Mitsubishi Electronics C64T manuel d'utilisation

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317

Aller à la page of

Un bon manuel d’utilisation

Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Mitsubishi Electronics C64T. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Mitsubishi Electronics C64T ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.

Qu'est ce que le manuel d’utilisation?

Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Mitsubishi Electronics C64T décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.

Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.

Donc, ce qui devrait contenir le manuel parfait?

Tout d'abord, le manuel d’utilisation Mitsubishi Electronics C64T devrait contenir:
- informations sur les caractéristiques techniques du dispositif Mitsubishi Electronics C64T
- nom du fabricant et année de fabrication Mitsubishi Electronics C64T
- instructions d'utilisation, de réglage et d’entretien de l'équipement Mitsubishi Electronics C64T
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes

Pourquoi nous ne lisons pas les manuels d’utilisation?

Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Mitsubishi Electronics C64T ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Mitsubishi Electronics C64T et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Mitsubishi Electronics en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Mitsubishi Electronics C64T, comme c’est le cas pour la version papier.

Pourquoi lire le manuel d’utilisation?

Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Mitsubishi Electronics C64T, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.

Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Mitsubishi Electronics C64T. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.

Table des matières du manuel d’utilisation

  • Page 1

    CNC C6/C64/C64T PARAMETER MANUAL BNP-B2267C(ENG)[...]

  • Page 2

    MELDAS and MELSEC are registered trademarks of Mitsubishi Electric Corporation. Microsoft and Windows are a registered trademark of Mi crosoft Corporation in the United States and/or other countries. Other brands and product names thr oughout this manual are trademarks or registered trademarks of their respective holders.[...]

  • Page 3

    Introduction This manual is a guide of the parameter s used with the CNC MELDAS C6/C64/C64T. This manual is written on the assumption t hat all machine parameters of the MELDAS C6/C64/C64T are provided. However, the CNC may not necessarily be provided with all of the options. When the system is used, t herefore, reference should be made to the Spec[...]

  • Page 4

    Precautions for Safety Always read the Specifications Manual issued by the machine maker, this manual, related manuals and attached documents before inst allation, operation, programming, maintenance or inspection to ens ur e c or r ect use. Understand this numerical controller, safety items and cautions before using the unit. This manual ranks the[...]

  • Page 5

    CAUTION 2. Items related to servo/spindle parameters To change the control mode to the High-gain amp (MDS-B-V14/V24) mode after replacement of the Standard amp (MDS-B-V1/V2), it is need to change the parameters and to adjust the servo parameters to fit to the High-gain amp. Mode change between the Standard amp mode and the High-gain amp mode is act[...]

  • Page 6

    CONTENTS 1. Parame ter Sc reens .......................................................................................................... ........................ 1 2. Machini ng Parame ters ....................................................................................................... ...................... 3 2.1 Workpiece C oordinate Off[...]

  • Page 7

    1. Parameter Screens 1 1. Parameter Screens The parameter input setting units are as follow. Linear axis " #1017 rot " =0 Input unit " #1003 iunit " Machine constant:mm " #1040 M_inch " =0 Machine constant:inch " #1040 M_inch " =1 Rotary axis " #1017 rot " =1 B 0.001 mm 0.0001 inch 0.001° C 0.0001 [...]

  • Page 8

    1. Parameter Screens 2 (2) Setup Parameters The following menus can be selected when SETUP is selected. (Refer to the section "4. Setup Parameters" for details. Menu Details Reference Section BASE The BASE SPEC. PARAM screen will open. 5. Base Specifications Parameters AXIS SPEC The AXIS SPEC PARAM screen will open. 6. Axis Specifications[...]

  • Page 9

    2. Machining Parameters 2.1 Workpiece Coordinate Offset 3 2. Machining Parameters 2.1 Workpiece Coordinate Offset # Parameter Explanation Setting range (unit) 54 G54 offset 55 G55 offset 56 G56 offset 57 G57 offset 58 G58 offset 59 G59 offset 60 EXT offset Set the workpiece coordinate system and external workpiece coordinate offset values from G54 [...]

  • Page 10

    2. Machining Parameters 2.2 Process Parameters 4 2.2 Process Parameters <WRK COUNT> (No. of workpieces machined) # Item Contents Setting range (unit) 8001 WRK COUNT M Set the M code that counts the No. of workpiece repeated machining. The No. will not be counted when set to 0. 0 to 99 8002 WRK COUNT The current machining No. is displayed. Set[...]

  • Page 11

    2. Machining Parameters 2.2 Process Parameters 5 <FIXED C.> (Fixed cycle) # Item Contents Setting range (unit) 8012 G73 n (For M system only) Set the return amount for G73 (step cycle). 0 to 99999.999 (mm) 8013 G83 n Set the return amount for G83 (deep hole drilling cycle). 0 to 99999.999 (mm) 8014 CDZ-VALE (For L system only) Set the screw c[...]

  • Page 12

    2. Machining Parameters 2.3 Control Parameters 6 2.3 Control Parameters # Item Contents Setting range (unit) 8101 MACRO SINGLE Select the contro l of the blocks where the user macro command continues. 0: Do not stop while macro block continues. 1: Stop every block duri ng signal block operation. 0/1 8102 COLL. ALM OFF Select the interference (bite)[...]

  • Page 13

    2. Machining Parameters 2.4 Axis Parameters 7 2.4 Axis Parameters # Item Contents Setting range (unit) 8201 AX. RELEASE Select the function to remove the control axis from the control target. 0: Control as normal 1: Remove from control target 0/1 8202 OT-CHECK OFF Select the stored stroke limit function set in #8204 and #8205. 0: Stored stroke limi[...]

  • Page 14

    2. Machining Parameters 2.5 Barrier Data 8 # Item Contents Setting range (unit) 8208 G76/87 (–) (For M system only) Specify the shift direction at G76 and G87. 0: Shift to (+) direction 1: Shift to (–) direction 0/1 8209 G60 SHIFT (For M system only) Set the last positioning direction and distance for a G60 (uni-directional positioning) command[...]

  • Page 15

    3. I/O Parameters 3.1 Base Parameters 9 3. I/O Parameters 3.1 Base Parameters <I/O> # <PORT No.> # < DEV. No.> <DEV. NAME> Specify the board No. to which the serial input/output device is connected to each application. Set the input/output device No. for each application. The device Nos. are 0 to 4 and correspond to the inpu[...]

  • Page 16

    3. I/O Parameters 3.2 I/O Device Parameters 10 3.2 I/O Device Parameters Parameters for up to five types of input/out put devices can be set in DEV <0> to <4>. (Note) The parameters are set for each device. 9101 ~ Set the same settings for device 0. 9201 ~ Set the same settings for device 1. 9301 ~ Set the same settings for device 2. 94[...]

  • Page 17

    3. I/O Parameters 3.2 I/O Device Parameters 11 # Item Contents Setting range (unit) 9107 9207 9307 9407 9507 TERMINATOR TYPE The code to terminate data reading can be selected. 0 and 3: EOR 1 and 2: EOB or EOR 9108 9208 9308 9408 9508 HAND SHAKE Specify the transmission control method. The method will be no procedure if a value except 1 to 3 is set[...]

  • Page 18

    3. I/O Parameters 3.2 I/O Device Parameters 12 # Item Contents Setting range (unit) 9116 9216 9316 9416 9516 TIME-OUT (s) Set the time out time to detect an interruption in communication. The time out is not checked when 0 is set, so the waiting time will be infinite. The screens cannot be changed during the waiting time. Set this time to 10 as the[...]

  • Page 19

    3. I/O Parameters 3.2 I/O Device Parameters 13 # Item Contents Setting range (unit) 9125 9225 9325 9425 9525 = 9126 9226 9326 9426 9526 : 9127 9227 9327 9427 9527 $ 9128 9228 9328 9428 9528 ! (Continued from the previous page.)[...]

  • Page 20

    4. Setup Parameters 14 4. Setup Parameters Pressing the menu key SE TU P displays the OPEN SETUP PARAM screen. The system’s basic parameters are normally hi dden as setup parameters to prevent mistaken operations and to simplify the display. The setup parameters can be displayed and se t by making a declaration to open the setup parameters on thi[...]

  • Page 21

    5. Base Specifications Parameters 15 5. Base Specifications Parameters After setting up the parameter (PR) listed in the table, turn off the NC power. To validate the parameter, turn on the power again. # Items Details Setting range (unit) 1001 (PR) SYS_ON Part system validation setup Specify the presence of the PLC axes and the 1st to 7th part sys[...]

  • Page 22

    5. Base Specifications Parameters 16 # Items Details Setting range (unit) 1017 (PR) rot Rotational axis Specify whether the axis is a rotary axis or linear axis. For the rotary axis‚ the position display will be 360 degrees‚ and the axis will return to 0 degrees. If the position display is to be continuously displayed even with the rotary axis?[...]

  • Page 23

    5. Base Specifications Parameters 17 # Items Details Setting range (unit) 1025 l_plane Initial plane selection Specify the plane to be selected when the power is turned on or reset. When 0 is specified, 1 is assumed (X-Y plane). 1 : X-Y plane (G17 command state) 2: Z-X plane (G18 command state) 3: Y-Z plane (G19 command state) 1026 1027 1028 base_l[...]

  • Page 24

    5. Base Specifications Parameters 18 # Items Details Setting range (unit) 1037 cmdtyp Command type Specify the program G code series and compensation type. cmdtyp G code series Compensation type 1 System 1 (for M) Type A (one compensation amount for one compen- sation number) 2 System 2 (for M) Type B (shape and wear amounts for one compen- sation [...]

  • Page 25

    5. Base Specifications Parameters 19 # Items Details Setting range (unit) 1039 spinno Number of spindles Specify the existence of a spindle. 0: No spindle 4: Four spindles 1: One spindle 5: Five spindles 2: Two spindles 6: Six spindles 3: Three spindles 7: Seven spindles 0 to 7 1040 (PR) M_inch Constant input (inch) Specify the parameter unit syste[...]

  • Page 26

    5. Base Specifications Parameters 20 # Items Details Setting range (unit) 1060 SETUP Activate setup processing Execute the functions required for initializing the system. INPUT INPUT Y INPUT N INPUT Y INPUT N (Note) Most setup parameters will be initialized with one-touch setup‚ so confirm the data before executing. This parameter will automatica[...]

  • Page 27

    5. Base Specifications Parameters 21 # Items Details Setting range (unit) 1062 T_cmp Tool offset function Specify whether the tool length offset and wear compensation is valid during T command execution. 0 to 3 1063 mandog Manual dog-type The initial return to the reference point is performed with dog-type return after the power is turned on‚ and[...]

  • Page 28

    5. Base Specifications Parameters 22 # Items Details Setting range (unit) 1066 JOG_HP Select JOG activation (+) device Specify the number of t he device that inputs +JOG activation signals. The device type is specified by "#1071 JOG_D". The effective range of set values vary depending on the device type. A value outside of the effective r[...]

  • Page 29

    5. Base Specifications Parameters 23 # Items Details Setting range (unit) 1073 I_Absm Initial absolute value Specify the absolute value/incremental value mode for when the power is turned on or reset. 0: Incremental value command mode 1: Absolute value command mode 1074 l_Sync In iti al synchronous feed Specify the feedrate specif ication mode for [...]

  • Page 30

    5. Base Specifications Parameters 24 # Items Details Setting range (unit) 1080 Dril_Z (For M system only) Specify boring axis Specify a fixed-cycle boring axis. 0: Uses an axis perpendicular to the selected plane as the boring axis. 1: Uses the Z axis as the boring axis regardless of the selected plane. 0/1 1081 Gmac_P Give priority to G code param[...]

  • Page 31

    5. Base Specifications Parameters 25 # Items Details Setting range (unit) 1088 G30SL Disable G30 soft limit Specify how to handle the soft limit during G30 (2nd reference point return) movement. 0: Soft limit valid during G30 movement 1: Soft limit invalid during G30 movement 0/1 1089 Cut_RT Short cut for rotary axis Specify how to handle the short[...]

  • Page 32

    5. Base Specifications Parameters 26 # Items Details Setting range (unit) 1095 T0tfof TF output Select how to handle TF for T00 command. 0: TF is output. 1: TF is not output 0/1 1096 T_Ltyp (For L system only) Tool life management type Specify the tool life management type. 1: Life manage- ment type l 2: Life manage- ment type ll 1097 T1digt Tool w[...]

  • Page 33

    5. Base Specifications Parameters 27 # Items Details Setting range (unit) 1100 Tmove Tool wear compen- sation Specify the period to perform tool length offset and wear compensation. 0: Compensate when T command is executed. 1: Superimpose and compensate with the movement command in the block where the T command is located. If there is no movement c[...]

  • Page 34

    5. Base Specifications Parameters 28 # Items Details Setting range (unit) 1105 T_Sel2 Tool selection method 2 Select the tool selection method for when "#1103 T_Life" is set to 1. 0: Select in order of registered No. from the tools used in the same group. 1: Select the tool with the longest remaining life from tools used in the same group[...]

  • Page 35

    5. Base Specifications Parameters 29 # Items Details Setting range (unit) 1114 mcrint Macro argument initialization Select whether to clear statements other than specified arguments by macro call. Also, select whether to clear local variables by power-on and resetting. 0: Delete non-specified arguments by macro call. 1: Retain non-specified argumen[...]

  • Page 36

    5. Base Specifications Parameters 30 # Items Details Setting r ange (unit) 1121 edlk_c Edit lock C Specify whether to prohibit editing of program Nos. 9000 to 9999. 0: Editing possible 1: Editing prohibited 1122 (PR) pglk_c Program display lock The display and search of program Nos. 9000 to 9999 can be prohibited. Specify whether to prohibit displa[...]

  • Page 37

    5. Base Specifications Parameters 31 # Items Details Setting range (unit) 1128 RstVCI Clear variables by resetting Specify how to handle the common variables when resetting. 0: Common variables do not change after resetting. 1: The following common variables are cleared by resetting: During variable 100 sets specifications: #100 to #149 are cleared[...]

  • Page 38

    5. Base Specifications Parameters 32 # Items Details Setting range (unit) 1133 ofsmem Select how to set up tool wear compensa- tion screen Select the number stored by previous setup when selecting the tool wear compensation screen. 0: Does not display the number when selecting the screen. 1: Displays the stored number when selecting the screen. 0/1[...]

  • Page 39

    5. Base Specifications Parameters 33 # Items Details Setting range (unit) 1145 I_abs Manual ABS parameter Specify how to handle the absolute position data during automatic handle interrupt. 0: Absolute position data is renewed if manual ABS switch is on. Data is not renewed if switch is off. 1: Follows the intabs state when "#1061 intabs"[...]

  • Page 40

    5. Base Specifications Parameters 34 # Items Details Setting range (unit) 1152 I_G20 Initial command unit Specify whether the default mode after power-on or resetting, inch command or metric command mode. 0: Metric command (G21 command state) 1: Inch command (G20 command state) Valid when reset input is made. Related parameter: Bit 6 "Select s[...]

  • Page 41

    5. Base Specifications Parameters 35 # Items Details Setting r ange (unit) 1155 DOOR_m Signal input device 1 for door interlock II Set up a fixed device number (X??) for door interlock II signal input. A device number from X001 to X3FF can be set up. Device number 000 is invalid. Set up device number 100 when using no fixed device number for door i[...]

