Measurement Specialties PCI-DAS1002 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 26 pages
- 1.77 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Scanner
Measurement Specialties 9116
143 pages 1.85 mb -
Network Card
Measurement Specialties PCI-DAS1002
26 pages 1.77 mb -
Computer Hardware
Measurement Specialties PCI-CTR05
21 pages 0.84 mb -
Computer Hardware
Measurement Specialties CIO-SSH16
32 pages 0.69 mb -
Computer Hardware
Measurement Specialties PCI-DAS64/M2/16
36 pages 2.52 mb -
Computer Hardware
Measurement Specialties PCI-DIO24
20 pages 1.31 mb -
Network Card
Measurement Specialties PC-CARD-DAS16/12AO
27 pages 1.39 mb -
Computer Hardware
Measurement Specialties PCI-QUAD-AC5
24 pages 1.34 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Measurement Specialties PCI-DAS1002. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Measurement Specialties PCI-DAS1002 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Measurement Specialties PCI-DAS1002 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Measurement Specialties PCI-DAS1002 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Measurement Specialties PCI-DAS1002
- nom du fabricant et année de fabrication Measurement Specialties PCI-DAS1002
- instructions d'utilisation, de réglage et d’entretien de l'équipement Measurement Specialties PCI-DAS1002
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Measurement Specialties PCI-DAS1002 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Measurement Specialties PCI-DAS1002 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Measurement Specialties en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Measurement Specialties PCI-DAS1002, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Measurement Specialties PCI-DAS1002, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Measurement Specialties PCI-DAS1002. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
[...]
-
Page 2
PCI-DAS1002 Multifunction Analog & Digit al I/O User's Guide Document Revision 4, July, 2007 © Copyright 2007 , Measurement Computing Co rporation[...]
-
Page 3
Your new Measurement Computing produc t comes with a fantastic extra — Management committed to your satisfaction! Refer to www.mccdaq.com/execteam.html for the names, titles, an d contact inform ation of each ke y executive at Measurement Computing. Thank you for choosing a Measurement Co mputing product— and congratulations! You own the f ines[...]
-
Page 4
Trademark and Copyright Information TracerDAQ, Universal Library, Harsh E nvironment Warranty , Measurement Compu ting Corporation, an d the Measurement Computing logo are either trademarks or registered trademarks of M easurement C omputing Corporation. Windows, Microsoft, and Visual Studio ar e either trad emar ks or registered trademarks of Micr[...]
-
Page 5
Table of Contents Preface About this U ser's Gu ide .......................................................................................................................7 What you will learn from this user's guide ..................................................................................... .................... 7 Conventions in [...]
-
Page 6
PCI-DAS1002 User's Manual Miscella neous ................................................................................................................................................... 22 Power consumption .............................................................................................................. ........................[...]
-
Page 7
Preface About this User's Guide What you will learn from this user's guide This user's guide explain s how to inst all, confi gure, and us e the PCI-DAS 1002 so that y ou get the most out of its analog, digital, and timing I/O features. This user's guide also re fers you to related docum ents availa ble on our we b site, and t o[...]
-
Page 8
Chapter 1 Introducing the PCI-DAS1002 Overview: PCI-DAS1002 features This manual explains how to install and u se the PCI-DAS1002. This board is a multifunctio n analog and digital I/O board desi gned f or the PCI bus. The PCI-DAS1002 p rovides either 16 single-ended or eight differential analog inputs. Input ranges are software-selectable as eith [...]
-
Page 9
PCI-DAS1002 User's Manual Introducing the PCI-DAS1002 PCI-DAS1002 block diagram PCI-DAS1002 functions are illustrated in the block diagram shown here. Figure 1. PCI-DAS1002 function al block diagram 9[...]
-
Page 10
Chapter 2 Installing the PCI-DAS1002 What is included with your PCI-DAS1002 As you unpack your board, make s ure each of the items shown bel ow is included: Hardware PCI-DAS1002 Additional documentation In addition to this hard ware user's guide, you shoul d also receive the Quick Start Guide (available in PDF at www.mccdaq.c om/PDFma nual[...]
-
Page 11
PCI-DAS1002 User's Manual Installing the PCI-DAS1002 Signal termination a nd conditioning accessories MCC provides signal terminatio n and conditioning products for use with the PCI-D AS1002. Refer to the " Field wiring and signal ter mination " section for a complete list of com patible accessory products. Unpacking the PCI-DAS1[...]
-
Page 12
PCI-DAS1002 User's Manual Installing the PCI-DAS1002 Configuring the hardware All hardware configuration options on the PCI-DAS1002 are software c ontrolled. You can select s ome of the configuration op tions using Insta Cal, such as the analog input conf igurat ion (16 si ngle-ended o r eight different ial channels ), and the source for t he [...]
-
Page 13
PCI-DAS1002 User's Manual Installing the PCI-DAS1002 Pinout – main I/O connector 8-channel differential mode Signal Name Pin Pin Signal Name GND 100 • • 50 GND N/C 99 • • 49 N/C N/C 98 • • 48 PC +5V N/C 97 • • 47 N/C N/C 96 • • 46 N/C A/D Int. Pacer Output 95 • • 45 A/D External Trigger N/C 94 • • 44 N/C N/C 93 ?[...]
