MGE UPS Systems EX15 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 18 pages
- 0.21 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Power Supply
MGE UPS Systems 1000 RT2U
126 pages 3.79 mb -
Power Supply
MGE UPS Systems EX-5, EX-7, EX-11RT
76 pages 3.66 mb -
Power Supply
MGE UPS Systems EX30
106 pages 2.06 mb -
Power Supply
MGE UPS Systems EX20Rack
24 pages 0.28 mb -
Power Supply
MGE UPS Systems EX30Rack
24 pages 0.28 mb -
Power Supply
MGE UPS Systems 1500 Tower
36 pages 0.66 mb -
Power Supply
MGE UPS Systems 3000 RT 3U
24 pages 0.67 mb -
Power Supply
MGE UPS Systems 800 Rack
196 pages 3.81 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation MGE UPS Systems EX15. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel MGE UPS Systems EX15 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation MGE UPS Systems EX15 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation MGE UPS Systems EX15 devrait contenir:
- informations sur les caractéristiques techniques du dispositif MGE UPS Systems EX15
- nom du fabricant et année de fabrication MGE UPS Systems EX15
- instructions d'utilisation, de réglage et d’entretien de l'équipement MGE UPS Systems EX15
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage MGE UPS Systems EX15 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles MGE UPS Systems EX15 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service MGE UPS Systems en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées MGE UPS Systems EX15, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif MGE UPS Systems EX15, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation MGE UPS Systems EX15. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Pulsar EX : 51032233XT/AC MGE UPS SYSTEMS Manuel d'utilisation User Manual Manual de instrucciones Pulsar TM EX7 / EX10 / EX15 EXB10 / EXB15 % ! … … … … … % … – + – +[...]
-
Page 2
Pulsar EX : 51032233XT/AC MGE UPS SYSTEMS 0 Thank you for purchasing the EX Uninterruptible Power Supply . The EX has been designed to provide many years of trouble-free operation. Please review the manual which has been prepared to provide you with all the necessary information concerning the installation and use of your EX . For service call 1-80[...]
-
Page 3
Pulsar EX : 51032233XT/AC MGE UPS SYSTEMS note c this equipment has been tested and found to comply with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy [...]
-
Page 4
Pulsar EX : 51032233XT/AC MGE UPS SYSTEMS Postal address: 1660 Scenic Avenue Costa Mesa, CA 92626 714-557-1636 51032233XT/AC MGE UPS SYSTEMS, Inc.[...]
-
Page 5
MGE UPS SYSTEMS Pulsar EX : 51032233XT/AC i ENGLISH IMPORT ANT SAFETY INSTRUCTIONS SA VE THESE INSTRUCTIONS This manual contains important instructions for Models EX7/EX10/EX15/EXB10/EXB15 that should be followed during installation and maintenance of the UPS batteries. c This equipment can be operated by any individual, with no previous training; [...]
-
Page 6
iv Pulsar EX : 51032233XT/AC MGE UPS SYSTEMS ENGLISH introduction In critical situations, count on MGE UPS SYSTEMS Pulsar EX7, EX10 and EX15 uninterruptible power supplies (UPS). Their protection keeps your data intact and accessible. Pulsar EX7, EX10 and EX15 UPSs ensure top quality power around the clock, and continue operations during power fail[...]
-
Page 7
MGE UPS SYSTEMS Pulsar EX : 51032233XT/AC v options c rack installation kit: this kit is used to install Pulsar EX7, EX10 and EX15 in a 19- inch rack. The kit is designed to receive two Pulsar EX7, EX10 and EX15 , or one Pulsar EX10/EX15 and a battery extension unit , thus offering up to 3000 VA of power; c UM Sensor environment measurement unit: c[...]
-
Page 8
vi Pulsar EX : 51032233XT/AC MGE UPS SYSTEMS software supplied with Pulsar EX7, EX10 and EX15 To meet the different operating environments of your UPS, Pulsar EX includes 2 MGE UPS SYSTEMS software programs: c EX-Driver software for Windows (on 3.5" diskettes); c Solution-Pac TM network software (on CD- ROM). EX-Driver for Windows EX Driver fo[...]
-
Page 9
Pulsar EX7/EX10/EX15/EXB10/EXB15 presentation présentation de Pulsar EX7/EX10/EX15/EXB10/EXB15 presentación de Pulsar EX7/EX10/EX15/EXB10/EXB15 general contents / sommaire général / sumario general Pulsar presentation ............................................................................................................................. 3 [...]
-
Page 10
3 Pulsar EX : 51032233XT/AC MGE UPS SYSTEMS 4 Pulsar EX : 51032233XT/AC MGE UPS SYSTEMS Pulsar EX7/EX10/EX15 Pulsar EX7/EX10 front view / vue avant / vista delantera rear view / vue arrière / vista trasera Pulsar EX15 Pulsar EXB10/EXB15 rear view / vue arrière / vista trasera rear view / vue arrière / vista trasera % ! … … … … … % … [...]
-
Page 11
MGE UPS SYSTEMS Pulsar EX : E-51032233XT/AC 11 contents getting started .................................................................................................................. 12 location ...................................................................................................................................... 12 preliminary c[...]
-
Page 12
12 Pulsar EX : E-51032233XT/AC MGE UPS SYSTEMS 8 0V n g I max 8.3A V ac OUT 7 ? e s s r e s to computer loads getting started location c observe the safety rules indicated at the beginning of this document. preliminary checks c check that the "on/off" button " " on the front is not pushed in; c check that rating shown on the rat[...]
-
Page 13
MGE UPS SYSTEMS Pulsar EX : E-51032233XT/AC 13 communication c the U-Talk communication port, at the rear of the Pulsar , delivers information in the form of an RS232 series link supported by the communication protocol exclusive to MGE UPS SYSTEMS. The Solution-Pac TM programs use the data made available by this protocol. option 2 c SNMP card: afte[...]
-
Page 14
14 Pulsar EX : E-51032233XT/AC MGE UPS SYSTEMS operation starting up with utility power present 17 s 7 s 5 s 0 s several beeps 1a to 1f on UPS is on utility power 1 s beep output off output off normal operation indicator lights test press button "on/off" : automatic sequence: your load is supported by the battery 1a to 1f flashing device [...]
-
Page 15
MGE UPS SYSTEMS Pulsar EX : E-51032233XT/AC 15 starting up with out utility power 17 s 7 s 5 s 0 s several beeps 1a to 1f on 1 s beep output off output off normal operation on battery indicator lights test press "on/off" button: automatic sequence: your load is supported by the battery 1a to 1f flashing UPS is on utility power device and [...]
-
Page 16
16 Pulsar EX : E-51032233XT/AC MGE UPS SYSTEMS operation on battery no utility power 1a to 1d indicating the battery recharge percentage: here, between 12 and 25% 1e indifferent 1f on silence your load is supplied by the utility power (on line) 1a to 1d indicating the load charge percentage: here 50% 1e off 1f on silence At whatever point the utili[...]
-
Page 17
MGE UPS SYSTEMS Pulsar EX : E-51032233XT/AC 17 overload utility power present 1a flashing 1d flashing 1e off 1f on 1 beep every second automatic load transfer to bypass operating anomalies device fault v v v v v automatic load transfer to bypass, v v v v v switch off Pulsar (release "on/off" button), disconnect from the wall socket (check[...]
-
Page 18
18 Pulsar EX : E-51032233XT/AC MGE UPS SYSTEMS[...]