  • Page 42

    5. Base Specifications Parameters 36 # Items Details Setting range (unit) 1169 system name Part system name Set the name of each part system. This must be set when using the multiple part system. This name is displayed on the screen only when the part systems must be identified. Use a max. of four alphabetic characters or numerals. A max. of four a[...]

  • Page 43

    5. Base Specifications Parameters 37 # Items Details Setting range (unit) 1175 1176 1177 1178 1179 1180 skip1 1f 2 2f 3 3f G31.1 skip condition G31.1 skip speed G31.2 skip condition G31.2 skip speed G31.3 skip condition G31.3 skip speed Specify the skip signal in the G31.1 to G31.3 (multi-step skip) command‚ and the feedrate when there is no F co[...]

  • Page 44

    5. Base Specifications Parameters 38 # Items Details Setting range (unit) 1181 G96_ax Constant surface speed control Specify the axis to be tar geted for constant surface speed control. 0: Program specification will be invalidated‚ and the axis will always be fixed to the 1st axis. 1: 1st axis specification 2: 2nd axis specification 3: 3rd axis s[...]

  • Page 45

    5. Base Specifications Parameters 39 # Items Details Setting range (unit) 1193 inpos Validate in-position check Specify the deceleration confirmation method for the positioning command. 0: Command deceleration check (Positioning is completed when the deceleration is completed with the acceleration/deceleration speed issued from the control unit.) 1[...]

  • Page 46

    5. Base Specifications Parameters 40 # Items Details Setting range (unit) 1203 TmirS1 (For L system only) Select turrets for double-turret mirror image with T command Set up turrets for double-turret mirror image with the T command that corresponds to tool numbers 1 to 32. 0 to FFFFFFFF 1204 TmirS2 (For L system only) Select turrets for double-turr[...]

  • Page 47

    5. Base Specifications Parameters 41 # Items Details Setting range (unit) 1210 RstGmd Modal G code reset Specify whether to initialize each G code group modal and the H and D codes when the system is reset. Specify the initialization items in bit correspondence. 0. Initialize. 1: Do not initialize. M system Specify a hexadecimal number. The H code [...]

  • Page 48

    5. Base Specifications Parameters 42 # Items Details Setting range (unit) 1210 RstGmd Modal G code reset L system Specify a hexadecimal number. 1211 FHtyp Feed hold stop type Specify the type of the ex ternal signal used for feed hold. 0: Disable the external signal. 1: Enable the external signal (contact A) 2: Enable the external signal (contact B[...]

  • Page 49

    5. Base Specifications Parameters 43 # Items Details Setting range (unit) 1218 aux02 (bit3) Parameter input/output format Specify a parameter input/output format. 0: Type I 1: Type II 0/1 aux02 (bit4) Tool number selection Specify the R register that contains the tool number used for automatic calculation when measuring the coordinate offset of an [...]

  • Page 50

    5. Base Specifications Parameters 44 # Items Details Setting range (unit) aux03 (bit7) Time constant setting changeover for software acceleration/ deceleration 0: Accelerating time is G0tL(G1tL). If the time is set to the software acceleration/deceleration 2nd step time constant (#2005 G0t1) under such condition as the acceleration/deceleration bef[...]

  • Page 51

    5. Base Specifications Parameters 45 # Items Details Setting range (unit) (Continued from the previous page) 1: Accelerating time is obtained by G0tL+G0t1 (G1tL+G1t1). When the acceleration/deceleration before G00 interpolation and the software acceleration/deceleration are used one together, if the same time is set to S-curve filter time (#1131 F1[...]

  • Page 52

    5. Base Specifications Parameters 46 # Items Details Setting range (unit) 1220 aux04 (bit1) Validity of space code in comment Validate or invalidate the space code described in the comment statements in the machining program in edit operation with the custom display. 0: Invalidate the space code in the comment statements of the machining program. 1[...]

  • Page 53

    5. Base Specifications Parameters 47 # Items Details Setting range (unit) 1226 aux10 (bit0) Tool compen- sation data for external workpiece coordinate offset measurement Select the tool offset data to be used for external workpiece coordinate offset measurement. 0: Tool length data and nose wear data 1: Tool length data 0/1 aux10 (bit1) Optional bl[...]

  • Page 54

    5. Base Specifications Parameters 48 # Items Details Setting range (unit) 1226 aux10 (bit6) Setup and display unit Specify the unit to be used as the setup/display unit or handle feed unit, the command unit or internal unit. 0: Internal unit 1: Unit specified by command (Note 1) This parameter is valid only in initial millimeter mode (0 is set in &[...]

  • Page 55

    5. Base Specifications Parameters 49 # Items Details Setting range (unit) 1227 aux11 (bit2) Measures against tool setter chattering Select a condition where a relieving operation completes after measurement with tools. 0: Sensor signals have stopped for 500 ms or longer. 1: 100 µ s or longer has passed after sensor signals stopped. 0/1 aux11 (bit3[...]

  • Page 56

    5. Base Specifications Parameters 50 # Items Details Setting range (unit) 1228 aux12 (bit0) Switc h coordinate value screen Set up this option to switch the coordinate value screen. 0: 80-character screen 1: 40-character screen 0/1 aux12 (bit1) Switc h offset and parameter screen Set up this option to switch the offset and parameter screen to the p[...]

  • Page 57

    5. Base Specifications Parameters 51 # Items Details Setting range (unit) 1229 set01 (bit2) Radius compen- sation type B (For M system only) 0: When the start-up and cancel commands are operated during radius compensation, their blocks are not handled by intersection operation processing; they are handled as offset vectors in the direction vertical[...]

  • Page 58

    5. Base Specifications Parameters 52 # Items Details Setting range (unit) 1234 set06 Not used. 1235 set07 Not used. 1236 set08 (bit0) Manual rotation axis feedrate unit Select the unit of manual rotation axis feedrate. 0: Fixed to [°/min] 1: Same speed as before 0/1 1237 (PR) set09 (bit0) External workpiece offset Set up this function to use the e[...]

  • Page 59

    5. Base Specifications Parameters 53 # Items Details Setting r ange (unit) 1265 (PR) ext01 (bit0) Command format Select the command format. 0: Conventional format 0 1266 (PR) ext02 Not used. 1267 (PR) ext03 (bit0) G code type Select the G code type. This parameter is valid when 1 is set in "#1265 ext01 bit 0 (command format)". 0/1 1268 (P[...]

  • Page 60

    5. Base Specifications Parameters 54 # Items Details Setting r ange (unit) ext07 (bit3) G-code group for unidirectiona l positioning (for M system only) Specify the G-code group for uni directional positioning. Not applied to this CNC. 0: Unmodal G code (group 00) 1: Modal G code (group 01) Related parameter: ”#8209 G60 SHIFT”(Set the last posi[...]

  • Page 61

    5. Base Specifications Parameters 55 # Items Details Setting range (unit) 1271 (PR) ext07 (bit7) Cut amount (For L system only) Specify the operation to be performed when the program-specified cut amount exceeds the cut amount of the final shaping program. 0: Conventional specifications A program error occurs if the program-specified cut amount exc[...]

  • Page 62

    5. Base Specifications Parameters 56 # Items Details Setting range (unit) 1286 (PR) ext22 Not used. 1287 (PR) ext23 (bit0) Workpiece coordinate display Select the mode of displaying the workpiece coordinate counter. 0: Does not update the display immediately after workpiece coordinate data is changed. 1: Updates the display immediately after workpi[...]

  • Page 63

    5. Base Specifications Parameters 57 # Items Details Setting range (unit) ext23 (bit7) Absolute coordinate display (M system) 0: Displays the actual position including tool radius compensation. 1: Displays the machining position in terms of a program command excluding tool radius compen- sation. (L system) 0: Displays the actual position including [...]

  • Page 64

    5. Base Specifications Parameters 58 # Items Details Setting range (unit) 1301 nrfchk Origin neighboring check method Select the high-speed check method of the origin neighboring signal. 0: Does not check positions near the origin at high speeds. (Conventional specifications) 1: Checks positions near the origin at high speeds using command machine [...]

  • Page 65

    5. Base Specifications Parameters 59 # Items Details S etting range (unit) 1801 Hacc_c Arc radius clam acceleration -99999999 to +99999999 1802 Macc_c Acceleration check at middle speed -99999999 to +99999999 1803 Lacc_c Acceleration check at low speed -99999999 to +99999999 1811 Hcof_A X-axis high acceleration coefficient β -99999999 to +99999999[...]

  • Page 66

    5. Base Specifications Parameters 60 # Items Details Setting range (unit) 1901 (PR) station addr Set up a station addr ess number (the NC is the n-th slave station). 1 to 7 1902 (PR) Din size Set up the size of the data to be transferred from the PC to the NC (from the mast er station to the slave station) in bytes (8 points). 0 to 32 (bytes (8 bit[...]

  • Page 67

    5. Base Specifications Parameters 61 # Items Details Setting range (unit) 1929 (PR) Port number Set the HMI connection port No. (Set the default value 64758 unless particularly required.) 0 to 65535 1930 (PR) Speed 10M/auto Set the communication rate. 0: Fixed to “10Mbyte” 1: Recognized whether “10Mbyte” or “100Mbyte” automatically and [...]

  • Page 68

    5. Base Specifications Parameters 62 # Items Details Setting range (unit) 21025 S m p D el a y S et u p a s a mp l i n g t im e a f t er a n a l a r m o c c u r s . 0 t o 3000 (ms) 21028 ed_mess Set up an edit type. 0: Displays messages with state. 1: Displays operation message equivalent to M50. 0/1 21029 N C n a m e U s e t h i s to d i s p l a y[...]

  • Page 69

    5. Base Specifications Parameters 63 # Items Details Setting range (unit) 21101 add01 (bit0) PLC axis rapid traverse mode acceleration/ deceleration type Select the PLC axis rapid traverse mode acceleration/ deceleration type. (This is compatible from software version C0 and higher.) 0: Select constant time constant acceleration/ deceleration 1: Se[...]

  • Page 70

    5. Base Specifications Parameters 64 # Items Details Setting range (unit) 21102 add02 (bit0) Servo parameter 100-point compliance 0: The number of servo parameters is set to 64 points. 1: The number of servo parameters is set to 100 points when using the 100- point servo parameter compliant amplifier. (This is compatible from software version C1 an[...]

  • Page 71

    5. Base Specifications Parameters 65 # Items Details Setting range (unit) 21105 add05 Not used. 0 21106 add06 21107 add07 21108 add08 21109 add09 21110 add10 21111 add11 21112 add12 21113 add13 21114 add14 21115 add15 21116 add16 21117 add17 21118 add18 21119 add19 21120 add20 21121 add21 21122 add22 21123 add23 21124 add24[...]

  • Page 72

    6. Axis Specifications Parameters 6.1 Axis Specifications Parameters 66 6. Axis Specifications Parameters 6.1 Axis Specifications Parameters After setting up the parameter (PR) listed in the table, turn off the NC power. To validate the parameter, turn on the power again. # Items Details Se tting range (unit) 2001 rapid Rapid traverse feedrate Set [...]

  • Page 73

    6. Axis Specifications Parameters 6.1 Axis Specifications Parameters 67 # Items Details Setting range (unit) (Continued from the previous page) Cutting feed acceleration and deceleration types LC: Linear acceleration/deceleration C1: Primary delay C3: Exponential acceleration and linear deceleration (Note) Designate “F” with bits 4 to 7 for cut[...]

  • Page 74

    6. Axis Specifications Parameters 6.1 Axis Specifications Parameters 68 # Items Details Setting range (unit) (Continued from the previous page) G0 t 1 S t r ok e en d si gnal Spe ed G0 t 1 (0 T 1 =0 ) 2 G 0 t1 Ti me (0 T 1= 1 ) OT1 is valid under the following conditions (valid for dog type reference point return): Stop type: Linear deceleration Ac[...]

  • Page 75

    6. Axis Specifications Parameters 6.1 Axis Specifications Parameters 69 # Items Details Setting range (unit) 2005 G0t1 G0 time constant (primary delay) Second-step time constant for acceleration and deceleration by software Set up a primary-delay time c onstant for rapid traverse acceleration and deceleration. The time constant is validated when R1[...]

  • Page 76

    6. Axis Specifications Parameters 6.1 Axis Specifications Parameters 70 # Items Details Setting range (unit) 2007 G1tL G1 time constant (linear) Set up a linear control time constant for cutting acceleration and deceleration. The time constant is validated when LC (cutting feed with linear acceleration and deceleration) or F (acceleration and decel[...]

  • Page 77

    6. Axis Specifications Parameters 6.1 Axis Specifications Parameters 71 # Items Details Setting range (unit) 2010 fwd _ g Feed forward gain Set up a feed forward gain for pre-interpolation acceleration and deceleration. The larger the set value, the smaller the theoretical control error will be. However, if a mechanical vibration occurs, the set va[...]

  • Page 78

    6. Axis Specifications Parameters 6.1 Axis Specifications Parameters 72 # Items Details Setting range (unit) 2017 tap _ g Axis servo gain Set the position loop gain in the synchronous tap cycle. The setting range is 0.25 to 200.00rad/s‚ in 0.25 increment units. The standard setting is 10. 0.25 to 200.00 (rad/s) 2018 no _ srv Operation with no ser[...]

  • Page 79

    6. Axis Specifications Parameters 6.2 Zero Point Return Parameters 73 6.2 Zero Point Return Parameters After setting up the parameter (PR) listed in the table, turn off the NC power. To validate the parameter, turn on the power again. # Items Details Setting range (unit) 2025 G28rap G28 rapid traverse feedrate Set up a rapid traverse feedrate for d[...]

  • Page 80

    6. Axis Specifications Parameters 6.2 Zero Point Return Parameters 74 # Items Details Setting range (unit) 2030 (PR) dir ( − ) Reference point direction ( − ) Set which side of the near-point dog the reference point is at during reference point return. <For dog type reference point return> Direction in which zero point is established as v[...]

  • Page 81

    6. Axis Specifications Parameters 6.3 Absolute Position Parameters 75 6.3 Absolute Position Parameters # Items Details Setting range (unit) 2049 (PR) type Abso lute position detection method Specify the absolute position zero point alignment method. 0: Not absolute position detection 1: Stopper method (push onto mechanical stopper) 2: Marked point [...]

  • Page 82

    6. Axis Specifications Parameters 6.3 Absolute Position Parameters 76 # Items Details Setting range (unit) 2054 clpush Current limit (%) Set up the current limit value for the initial setting when detecting an absolute position with a dog-less system. The setup value is the ratio of the current limit value to the rated value. 0 to 100 (%) 2055 push[...]

  • Page 83

    6. Axis Specifications Parameters 6.4 Axis Specifications Parameters 2 77 6.4 Axis Specifications Parameters 2 # Items Details Setting range (unit) 2061 OT _ 1B − Soft limit IB − Set up the coordinates of the lower limit of the inhibited area of stored stroke limit IB. Specify a value in the basic machine coordinates system. If the same value ([...]

  • Page 84

    6. Axis Specifications Parameters 6.4 Axis Specifications Parameters 2 78 # Items Details Setting range (unit) 2073 zrn_dog Origin dog Random assignment device When it is desired to assign the origin dog signal to a position other than the fixed device, specify the input device in this parameter. (Note1) This parameter is valid when 1 is set in #12[...]

