Metrologic Instruments MS6130 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 45 pages
- 0.33 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Scanner
Metrologic Instruments MS9500
50 pages 0.45 mb -
Scanner
Metrologic Instruments MS7120 Series
48 pages 0.71 mb -
Scanner
Metrologic Instruments MS9500 Voyager
56 pages 2.19 mb -
Scanner
Metrologic Instruments MS7100
45 pages 1.24 mb -
Scanner
Metrologic Instruments MS860i
55 pages 0.54 mb -
Scanner
Metrologic Instruments MS7620
59 pages 4.47 mb -
Scanner
Metrologic Instruments MS2221
68 pages 11.32 mb -
Scanner
Metrologic Instruments IS6520 Series
44 pages 6.76 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Metrologic Instruments MS6130. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Metrologic Instruments MS6130 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Metrologic Instruments MS6130 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Metrologic Instruments MS6130 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Metrologic Instruments MS6130
- nom du fabricant et année de fabrication Metrologic Instruments MS6130
- instructions d'utilisation, de réglage et d’entretien de l'équipement Metrologic Instruments MS6130
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Metrologic Instruments MS6130 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Metrologic Instruments MS6130 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Metrologic Instruments en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Metrologic Instruments MS6130, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Metrologic Instruments MS6130, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Metrologic Instruments MS6130. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
METROLOGIC INSTRUMENTS, INC. MS6130 Hand Held Laser Scanner and MX003 Scanner Interfaces Installation and User’s Guide[...]
-
Page 2
ii L OCATIONS North America Headquarters Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO 90 Coles Road Tel: 856-228-8100 Blackwood, NJ 08012-4683 Email: info@metrologic.com Website: www.metrologic.com Germany Metrologic Instruments GmbH Tel: 49-89-89019-0 Dornierstrasse 2 Fax: 49-89-89019-200 82178 Puchheim b. Email: info@europe.metro[...]
-
Page 3
iii T ABLE OF C ONTENTS MS6130 Hand Held Bar Code Scanner ..................................................... 1 MX003 Series Scanner Interfaces ............................................................. 2 Unpacking List ......................................................................................... 3 Connections of the “MX” Inter[...]
-
Page 4
iv T ABLE OF C ONTENTS (C ONTINUED ) Maintenance .......................................................................................... 27 Troubleshooting ..................................................................................... 28 Appendix A Specifications ........................................................................... [...]
-
Page 5
1 T HE MS6130 H AND H ELD B AR C ODE S CANNER MS6130 Hand Held Bar Code Scanners are wireless scanners with a mobility range of up to 30 feet from the receiver. When not in use, the scanner rests in a universal-charging stand. The scanner will be fully charged in 2 hours when not scanning in the stand. A fully charged MS6130 can provide up to 8 hou[...]
-
Page 6
2 MX003 S ERIES S CANNER I NTERFACES Metrologic’s MX003 Series Scanner Interfaces provide a short range, one- way wireless data communication link between a remote portable scanner and an RS-232 or light pen host device. Specifically, Metrologic’s MS6130 Hand -Held Laser Scanners include a Liberty ® RF transmitter board . Metrologic’s MS700i[...]
-
Page 7
3 U NPACKING L IST Your shipment will contain a set of items from the two groups listed below: Transmitter Group: • MS6130 Hand-Held Scanner • Stand #45880 (optional) • Stand #45558, 45559 and 45560 (optional) • MS4120 Programming Guide Receiver Group: • “MX” Scanner Interface • MCA951 adapter or adapter cable (if required) • Regu[...]
-
Page 8
4 C ONNECTIONS OF THE “MX” I NTERFACE TO THE H OST D EVICE Except version 17 1. Turn off the host system. 2. Connect the MCA to the host device. Connect the “MX” interface to the MCA. 3. Check the AC input requirements of the trans former to make sure the voltage matches the AC outlet. The socket outlet should be near the equipment and easi[...]
-
Page 9
5 C ONNECTIONS OF THE K EYBOARD W EDGE “MX” I NTERFACE TO THE PC Version 17 only MX003 Scanner Interfaces with a suffix of “17" are Keyboard Wedge versions used to interface with a PC and keyboard. 1. Turn off the PC. 2. Plug the “MX” receiver adapter cable to the PC keyboard port. 3. Plug the keyboard into the “MX” receiver adap[...]
-
Page 10
6 C ONNECTIONS OF THE MS700 I /MS720 I WITH “MX” TO THE H OST D EVICE To avoid potential problems, do not power up the scanner until the communication cable is secured to the host . 1. Turn off the host system. 2. Connect the 25-pin D-type connector on the MS700i/MS720i scanner’s head cable to the communication cable. Connect the other end of[...]
