Les manuels d’utilisation similaires
-
Power Supply
MGE UPS Systems 1500 Tower
36 pages 0.66 mb -
Power Supply
MGE UPS Systems EX 1000
28 pages 0.7 mb -
Power Supply
MGE UPS Systems Comet EX 11 RT 31
38 pages 1.53 mb -
Power Supply
MGE UPS Systems S 3000 RT 3U
22 pages 1.45 mb -
Power Supply
MGE UPS Systems S 1250 RT 2U, S 1750 RT 2U, 2000 RT 2U, S 2500 RT 2U, S 3000 RT 2U, S 3000 RT 3U, S EXB 1250/1750 RT 2U, S EXB 2500/3000 RT 2U, S EXB
22 pages 1.45 mb -
Power Supply
MGE UPS Systems Nova 600 AVR
13 pages 0.62 mb -
Power Supply
MGE UPS Systems 700
126 pages 3.79 mb -
Power Supply
MGE UPS Systems 300
6 pages 0.44 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation MGE UPS Systems EXB10Rack. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel MGE UPS Systems EXB10Rack ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation MGE UPS Systems EXB10Rack décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation MGE UPS Systems EXB10Rack devrait contenir:
- informations sur les caractéristiques techniques du dispositif MGE UPS Systems EXB10Rack
- nom du fabricant et année de fabrication MGE UPS Systems EXB10Rack
- instructions d'utilisation, de réglage et d’entretien de l'équipement MGE UPS Systems EXB10Rack
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage MGE UPS Systems EXB10Rack ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles MGE UPS Systems EXB10Rack et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service MGE UPS Systems en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées MGE UPS Systems EXB10Rack, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif MGE UPS Systems EXB10Rack, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation MGE UPS Systems EXB10Rack. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Pulsar EX Rack : 86-153522-00 MGE UPS SYSTEMS User Manual Pulsar TM EX10 Rac k / EX15 Rac k EXB10 Rac k ! … – + – + … … … … % % www.mgeups.com[...]
-
Page 2
Pulsar EX Rack : 86-153522-00 MGE UPS SYSTEMS Thank you f or purchasing the EX Rack Uninterruptible P o wer Supply . The EX Rack has been designed to provide man y years of trouble-free operation. Please re view the manual which has been prepared to provide you with all the necessary information concerning the installation and use of your EX Rack .[...]
-
Page 3
MGE UPS SYSTEMS Pulsar EX Rack : 86-153522-00 i IMPOR T ANT SAFETY INSTR UCTIONS SA VE THESE INSTR UCTIONS This manual contains important instructions for Models EX10 Rack /EX15 Rack /EXB10 Rack /EXB15 that should be followed during installation and maintenance of the UPS batteries. c This equipment can be operated by any individual, with no previo[...]
-
Page 4
ii Pulsar EX Rack : 86-153522-00 MGE UPS SYSTEMS introduction In critical situations, count on MGE UPS SYSTEMS Pulsar EX10 Rack and EX15 Rack uninterruptible power supplies (UPS). Their protection keeps your data intact and accessible. Pulsar EX10 Rack and EX15 Rack UPSs ensure top quality power around the clock, and continue operations during powe[...]
-
Page 5
MGE UPS SYSTEMS Pulsar EX Rack : 86-153522-00 iii options c UM Sensor environment measurement unit: compatible with SNMP or Solution Pac TM , this unit measures the temperature and the relative humidity in the room where the Pulsar is installed. Eight relay contacts are provided to transmit signals to an administration platform, in the form of volt[...]
-
Page 6
iv Pulsar EX Rack : 86-153522-00 MGE UPS SYSTEMS software supplied with Pulsar EX10 Rack and EX15 Rack To meet the different operating environments of your UPS, Pulsar EX Rack includes 2 MGE UPS SYSTEMS software programs: c EX-Driver software for Windows; c Network based Solution-Pac TM power management software. EX-Driver for Windows EX Driver for[...]
-
Page 7
Pulsar EX10 Rac k / EX15 Rac k / EXB10 Rac k / EXB15 presentation general contents Pulsar presentation ............................................................................................................................. 3 getting started / operation ...........................................................................................[...]
-
Page 8
3 MGE UPS SYSTEMS 4 MGE UPS SYSTEMS Pulsar EXB10 Rack rear view Pulsar EX10 Rack : 86-153522-00 Pulsar EX10 Rack : 86-153522-00 Pulsar EX10 Rack EX15 Rack front view Pulsar EX10 Rack EX15 Rack rear view 1d 1b 1c 1f 1e 1a 2 3 ! … – + – + … … … … % % 18 MGE UPS SYSTEMS ATTN: CUST OMER SUPPORT SERVICES 1660 SCENIC A VENUE COSTA MESA, CA [...]