  • Page 85

    6. Axis Specifications Parameters 6.4 Axis Specifications Parameters 2 79 # Items Details Setting range (unit) 22011 bscmp − Offset compensa- tion position Specify the coordinates on the machine basic coordinates where the compensation is carried out by the offset amount. ± 99999.999 22012 bscmp + Max. compensa- tion position Specify the coordin[...]

  • Page 86

    7. Servo Parameters 80 7. Servo Parameters The parameters can be changed from any screen. The valid servo parameters will differ according to the motor type. The setting values and meanings may also differ. Follow the correspondence table gi ven below, and set the correct parameters. Refer to each Instruction Manual or the following manuals for det[...]

  • Page 87

    7. Servo Parameters 81 Corresponding model Parameter MDS-B-SVJ2 MDS-C1-Vx (High-gain) (MDS-B-Vx4) MDS-C1-Vx (Standard) (MDS-B-Vx) SV033 Servo function selection 2 SV034 Servo function selection 3 SV035 Servo function selection 4 SV036 Regenerative resistor type SV037 Load inertia scale SV038 Notch filter frequency 1 – SV039 Lost motion compensati[...]

  • Page 88

    7. Servo Parameters 7.1 MDS-B-SVJ2 82 7.1 MDS-B-SVJ2 (1) Details for servo parameters For parameters marked with a (PR) in the table, turn the NC power OFF after setting. After the power is turned ON again, the parameter is validated. ! CAUTION ! In the explanation on bits, set all bits not used, including blank bits, to “0”. No. Items Details [...]

  • Page 89

    7. Servo Parameters 7.1 MDS-B-SVJ2 83 No. Items Details Setting range 2213 SV013 ILMT Current limit value Set the normal current (torque) limit value. (Limit values for both + and - direction.) When the value is “500” (a standard setting), the maximum torque is determined by the specification of the motor. 0 to 500 (Stall [rated] current %) 221[...]

  • Page 90

    7. Servo Parameters 7.1 MDS-B-SVJ2 84 No. Items Details Setting range 2217 (PR) SV017 SPEC Servo specification selection F E D C B A 9 8 7 6 5 4 3 2 1 0 abs vdir mc dmk bit Meaning when “0” is set Meaning w hen “1” is set 0 dmk Deceleration control stop (SVJ2 standard) Dynamic brake stop 1 2 3 mc Contactor control output inva lid Contactor [...]

  • Page 91

    7. Servo Parameters 7.1 MDS-B-SVJ2 85 No. Items Details Setting range 2221 SV021 OLT Overload detection time constant Set the detection time constant of Overload 1 (Alarm 50). Set to “60” as a standard. (For machine tool builder adjustment.) 1 to 300 (s) 2222 SV022 OLL Overload detection level Set the current detection level of Overload 1 (Alar[...]

  • Page 92

    7. Servo Parameters 7.1 MDS-B-SVJ2 86 No. Items Details Setting range 2225 (PR) SV025 MTYP Motor/ Detector type F E D C B A 9 8 pen ent 7 6 5 4 3 2 1 0 mtyp bit Explanation 0 Set the motor type. 1 Set- ting 0x 1x 2x 3x 4x 5x 6x 7x 8x 2 x0 HA40N HA-FF43 HA43N 3 x1 HA80N HA-FF63 HA83N 4 x2 HA100N HA103N 5 x3 HA200N 6 x4 7 mtyp x5 x6 x7 x8 x9 xA HA93N[...]

  • Page 93

    7. Servo Parameters 7.1 MDS-B-SVJ2 87 No. Items Details Setting range (Continued from the previous page) bit Explanation 8 9 A B ent Set the speed detector type. Set to “2”. C D E F pen Set the position detector type. Set to “2”. 2226 SV026 OD2 Excessive error detection width during servo OFF Set the excessive error detection width when ser[...]

  • Page 94

    7. Servo Parameters 7.1 MDS-B-SVJ2 88 No. Items Details Setting range 2228 SV028 Not used. Set to “0”. 0 2229 SV029 Not used. Set to “0”. 0 2230 SV030 IVC Voltage dead time compensa- tion When 100% is set, the voltage equivalent to the logical non-energized time will be compensated. Adjust in increments of 10% from the default value 100%. I[...]

  • Page 95

    7. Servo Parameters 7.1 MDS-B-SVJ2 89 No. Items Details Setting range 2233 SV033 SSF2 Servo function selection 2 F E D C B A 9 8 a f s 7 6 5 4 3 2 1 0 fhz2 nfd bit Meaning when “0” is set Meaning when “1” is set 0 Set the filter depth for Notch filter (SV038: FHz1). 1 The control is stabilized by making the filter shallower. 2 Value 0 2 4 6[...]

  • Page 96

    7. Servo Parameters 7.1 MDS-B-SVJ2 90 No. Items Details Setting range 2234 SV034 SSF3 Servo function selection 3 F E D C B A 9 8 7 6 5 4 3 2 1 0 daf2 daf1 dac2 dac1 mon bit Meaning w hen “0” is set Meaning when “1” is set 0 NC servo monitor MAX current display data changeover 1 Set- ting MAX current 1 MAX current 2 2 0 Max. current command [...]

  • Page 97

    7. Servo Parameters 7.1 MDS-B-SVJ2 91 No. Items Details Setting range 2235 SV035 SSF4 Servo function selection 4 F E D C B A 9 8 cl2n clG1 7 6 5 4 3 2 1 0 bit Meaning w hen “0” is set Meaning w hen “1” is set 0 1 2 3 4 5 6 7 8 9 A B C D E clG1 Collision detection method 1 Set the collision detection level during cutting feed (G1). The G1 co[...]

  • Page 98

    7. Servo Parameters 7.1 MDS-B-SVJ2 92 No. Items Details Setting range 2236 (PR) SV036 PTYP Regenera- tive resistor type F E D C B A 9 8 amp rtyp 7 6 5 4 3 2 1 0 emgx bit Explanation 0 1 2 3 Always set to “0(0000)”. 4 Set the external emergency stop function. (Setting is prohibite d for values with no description.) 5 Set- ting Explanation 6 0 Ex[...]

  • Page 99

    7. Servo Parameters 7.1 MDS-B-SVJ2 93 No. Items Details Setting range Set “the motor inertia + motor axis conversion load inertia” in respect to the motor inertia. Jl+Jm SV037 (JL) = Jm *100 Jm: Motor inertia 2237 SV037 JL Load inertia scale Jl: Motor axis conversion load inertia 0 to 5000 (%) 2238 SV038 FHz1 Notch filter frequency 1 Set the vi[...]

  • Page 100

    7. Servo Parameters 7.1 MDS-B-SVJ2 94 No. Items Details Setting range 2249 SV049 PGN1sp Position loop gain 1 in spindle synchronous control Set the position loop gain during the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). Set the same value as the value of the spindle parameter, position loop gain in [...]

  • Page 101

    7. Servo Parameters 7.1 MDS-B-SVJ2 95 No. Items Details Setting range 2261 SV061 DA1NO D/A output channel 1 data No. 2262 SV062 DA2NO D/A output channel 2 data No. Input the data number you wish to output to D/A output channel. 0 to 102 2263 SV063 DA1MPY D/A output channel 1 output scale 2264 SV064 DA2MPY D/A output channel 2 output scale When “0[...]

  • Page 102

    7. Servo Parameters 7.1 MDS-B-SVJ2 96 (2) Initial setting value (a) HC**/HC**R series Motor HC 52 HC 102* HC 102 HC 152* HC 152 HC 202* HC 202 HC 352* Drive unit capacity 06 07 10 10 20 10 20 20 SV001 PC1 - - - - - - - - SV002 PC2 - - - - - - - - SV003 PGN1 33 33 33 33 33 33 33 33 SV004 PGN2 0 0 0 0 0 0 0 0 SV005 VGN1 50 80 50 80 50 115 80 130 SV00[...]

  • Page 103

    7. Servo Parameters 7.1 MDS-B-SVJ2 97 Motor HC 52 HC 102* HC 102 HC 152* HC 152 HC 202* HC 202 HC 352* Drive unit capacity 06 07 10 10 20 10 20 20 SV033 SSF2 0 0 0 0 0 0 0 0 SV034 SSF3 0 0 0 0 0 0 0 0 SV035 SSF4 0 0 0 0 0 0 0 0 SV036 PTYP - - - - - - - - SV037 JL 0 0 0 0 0 0 0 0 SV038 FHz1 0 0 0 0 0 0 0 0 SV039 LMCD 0 0 0 0 0 0 0 0 SV040 LMCT 0 0 0[...]

  • Page 104

    7. Servo Parameters 7.1 MDS-B-SVJ2 98 Motor HC 53 HC 103 HC 153 HC 203* HC 103R HC 153R HC 203R Drive unit capacity 06 10 20 20 10 10 20 SV001 PC1 - - - - - - - SV002 PC2 - - - - - - - SV003 PGN1 33 33 33 33 33 33 33 SV004 PGN2 0 0 0 0 0 0 0 SV005 VGN1 80 80 80 100 10 10 10 SV006 0 0 0 0 0 0 0 SV007 0 0 0 0 0 0 0 SV008 VIA 1364 1364 1364 1364 1364 [...]

  • Page 105

    7. Servo Parameters 7.1 MDS-B-SVJ2 99 Motor HC 53 HC 103 HC 153 HC 203* HC 103R HC 153R HC 203R Drive unit capacity 06 10 20 20 10 10 20 SV033 SSF2 0 0 0 0 0 0 0 SV034 SSF3 0 0 0 0 0 0 0 SV035 SSF4 0 0 0 0 0 0 0 SV036 PTYP - - - - - - - SV037 JL 0 0 0 0 0 0 0 SV038 FHz1 0 0 0 0 0 0 0 SV039 LMCD 0 0 0 0 0 0 0 SV040 LMCT 0 0 0 0 0 0 0 SV041 LMC2 0 0 [...]

  • Page 106

    7. Servo Parameters 7.1 MDS-B-SVJ2 100 (b) HA**N series Motor HA 40N HA 80N HA 100N HA 200N* HA 053N HA 13N HA 23N HA 33N HA 43N HA 83N HA 103N* Drive unit capacity 06 10 20 20 01 01 03 03 06 10 20 SV001 PC1 - - - - - - - - - - - SV002 PC2 - - - - - - - - - - - SV003 PGN1 33 33 33 33 33 33 33 33 33 33 33 SV004 PGN2 0 0 0 0 0 0 0 0 0 0 0 SV005 VGN1 [...]

  • Page 107

    7. Servo Parameters 7.1 MDS-B-SVJ2 101 Motor HA 40N HA 80N HA 100N HA 200N* HA 053N HA 13N HA 23N HA 33N HA 43N HA 83N HA 103N* Drive unit capacity 06 10 20 20 01 01 03 03 06 10 20 SV033 SSF2 0 0 0 0 0 0 0 0 0 0 0 SV034 SSF3 0 0 0 0 0 0 0 0 0 0 0 SV035 SSF4 0 0 0 0 0 0 0 0 0 0 0 SV036 PTYP - - - - - - - - - - - SV037 JL 0 0 0 0 0 0 0 0 0 0 0 SV038 [...]

  • Page 108

    7. Servo Parameters 7.1 MDS-B-SVJ2 102 (c) HC-SF series Motor HC-SF 52 HC-SF 102 HC-SF 152 HC-SF 202 HC-SF 352 HC-SF 53 HC-SF 103 HC-SF 153 HC-SF 203 HC-SF 353 Drive unit capacity 06 07 10 10 20 06 07 10 10 20 SV001 PC1 - - - - - - - - - - SV002 PC2 - - - - - - - - - - SV003 PGN1 33 33 33 33 33 33 33 33 33 33 SV004 PGN2 0 0 0 0 0 0 0 0 0 0 SV005 VG[...]

  • Page 109

    7. Servo Parameters 7.1 MDS-B-SVJ2 103 Motor HC-SF 52 HC-SF 102 HC-SF 152 HC-SF 202 HC-SF 352 HC-SF 53 HC-SF 103 HC-SF 153 HC-SF 203 HC-SF 353 Drive unit capacity 06 07 10 10 20 06 07 10 10 20 SV033 SSF2 0 0 0 0 0 0 0 0 0 0 SV034 SSF3 0 0 0 0 0 0 0 0 0 0 SV035 SSF4 0 0 0 0 0 0 0 0 0 0 SV036 PTYP - - - - - - - - - - SV037 JL 0 0 0 0 0 0 0 0 0 0 SV03[...]

  • Page 110

    7. Servo Parameters 7.1 MDS-B-SVJ2 104 (d) HC-RF/HA-FF series Motor HC-RF 103 HC-RF 153 HC-RF 203 HA-FF 053 HA-FF 13 HA-FF 23 HA-FF 33 HA-FF 43 HA-FF 63 Drive unit capacity 10 10 20 01 01 03 03 04 06 SV001 PC1 - ----- - -- SV002 PC2 - ----- - -- SV003 PGN1 33 33 33 33 33 33 33 33 33 SV004 PGN2 0 00000 0 00 SV005 VGN1 10 10 10 10 13 13 18 20 20 SV00[...]

  • Page 111

    7. Servo Parameters 7.1 MDS-B-SVJ2 105 Motor HC-RF 103 HC-RF 153 HC-RF 203 HA-FF 053 HA-FF 13 HA-FF 23 HA-FF 33 HA-FF 43 HA-FF 63 Drive unit capacity 10 10 20 01 01 03 03 04 06 SV033 SSF2 0 0 0 0 0 0 0 0 0 SV034 SSF3 0 0 0 0 0 0 0 0 0 SV035 SSF4 0 0 0 0 0 0 0 0 0 SV036 PTYP - - - - - - - - - SV037 JL 0 0 0 0 0 0 0 0 0 SV038 FHz1 0 0 0 0 0 0 0 0 0 S[...]

  • Page 112

    7. Servo Parameters 7.1 MDS-B-SVJ2 106 (e) HC-MF series Motor HC-MF 053 HC-MF 13 HC-MF 23 HC-MF 43 HC-MF 73 Drive unit capacity 01 01 03 04 07 SV001 PC1 - - - - - SV002 PC2 - - - - - SV003 PGN1 33 33 33 33 33 SV004 PGN2 0 0 0 0 0 SV005 VGN1 6 6 6 6 8 SV006 0 0 0 0 0 SV007 0 0 0 0 0 SV008 VIA 1364 1364 1364 1364 1364 SV009 IQA 4096 4096 4096 4096 40[...]

  • Page 113

    7. Servo Parameters 7.1 MDS-B-SVJ2 107 Motor HC-MF 053 HC-MF 13 HC-MF 23 HC-MF 43 HC-MF 73 Drive unit capacity 01 01 03 04 07 SV033 SSF2 0 0 0 0 0 SV034 SSF3 0 0 0 0 0 SV035 SSF4 0 0 0 0 0 SV036 PTYP - - - - - SV037 JL 0 0 0 0 0 SV038 FHz1 0 0 0 0 0 SV039 LMCD 0 0 0 0 0 SV040 LMCT 0 0 0 0 0 SV041 LMC2 0 0 0 0 0 SV042 OVS2 0 0 0 0 0 SV043 OBS1 0 0 0[...]

  • Page 114

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 108 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) (1) Details for servo parameters For parameters marked with a (PR) in the table, turn the NC power OFF after setting. After the power is turned ON again, the parameter is validated. ! CAUTION ! In the explanation on bits, set all bi[...]