-
Page 11
7 C ONFIGURATION OF THE MS700 I /MS720 I WITH “MX” To perform matching procedure refer to page 18. Once the transmitter is assigned an ID number, configure the S700i/MS720i to accept RF communication. Although the changes made in this section effect the receiver, the MS6130 performs all scanning. 1. Scan the following bar code to enter the rece[...]
-
Page 12
8 C ONFIGURATION OF THE MS700 I /MS720 I WITH “MX” TO THE H OST S YSTEM To perform matching procedure refer to page 18. Before the MS700i/MS720i scanner ships from the factory, the factory programs the scanner to a group of default settings noted in the ScanSelect™ Scanner Programming Guide. An asterisk marks each default setting. The asteris[...]
-
Page 13
9 C ONFIGURATION OF THE “MX” TO THE S CAN P AL ® D ATA C OLLECTOR To perform matching procedure refer to page 18. The RS-232 parameters marked with an asterisk ( * ) in the charts are the default settings of the “MX”. The charts are in the Default Settings of the MS6130 and “MX” Receiver section of this guide. To communicate with each [...]
-
Page 14
10 C ONFIGURATION OF THE “MX ” TO THE RS-232, L IGHT P EN OR K EYBOARD W EDGE H OST S YSTEM To perform matching procedure refer to page 18. The light pen, RS-232 and Keyboard Wedge parameters marked with an asterisk ( * ) in the charts are the default settings of the “MX”. The charts are in the Default Settings of the Transmitter and “MX?[...]
-
Page 15
11 K EYBOARD W EDGE (KB) I NTERFACE Scan the ENABLE KB WEDGE INTERFACE bar code if your communication requirement is keyboard emulation. The scanner will provide keyboard emulation by converting the scanned bar code data to the PC keyboard scan code equivalent. Enable Keyboard Wedge Interface R 2 4 KB Parameter - Keyboard Type The following bar cod[...]
-
Page 16
12 K EYBOARD W EDGE (KB) I NTERFACE (C ONTINUED ) KB Parameter – Keyboard Type The following bar codes are used to define the keyboard country type. If necessary, scan the appropriate bar code. ** USA Keyboard B R 8 UK Keyboard B R 2 France Keyboard B R 3 Germany Keyboard B R 4 Italy Keyboard B R 5 Spain Keyboard B R 6 Belgium Keyboard B R 1 IBM [...]
-
Page 17
13 K EYBOARD W EDGE (KB) I NTERFACE (C ONTINUED ) Reserved B R B Reserved B R C Reserved B R D Reserved B R E Reserved B R F KB Parameter - Caps Lock Mode When Caps Lock is used on the keyboard, choose ENABLE CAPS LOCK. Once enabled, the scanner will simulate Caps Lock keyboard input. This mode will not work with all keyboard types. Enable Caps Loc[...]
-
Page 18
14 K EYBOARD W EDGE (KB) I NTERFACE (C ONTINUED ) KB Parameter - Alt Mode When this option is enabled, the scanner will duplicate this keyboard sequence: Hold down the Alt key; type the decimal number that corresponds to the appropriate keyboard character. Caution should be observed when using Alt mode because a scanner to host application conflict[...]
-
Page 19
15 C ONFIGURATION OF THE MS6130 H AND -H ELD To perform matching procedure refer to page 18. Before the MS6130 scanner ships from the factory, the factory programs the scanners to a set of default settings. These default settings can be found in the MS4120 Programming Guide. The default settings have an asterisk that appears before the brief defini[...]
-
Page 20
16 E NABLING THE MS700 I /MS720 I S CANNER ’ S RF L OW S PEED O PTION Before beginning this procedure, perform all steps in the sections, Matching the Transmitter to the Receiver and Configuration of the MS700i/MS720i with “MX” . Use the MS700i/MS720i scanner to scan the following bar codes. 1. Temporarily cover the bar code below Step 3. Sca[...]
-
Page 21
17 C HANGING THE ID In order for the MS6130 to send data to the correct receiver, they must have a matching ID number. The ID number is the serial number of the receiver. When the matching procedure is completed, the receiver will accept data only from a MS6130 that has the matching ID number. Each receiver is programmed with its serial number befo[...]
-
Page 22
18 M ATCHING P ROCEDURE With the MS6130, scan the following bar codes starting from the top down: Transmitter Enter/Exit Program Mode * * Recall Defaults D F 1 Enable RF Communications R 3 5 Transmitter Enter/Exit Program Mode * * Locate the model label on the case of the receiver. Scan the serial number bar code. The receiver and MS6130 are now ma[...]