-
Page 9
MGE UPS SYSTEMS Pulsar EX Rack : 86-153522-00 5 key to diagrams 2 "function" button: switches off audio warning device or measures load charge percentage (if utility power present), 3 "ON/OFF" switch: button pushed in: ON button not pushed in: OFF, 4 input receptacle, 5 input cord (supplied , with ferrite for Pulsar EX15 Rack ) [...]
-
Page 10
6 P-ulsar EX Rack : 86-153522-00 MGE UPS SYSTEMS technical data c output power: v Pulsar EX10 Rack : 1000VA/700W v Pulsar EX15 Rack : 1500VA/1050W c input voltage: v Pulsar EX10 Rack voltage (V): a 80V to 138V single phase ( 60V to 138V at 1/3 Power, 70V to 138V at 2/3 Power) v Pulsar EX15 Rack voltage (V): a 90V to 138V single phase ( 70V to 138V [...]
-
Page 11
MGE UPS SYSTEMS Pulsar EX Rack : 86-153522-00 7 Pulsar EX10 Rack battery back-up time Pulsar EX15 Rack battery back-up time t (min) 0 50 100 150 200 A TM switch 32 slots 2 entry level servers tower server + e xternal mass storage / A TM switch 16 slots tower server + modular hub tower server 100 lines PBX desktop server entry level mini-computer sy[...]
-
Page 12
8 P-ulsar EX Rack : 86-153522-00 MGE UPS SYSTEMS[...]
-
Page 13
MGE UPS SYSTEMS Pulsar EX Rack : 86-153522-00 9 contents getting started .................................................................................................................. 10 location ...................................................................................................................................... 10 preliminary [...]
-
Page 14
10 Pulsar EX Rack : 86-153522-00 MGE UPS SYSTEMS getting started location c observe the safety rules indicated at the beginning of this document. preliminary checks c check that button 3 " " on the front is not pushed in; c check that rating shown on identification plate 9 corresponds to the input voltage specification and power requireme[...]
-
Page 15
MGE UPS SYSTEMS Pulsar EX Rack : 86-153522-00 11 communication c the U-Talk communication port, at the rear of the Pulsar , delivers information in the form of an RS232 series link supported by the communication protocol exclusive to MGE UPS SYSTEMS. The Solution-Pac TM programs use the data made available by this protocol. option 2 c SNMP card: af[...]
-
Page 16
12 Pulsar EX Rack : 86-153522-00 MGE UPS SYSTEMS operation starting up with utility power present 17 s 7 s 5 s 0 s several beeps UPS is on utility power 1 s beep output off output off normal operation indicator lights test press button "on/off" : automatic sequence: your load is supported by the battery device and battery test indicating [...]
-
Page 17
MGE UPS SYSTEMS Pulsar EX Rack : 86-153522-00 13 starting up with out utility power 17 s 7 s 5 s 0 s several beeps 1 s beep output off output off normal operation on battery indicator lights test press "on/off" button: automatic sequence: your load is supported by the battery UPS is on utility power device and battery test indicating the [...]
-
Page 18
14 Pulsar EX Rack : 86-153522-00 MGE UPS SYSTEMS operation on battery no utility power your load is supplied by the utility power (on line) At whatever point the utility power returns, Pulsar switches to normal operation: return of utility power load charge percentage Note: The alarm silence button is to deactivate or activate the audio warning dev[...]
-
Page 19
MGE UPS SYSTEMS Pulsar EX Rack : 86-153522-00 15 overload utility power present automatic load transfer to bypass operating anomalies device fault v v v v v automatic load transfer to bypass, v v v v v switch off Pulsar (release "on/off" button), disconnect from the wall socket (check input cord), and check that Pulsar has not short- circ[...]
-
Page 20
16 Pulsar EX Rack : 86-153522-00 MGE UPS SYSTEMS[...]
-
Page 21
Pulsar EX Rack : 86-153522-00 MGE UPS SYSTEMS service and factory repair - call 1 - 800 - 523 - 0142 c direct questions about the operation, repair, or servicing of this equipment to MGE UPS SYSTEMS, Inc. Customer Support Services. Include the part number, assembly number, and serial number of the unit in any correspondence. Should you require fact[...]
-
Page 22
Pulsar EX Rack : 86-153522-00 MGE UPS SYSTEMS Postal address: 1660 Scenic Avenue Costa Mesa, CA 92626 714-557-1636 86-153522-00 MGE UPS SYSTEMS, Inc. www.mgeups.com[...]