  • Page 115

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 109 No. Items Details Setting range Set this when the limit cycle occurs in the full-closed loop, or overshooting occurs in positioning. Select the control method with SV027 (SSF1)/bit1, 0 (vcnt). Normally, use “Changeover type 2”. When you set this parameter, make sure to set t[...]

  • Page 116

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 110 No. Items Details Setting range 2215 SV015 FFC Acceleration rate feed forward gain When a relative error in the synchronous control is large, apply this parameter to the axis that is delaying. The standard setting value is “0”. For the SHG control, set to “100”. To adjus[...]

  • Page 117

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 111 No. Items Details Setting range 2217 (PR) SV017 SPEC Servo specification selection F E D C B A 9 8 spm drvall drvup mpt3 mp 7 6 5 4 3 2 1 0 abs vdir fdir vfb seqh dfbx fdir2 bit Meaning w hen “0” is set Meaning when “1” is set 0 fdir2 Speed feedback forward polarity Spee[...]

  • Page 118

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 112 No. Items Details Setting range 2218 (PR) SV018 PIT Ball screw pitch Set the ball screw pitch. Set to “360” for the rotary axis. 1 to 32767 (mm/rev) 2219 (PR) SV019 RNG1 Position detector resolution In the case of the semi-closed loop control Set the same value as SV020 (RNG[...]

  • Page 119

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 113 No. Items Details Setting range 2221 SV021 OLT Overload detection time constant Set the detection time constant of Overload 1 (Alarm 50). Set to “60” as a standard. (For machine tool builder adjustment.) 1 to 999 (s) 2222 SV022 OLL Overload detection level Set the current de[...]

  • Page 120

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 114 No. Items Details Setting range 2225 (PR) SV025 MTYP Motor /Detector type F E D C B A 9 8 pen ent 7 6 5 4 3 2 1 0 mtyp bit Explanation 0 Set the motor type. 1 Set this along with SV017 (SPEC)/spm. 2 1) When SV017/spm=0 (Normal drive unit) 3 Set- ting 0x 1x 2x 3x 4x 5x 6x 7x 4 x0[...]

  • Page 121

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 115 No. Items Details Setting range (Continued from the previous page) bit Explanation 2) When SV017/spm=1 (S type drive unit) Set- ting 8x 9x Ax Bx Cx Dx Ex Fx x0 x1 x2 x3 x4 HC353 x5 HC452 HC453 x6 HC702 x7 x8 x9 xA xB xC xD xE xF 8 Set the detector type. 9 A Set the position dete[...]

  • Page 122

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 116 No. Items Details Setting range 2226 SV026 OD2 Excessive error detection width during servo OFF Set the excessive error detection width when servo ON. For the standard setting, refer to the explanation of SV023 (OD1). When “0” is set, the excessive error detection will not b[...]

  • Page 123

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 117 No. Items Details Setting range The higher order 8bits and lower order 8bi ts are used for different functions. “The setting value of SV030” = (Icx*256) + IVC 0 to 32767 SV030 IVC (Low order) Voltage dead time compensa- tion When 100% is set, the voltage equivalent to the lo[...]

  • Page 124

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 118 No. Items Details Setting range 2233 SV033 SSF2 Servo function selection 2 F E D C B A 9 8 dos hvx svx 7 6 5 4 3 2 1 0 nfd2 nf3 nfd1 zck bit Meaning w hen “0” is set Meaning w hen “1” is set 0 zck Z phase check valid (Alarm 42) Z phase check invalid 1 Set the filter dept[...]

  • Page 125

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 119 No. Items Details Setting range 2234 SV034 SSF3 Servo function selection 3 F E D C B A 9 8 ovsn 7 6 5 4 3 2 1 0 os2 zeg mohn has2 has1 bit Meaning when “0” is set Meaning when “1” is set 0 has1 Setting for normal use (Except for HC) HAS control 1 valid (HC: High accelera[...]

  • Page 126

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 120 No. Items Details Setting range 2235 SV035 SSF4 Servo function selection 4 F E D C B A 9 8 clt clG1 cl2n clet cltq 7 6 5 4 3 2 1 0 ckab iup tdt bit Meaning w hen “0” is set Meaning w hen “1” is set 0 1 2 3 4 5 tdt Td creation time setting Set to “0”. (For machine too[...]

  • Page 127

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 121 No. Items Details Setting range 2236 (PR) SV036 PTYP Power supply type F E D C B A 9 8 amp rtyp 7 6 5 4 3 2 1 0 ptyp bit Explanation 0 1 2 When the CN4 connector of the drive unit and the power supply are connected, setting below is necessary. To validate the external emergency [...]

  • Page 128

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 122 No. Items Details Setting range 2239 SV039 LMCD Lost motion compensation timing Set this when the lost motion compensation timing doest not match. Adjust by increasing the value by 10 at a time. 0 to 2000 (ms) The higher order 8bits and lower order 8bi ts are used for different [...]

  • Page 129

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 123 No. Items Details Setting range 2249 SV049 PGN1sp Position loop gain 1 in spindle synchronous control Set the position loop gain during the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). Set the same value as the value of the spindle [...]

  • Page 130

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 124 No. Items Details Setting range When SV035 (SSF4)/ bitF (ckab)=0 SV054 ORE Overrun detection width in closed loop control Set the overrun detection width in the full-closed loop control. If the gap between the motor end detector and the linear scale (machine end detector) exceed[...]

  • Page 131

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 125 No. Items Details Setting range 2258 SV058 SHGCsp SHG control gain in spindle synchronous control Set this with SV049 (PGN1sp) and SV050 (PGN2sp) if you wish to perform the SHG control in the spindle synchronous control (synchronous tapping, synchronous control with spindle/C ax[...]

  • Page 132

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 126 (2) Initial setting value (a) HC**/HC**R series Motor HC 52 HC 102 HC 152 HC 202 HC 352 HC 452 HC 702 HC 902 Drive unit capacity 05 10 20 20 35 45s 45 70s 70 90 SV001 PC1 - - ----- - -- SV002 PC2 - - ----- - -- SV003 PGN1 47 47 47 47 47 47 47 47 47 47 SV004 PGN2 0 0 00000 0 00 S[...]

  • Page 133

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 127 Motor HC 52 HC 102 HC 152 HC 202 HC 352 HC 452 HC 702 HC 902 Drive unit capacity 05 10 20 20 35 45s 45 70s 70 90 SV033 SSF2 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 SV034 SSF3 0003 0003 0003 0003 0003 0003 0003 0003 0003 0003 SV035 SSF4 0000 0000 0040 0040 0040 0040 004[...]

  • Page 134

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 128 Motor HC 53 HC 103 HC 153 HC 203 HC 353 HC 453 HC 703 Drive unit capacity 05 10 20 35 45s 45 70s 70 90 SV001 PC1 - - - - - - - - - SV002 PC2 - - - - - - - - - SV003 PGN1 47 47 47 47 47 47 47 47 47 SV004 PGN2 0 0 0 0 0 0 0 0 0 SV005 VGN1 200 200 200 200 200 200 200 200 200 SV006 [...]

  • Page 135

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 129 Motor HC 53 HC 103 HC 153 HC 203 HC 353 HC 453 HC 703 Drive unit capacity 05 10 20 35 45s 45 70s 70 90 SV033 SSF2 0000 0000 0000 0000 0000 0000 0000 0000 0000 SV034 SSF3 0003 0003 0003 0003 0003 0003 0003 0003 0003 SV035 SSF4 0000 0000 0040 0040 0040 0040 0040 0040 0000 SV036 PT[...]

  • Page 136

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 130 Motor HC 103R HC 153R HC 203R HC 353R Drive unit capacity 10 10 20 35 SV001 PC1 - - - - SV002 PC2 - - - - SV003 PGN1 33 33 33 33 SV004 PGN2 0 0 0 0 SV005 VGN1 15 15 20 40 SV006 VGN2 0 0 0 0 SV007 VIL 0 0 0 0 SV008 VIA 1364 1364 1364 1364 SV009 IQA 4096 4096 4096 4096 SV010 IDA 4[...]

  • Page 137

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 131 Motor HC 103R HC 153R HC 203R HC 353R Drive unit capacity 10 10 20 35 SV033 SSF2 0200 0200 0200 0200 SV034 SSF3 0000 0000 0000 0000 SV035 SSF4 0000 0000 0000 0000 SV036 PTYP 0000 0000 0000 0000 SV037 JL 0 0 0 0 SV038 FHz1 0 0 0 0 SV039 LMCD 0 0 0 0 SV040 LMCT 0 0 0 0 SV041 LMC2 [...]

  • Page 138

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 132 (b) HA**N series Motor HA 40N HA 80N HA 100N HA 200N HA 300N HA 700N HA 900N Drive unit capacity 05 10 20 35 45 70 90 SV001 PC1 - - ----- SV002 PC2 - - ----- SV003 PGN1 33 33 33 33 33 25 25 SV004 PGN2 0 0 00000 SV005 VGN1 150 150 150 150 150 250 250 SV006 VGN2 0 0 00000 SV007 VI[...]

  • Page 139

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 133 Motor HA 40N HA 80N HA 100N HA 200N HA 300N HA 700N HA 900N Drive unit capacity 05 10 20 35 45 70 90 SV033 SSF2 0000 0000 0000 0000 0000 0000 0000 SV034 SSF3 0000 0000 0000 0000 0000 0000 0000 SV035 SSF4 0000 0000 0000 0000 0000 0000 0000 SV036 PTYP 0000 0000 0000 0000 0000 0000[...]

  • Page 140

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 134 Motor HA 43N HA 83N HA 93N HA 103N HA 203N HA 303N HA 703N HA 053N HA 13N HA 23N HA 33N Drive unit capacity 05 10 20 35 45 70 90 01 01 03 03 SV001 PC1 - - - - - - - - - - - SV002 PC2 - - - - - - - - - - - SV003 PGN1 33 33 33 33 33 33 25 33 33 33 33 SV004 PGN2 0 0 0 0 0 0 0 0 0 0[...]

  • Page 141

    7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) 135 Motor HA 43N HA 83N HA 93N HA 103N HA 203N HA 303N HA 703N HA 053N HA 13N HA 23N HA 33N Drive unit capacity 05 10 20 35 45 70 90 01 01 03 03 SV033 SSF2 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 SV034 SSF3 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 SV035 [...]

  • Page 142

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 136 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) (1) Details for servo parameters For parameters marked with a (PR) in the table, turn the NC power OFF after setting. After the power is turned ON again, the parameter is validated. ! CAUTION ! In the expla[...]

  • Page 143

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 137 No. Items Details Setting range Set this when the limit cycle occurs in the full-closed loop, or overshooting occurs in positioning. Select the control method with SV027 (SSF1)/bit1, 0 (vcnt). Normally, use “Changeover type 2”. When you set this parameter, make [...]

  • Page 144

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 138 No. Items Details Setting range 2213 SV013 ILMT Current limit value Set the normal current (torque) limit value. (Limit values for both + and - direction.) When the value is “500” (a standard setting), the maximum torque is determined by the specification of the[...]

  • Page 145

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 139 No. Items Details Setting range 2217 (PR) SV017 SPEC Servo specification selection F E D C B A 9 8 m p t 3 m p 7 6 5 4 3 2 1 0 abs vdir fdir s p w v seqh dfbx fdir2 bit Meaning w hen “0” is set Meaning w hen “1” is set 0 fdir2 Speed feedback forward polarity[...]

  • Page 146

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 140 No. Items Details Setting range 2219 (PR) SV019 RNG1 Position detector resolution In the case of the semi-closed loop control Set the same value as SV020 (RNG2). (Refer to the explanation of SV020.) 1 to 9999 (kp/rev) In the case of the full-closed loop control Set [...]

  • Page 147

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 141 No. Items Details Setting range 2224 SV024 INP In-position detection width Set the in-position detection width. Set the accuracy required for the machine. The lower the setting is, the higher the positioning accuracy gets, however, the cycle time (setting time) beco[...]

  • Page 148

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 142 No. Items Details Setting range (Continued from the previous page) bit Explanation 8 9 A B ent Set the detector type. Set position detector type for “pen”, and speed detector type for “ent”. In the case of the semi-closed loop control, set the same value for[...]

  • Page 149

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 143 No. Items Details Setting range 2227 SV027 SSF1 Servo function selection 1 F E D C B A 9 8 aflt zrn2 afse ovs lmc 7 6 5 4 3 2 1 0 zrn3 vfct upc vcnt bit Meaning w hen “0” is set Meaning w hen “1” is set 0 vcnt Set the execution changeover type of the speed l[...]

  • Page 150

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 144 No. Items Details Setting range The higher order 8bits and lower order 8bi ts are used for different functions. “The setting value of SV030” = (Icx*256) + IVC 0 to 32767 SV030 IVC (Low order) Voltage dead time compensation When 100% is set, the voltage equivalen[...]

  • Page 151

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 145 No. Items Details Setting range 2232 SV032 TOF Torque offset Set the unbalance torque of vertical axis and inclined axis. -100 to 100 (Stall [rated] current %) 2233 SV033 SSF2 Servo function selection 2 F E D C B A 9 8 dos hvx svx 7 6 5 4 3 2 1 0 fhz2 nfd zck bit Me[...]

  • Page 152

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 146 No. Items Details Setting range 2234 SV034 SSF3 Servo function selection 3 F E D C B A 9 8 ovsn 7 6 5 4 3 2 1 0 o s 2 z e g has2 has1 bit Meaning w hen “0” is set Meaning w hen “1” is set 0 h as 1 Setting for normal use HAS control 1 valid (Except for HC) (H[...]

  • Page 153

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 147 No. Items Details Setting range 2235 SV035 SSF4 Servo function selection4 F E D C B A 9 8 clt clG1 cl2n clet cltq 7 6 5 4 3 2 1 0 iup tdt bit Meaning w hen “0” is set Meaning when “1” is set 0 Td creation time setting 1 Set to “0”. (For machine tool buil[...]

  • Page 154

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 148 No. Items Details Setting range 2236 (PR) SV036 PTYP Power supply type F E D C B A 9 8 amp rtyp 7 6 5 4 3 2 1 0 ptyp bit Explanation 0 1 2 When the CN4 connector of the drive unit and the power supply are connected, setting below is necessary. To validate the extern[...]

  • Page 155

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 149 No. Items Details Setting range Set “the motor inertia + motor axis conversion load inertia” in respect to the motor inertia. Jl+Jm SV037 (JL) = Jm *100 Jm: Motor inertia 2237 SV037 JL Load inertia scale Jl: Motor axis conversion load inertia 0 to 5000 (%) 2238 [...]

  • Page 156

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 150 No. Items Details Setting range 2246 SV046 Not used. Set to “0”. 0 2247 SV047 EC Inductive voltage compensation gain Set the inductive voltage compensation gain. Set to “100” as a standard. If the current FB peak exceeds the current command peak, lower the g[...]

  • Page 157

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 151 No. Items Details Setting range 2255 SV055 EMGx Max. gate off delay time after emergency stop Set a length of time from the point when the emergency stop is input to the point when READY OFF is compulsorily executed. Normally, set the same value as the absolute valu[...]

  • Page 158

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 152 (2) Initial setting value (a) HC**/HC**R series Motor HC 52 HC 102 HC 152 HC 202 HC 352 HC 452 HC 702 HC 902 Drive unit capacity 05 10 20 20 35 45 70 90 SV001 PC1 - - - - - - - - SV002 PC2 - - - - - - - - SV003 PGN1 33 33 33 33 33 33 33 33 SV004 PGN2 0 0 0 0 0 0 0 0[...]