-
Page 23
19 P ARTS OF THE MS6130 H AND -H ELD B AR C ODE S CANNER Becoming familiar with the features of the MS6130 hand-held scanner will help when operating one of these scanners. The illustration and list explain the pertinent parts. Figure 4: Scanner Parts Battery Charge Contacts Receptacle for the battery charger. Reactivation Switch Turns the unit on [...]
-
Page 24
20 C OMPONENTS OF THE MS6130 S ERIES S TAND The following are the components used to build the MS6130 series stand (MLPN: 45880). 1. Cradle 2. Stand Charger Pack 3. Pole Cover 4. Flex pole 5. Stand Base Cover 6. Stand Base 7. Charger Transformer 8. Charger Pack Screws 9. Mounting Screws 10. Lock Washer 6 1 3 4 5 10 9 7 8 2 CABLE CONNECTS THROUGH OP[...]
-
Page 25
21 I NSTALLATION OF THE MS6130 S ERIES S TAND Refer to for numbered components on the previous page 1. Use the stand base (6) as a template to drill and mount the base to the counter using the mounting screws (9) provided. 2. Feed the wire from the transformer (7) through the slot in the base cover (5) approximately 9" of the wire. 3. Press th[...]
-
Page 26
22 I NSTALLATION OF THE 6000 S ERIES U NIVERSAL C HARGING S TAND MLPN: 45558 - 115V, 45559 - 230V and 45560 - 240V (UK) Figure 6: Universal Charging Stand P ERMANENT C OUNTER T OP I NSTALLATION 1. Separate weighted base from rotating base by removing the (4) four screws. 2. Use the rotating base as a drill template. 3. Use the (4) four wood screws [...]
-
Page 27
23 N I C D B ATTERY C HARGER WITH R ECONDITIONING F EATURE MLPN: 45561 - 115V and 45562 - 230V How to Recondition 1. Place the scanner into the charge stand. 2. Push the stand tilt cup in the extreme down position to expose the hole for the discharge cycle switch. 3. Use a pin to push the discharge cycle switch located beneath the hole. 4. When the[...]
-
Page 28
24 V ISUAL I NDICATORS The scanner has red and green LEDs. When the scanner is on, the LEDs indicate the status of the scan and scanner. No Red or Green The scanner will turn off if the scanner has been dormant for a specified time. To reactivate the unit, direct the output window up then down toward the bar coded product. If the unit has been dorm[...]
-
Page 29
25 A UDIBLE I NDICATORS When the scanner and “MX” receiver are in operation, they provide audible indications. These sounds indicate the status of the scan and scanner. One Beep When the “MX” Receiver first receives power, the unit will beep once. If the scanner successfully reads a bar code, the green light will flash. If the “MX” rece[...]
-
Page 30
26 A UDIBLE I NDICATORS (C ONTINUED ) The “MX” receiver can be programmed to emit three beeps when the timeout occurs during communication between the host and receiver. Refer to the MS4120 Programming Guide section, Audible Indicators for Communication Timeouts to program this feature. There are four settings available for the tone of the beep[...]
-
Page 31
27 L ABELS The MS6130 scanner is either a CDRH Class II laser system or an IEC Class 1 Laser System. Your unit will have a CDRH Class II caution label or LASERKLASSE 1 label affixed below the model number label. The model number/avoid exposure label is located on the bottom of the scanner’s head. The following are examples of these labels: M AINT[...]
-
Page 32
28 T ROUBLESHOOTING 1. The receiver can receive data from a MS6130 with its own ID or 10 zeroes. It’s own ID can be received all the time. When using 10 zeroes, the first scan the receiver gets must have 10 zeroes as its ID and from that point on the receiver will accept both ID’s. Power down the receiver. Using the MS6130, scan the bar codes f[...]
-
Page 33
29 A PPENDIX A Specifications RF Link Characteristics Frequencies: One of the following depending on the country of operation: 418MHz 434MHz 912MHz Bandwidth: 220kHz Modulation: FM Certification: No FCC licensing required RF Protocol: One way data transmission Transmission time at a maximum of 100 ms 50K baud data rate Dedicated transmitter(s) to r[...]
-
Page 34
30 A PPENDIX A (C ONTINUED ) MX003 Series Scanner Interface Specifications FCC ID: LW5003 Operating Voltage: 5Vdc Antenna: Integral Dimensions: 3.54" x 1.97" x 0 .94" Weight: 0.175 lb. UL Listed: US and Canada Model Number Operating Frequency Data Interface RS-232 Light Pen Data Interface Keyboard Wedge MX003 912 MHZ 3 MX003-17 912 M[...]
