and propane gas (L.P .). The minimum inlet gas pressure shown on the rating plate is that which will permit firing at rated input. All gas piping must comply with local codes a[...]
-
Page 16
16 SEDIMENT TRAPS Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion. Before attaching the gas line be sure that all gas pipe is clean on the inside. T o trap any dirt or foreign material in the gas supply line, a drip leg (sometimes called a sediment trap) must be incorporated i[...]
-
Page 17
17 VENT CONNECTIONS TO BLOWER ASSEMBL Y Figure 15 shows the optimal placement of the 2" to 3" or 3" to 4" reducer; however , the vent can be reduced at any point in the vent system as long as the maximum vent length is not exceeded. FIGURE 21. VENTING AND INST ALLA TION Plan the layout of the vent system from the vent terminatio[...]
-
Page 18
18 The unit may be vented horizontally through a wall or vertically through the roof. Pipe runs must be adequately supported along both vertical and horizontal runs as follows: • For Schedule 40, 2" PVC, ABS, Coex Cellular Core vent pipe: Every 3 feet (0.9 m). • For Schedule 40, 3" PVC, ABS, Coex Cellular Core vent pipe: Every 3.5 fee[...]
-
Page 19
19 VENTING The vent system must terminate so that proper clearances are maintained as cited in local codes or the current edition of the Natural Gas and Propane Installation Code CAN/CSA B149.1 as follows: 1 . The exit terminals of a mechanical vent system shall be not less than 7 feet (2.13 m) above grade when located adjacent to public walkways, [...]
-
Page 20
20 FIGURE 23. This unit can vent through 2", 3" or 4" nonmetallic pipe and fittings. The vent pipe installation can be started from either the blower discharge or the termination wall. Keep in mind the total vent system (pipe and elbows) when installing the vent system, see VENTING AND INST ALLA TION AND MAXIMUM VENT LENGTHS, pages 1[...]
-
Page 21
21 VENT PIPE PREP ARA TION 1. INITIAL PREP ARA TION A. Make sure the solvent cement you are planning to use is designed for the specific application you are attempting. B . Know the physical and chemical characteristics and limitations of the PVC and CPVC piping materials that you are about to use. C . Know the reputation of your manufacturer and t[...]
-
Page 22
22 B . Deburring Use a knife, plastic pipe deburring tool, or file to remove burrs from the end of small diameter pipe. Be sure to remove all burrs from around the inside as well as the outside of the pipe. A slight chamfer (bevel) of about 10°- 15° should be added to the end to permit easier insertion of the pipe into the end of the fitting. Fai[...]
-
Page 23
23 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner . Do NOT try to light the burner by hand.[...]
-
Page 24
24 TEMPERA TURE REGULA TION HOT W A TER CAN SCALD: Water heaters are intended to produce hot water . W ater heated to a temperature that will satisfy sp ace heating, clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than oth[...]
-
Page 25
25 FOR YOUR INFORMA TION ST ART UP CONDITIONS CONDENSA TE Whenever the water heater is filled with cold water , some condensate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensate. This usually happens when: a . A new water heater is filled with cold water for the first time. b . Burning ga[...]
-
Page 26
26 SER VICE AND ADJUSTMENT VENTING SYSTEM INSPECTION At least once a year a visual inspection should be made of the venting system. Y ou should look for: 1. Obstructions which could cause improper venting. The combustion and ventilation air flow must not be obstructed. 2 . Damage or deterioration which could cause improper venting or leakage of com[...]
-
Page 27
27 ANODE ROD INSPECTION The anode rod is used to protect the tank from corrosion. Most hot water tanks are equipped with an anode rod. The submerged rod sacrifices itself to protect the tank. Instead of corroding the tank, water ions attack and eat away the anode rod. This does not affect the water’s taste or color . The rod must be maintained to[...]
-
Page 28
28 LEAKAGE CHECKPOINTS Use this guide to check a “Leaking” water heater . Many suspected “Leakers” are not leaking tanks. Often the source of the water can be found and corrected. If you are not thoroughly familiar with gas codes, your water heater , and safety practices, contact Maytag Customer Service (1-800-788-8899) to check the water h[...]
-
Page 29
29 TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES These guidelines should be used by a qualified Maytag Customer Service Center Agent. Call the Mayt ag Customer Service Center at 1-800-788-8899 for assistance. Inform the associate that this is a “Flammable V apor Ignition Resistant” Product. PROBLEM SOLUTION An open earth ground circuit [...]
-
Page 30
30 TROUBLESHOOTING GUIDELINES These guidelines should be used by a qualified Maytag Customer Service Center Agent. Call the Maytag Customer Service Center at 1-800-788-8899 for assistance. Inform the associate that this is a “Flammable V apor Ignition Resistant” Product.[...]
-
Page 31
31 MA YT AG GAS W A TER HEA TER MODEL NO’S HVN41240PCGA 40 Gallon Natural Gas HVN41250PCGA 50 Gallon Natural Gas HVN41250VCGA 50 Gallon Natural Gas HVP41240PCGA 40 Gallon Propane (L.P .) HVP41250PCGA 50 Gallon Propane (L.P .) HVP41250VCGA 50 Gallon Propane (L.P . ) REP AIR P ARTS LIST Now that you have purchased your gas water heater , should a n[...]
-
Page 32
32 FULL ONE YEAR W ARRANTY For one year from the date of original retail purchase, any part which fails in normal home use will be repaired or replaced free of charge. If a leak occurs in the tank, a new water heater of the closest capacity and quality then available, will be replaced free of charge. The warranty of the replacement is the balance o[...]