  • Page 159

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 153 Motor HC 52 HC 102 HC 152 HC 202 HC 352 HC 452 HC 702 HC 902 Drive unit capacity 05 10 20 20 35 45 70 90 SV033 SSF2 0000 0000 0000 0000 0000 0000 0000 0000 SV034 SSF3 0003 0003 0003 0003 0003 0003 0003 0003 SV035 SSF4 0000 0000 0040 0040 0040 0040 0040 0040 SV036 PT[...]

  • Page 160

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 154 Motor HC 53 HC 103 HC 153 HC 203 HC 353 HC 453 HC 703 HC 103R HC 153R HC 203R HC 353R Drive unit capacity 05 10 20 35 45 70 90 10 10 20 35 SV001 PC1 - - - - - - - - - - - SV002 PC2 - - - - - - - - - - - SV003 PGN1 33 33 33 33 33 33 33 33 33 33 33 SV004 PGN2 0 0 0 0 [...]

  • Page 161

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 155 Motor HC 53 HC 103 HC 153 HC 203 HC 353 HC 453 HC 703 HC 103R HC 153R HC 203R HC 353R Drive unit capacity 05 10 20 35 45 70 90 10 10 20 35 SV033 SSF2 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 SV034 SSF3 0003 0003 0003 0003 0003 0003 0003 0000 0000 0000 [...]

  • Page 162

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 156 (b) HA**N series Motor HA 40N HA 80N HA 100N HA 200N HA 300N HA 700N HA 900N Drive unit capacity 05 10 20 35 45 70 90 SV001 PC1 - - - - - - - SV002 PC2 - - - - - - - SV003 PGN1 33 33 33 33 33 25 25 SV004 PGN2 0 0 0 0 0 0 0 SV005 VGN1 150 150 150 150 150 250 250 SV00[...]

  • Page 163

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 157 Motor HA 40N HA 80N HA 100N HA 200N HA 300N HA 700N HA 900N Drive unit capacity 05 10 20 35 45 70 90 SV033 SSF2 0000 0000 0000 0000 0000 0000 0000 SV034 SSF3 0000 0000 0000 0000 0000 0000 0000 SV035 SSF4 0000 0000 0000 0000 0000 0000 0000 SV036 PTYP 0000 0000 0000 0[...]

  • Page 164

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 158 Motor HA 43N HA 83N HA 93N HA 103N HA 203N HA 303N HA 703N Drive unit capacity 05 10 20 35 45 70 90 SV001 PC1 - - - - - - - SV002 PC2 - - - - - - - SV003 PGN1 33 33 33 33 33 33 25 SV004 PGN2 0 0 0 0 0 0 0 SV005 VGN1 150 150 150 150 150 150 250 SV006 VGN2 0 0 0 0 0 0[...]

  • Page 165

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 159 Motor HA 43N HA 83N HA 93N HA 103N HA 203N HA 303N HA 703N Drive unit capacity 05 10 20 35 45 70 90 SV033 SSF2 0000 0000 0000 0000 0000 0000 0000 SV034 SSF3 0000 0000 0000 0000 0000 0000 0000 SV035 SSF4 0000 0000 0000 0000 0000 0000 0000 SV036 PTYP 0000 0000 0000 00[...]

  • Page 166

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 160 Motor HA 053 HA 13 HA 053N HA 13N HA 23N HA 33N Drive unit capacity 01 01 01 01 03 03 SV001 PC1 - - - - - - SV002 PC2 - - - - - - SV003 PGN1 33 33 33 33 33 33 SV004 PGN2 0 0 0 0 0 0 SV005 VGN1 70 70 70 70 100 100 SV006 VGN2 0 0 0 0 0 0 SV007 VIL 0 0 0 0 0 0 SV008 VI[...]

  • Page 167

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 161 Motor HA 053 HA 13 HA 053N HA 13N HA 23N HA 33N Drive unit capacity 01 01 01 01 03 03 SV033 SSF2 0000 0000 0000 0000 0000 0000 SV034 SSF3 0000 0000 0000 0000 0000 0000 SV035 SSF4 0000 0000 0000 0000 0000 0000 SV036 PTYP 0000 0000 0000 0000 0000 0000 SV037 JL 0 0 0 0[...]

  • Page 168

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 162 (c) HA**L series Motor HA 50L HA 100L HA 150L HA 200L HA 300L HA 500L HA- A11KL HA- A15KL Drive unit capacity 05 10 10 20 35 45 110 150 SV001 PC1 - - - - - - - - SV002 PC2 - - - - - - - - SV003 PGN1 33 33 33 33 33 33 33 33 SV004 PGN2 0 0 0 0 0 0 0 0 SV005 VGN1 30 30[...]

  • Page 169

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 163 Motor HA 50L HA 100L HA 150L HA 200L HA 300L HA 500L HA- A11KL HA- A15KL Drive unit capacity 05 10 10 20 35 45 110 150 SV033 SSF2 0000 0000 0000 0000 0000 0000 0000 0000 SV034 SSF3 0000 0000 0000 0000 0000 0000 0000 0000 SV035 SSF4 0000 0000 0000 0000 0000 0000 0000[...]

  • Page 170

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 164 Motor HA 53L HA 103L HA 153L HA 203L HA 303L HA 503L Drive unit capacity 10 20 20 35 45 70 SV001 PC1 - - - - - - SV002 PC2 - - - - - - SV003 PGN1 33 33 33 33 33 33 SV004 PGN2 0 0 0 0 0 0 SV005 VGN1 30 30 30 30 30 50 SV006 VGN2 0 0 0 0 0 0 SV007 VIL 0 0 0 0 0 0 SV008[...]

  • Page 171

    7. Servo Parameters 7.3 MDS-C1-Vx Standard Speci fication (MDS-B-Vx Compatible) 165 Motor HA 53L HA 103L HA 153L HA 203L HA 303L HA 503L Drive unit capacity 10 20 20 35 45 70 SV034 SSF3 0000 0000 0000 0000 0000 0000 SV035 SSF4 0000 0000 0000 0000 0000 0000 SV036 PTYP 0000 0000 0000 0000 0000 0000 SV037 JL 0 0 0 0 0 0 SV038 FHz1 0 0 0 0 0 0 SV039 LM[...]

  • Page 172

    7. Servo Parameters 7.4 Supplement 166 7.4 Supplement 7.4.1 D/A Output Specifications (1) MDS-B-SVJ2 (a) D/A output specifications Item Explanation No. of channels 2ch Output cycle 888µs (min. value) Output precision 8bit Output voltage range -10V to 0 to +10V Output scale setting ± 1/256 to ± 128 times CN3 connector MO1 = pin 4 MO2 = pin 14 Out[...]

  • Page 173

    7. Servo Parameters 7.4 Supplement 167 (b) Setting the output data Set the No. of the data to be outputted to each D/A output channel. # No. Abbrev Parameter name 2261 SV061 DA1NO D/A output channel 1 data No. 2262 SV062 DA2NO D/A output channel 2 data No. No. Output data Standard output unit Output cycle 0 0V test output For offset amount adjustme[...]

  • Page 174

    7. Servo Parameters 7.4 Supplement 168 (c) Setting the output scale When “0“ is set, the output will be made with the standard output unit. To change the output unit, set a value other than “0”. The scale is set with a 1/256 unit. When 256 is set, the unit will be the same as the standard output. # No. Abbrev Parameter name 2263 SV063 DA1MP[...]

  • Page 175

    7. Servo Parameters 7.4 Supplement 169 (2) MDS-C1-Vx, MDS-B-Vx, MDS-B-Vx4 (a) D/A Output specifications Item Explanation No. of channels 2ch Output cycle 888µs (min. value) Output precision 8bit Output voltage 0V to 2.5V to +5V Output scale setting ± 1/256 to ± 128 times CN9 connector MO1 = pin 9 MO2 = pin 19 Output pins GND = pin 1,11 Phase cur[...]

  • Page 176

    7. Servo Parameters 7.4 Supplement 170 (b) Setting the output data Set the No. of the data to be outpu tted to each data D/A output channel. # No. Abbrev Parameter name 2261 SV061 DA1NO D/A output channel 1 data No. 2262 SV062 DA2NO D/A output channel 2 data No. No. Output data Standard output unit Standard setting value of output scale (Setting va[...]

  • Page 177

    7. Servo Parameters 7.4 Supplement 171 (Continued from the previous page) No. Output data Standard output unit Standard setting value of output scale (Setting values in SV063, SV064) Standard output unit Output cycle 77 Estimated disturbance torque Internal unit 8 (adjustment required) – 888µs 125 Saw-tooth wave test output 0V to 5V 0 (256) Cycl[...]

  • Page 178

    7. Servo Parameters 7.4 Supplement 172 7.4.2 Electronic Gears The servo drive unit has internal electronic gears. The command value from the NC is converted into a detector resolution unit to carry out position cont rol. The electronic gears are single gear ratios calculated from multiple parameters as shown below . However, each value (ELG1, ELG2)[...]

  • Page 179

    7. Servo Parameters 7.4 Supplement 173 7.4.3 Lost Motion Compensation When the motor is to rotate in the clockwise direction (looking from the load side) at the command for the + direction, the command direction is CW. C onversely, when the motor is to rotate in the counterclockwise direction, the command direction is CCW. This rotation direction c[...]

  • Page 180

    8. Spindle Parameters 8.1 Spindle Base Specifications Parameters 174 8. Spindle Parameters 8.1 Spindle Base Specifications Parameters For parameters indicated with a (PR) in the table, turn the NC power OFF after setting. The setting is validated after the power is turned ON again. No. Items Details Setting range (Unit) 3001 3002 3003 3004 slimit 1[...]

  • Page 181

    8. Spindle Parameters 8.1 Spindle Base Specifications Parameters 175 Relationship betw een spindle limit rotation speed and maximum spindle rotation speed 10V 0 sm ax1 slimt1 s max2 slim t2 sm ax ( n ) slimt ( n ) Output volt age (V ) Maximum rot at ion speed of gear 1 (Param eter s et t ing) Set "0" f or any unused gears. Limi t rot atio[...]

  • Page 182

    8. Spindle Parameters 8.1 Spindle Base Specifications Parameters 176 # Items Details Setting range (Unit) 3021 sori Orientation rotation speed Set the spindle orientation rotation speed. Set the rotation speed for when the spindle rotates at the constant rotation speed. 0 to 32767 (r/min) 3022 sgear Encoder gear ratio Set the gear ratio of the spin[...]

  • Page 183

    8. Spindle Parameters 8.1 Spindle Base Specifications Parameters 177 # Items Details Setting range (Unit) 3037 3038 3039 3040 tapt 21 22 23 24 Synchronized tapping Switching spindle rota- tion speed 2 Set the spindle rotation speed at which the step-2 acceleration/deceleration time constant is to be switched at gear 00, 01, 10, or 11. 0 to 99999 (r[...]

  • Page 184

    8. Spindle Parameters 8.1 Spindle Base Specifications Parameters 178 # Items Details Setting range (Unit) 3054 sptc1 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 1 Set the spindle speed for changing the 1st step's acceleration/deceleration time constant. 0 to 99999 (r/min) 3055 sptc2 Spindle synchroniza- tio[...]

  • Page 185

    8. Spindle Parameters 8.1 Spindle Base Specifications Parameters 179 # Items Details Setting range (Unit) 3060 sptc7 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 7 Set the spindle speed for changing the 7th step's acceleration/deceleration time constant. 0 to 99999 (r/min) 3061 spdiv1 Magnification for time [...]

  • Page 186

    8. Spindle Parameters 8.1 Spindle Base Specifications Parameters 180 # Items Details Setting range (Unit) 3066 spdiv6 Magnification for time constant changeover speed 6 Set the acceleration/deceleration time constant between the spindle synchronization multi-step acceleration/deceleration changeover speed 6 (sptc6) to the spindle synchronization mu[...]

  • Page 187

    8. Spindle Parameters 8.2 MDS-B-SPJ2 181 8.2 MDS-B-SPJ2 For parameters marked with a (PR) in the tables, turn the NC power OFF after setting. The parameters will be valid after the power is turned ON again. The valid spindle parameters will differ accordi ng to the motor and amplifier type. Follow the correspondence table given below, and set the c[...]

  • Page 188

    8. Spindle Parameters 8.2 MDS-B-SPJ2 182 No. Items Details Setting range Standard setting 3210 SP010 PGS Spindle synchronous position loop gain Set the spindle position loop gain in spindle synchronization mode. 1 to 100 (1/s) 15 3211 to 3216 SP011 to SP016 Use not possible. 0 0 3217 (PR) SP017 TSP Maximum motor speed Set the maximum motor speed of[...]

  • Page 189

    8. Spindle Parameters 8.2 MDS-B-SPJ2 183 No. Items Details Setting range Standard setting 3233 (PR) SP033 SFNC1 Spindle function 1 Set the spindle function 1 in bit units. 0000 to FFFF HEX setting 0000 3234 (PR) SP034 SFNC2 Spindle function 2 Set the spindle function 2 in bit units. (Note1) To validate bit3(mkc2), NC side needs to prepare. (Note1) [...]

  • Page 190

    8. Spindle Parameters 8.2 MDS-B-SPJ2 184 No. Items Details Setting range Standard setting 3235 (PR) SP035 SFNC3 Spindle function3 Set the spindle function 3 in bit units. 0000 to FFFF HEX setting 0000 3236 (PR) SP036 SFNC4 Spindle function 4 Set the spindle function 4 in bit units. F E D C B A 9 8 d s l m d s s m 7 6 5 4 3 2 1 0 enc2 enc1 mag2 mag1[...]

  • Page 191

    8. Spindle Parameters 8.2 MDS-B-SPJ2 185 No. Items Details Setting range Standard setting 3237 (PR) SP037 SFNC5 Spindle function 5 Set the spindle function 5 in bit units. 0000 to FFFF HEX setting 0000 3238 (PR) SP038 SFNC6 Spindle function 6 Set the spindle function 6 in bit units. (Note) Always set "0" for the empty bits. 0000 to FFFF H[...]

  • Page 192

    8. Spindle Parameters 8.2 MDS-B-SPJ2 186 No. Items Details Setting range Standard setting 3239 (PR) SP039 ATYP Amplifier type Set the amplifier type. Set each amplifier type or "0". This parameter corres ponds to MDS-B-SPJ2. 0000 to FFFF HEX setting 0000 3240 (PR) SP040 MTYP Motor type 0000 to FFFF HEX setting 0000 This is valid when SP03[...]

  • Page 193

    8. Spindle Parameters 8.2 MDS-B-SPJ2 187 No. Items Details Setting range Standard setting 3241 (PR) SP041 PTYP Power supply type When this unit is a signal connection axis with power supply unit, set this parameter. Set "0" for this parameter for the unit which is not a signal connection axis. Select a value from the following table accor[...]

  • Page 194

    8. Spindle Parameters 8.2 MDS-B-SPJ2 188 No. Items Details Setting range Standard setting 3248 (PR) SP048 SUT Speed reach range Set the speed deviation rate with respect to the commanded speed for output of the speed reach signal. 0 to 100 (%) 15 3249 SP049 TLM2 Torque limit 2 Set the torque limit rate for the torque limit signal 010. 1 to 120 (%) [...]