-
Page 14
PCI-DAS1002 User's Manual Installing the PCI-DAS1002 16-channel single- ended mode Signal Name Pin Pin Signal Name GND 100 • • 50 GND N/C 99 • • 49 N/C N/C 98 • • 48 PC +5V N/C 97 • • 47 N/C N/C 96 • • 46 N/C A/D Int. Pacer Output 95 • • 45 A/D External Trigger In N/C 94 • • 44 N/C N/C 93 • • 43 N/C PC -12V 92 ?[...]
-
Page 15
PCI-DAS1002 User's Manual Installing the PCI-DAS1002 Cables 1 50 2 49 51 100 52 99 100 50 51 1 Key Key The re d stri pe ide nt i fi es pi n # 1 The r ed stripe iden ti fies pi n # 51 Ca ble is la be led “Pins 5 1-100 ”. Cable i s lab eled “Pins 1- 50”. Figure 2. C100FF- x cable Field wiring and signal termination The following MCC scre[...]
-
Page 16
Chapter 3 Programming and Developing Applications After following the installatio n instructions in Ch apter 2 , your board should now be inst alled and ready for use. Although the b oard is part of the larger D AS family , in general there may be no c orrespondence among registers for different boards. Software written at the reg ister level for o[...]
-
Page 17
Chapter 4 Calibrating the Board Introduction Calibrate the board u sing the Insta Cal utility after the board has fully warmed up. The reco mmended warm-up time is 15 m inutes. For best results, cal ibrate the boa rd immedi ately before m aking critical measurements. T he high resolution analog componen ts on the board are sensitive to temperature.[...]
-
Page 18
Chapter 5 Specifications Typical for 25 °C unless other wise specified. Specifications in italic text are guarantee d by design. Analog input Table 1. Analog input specifications Parameter Specification A/D converter type ADS7800 or equivalent Resolution 12 bits Number of channels 16 single-ended / 8 differential, software s electable Input ranges[...]
-
Page 19
PCI-DAS1002 User's Manual Specifications Accuracy Accuracies are l isted for a 20 0 kHz sam pling rate, 10 0 sample avera ge, single cha nnel operation, a 15 mi nute warm-up, and operational temperatures with in ±2 ° C of internal calibration temperature. Th e calibrator test source high side is tied to Channel 0 In and the low side is tied [...]
-
Page 20
PCI-DAS1002 User's Manual Specifications Analog output Table 6. Analog output specifications D/A converter type AD7847AR or equivalent Resolution 12 bits Number of channels 2 Configuration Voltage output, single-ended Output range ±10 V, ±5 V, 0 to 10 V, or 0 to 5 V. Soft ware selectable . Each ch annel independently programmable. D/A pacing[...]
-
Page 21
PCI-DAS1002 User's Manual Specifications Counters Table 9. Counter specific ations Parameter Specification Counter type 82C54 Configuration Two 82C54 devices. 3 down counters per 82C54, 16 bits ea ch Counter 0 - ADC residual sample counter Source: ADC Clock Gate: Internal programmable source Output: End-of-Acquisition interrupt Counter 1 - ADC[...]
-
Page 22
PCI-DAS1002 User's Manual Specifications Digital input/output Table 10. DIO specifications Digital type 82C55 Number of I/O 24 (FIRSTPORTA Bit 0 through FIRSTPORTC Bit 7) 2 banks of 8 and 2 banks of 4 or 3 banks of 8 or Configuration 2 banks of 8 with handshake Input high voltage 2.0 V min, 5.5 V absolute max Input low voltage 0.8 V max, –0.[...]
-
Page 23
PCI-DAS1002 User's Manual Specifications Connector and pin out Table 16. Main connector specificatio ns Connector type 100-pin high-density Robinson Nugent Compatible cable C100FF-x, unshielde d ribbon cab le. x = length in feet Compatible accessory products (with C100FF-x cable) ISO-RACK16/P ISO-DA02/P CIO-ERB24 (DADP-5037 adaptor required) C[...]
-
Page 24
PCI-DAS1002 User's Manual Specifications 16-channel single-ended mode pin out Pin Signal Name Pin Signal Name 1 LLGND 51 FIRSTPORTA Bit 0 2 CH0 HI 52 FIRSTPORTA Bit 1 3 CH8 HI 53 FIRSTPORTA Bit 2 4 CH1 HI 54 FIRSTPORTA Bit 3 5 CH9 HI 55 FIRSTPORTA Bit 4 6 CH2 HI 56 FIRSTPORTA Bit 5 7 CH10 HI 57 FIRSTPORTA Bit 6 8 CH3 HI 58 FIRSTPORTA Bit 7 9 C[...]
-
Page 25
Declaration of Conformity Manufacturer: Measurement Computing C orporation Address: 10 Commerce Way Suite 1008 Norton, MA 02766 USA Category: Electrical equi pment for m easur ement, cont rol and laboratory use. Measurement Computing Corporation declares under sole respo nsibility that the product PCI-DAS1002 to which this declaration relates is in[...]
-
Page 26
Measurement Computing Cor poration 10 Comme rce Wa y Suite 1008 Norton, Massachusetts 02766 (508) 946-5100 Fax: (508) 946-9500 E-mail: info@mccdaq.com www.mccdaq.co m[...]