Mitsubishi Electronics 36FL manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 12 pages
- 0.86 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Air Conditioner
Mitsubishi Electronics PEA-RP140GAA
44 pages 5.07 mb -
Air Conditioner
Mitsubishi Electronics MSH-09RV
16 pages 2.77 mb -
Air Conditioner
Mitsubishi Electronics F920GOT-BBD-K-E
8 pages 0.28 mb -
Air Conditioner
Mitsubishi Electronics puhy-ep-yjm-a(-bs)
276 pages 21.43 mb -
Air Conditioner
Mitsubishi Electronics PEAD-A36AA
42 pages 5.96 mb -
Air Conditioner
Mitsubishi Electronics A12
8 pages 0.47 mb -
Air Conditioner
Mitsubishi Electronics MUZ-GE42VAD
96 pages 7.04 mb -
Air Conditioner
Mitsubishi Electronics PKA-A.HAL
52 pages 2.89 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Mitsubishi Electronics 36FL. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Mitsubishi Electronics 36FL ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Mitsubishi Electronics 36FL décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Mitsubishi Electronics 36FL devrait contenir:
- informations sur les caractéristiques techniques du dispositif Mitsubishi Electronics 36FL
- nom du fabricant et année de fabrication Mitsubishi Electronics 36FL
- instructions d'utilisation, de réglage et d’entretien de l'équipement Mitsubishi Electronics 36FL
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Mitsubishi Electronics 36FL ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Mitsubishi Electronics 36FL et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Mitsubishi Electronics en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Mitsubishi Electronics 36FL, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Mitsubishi Electronics 36FL, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Mitsubishi Electronics 36FL. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Air -Conditioner s PLH18, 24, 30, 36, 42AK PL12, 18, 24, 30, 36, 42AK PCH24, 30, 36, 42GK PC24, 30, 36, 42GK PKH18, 24, 30, 36FK3 PK12, 18, 24, 30, 36FK3 PKH18, 24, 30, 36FL PK18, 24, 30, 36FL3 OPERA TION MANU AL For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. FOR USER[...]
-
Page 2
2 s Before installing the unit, make sure you read all the “Safety precautions”. s The “Safety precautions” provide very important points regarding safety . Make sure you f ollow them. s If none of the above apply , turn the main switc h off and contact the dealer from whom y ou bought the air-conditioner , telling him the model name and th[...]
-
Page 3
3 ON/OFF – TIMER SET SET TEMP. REMOTE CONTROLLER MODE TIMER ON/OFF CLOCK/TIMER FAN SPEED AIR DISCHARGE FILTER AIR SWEEP CHECK TEST RUN STAND BY DEFROST DRY COOL AUTO FAN HEAT CENTRALLY CONTROLLED ˚ F SWING FAN SPEED AUTO RETURN NOT AVAILABLE ˚ F CHECK MODE FILTER TIMER TEST RUN TIMER OFF CLOCK AUTO AUTO CHECK SET TEMP. START STOP A 1 2. Operati[...]
-
Page 4
4 ON/OFF – TIMER SET SET TEMP. REMOTE CONTROLLER MODE TIMER ON/OFF CLOCK/TIMER FAN SPEED AIR DISCHARGE FILTER AIR SWEEP CHECK TEST RUN STAND BY DEFROST DRY COOL AUTO FAN HEAT CENTRALLY CONTROLLED ˚ F SWING FAN SPEED AUTO RETURN NOT AVAILABLE ˚ F CHECK MODE FILTER TIMER TEST RUN TIMER OFF CLOCK AUTO AUTO CHECK SET TEMP. START STOP F 1 2. Operati[...]
-
Page 5
5 C B D A ON/OFF – STAND BY DEFROST DRY COOL AUTOFAN HEAT CENTRALLY CONTROLLED ˚ F SWING FAN SPEED AUTO RETURN NOT AVAILABLE ˚ F CHECK MODE FILTER TIMER TEST RUN TIMER OFF CLOCKAUTOAUTO CHECKSET TEMP. STARTSTOP B A D C 3. Care and cleaning Caution: • Always turn off the po wer , first on the remote contr oller and then the main switch, before[...]