  • Page 195

    8. Spindle Parameters 8.2 MDS-B-SPJ2 189 No. Items Details Setting range Standard setting 3267 (PR) SP067 VIGWA Change starting speed of variable current loop gain Set the speed for starting change of current loop gain. 0 to 32767 (r/min) 0 3268 (PR) SP068 VIGWB Change ending speed of variable current loop gain Set the speed for ending change of cu[...]

  • Page 196

    8. Spindle Parameters 8.2 MDS-B-SPJ2 190 No. Items Details Setting range Standard setting 3276 SP076 Not used. Set to “0”. 0 0 3277 SP077 TDSL Fixed control constant Set by Mitsubish i. Set "0" unless designated in particular. 0 0 3278 (PR) SP078 FPWM 3279 (PR) SP079 ILMT 3280 SP080 3281 SP081 LMCA 3282 SP082 LMCB 3283 to 3286 SP083 t[...]

  • Page 197

    8. Spindle Parameters 8.2 MDS-B-SPJ2 191 No. Items Details Setting range Standard setting 3296 (PR) SP096 EGAR Encoder gear ratio Set the gear ratio between the spindle end and the encoder end (except for the motor-built-in encoder) as indicated below. Setting value G ear r ati o (A ccelerati on) –1 1 : 2 –2 1 : 4 –3 1 : 3 Setting value Gear [...]

  • Page 198

    8. Spindle Parameters 8.2 MDS-B-SPJ2 192 No. Items Details Setting range Standard setting 3301 (PR) SP101 DINP Orientation advance in-position width When using the orientation in-position advance function, set the in-position width that is larger than the normal in-position width defined in SP004 (OINP). 1 to 2880 (1/16°) 16 3302 (PR) SP102 OODR E[...]

  • Page 199

    8. Spindle Parameters 8.2 MDS-B-SPJ2 193 No. Items Details Setting range Standard setting 3313 (PR) SP113 WINP Turret index in-position width The position error range is set in which an orientation (indexing) completed signal is output during turret indexing. This becomes the same as SP004 (OINP) when set to "0". 0 to 32767 (1/16°) 0 331[...]

  • Page 200

    8. Spindle Parameters 8.2 MDS-B-SPJ2 194 No. Items Details Setting range Standard setting 3377 (PR) SP177 SPECS Spindle synchronous specifica- tions Set the spindle synchronous specifications in bit units. 0000 to FFFF HEX setting 0000 3378 (PR) SP178 VGSP Spindle synchronous speed loop gain propor- tional term Set the speed loop proportional gain [...]

  • Page 201

    8. Spindle Parameters 8.2 MDS-B-SPJ2 195 No. Items Details Setting range Standard setting 3382 (PR) SP182 VCSS Change starting speed of variable speed loop proportional gain at spindle synchroniza-ti on Set the speed for starting change of speed loop proportional gain at spindle synchronization. SP182 SP017 SP178 SP178× (SP181/100) Proporti onal g[...]

  • Page 202

    8. Spindle Parameters 8.2 MDS-B-SPJ2 196 No. Items Details Setting range Standard setting 3393 (PR) SP193 SPECT Synchronous tapping specifications Set the synchronous tapping specifications in bit units. 0000 to FFFF HEX setting 0000 3394 (PR) SP194 VGTP Synchronous tapping speed loop gain propor- tional term Set the speed loop proportional gain in[...]

  • Page 203

    8. Spindle Parameters 8.2 MDS-B-SPJ2 197 No. Items Details Setting range Standard setting 3399 (PR) SP199 VCST Change starting speed of variable speed loop proportional gain at synchronous tapping Set the speed for starting change of speed loop proportional gain at synchronous tapping. SP199 SP017 SP194 SP194× (SP198/100) Speed Proportion al gai n[...]

  • Page 204

    8. Spindle Parameters 8.2 MDS-B-SPJ2 198 No. Items Details Setting range Standard setting 3417 SP217 TINP Synchronous tapping in-position width Set the position error range in which in-position signal is output during synchronize tapping. 1 to 2880 (1/16°) 16 3418 (PR) SP218 TODR Excessiv e error width at synchronous tapping Set the excessive erro[...]

  • Page 205

    8. Spindle Parameters 8.2 MDS-B-SPJ2 199 No. Items Details Setting range Standard setting 3434 (PR) SP234 OBS1 Disturbanc e observer low path filter frequency Set the frequency of the low path filter for when the disturbance observer is valid. Setting (1/s) = 2 π f f: Approx. 1.5 times the disturbance frequency 0 to 1000 (1/s) 0 3435 (PR) SP235 OB[...]

  • Page 206

    8. Spindle Parameters 8.2 MDS-B-SPJ2 200 No. Items Details Setting range Standard setting 3457 (PR) to 3520 (PR) SP257 to SP320 RPM BSD Motor constant (H coil) This parameter is valid only in the following two conditional cases: (a) In case that SP034 (SFNC2) bit0=1 and SP034 (SFNC2) bit2=0 Set the motor constants when using a special motor, not de[...]

  • Page 207

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 201 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH The spindle parameter setting and display method will di ffer according to the NC being used, so refer to Instruction Manual for each NC and the following spindles. MELDAS AC Servo and Spindle MDS-A Series MD S-B Series Specifications Manual . BNP-B3759 MELDA[...]

  • Page 208

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 202 No. Items Details Setting range Standard setting 3207 SP007 OPST In-position shift amount for orientation Set the stop position for orientation. (i)Motor built-in encoder, encoder: Set the value by dividing 360° by 4096. (ii)Magnetic sensor: Divide –5° to +5° by 1024 and put 0° for 0.[...]

  • Page 209

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 203 No. Items Details Setting range Standard setting 3224 SP024 Use not possible. 0 0 3225 (PR) SP025 GRA1 Spindle gear teeth count 1 Set the number of gear teeth of the spindle corresponding to gear 000. 1 to 32767 1 3226 (PR) SP026 GRA2 Spindle gear teeth count 2 Set the number of gear teeth [...]

  • Page 210

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 204 No. Items Details Setting range Standard setting 3233 (PR) SP033 SFNC1 Spindle function 1 Set the spindle function 1 in bit units. 0000 to FFFF HEX setting 0000 F E D C B A 9 8 poff hzs ront pycal pychg 7 6 5 4 3 2 1 0 pyst pyoff sftk dflt 1a2m (Note) Alwa ys set "0" for the empty[...]

  • Page 211

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 205 No. Items Details Setting range Standard setting 3234 (PR) SP034 SFNC2 Spindle function 2 Set the spindle function 2 in bit units. 0000 to FFFF HEX setting 000C 3235 (PR) SP035 SFNC3 Spindle function 3 Set the spindle function 3 in bit units. 0000 to FFFF HEX setting 0000 F E D C B A 9 8 7 [...]

  • Page 212

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 206 No. Items Details Setting range Standard setting 3236 (PR) SP036 SFNC4 Spindle function 4 Set the spindle function 4 in bit units. 0000 to FFFF HEX setting 0000 3237 (PR) SP037 SFNC5 Spindle function 5 Set the spindle function 5 in bit units. 0000 to FFFF HEX setting 0000 F E D C B A 9 8 d [...]

  • Page 213

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 207 No. Items Details Setting range Standard setting 3238 (PR) SP038 SFNC6 Spindle function 6 Set the spindle function 6 in bit units. 0000 to FFFF HEX setting 0000 (Note) Always s et "0" for the empty bits. For MDS-C1-SP/SPH For MDS-B-SP/SPH bit Name Meaning when set to 0 Meaning w h[...]

  • Page 214

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 208 No. Items Details Setting range Standard setting 3239 (PR) SP039 ATYP Amplifier type Set the amplifier type. Set each amplifier type or "0" Parameter setting A mplifi er ty pe 0000 0001 S P-075 0002 S P-15 0003 S P-22 0004 S P-37 0005 S P-55 0006 S P-75 0007 S P-110 0008 S P-150 0[...]

  • Page 215

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 209 No. Items Details Setting range Standard setting 3240 (PR) SP040 MTYP Motor type This parameter is valid when SP034 (SFNC2) bit0 is set to "0". Set the appropriate motor number from the standard motors listed below. 0000 to FFFF HEX setting 0000 Parameter setting Motor ty pe Maxim[...]

  • Page 216

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 210 No. Items Details Setting range Standard setting 3241 (PR) SP041 PTYP Power supply type Power supply type 0000 to FFFF HEX setting 0000 3242 (PR) SP042 CRNG C-axis detector range This parameter is used to set the C-axis detector range. Set "0" for this parameter. "2" is [...]

  • Page 217

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 211 No. Items Details Setting range Standard setting 3243 (PR) SP043 TRNG Synchro- nous tapping, spindle synchro- nous detector range This parameter is used to set the synchronous tapping or spindle synchronous detector range. Set "0" for this parameter. 0 to 7 0 3244 (PR) SP044 TRANS[...]

  • Page 218

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 212 No. Items Details Setting range Standard setting 3255 (PR) SP055 SETM Excessive speed deviation timer Set the timer value until the excessive speed deviation alarm is output. The value of this parameter should be longer than the acceleration/deceleration time. 0 to 60 (s) 12 3256 SP056 PYVR[...]

  • Page 219

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 213 No. Items Details Setting range Standard setting 3263 (PR) SP063 OLT Overload alarm detection time Set the time constant for detection of the motor overload alarm. 0 to 1000 (s) 60 3264 (PR) SP064 OLL Ov erl oad alarm detection level Set the detection level of the motor overload alarm. 0 to[...]

  • Page 220

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 214 No. Items Details Setting range Standard setting 3270 SP070 FHz Machine resonance suppressio n filter frequency When machine vibration occurs in speed and position control, set the frequency of the required vibration suppression. Note that a value of 100Hz or more is set. Set to "0&quo[...]

  • Page 221

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 215 No. Items Details Setting range Standard setting 3280 SP080 Use not possible. 0 0 3281 SP081 LMCA 3282 SP082 LMCB 3283 SP083 Fixed control constant This is used by Mitsubishi. Set to "0" unless particularly designated. 0 0 3284 to 3286 SP084 to SP086 Use not possible. 0 0 3287 (PR[...]

  • Page 222

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 216 No. Items Details Setting range Standard setting 3296 (PR) SP096 EGAR Encoder gear ratio Set the gear ratio between the spindle end and the encoder end (except for the motor-built-in encoder) as indicated below. Setting value Gear ratio (accelerati on) –1 1 : 2 –2 1 : 4 –3 1 : 3 Setti[...]

  • Page 223

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 217 No. Items Details Setting range Standard setting 3298 (PR) SP098 VGOP Speed loop gain propor- tional term in orientation mode Set the speed loop proportional gain in orientation mode. When the gain is increased, rigidity is improved in the orientation stop but vibration and sound become lar[...]

  • Page 224

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 218 No. Items Details Setting range Standard setting 3308 SP108 CSP3 Deceleration rate 3 in orientation mode Set the deceleration rate in orientation mode corresponding to the gear 010. When this parameter is set to "0", same as SP006 (CSP). 0 to 1000 0 3309 SP109 CSP4 Deceleration ra[...]

  • Page 225

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 219 No. Items Details Setting range Standard setting 3320 SP120 MPGL Orientation position gain L winding compensa- tion magnifi- cation Set the compensation magnification of the orientation position loop gain for the L winding. L winding orientation position loop gain = SP001 (or SP002) × SP12[...]

  • Page 226

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 220 No. Items Details Setting range Standard setting 3325 SP125 MGD2 Magnetic sensor switching point This parameter is used for adjustment of orientation operation of the magnetic sensor. Set the distance dimension from the target stop point at switching from position feedback to magnetic senso[...]

  • Page 227

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 221 No. Items Details Setting range Standard setting 3332 SP132 PGC3 Third position loop gain for cutting on C-axis Set the position loop gain when the third gain is selected for C-axis cutting. 1 to 100 (1/s) 15 3333 SP133 PGC4 Stop position loop gain for cutting on C-axis Set the position loo[...]

  • Page 228

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 222 No. Items Details Setting range Standard setting 3341 (PR) SP141 VGCI2 Second speed loop gain integral item for cutting on C-axis Set the speed loop integral gain when the second gain is selected for C-axis cutting. 0 to 5000 (0.1 1/s) 60 3342 (PR) SP142 VGCD2 Second speed loop gain delay a[...]

  • Page 229

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 223 No. Items Details Setting range Standard setting 3349 SP149 CZRN C-axis zero point return speed This parameter is valid when SP129 (SPECC) bitE is set to "0". Set the zero point return speed used when the speed loop changes to the position loop. 1 to 500 (r/min) 50 3350 SP150 CPDT[...]

  • Page 230

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 224 No. Items Details Setting range Standard setting 3361 (PR) SP161 IQGC0 Current loop gain magnifi- cation 1 for non-cutting on C-axis Set the magnification of current loop gain (torque component) for C-axis non-cutting. 1 to 1000 (%) 100 3362 (PR) SP162 IDGC0 Current loop gain magnifi- catio[...]

  • Page 231

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 225 No. Items Details Setting range Standard setting 3370 (PR) SP170 V G U D Speed loop gain delay advance item for increased spindle holding force Set the speed loop gain delay advance item for when the disturbance observer is valid. 0 to 5000 (0.1 1/s) 15 3371 to 3376 SP171 to SP176 Not used.[...]

  • Page 232

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 226 No. Items Details Setting range Standard setting 3380 (PR) SP180 VGSD Spindle synchronous speed loop gain delay advance term Set the speed loop delay advance gain in spindle synchronous mode. When this parameter is se t to "0", PI control is applied. 0 to 1000 (0.1 1/s) 15 3381 (P[...]

  • Page 233

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 227 No. Items Details Setting range Standard setting 3388 (PR) SP188 IDGS Spindle synchronous Current loop gain magnifi- cation 2 Set the magnification of current loop gain (excitation component) in the spindle synchronous mode. 1 to 1000 (%) 100 3389 SP189 PG2S Spindle synchronous Position loo[...]

  • Page 234

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 228 No. Items Details Setting range Standard setting 3394 (PR) SP194 VGTP Synchronized tapping speed loop gain proportional term Set the speed loop proportional gain in synchronized tapping mode. 0 to 1000 (1/s) 63 3395 (PR) SP195 VGTI Synchronized tapping speed loop gain integral term Set the [...]

  • Page 235

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 229 No. Items Details Setting range Standard setting 3403 (PR) SP203 FFC4 Synchronized tapping acceleration feed forward gain (gear 4) Set the acceleration feed forward gain for selection of gear 011 during synchronized tapping. 0 to 1000 (%) 0 3404 to 3413 SP204 to SP213 Not used. Set to "[...]

  • Page 236

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 230 No. Items Details Setting range Standard setting 3421 SP221 PG2T Synchronized tapping position loop gain 2 Set the second position loop gain when high-gain control is applied during synchronized tapping. When this parameter is not used, set to "0". 0 to 999 (1/s) 0 3422 SP222 PG3T[...]

  • Page 237

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 231 No. Items Details Setting range Standard setting 3433 (PR) SP233 JL Disturbance observer general inertia scale Set the ratio of the motor inertia + load inertia and motor inertia. = ×10 0 Motor inertia + load inertia Motor inertia Setting value (Normally, set "100" or more. When [...]

  • Page 238

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 232 No. Items Details Setting range Standard setting 3453 SP253 DA1NO D/A output channel 1 data number Set the output data number for channel 1 of the D/A output function. When set to "0", the output is speedometer. Refer to "9.4 (1) For D/A output functions". –32768 to 32[...]