-
Page 35
31 A PPENDIX A (C ONTINUED ) Specifications of Battery Pack Battery Type: “AA” NiCd Rechargeable Configuration: 3 Batteries/Pack Nominal Voltage: 3.6 VDC Maximum Voltage: 4.8 VDC Capacity: 600 mA Charge Cycles: Over 500 Full Charge/Discharge Charge Time: 4 Hours Short Circuit Protection: Auto/Reset Fuse 1.7A Hold Current Temperature Characteris[...]
-
Page 36
32 A PPENDIX B Default Settings of the MS6130 and “MX” Receiver Before the MS6130 hand-held scanner and “MX” Receiver ships from the factory, the factory programs the scanners to a group of default settings. An asterisk ( * ) in the charts on the following pages marks the default settings of the units. If an asterisk is not in the default c[...]
-
Page 37
33 A PPENDIX B (C ONTINUED ) Parameter T - Transmitter R - Receiver Default RS-232 Light Pen Long Range Activation in the Stand T * 3 3 Normal Scan T * 3 3 Pulsing Scan T 3 3 Custom Scan T 3 3 Green LED Rescan Indicator T 3 3 Short Same Symbol Rescan T 3 3 Long Same Symbol Rescan T * 3 3 Alternate Beeper Tone 1 R 3 3 Alternate Beeper Tone 2 R * 3 3[...]
-
Page 38
34 A PPENDIX B (C ONTINUED ) Parameter T - Transmitter R - Receiver Default RS-232 Light Pen DTR Input R 3 Carriage Return R * 3 Line Feed R * 3 ETX Suffix R 3 Tab Prefix R 3 Tab Suffix R 3 Prefix ID for UPC/EAN R 3 Suffix ID for UPC/EAN R 3 Bars High R * 3 Spaces High R 3 Transmit as Scanned R * 3 Transmit as Code 39 R 3 Poll Light Pen 5 Volts R 3[...]
-
Page 39
35 A PPENDIX B (C ONTINUED ) PARAMETER T - TRANSMITTER R - RECEIVER DEFAULT KEYBOARD WEDGE Keyboard Type R 3 AT R * 3 XT R 3 PS2 R 3 Keyboard Country Type R 3 USA R * 3 UK R 3 France R 3 Germany R 3 Italy R 3 Spain R 3 Belgium R 3 KB4700 R 3 Swiss R 3 Caps Lock R 3 Autodetection R 3 User Defined R 3 Transmit Cleanup Bit R 3 Transmit Alt Mode R 3 Tr[...]
-
Page 40
36 A PPENDIX C MX003 Series Scanner Interface Pin Assignments The interfaces are equipped with a shielded, 10-pin modular jack manufactured by Steward Stamping. The mating connector is a Steward Stamping shielded plug #937-SP-361010. Caution should be used when working with cables for this port because there is typically power present for scanner i[...]
-
Page 41
37 A PPENDIX D Warranty and Disclaimer Limited Warranty The MS6130 scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS6130 scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS6130 scanners are free of all defects in material, workmanship [...]
-
Page 42
38 A PPENDIX E Notices Notice - applicable to 912 MHZ devices only This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any una[...]
-
Page 43
39 A PPENDIX F Patents “Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No. 4,930,848 ; 4,958,984; 5,081,342; 5,260,553; 5,340,971; 5,340,973; 5,424,525; 5,468,951; 5,484,992; 5,525,789; 5,528,024; 5,591,953; 5,616,908; 5,627,359; 5,661,292; 5,777,315; 5,789,730; 5,789,731; 5,808[...]
-
Page 44
40 I NDEX A AC 4, 6 Adapter 3 Asia ii Audible indicators 25, 26 B Battery pack 31 Beep(s) 1, 2, 6, 7, 9, 10, 16 17, 19, 23, 25, 26, 28 C Cable 3, 6 Changing ID 17 Clean 27 Clean-up bit 14 Compliance 4, 6, 31 Configuration(s) 7-10, 15, 16, 28 Connections 4, 6 Copyright ii Current 29 Customer Service ii D Default settings 32-35 Dimensions 29 Disclaim[...]
-
Page 45
41 I NDEX (C ONTINUED ) R Receiver board 2 Red LED 1, 19, 24, 25 Rights property 40 RS-232 9, 10, 28 S ScanPal ® 2, 3, 9 ScanSelect 3, 8, 32 Shipping carton 3 South America ii Specifications 29-31 Stand 3, 20-23 T Temperature 31 Tones 26 Transformer 4, 6, 20, 21 Transmitter 1-3, 7, 10, 15, 16, 18, 29, 32-35 Troubleshooting 28 U Unpacking list 3 US[...]