-
Page 6
6 4. T roubleshooting NOTE: After a po wer cut, the unit will not restart automatically . Y ou will have to restart it by pressing the PO WER - ON/OFF but ton on the remote controller . Wired remote controller s In any of the following cases, turn off the main power switch and contact your local dealer for service: •“ CHECK ” f ollowed b y ?[...]
-
Page 7
7 PLH18AK PLH24AK PLH30AK PLH36AK PLH42AK 18,000 24,000 30,000 35,400 42,000 19,000 [24,500/25,500] 26,000 [31,500/32,500] 33,000 [39,500/41,200] 38,000 [45,900/47,600] 44,300 [52,200/53,900] 11,000 [16,500/17,500] 16,500 [22,000/23,000] 18,500 [25,000/26,700] 23,000 [30,900/32,600] 26,800 [34,700/36,400] 1.75 2.57 3.17 3.63 3.98 1.59 [3.19/3.49] 2[...]
-
Page 8
8 PL12AK PL18AK PL24AK PL30AK PL36AK PL42AK 12,500 18,400 24,000 31,000 36,500 42,500 1.26 1.85 2.65 3.17 3.64 4.08 10.1 10.2 10.0 10.6 10.5 10.8 PL12AK PL18AK PL24AK PL30AK PL36AK PL42AK Galvanized sheets with gray heat insulation Munsell 0.7Y 8.59/0.97 115, 1, 60 15 2.0 3.0 1.2 2.6 420-560 530-710 710-990 780-1060 390-530 490-670 670-950 740-1020[...]
-
Page 9
9 PCH24GK PCH30GK PCH36GK PCH42GK 24,000 30,000 35,400 42,000 27,000 [34,000/35,500] 33,000 [40,500/42,500] 38,000 [45,500/47,500] 45,000 [52,500/54,500] 14,800 [21,800/23,300] 20,000 [27,500/29,500] 21,000 [28,500/30,500] 23,800 [31,300/33,200] 2.51 3.23 3.60 4.10 2.46 [4.49/4.94] 3.00 [5.25/5.76] 3.32 [5.57/6.08] 3.76 [6.03/6.52] 1.95 [3.98/4.43][...]
-
Page 10
10 PC24GK PC30GK PC36GK PC42GK 25,000 31,000 36,500 42,500 2.61 3.18 3.62 4.10 10.4 10.0 10.3 10.8 PC24GK PC30GK PC36GK PC42GK Munsell 0.7Y 8.59 / 0.97 115, 1, 60 15 2.0 3.0 1.9 2.4 710-880 990-1,240 640-810 880-1,130 51-9/16 63-3/4 26-3/4 10-5/8 82 95 99 PU24EK PU30EK PU36EK PU42EK7 Munsell 5Y 7/1 208/230, 1, 60 20 30 40 16 20 22 28 0.65+0.65 0.75[...]
-
Page 11
11 5. Specifications Cooling *1 BTU/h Capacity Heating *1,*3 BTU/h Heating *2,*3 BTU/h Cooling *1 kW Heating *1,*3 kW Heating *2,*3 kW SEER HSPF INDOOR UNIT MODELS External finish P ower supply V , Phase, Hz Max. fuse size (time delay) A Min. ampacity A F an motor F . L. A. Auxiliary heater A (kW) Airflow Dry CFM Lo-Hi Wet CFM Wi n Dimensions D in [...]
-
Page 12
12 Printed in Japan BG79P948H04 HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MAR UNOUCHI, CHIY ODA-KU , TOKY O 100-8310, JAP AN 5. Specifications Cooling capacity *1 BTU/h P ower consumption *1 kW SEER INDOOR UNIT MODELS External finish P ower supply V , Phase, Hz Max. fuse size (time delay) A Min. ampacity A F an motor F . L. A. Airflow Dry CFM Lo-[...]