  • Page 239

    8. Spindle Parameters 8.3 MDS-B-SP/SPH , MDS-C1-SP/SPH 233 No. Items Details Setting range Standard setting 3457 (PR) to 3520 (PR) SP257 to SP320 RPM BSD Motor constant (H coil) This parameter is valid only in the following two conditional cases: (a) In case that SP034 (SFNC2) bit0=1 and SP034 (SFNC2) bit2=0 Set the motor constants when using a spe[...]

  • Page 240

    8. Spindle Parameters 8.4 MDS-C1-SPM 234 8.4 MDS-C1-SPM The spindle parameter setting and display method will di ffer according to the NC being used, so refer to Instruction Manual for each NC and the following spindles. MELDAS AC Servo and Spindle MDS-C1 Seri es Specifications Manual ........................ BNP-C3000 For parameters marked with a [...]

  • Page 241

    8. Spindle Parameters 8.4 MDS-C1-SPM 235 No. Items Details Setting range Standard setting 3209 SP009 PGT Synchronized tapping Position loop gain Set the spindle position loop gain in synchronized tapping mode. 1 to 200 (1/s) 15 3210 SP010 PGS Spindle synchronous position loop gain Set the spindle position loop gain in spindle synchronization mode. [...]

  • Page 242

    8. Spindle Parameters 8.4 MDS-C1-SPM 236 No. Items Details Setting range Standard setting 3230 (PR) SP030 GRB2 Motor shaft gear teeth count 2 Set the number of gear teeth of the motor shaft corresponding to gear 001. 1 to 32767 1 3231 (PR) SP031 GRB3 Motor shaft gear teeth count 3 Set the number of gear teeth of the motor shaft corresponding to gea[...]

  • Page 243

    8. Spindle Parameters 8.4 MDS-C1-SPM 237 No. Items Details Setting range Standard setting 3234 (PR) SP034 SFNC2 Spindle function 2 Set the spindle function 2 in bit units. 0000 to FFFF HEX setting 000C F E D C B A 9 8 7 6 5 4 3 2 1 0 mkc2 mkch Mk3c mts1 (Note) Alway s set "0" for the empty bits. bit Name Meaning when set to 0 Meaning w he[...]

  • Page 244

    8. Spindle Parameters 8.4 MDS-C1-SPM 238 No. Items Details Setting range Standard setting 3235 (PR) SP035 SFNC3 Spindle function 3 Set the spindle function 3 in bit units. 0000 to FFFF HEX setting 0000 F E D C B A 9 8 7 6 5 4 3 2 1 0 mwid lwid hwid (Note) Alway s set "0" for the empty bits. bit Name Meaning when set to 0 Meaning w hen set[...]

  • Page 245

    8. Spindle Parameters 8.4 MDS-C1-SPM 239 No. Items Details Setting range Standard setting 3236 SP036 Not used. Set to "0". 3237 (PR) SP037 SFNC5 Spindle function 5 Set the spindle function 5 in bit units. 0000 to FFFF HEX setting 0000 F E D C B A 9 8 nsno nosg 7 6 5 4 3 2 1 0 plgo enco (Note) Alway s set "0" for the empty bits. [...]

  • Page 246

    8. Spindle Parameters 8.4 MDS-C1-SPM 240 No. Items Details Setting range Standard setting 3238 (PR) SP038 SFNC6 Spindle function 6 Set the spindle function 6 in bit units. 0000 to FFFF HEX setting 0000 F E D C B A 9 8 XFzs pl80 sdt2 7 6 5 4 3 2 1 0 hzrn orm tdn plg2 pftm alty (Note) Alway s set "0" for the empty bits. bit Name Meaning whe[...]

  • Page 247

    8. Spindle Parameters 8.4 MDS-C1-SPM 241 No. Items Details Setting range Standard setting 3239 (PR) SP039 ATYP Amplifier type Set the amplifier type. Set each amplifier type or "0" Parameter setting A mplifi er ty pe 0000 –– 0001 –– 0002 –– 0003 –– 0004 –– 0005 –– 0006 –– 0007 S PM-110 0008 S PM-150 0009 S PM-1[...]

  • Page 248

    8. Spindle Parameters 8.4 MDS-C1-SPM 242 No. Items Details Setting range Standard setting 3241 (PR) SP041 PTYP Power supply type Power supply type 0000 to FFFF HEX setting 0000 3242 (PR) SP042 CRNG C-axis detector range This parameter is used to set the C-axis detector range. Set "0" for this parameter. "2" is used by Mitsubishi[...]

  • Page 249

    8. Spindle Parameters 8.4 MDS-C1-SPM 243 No. Items Details Setting range Standard setting 3243 (PR) SP043 TRNG Synchronous tapping, spindle synchronous detector range This parameter is used to set the synchronous tapping or spindle synchronous detector range. Set "0" for this parameter. 0 to 7 0 3244 (PR) SP044 TRAN S NC communi- cation f[...]

  • Page 250

    8. Spindle Parameters 8.4 MDS-C1-SPM 244 No. Items Details Setting range Standard setting 3256 SP056 Use not possible. 0 0 3257 (PR) SP057 STOD Constant → excessive judgment value Set the value for judging when changing from a constant to excessive speed command. 0 to 50 (r/min) 0 3258 (PR) SP058 SDT2 2nd speed detection speed Set the speed for t[...]

  • Page 251

    8. Spindle Parameters 8.4 MDS-C1-SPM 245 No. Items Details Setting range Standard setting 3266 (PR) SP066 VCSN1 Change starting speed of variable speed loop proportional gain Set the speed when the speed loop proportional gain change starts. SP066 SP017 SP022 SP022× (SP065/100) Proportional gain Speed 0 to 32767 (r/min) 0 3267 (PR) SP067 VIGWA Cha[...]

  • Page 252

    8. Spindle Parameters 8.4 MDS-C1-SPM 246 No. Items Details Setting range Standard setting 3276 SP076 FONS Machine resonance suppression filter operation speed When the vibration increases in motor stop (ex. in orientation stop) when the machine vibration suppression filter is operated by SP070, operate the machine vibration suppression filter at a [...]

  • Page 253

    8. Spindle Parameters 8.4 MDS-C1-SPM 247 No. Items Details Setting range Standard setting 3296 (PR) SP096 EGAR Encoder gear ratio Set the gear ratio between the spindle end and the encoder end (except for the motor-built-in encoder) as indicated below. Setting value Gear ratio (decele ration) 0 1 : 1 1 1 : 2 2 1 : 4 3 1 : 8 4 1 : 1 6 (Note) Use a c[...]

  • Page 254

    8. Spindle Parameters 8.4 MDS-C1-SPM 248 No. Items Details Setting range Standard setting 3298 (PR) SP098 VGOP Speed loop gain propor- tional term in orientation mode Set the speed loop proportional gain in orientation mode. When the gain is increased, rigidity is improved in the orientation stop but vibration and sound become larger. 0 to 2000 (1/[...]

  • Page 255

    8. Spindle Parameters 8.4 MDS-C1-SPM 249 No. Items Details Setting range Standard setting 3309 SP109 CSP4 Deceleration rate 4 in orientation mode Set the deceleration rate in orientation mode corresponding to the gear 011. When this parameter is set to "0", same as SP006 (CSP). 0 to 1000 0 3310 to 3313 SP110 to SP003 Use not possible. 0 3[...]

  • Page 256

    8. Spindle Parameters 8.4 MDS-C1-SPM 250 No. Items Details Setting range Standard setting 3321 SP121 MPCSH Orientation deceleration rate H winding compensa- tion magnifi- cation Set the compensation magnification of the orientation deceleration rate for the H winding. Orientation deceleration rate for the H winding = SP006 × SP121/256 When set to [...]

  • Page 257

    8. Spindle Parameters 8.4 MDS-C1-SPM 251 No. Items Details Setting range Standard setting 3329 (PR) SP129 SPECC C-axis specifica- tions Set the C-axis specific ations in bit units. 0000 3330 SP130 PGC1 First position loop gain for cutting on C-axis Set the position loop gain when the first gain is selected for C axis cutting. 1 to 200 (1/s) 15 F E [...]

  • Page 258

    8. Spindle Parameters 8.4 MDS-C1-SPM 252 No. Items Details Setting range Standard setting 3331 SP131 PGC2 Second position loop gain for cutting on C-axis Set the position loop gain when the second gain is selected for C axis cutting. 1 to 200 (1/s) 15 3332 SP132 PGC3 Third position loop gain for cutting on C-axis Set the position loop gain when the[...]

  • Page 259

    8. Spindle Parameters 8.4 MDS-C1-SPM 253 No. Items Details Setting range Standard setting 3343 (PR) SP143 VGCP3 Third speed loop gain proportional item for cutting on C-axis Set the speed loop proportional gain when the third gain is selected for C-axis cutting. 0 to 5000 (1/s) 63 3344 (PR) SP144 VGCI3 Third speed loop gain integral item for cuttin[...]

  • Page 260

    8. Spindle Parameters 8.4 MDS-C1-SPM 254 No. Items Details Setting range Standard setting 3353 SP153 CINP C-axis in-position width Set the position error range in which the in-position signal is output on the C-axis. 0000 to FFFF (1/1000°) HEX setting 03E8 3354 (PR) SP154 CODRL Excessive error width on C-axis (low byte) 3355 (PR) SP155 CODRH Exces[...]

  • Page 261

    8. Spindle Parameters 8.4 MDS-C1-SPM 255 No. Items Details Setting range Standard setting 3366 SP166 PG3C C-axis position loop gain 3 Set the third position loop gain when high-gain control is carried out for control of the C-axis. This parameter is applied to all the operation modes of C-axis control. When this function is not used, assign "0[...]

  • Page 262

    8. Spindle Parameters 8.4 MDS-C1-SPM 256 No. Items Details Setting range Standard setting 3377 (PR) SP177 SPECS Spindle synchronous specifica- tions Set the spindle synchronous specifications in bit units. 0000 to FFFF HEX setting 0000 3378 (PR) SP178 VGSP Spindle synchronous speed loop gain propor- tional term Set the speed loop proportional gain [...]

  • Page 263

    8. Spindle Parameters 8.4 MDS-C1-SPM 257 No. Items Details Setting range Standard setting 3382 (PR) SP182 VCSS Spindle synchronous Change starting speed of variable speed loop proportional gain Set the speed when the speed loop proportional gain change starts in the spindle synchronous mode. SP182 SP017 SP178 SP178× (SP181/ 100) Proportion al gai [...]

  • Page 264

    8. Spindle Parameters 8.4 MDS-C1-SPM 258 No. Items Details Setting range Standard setting 3390 SP190 PG3S Spindle synchronous Position loop gain 3 Set the third position loop gain when high-gain control is carried out in the spindle synchronous mode. When this parameter function is not used, set to "0". 0 to 999 (1/s) 0 3391 SP191 Use not[...]

  • Page 265

    8. Spindle Parameters 8.4 MDS-C1-SPM 259 No. Items Details Setting range Standard setting 3394 (PR) SP194 VGTP Synchronized tapping speed loop gain proportional term Set the speed loop proportional gain in synchronized tapping mode. 0 to 2000 (1/s) 63 3395 (PR) SP195 VGTI Synchronized tapping speed loop gain integral term Set the speed loop integra[...]

  • Page 266

    8. Spindle Parameters 8.4 MDS-C1-SPM 260 No. Items Details Setting range Standard setting 3400 (PR) SP200 FFC1 Synchronized tapping acceleration feed forward gain (gear 1) Set the acceleration feed forward gain for selection of gear 000 during synchronized tapping. This parameter should be used when an error of relative position to Z-axis servo is [...]

  • Page 267

    8. Spindle Parameters 8.4 MDS-C1-SPM 261 No. Items Details Setting range Standard setting 3407 SP207 GDL Sequential mode startup timing To carry out spindle synchronization or C-axis control in the both-chuck state with no movement immediately after the power is turned ON, set this parameter so that the reverse run detection function will function [...]

  • Page 268

    8. Spindle Parameters 8.4 MDS-C1-SPM 262 No. Items Details Setting range Standard setting 3417 SP217 TINP Synchronized tapping in-position width Set the position error range for output of the in-position during synchronized tapping. 1 to 2880 (1/16°) 16 3418 (PR) SP218 TODR Synchronized tapping excessive error width Set the excessive error width d[...]

  • Page 269

    8. Spindle Parameters 8.4 MDS-C1-SPM 263 No. Items Details Setting range Standard setting 3425 SP225 OXKPH Position loop gain magni- fication after orientation gain changeover (H coil) 0 to 2560 (1/256-fold) 0 3426 SP226 OXKPL Position loop gain magni- fication after orientation gain changeover (L coil) 0 to 2560 (1/256-fold) 0 3427 SP227 OXVKP Spe[...]

  • Page 270

    8. Spindle Parameters 8.4 MDS-C1-SPM 264 No. Items Details Setting range Standard setting 3435 (PR) SP235 OBS2 Disturbance observer gain Set the gain for the disturbance observer. 0 to 500 (%) 0 3436 SP236 OBS3 Fixed control constant This is used by Mitsubishi. Set to "0" unless particularly designated. 0 0 3437 SP237 KSCP 3438 SP238 SEZR[...]

  • Page 271

    8. Spindle Parameters 8.4 MDS-C1-SPM 265 No. Items Details Setting range Standard setting 3453 SP253 DA1NO D/A output channel 1 data number Set the output data number for channel 1 of the D/A output function. When set to "0", the output is speedometer. Refer to "9.4 (1) For D/A output functions". –32768 to 32767 0 3454 SP254 D[...]

  • Page 272

    8. Spindle Parameters 8.5 Supplement 266 8.5 Supplement 8.5.1 D/A Output Specifications (1) D/A output specifications Item Explanation No. of channels 2ch Output cycle 444µs (min. value) Output precision 8bit Output voltage range 0V to +5V (zero) to +10V, 0V to +10V during meter output Output scale setting 1/256 to ± 128 tiems Output pins CN9 con[...]

  • Page 273

    8. Spindle Parameters 8.5 Supplement 267 (2) Setting the output data Input the No. of the data to be output to each D/A output channel. # No. Abbrev Parameter name 3453 SP253 DA1NO D/A output channel 1 data No. 3454 SP254 DA2NO D/A output channel 2 data No. No. Output data Original data unit Standard setting value for output scale (Setting values i[...]

  • Page 274

    8. Spindle Parameters 8.5 Supplement 268 (3) Setting the output scale # No. Abbrev Parameter name 3455 SP255 DA1MPY D/A output channel 1 magnification 3456 SP256 DA2MPY D/A output channel 2 magnification Usually, the standard setting value is set for the output scale (SV063, SV 064). When “0” is set, the output will be made as well as when “2[...]

  • Page 275

    9. Machine Error Compensation 9.1 Function Outline 269 9. Machine Error Compensation 9.1 Function Outline Machine error compensation includes two independent functions: memorized pitch error compensation and memorized relative position compensation. (1) Memorized pitch error compensation According to the specified parameters‚ this me thod compens[...]

  • Page 276

    9. Machine Error Compensation 9.1 Function Outline 270 (2) Memorized relative position compensation This method‚ according to the parameters specifi ed in advance‚ compensates the relative position error between two orthogonal axes caused by deflection of the moving stand. For this‚ as shown in the following figure‚ spec ify the compensatio[...]

