Miller Electric XMT 4-Rack manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 24 pages
- 0.57 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Welder
Miller Electric R-115
36 pages 1.33 mb -
Welder
Miller Electric 440
24 pages 0.5 mb -
Welder
Miller Electric XMT 400
36 pages 1.11 mb -
Welder
Miller Electric GA-16C
12 pages 0.43 mb -
Welder
Miller Electric MARKVI
4 pages 0.63 mb -
Welder
Miller Electric S-62
36 pages 1.33 mb -
Welder
Miller Electric 852
36 pages 1.34 mb -
Welder
Miller Electric DVI-2 R
48 pages 1.56 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Miller Electric XMT 4-Rack. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Miller Electric XMT 4-Rack ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Miller Electric XMT 4-Rack décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Miller Electric XMT 4-Rack devrait contenir:
- informations sur les caractéristiques techniques du dispositif Miller Electric XMT 4-Rack
- nom du fabricant et année de fabrication Miller Electric XMT 4-Rack
- instructions d'utilisation, de réglage et d’entretien de l'équipement Miller Electric XMT 4-Rack
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Miller Electric XMT 4-Rack ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Miller Electric XMT 4-Rack et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Miller Electric en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Miller Electric XMT 4-Rack, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Miller Electric XMT 4-Rack, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Miller Electric XMT 4-Rack. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Processes Description Multiprocess W elding Mounting Rack For Up T o Four XMT 300 W elding Power Sources With AUT O-LINK And Requiring 230/460 V olt Input Power OM-815 October 1994 Eff. w/Serial Number KC310301 XMT 4-Rack R Visit our website at www.MillerWelds.com[...]
-
Page 2
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .MillerW eld[...]
-
Page 3
Miller offers a T echnical Manual which provides more detailed service and parts information for your unit. T o obtain a T echnical Manual, contact your local distributor . Y our distributor can also supply you with W elding Process Manuals such as SMAW , GT AW , GMAW , and GMAW -P . For practical information on welding, process applica- tions, and[...]
-
Page 4
[...]
-
Page 5
OM-815 Page 1 SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING som _nd_5/97 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message. . Means “Note”; not safety related. This group of symbols means W arning! Watch O[...]
-
Page 6
OM-815 Page 2 Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld. ARC RA YS can burn eyes and skin. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.1 and Z87[...]
-
Page 7
OM-815 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring – be sure power supply system is properly sized, rated, and protected to handle this unit. F A[...]
-
Page 8
OM-815 Page 4 1-5. EMF Information Considerations About W elding And The Effects Of Low Frequency Electric A n d M a g netic Fields W elding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of[...]
-
Page 9
OM-815 Page 5 SECTION 2 – SAFETY INFORMA TION mod1.1 2/93 Read all safety messages throughout this manual. Obey all safety messages to avoid injury . Learn the meaning of W ARNING and CAUTION. 1 Safety Alert Symbol 2 Signal Word W ARNING means possible death or serious injury can happen. CAUTION means possible minor injury or equipment damage can[...]
-
Page 10
OM-815 Page 6 SECTION 4 – INST ALLA TION 4-1. Selecting A Location And Moving Rack W ARNING ELECTRIC SHOCK can kill. • Do not touch live electrical parts. • Disconnect input power conductors from de- energized supply line BEFORE moving rack. FIRE OR EXPLOSION can result from placing unit on, over , or near com- bustible surfaces. • Do not l[...]
-
Page 11
OM-815 Page 7 4-3. W elding Power Source Input Power Connections W ARNING ELECTRIC SHOCK can kill. • Do not touch live electrical parts. • T urn Of f welding power source, and disconnect input power to rack before inspecting or installing. • Have only qualified persons install unit. • Installation must meet National Electrical Code and all [...]
-
Page 12
OM-815 Page 8 4-4. Common Work Connections ELECTRIC SHOCK can kill. • Do not touch live electrical parts. • T urn Off welding power sources by placing Power circuit breakers in the Of f position before making any weld output connections. • Do not connect welding output of dif ferent polarities to the same structure. • See ANSI Z49.1 and OSH[...]
-
Page 13
OM-815 Page 9 4-5. Paralleling W elding Power Sources For SMA W ELECTRIC SHOCK can kill. • Do not touch live electrical parts. • T urn Off welding power sources by placing Power circuit breakers in the Of f position before making any weld output connections. • Do not connect welding output of dif ferent polarities to the same structure. • S[...]
-
Page 14
OM-815 Page 10 4-6. Connecting Input Power T o Rack W ARNING ELECTRIC SHOCK can kill. • Do not touch live electrical parts. • T urn Of f welding power sources before inspecting or installing rack. • Have only qualified persons install rack. • Installation must meet National Electrical Code and all other codes. swarn3.1* 2/93 Have only quali[...]
-
Page 15
Ref. S-0092-G OM-815 Page 1 1 T able 4-2. Electrical Service Requirements* Input V oltage 230 460 Recommended Standard Fuse Or Circuit Breaker Rating In Amperes 1 250 125 Input Conductor Size In A WG/Kcmil 2 1/0 4 Max Input Conductor Length In Feet (Meters) 3 229 (70) 397 (121) Grounding Conductor Size In A WG/Kcmil 4 4 6 * These values are calcula[...]
-
Page 16
OM-815 Page 12 5-2. Overload Protection 1 Power Circuit Breakers CB1-CB4 Each Power circuit breaker CB1 through CB4 protects the welding power source connected to it from overload. If a Power circuit breaker opens, th e matching welding power source would shut down. Manually reset the Power circuit breaker . ST-158 333 / Ref. ST -155 839 / Ref. ST-[...]
-
Page 17
OM-815 Page 13 SECTION 6 – ELECTRICAL DIAGRAM SA-155 857 Figure 6-1. Circuit Diagram For Rack Control Box[...]
-
Page 18
OM-815 Page 14 SECTION 7 – P ARTS LIST Description Part No. Item No. Figure 7-1. Main Assembly Quantity 1 155 878 COVER, top 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 032 473 GASKET , lift eye 1 . . . . . . . . . . . . . . . . . . . . . . . . . .[...]
-
Page 19
OM-815 Page 15 ST-158 152 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 12 11 23 22 21 20 19 18 17 . Hardware is common and not available unless listed. Figure 7-2. Control Box[...]
-
Page 20
OM-815 Page 16 Description Part No. Dia. Mkgs. Item No. Figure 7-2. Control Box (Fig 7-1 Item 14) Quantity 1 155 846 COVER, top control box 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 CB1-4 147 810 CIRCUIT BREAKER, mag 3P 60A 600V 4 . . . . . . . . . . . . . . . . . . .[...]
-
Page 21
Notes[...]
-
Page 22
Notes[...]
-
Page 23
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 7/00 Y o ur distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The expertise [...]
-
Page 24
PRINTED IN USA 2000 Miller Electric Mfg. Co. 6/00 Miller Elect ric Mfg. Co. An I l li noi s T ool Works Company 1635 W est Spencer Street Applet on, W I 5 4914 USA International He adquarters – US A USA Phone: 920-735-4505 Auto-A t t ended USA & C anada F AX : 9 20-735-4134 Int ernational F AX : 920-735-4125 European Headqua rters – Uni[...]