  • Page 277

    9. Machine Error Compensation 9.1 Function Outline 271 # Item Details Setting range 4000 (PR) Pinc Machine error offset increment method Specify whether the incremental volume method or absolute volume method is to be used to set machine error offset data. 0: Absolute volume method 1: Incremental volume method <1st axis> # Item Details Settin[...]

  • Page 278

    9. Machine Error Compensation 9.1 Function Outline 272 # Item Details Setting range 4101 y y y 5124 Set the compensation amount for each axis. –128 to 127 The actual compensation amount will be the value obtained by multiplying the setting value with the compensation scale.[...]

  • Page 279

    9. Machine Error Compensation 9.2 Setting Compensation Data 273 9.2 Setting Compensation Data Compensation data can be set according to either absolute or incremental system. "#4000:Pinc" 0: Absolute system 1: Incremental system (1) Absolute system Feed from the reference point to each division point is executed as shown in the following [...]

  • Page 280

    9. Machine Error Compensation 9.2 Setting Compensation Data 274 (2) Incremental system The following figure (left) contains a machine position that is placed in the positive direction with respect to the reference point. Assume that f eed from division n–1 to n (division interval) is executed. In this case‚ the following va lue is defined as th[...]

  • Page 281

    9. Machine Error Compensation 9.3 Example in Using a Linear Axis as the Base Axis 275 9.3 Example in Using a Linear Axis as the Base Axis (1) When "mdvno" or "pdv no" exists at both ends of "rdvno": Division point number #4101 #4102 #4103 #4104 #4105 #4106 rdvno 4103 Specified machine position − 300.000 − 200.000 ?[...]

  • Page 282

    9. Machine Error Compensation 9.3 Example in Using a Linear Axis as the Base Axis 276 (3) When the range compensated is only the negative range: Division point number #4125 #4126 #4127 #4128 #4129 #4130 rdvno 4130 Compensation Incremental − 2 2 6 2 0 − 6 mdvno 4125 amount Absolute − 2 − 4 − 2 4 6 6 pdvno 4130 If the machine position excee[...]

  • Page 283

    9. Machine Error Compensation 9.4 Example in Using a Rotation Axis as the Base Axis 277 9.4 Example in Using a Rotation Axis as the Base Axis Division point number #4123 #4124 #4125 #4126 #4127 #4128 rdvno 4122 Compensation Incremental − 4 2 0 6 2 − 6 mdvno 4123 amount Absolute − 4 − 2 − 2 4 6 0 pdvno 4128 In this case‚ the sum of the c[...]

  • Page 284

    10. PLC Constants 10.1 PLC Timer 278 10. PLC Constants 10.1 PLC Timer (SETUP PARAM 6. 1/6) to (SETUP PARAM 6. 2/6) # PLC device Item Details Setting range 6000 6015 T000 T015 10ms adding timer <10ms> Set the time for the timer used in the PLC program (ladder). (Note) This setting value is valid when parameter "#6449 bit0" in the fol[...]

  • Page 285

    10. PLC Constants 10.3 PLC Constants 279 10.3 PLC Constants (SETUP PARAM 6. 4/6) # PLC device Item Details Setting range 6301 6348 R4500,4501 R4594,4595 PLC c ons ta nt Set the value to be set in the data type R register used in the PLC program (ladder). Even if the data is set in the R register that corresponds to the PLC side when this parameter [...]

  • Page 286

    10. PLC Constants 10. 4 PLC Bit Selection 280 10.4 PLC Bit Selection (SETUP PARAM 6. 5/6) to (SETUP PARAM 6. 6/6) # PLC device Item Details Setting range 6401 6402 6495 6496 R4600-Low R4600-High R4647-Low R4647-High Bit selection This is the bit type parameter used in the PLC program (ladder). Even if the data is set in the R register that correspo[...]

  • Page 287

    10. PLC Constants 10. 4 PLC Bit Selection 281 Table: "Contents of bit sele ction parameters #6449 to #6496" Symbol name 7 6 5 4 3 2 1 0 0 #6449 R2924 L NC card Controller thermal alarm disable Setting display unit thermal alarm disable - Counter C retention Integrating timer T retention PLC counter program on PLC timer program on 1 0 1 #6[...]

  • Page 288

    10. PLC Constants 10. 4 PLC Bit Selection 282 Symbol name 7 6 5 4 3 2 1 0 0 #6465 R2932 L - - - - - - - - 1 #6466 R2932 H - - - - - - - - 2 #6467 R2933 L - - - - - - - - 3 #6468 R2933 H 4 #6469 R2934 L - NC alarm output disable 5 #6470 R2934 H 6 #6471 R2935 L - - - - - - - - 7 #6472 R2935 H - - - - - - - - 8 #6473 R2936 L - - 9 #6474 R2936 H A #647[...]

  • Page 289

    11. Macro List 283 11. Macro List # Item Details Setting range (unit) 7001 to 7091 M [01] to M [10] <Code> Set the M code used for calling out the macro with the M command. This is valid when "#1195 Mmac" is set to 1. 1 to 9999 7002 to 7092 <Type> Set the macro call out type. 0 to 3 7003 to 7093 <Program No.> Set the No.[...]

  • Page 290

    12. Position Sw itch 12.1 Outline of Function 284 12. Position Switch 12.1 Outline of Function The position switch (PSW) is used as an im aginary dog switch by assigning an axis name and coordinate values that indicate the imaginary dog position to be used instead of the dog switch on the machine axis. When the machine reaches the imagi nary dog po[...]

  • Page 291

    12. Position Sw itch 12.1 Outline of Function 285 Position switch numbers of PSW1 to PSW16 and signal devices <axis> <dog1> <dog2> 1st part system 2nd part system 3rd part system 4th part system 5th part system 6th part system 7th part system PSW1 7501 7502 7503 X660 X6E0 X760 X7E0 X860 X8E0 X960 PSW2 7511 7512 7513 X661 X6E1 X761[...]

  • Page 292

    12. Position Sw itch 12.2 Canceling the Position Sw itch 286 Rotary axis Setting of dog1 and dog2 Operation Description dog1 < dog2 A signal is output between dog1 and dog2. A signal is also output when dog1 is negative. dog1 > dog2 A signal is output between dog2 and dog1. ⏐ dog1 − dog2 ⏐ ≥ 360 A signal is kept output when the differ[...]

  • Page 293

    13. Indexing Axis Parameters 287 13. Indexing Axis Parameters (Note) These parameters are used only with the G64T. # Item Details Setting range (unit) 26251 METHOD Select the index command method. 0: Matrix command 1: Single command 2: BCD command (without parity) 3: BCD command (with parity) 0/1/2/3 26252 AUX bit0 Select the rotary axis' cont[...]

  • Page 294

    13. Indexing Axis Parameters 288 # Item Details Setting range (unit) 26256 CURRENT LIMIT Set current limit value when current limit value command signal is ON. 0 to 100 (%) 26257 OFFSET Set the indexing position compensation amount. -999.999 to 999.999 (mm) 26258 OFFSET LIMIT If the indexing position compensation amount exceeds this value, the &quo[...]

  • Page 295

    14. Indexing Axis Position Sw itch 14.1 Outline of Function 289 14. Indexing Axis Position Switch 14.1 Outline of Function (Note) These parameters are used only with the G64T. The position switch (PSW) is used as an im aginary dog switch by assigning an axis name and coordinate values that indicate the imaginary dog position to be used instead of t[...]

  • Page 296

    15. Indexing Axis Commands 290 15. Indexing Axis Commands (Note) These parameters are used only with the G64T. Item Details Setting range (unit) POSITION Command the i ndexing position. –99999.999 to 99999.999 (0.001mm/0.001°, 0.0001mm/0.0001°) SPEED Set the indexing speed. 0 to 999999 (mm/min, °/min) INPOS Set the in-position width, which ind[...]

  • Page 297

    16. Auxiliary Axis Parameters 291 16. Auxiliary Axis Parameters Turn the NC power OFF after setting parameters indica ted with a (PR) in the table. The setting will be validated after the power is turned ON again. No. Name Details Setting range Default valu e 1 (PR) MSR Motor series Set the motor series. This is automatically judged by the system w[...]

  • Page 298

    16. Auxiliary Axis Parameters 292 No. Name Details Setting range Default valu e 7 ATU Auto-tuning Set the adjustment of the auto-t uning. Do not set values without a description. 0 1 0 2 (Default setting value) Setting value Details 1 Low response (low-rigidity loads, loads which easily vibrate) 2 Standard setting value 3 Standard setting value 4 S[...]

  • Page 299

    16. Auxiliary Axis Parameters 293 No. Name Details Setting range Default valu e 14 NCH Notch filter No. Set the frequency of the machine resonance suppression filter. Do not set values without a description. Setting value 0 1 2 3 4 5 6 7 Frequency (Hz) No start 1125 563 375 282 225 188 161 15 (Not used.) 0 16 JIT Jitter compensation Set the No. of [...]

  • Page 300

    16. Auxiliary Axis Parameters 294 No. Name Details Setting range Default valu e 50 MD1 D/A output channel 1 data No. Set the Nos. of the data to be output on D/A output channel 1. 0 0 0 0 (Default setting value) Setting value Details Magnification 0 Speed feedback (with sign) Maximum rotation speed = 8V 1 Current feedback (with sign) Maximum curren[...]

  • Page 301

    16. Auxiliary Axis Parameters 295 No. Name Details Setting range Default valu e 101 (PR) Cont1 Control parameter 1 This is a HEX setting parameter. Set bits without a description to their default values. bit F E D C B A 9 8 7 6 5 4 3 2 1 0 Default value 000000100 0 0 0 0 000 bit Meaning when "0" is set Meaning when "1" is set 0 [...]

  • Page 302

    16. Auxiliary Axis Parameters 296 No. Name Details Setting range Default valu e 102 (PR) Cont2 Control parameter 2 This is a HEX setting parameter. Set bits without a description to their default values. bit F E D C B A 9 8 7 6 5 4 3 2 1 0 Default value 000000001 0 0 0 0110 bit Meaning when "0" is set Meaning when "1" is set 0 1[...]

  • Page 303

    16. Auxiliary Axis Parameters 297 No. Name Details Setting range Default valu e 104 (PR) tleng Linear axis stroke length Set the movement stroke length for linear axes. This is meaningless when setting non-uniform assignments or commanding random positions. 0.001 to 99999.999 (mm) 100.000 110 ZRNspeed Reference point return speed Set the clamp valu[...]

  • Page 304

    16. Auxiliary Axis Parameters 298 No. Name Details Setting range Default valu e 120 ABS Type Absolute position detection parameter This parameter is set as a hexadecimal. Set the default value for bits that have no description. bit F E D C B A 9 8 7 6 5 4 3 2 1 0 Default value 0000000000 0 0 0 100 bit Meaning when "0" is set Meaning when [...]

  • Page 305

    16. Auxiliary Axis Parameters 299 < Operation parameter group 1 > No. Name Details Setting range Default valu e 150 Aspeed1 Operation parameter group 1 Automatic operation speed Set the feedrate during automatic operation when operation parameter group 1 is selected. This parameter is regarded as the clamp value for the automatic operation sp[...]

  • Page 306

    16. Auxiliary Axis Parameters 300 No. Name Details Setting range Default valu e 154 TL1 Operation parameter group 1 Torque limit value Set the motor output torque limit value when operation parameter group 1 is selected. At the default value, the torque is limited at the maximum torque of the motor specifications. Set the default value when torque [...]

  • Page 307

    16. Auxiliary Axis Parameters 301 < Operation parameter group 2 > No. Name Details Setting range Default valu e 158 Aspeed2 Operation parameter group 2 Automatic operation speed Set the feedrate during automatic operation when operation parameter group 2 is selected. 1 to 100000 (°/min or mm/min) 5000 159 Mspeed2 Operation parameter group 2 [...]

  • Page 308

    16. Auxiliary Axis Parameters 302 No. Name Details Setting range Default valu e 162 TL2 Operation parameter group 2 Torque limit value Set the motor output torque limit value when operation parameter group 2 is selected. At the default value, the torque is limited at the maximum torque of the motor specifications. Set the default value when torque [...]

  • Page 309

    16. Auxiliary Axis Parameters 303 < Operation parameter group 3 > No. Name Details Setting range Default valu e 166 Aspeed3 Operation parameter group 3 Automatic operation speed Set the feedrate during automatic operation when operation parameter group 3 is selected. 1 to 100000 (°/min or mm/min) 5000 167 Mspeed3 Operation parameter group 3 [...]

  • Page 310

    16. Auxiliary Axis Parameters 304 No. Name Details Setting range Default valu e 170 TL3 Operation parameter group 3 Torque limit value Set the motor output torque limit value when operation parameter group 3 is selected. At the default value, the torque is limited at the maximum torque of the motor specifications. Set the default value when torque [...]

  • Page 311

    16. Auxiliary Axis Parameters 305 < Operation parameter group 4 > No. Name Details Setting range Default valu e 174 Aspeed4 Operation parameter group 4 Automatic operation speed Set the feedrate during automatic operation when operation parameter group 4 is selected. 1 to 100000 (°/min or mm/min) 5000 175 Mspeed4 Operation parameter group 4 [...]

  • Page 312

    16. Auxiliary Axis Parameters 306 No. Name Details Setting range Default valu e 178 TL4 Operation parameter group 4 Torque limit value Set the motor output torque limit value when operation parameter group 4 is selected. At the default value, the torque is limited at the maximum torque of the motor specifications. Set the default value when torque [...]

  • Page 313

    16. Auxiliary Axis Parameters 307 No. Name Details Setting range Default valu e 190 stpos2 Station 2 coordinate value 191 stpos3 Station 3 coordinate value 192 stpos4 Station 4 coordinate value 193 stpos5 Station 5 coordinate value 194 stpos6 Station 6 coordinate value 195 stpos7 Station 7 coordinate value 196 stpos8 Station 8 coordinate value 197 [...]

  • Page 314

    16. Auxiliary Axis Parameters 308 No. Name Details Setting range Default valu e 201 202 PSW1dog1 PSW1dog2 PSW1 area setting 1 PSW1 area setting 2 203 204 PSW2dog1 PSW2dog2 PSW2 area setting 1 PSW2 area setting 2 205 206 PSW3dog1 PSW3dog2 PSW3 area setting 1 PSW3 area setting 2 207 208 PSW4dog1 PSW4dog2 PSW4 area setting 1 PSW4 area setting 2 209 21[...]

  • Page 315

    Revision History Date of revision Manual No. Revision details Dec. 2000 BNP-B2267* First edition created. Sep. 2003 BNP-B2267A • The cover (front, spine, back covers) design was changed. • "Type", "Independent Product Code" and "Reference No." were added to the back cover. • The following parameters were added. ([...]

  • Page 316

    Notice Every effort has been made to keep up with software and hardware revisions in the contents described in this manual. However, please understand that in some unavoidable cases simultaneous revision is not possible. Please contact your Mitsubishi Electric dealer with any questions or comments regarding the use of this product. Duplication Proh[...]

  • Page 317

    BNP-B2267C(ENG) MC6/C64/C64T 008-046 (0403) MEE Specifications subject to change without notice. Printed in Japan on recycled paper. MODEL Manual No. MODEL CODE MITSUBISHI ELEC T R IC CO R PO R A T ION HEAD OFFICE : MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN[...]