Mitsubishi Electronics FR-A800 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 14 pages
- 0.27 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Router
Mitsubishi Electronics E70
214 pages 12.75 mb -
Projector
Mitsubishi Electronics XD450U
34 pages 3.56 mb -
Flat Panel Television
Mitsubishi Electronics WD-57833
96 pages 5.83 mb -
Life Jacket
Mitsubishi Electronics MDS-B
188 pages 2.11 mb -
Refrigerator
Mitsubishi Electronics MR-385R-ST-A
32 pages 1.05 mb -
Projection Television
Mitsubishi Electronics WS-55311
79 pages 4.39 mb -
Universal Remote
Mitsubishi Electronics LY10R2
102 pages 5.44 mb -
Home Security System
Mitsubishi Electronics Q172CPU(N)
472 pages 4.22 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Mitsubishi Electronics FR-A800. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Mitsubishi Electronics FR-A800 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Mitsubishi Electronics FR-A800 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Mitsubishi Electronics FR-A800 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Mitsubishi Electronics FR-A800
- nom du fabricant et année de fabrication Mitsubishi Electronics FR-A800
- instructions d'utilisation, de réglage et d’entretien de l'équipement Mitsubishi Electronics FR-A800
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Mitsubishi Electronics FR-A800 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Mitsubishi Electronics FR-A800 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Mitsubishi Electronics en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Mitsubishi Electronics FR-A800, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Mitsubishi Electronics FR-A800, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Mitsubishi Electronics FR-A800. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
INVERTER FR-A800/F800 Safety S top Function Instruction Manual CONTENTS 1. GENERAL DESCRIPTION .. .......................................... 2 2. INSTALLATION AND WIRING ...................................... 3 3. EXAMPLE OF SAFETY SYSTEM CONFIGURATION .... 7 4. TEST AND CHECKING FAILURE ............................... 10 5. SAFETY PARAMETERS OF FR[...]
-
Page 2
1 Compliance with the EU Machin ery Directive – Functional Safety WA R N I N G Any misuse of saf ety function could lead to per sonal injury or death, proper ty damage, or economic loss. T o ensure that the system complies fully with requirement of safety , make a system-level risk assessment. Mit subishi Electric Co. cannot assume responsibi[...]
-
Page 3
2 GENERAL DESCRIP TION 1 GENERAL DESCRIPTION Features Mitsubishi FR-A800/F800 safety stop function prevents a dr ive fr om supplying rotatio nal energy to motor s. Dual safety channels ‘S1’ and ‘S2’ cut o ff th e gate-drive powe r for IGBT to turn off. Fig.1 FR-A800 /F800 safety stop functio n diagram Standards Mitsubishi FR-A800/F800 safet[...]
-
Page 4
INSTALLATION AND WIRING 3 2 INST ALLA TION AND WIRING Installation Mitsubishi FR-A800/F8 00 safety stop function shoul d be used under following cond ition and environment. T able.1 The condition and envir onment for using safety stop functi on The ND and HD ratings can be selecte d only for the FR-A800. T emperature applicable for a [...]
-
Page 5
4 INSTALLATION AND WIRING ● Wiring The safety related terminals are de scribed in T a ble.2 and T abl e.3 T able.2 The safety relate d terminals S pecifications for conforming safety standards. ON: The transistor is conducted. OF F: The transistor is not conducted. CAUTION In order to meet safety stop, an approved safety relay u[...]
-
Page 6
INSTALLATION AND WIRING 5 T able.3 T ruth t able of safety relat ed signals ON: The transistor is conducted. OFF: The transistor is not conducted. When not using the safety stop function, short across terminals S1 and PC, S2 and PC, a nd SIC and SD to use the inverter . (In the initial status, terminals S1 and PC, S2 and PC, and SIC a[...]
-
Page 7
6 INSTALLATION AND WIRING ● Wire and ferrule specification T able.4 Wire and ferrule spec ification Ferrules and tools are distributed by Phoenix Contact. ● Jumper cable The jumper cable between S1,S2 and PC termin al between SIC and SD terminal has been inst alled in the factory as shown in Fig.2. Fig.2. Short wire Before conne cting sa[...]
-
Page 8
EXAMPLE OF SAFETY SYSTEM CONFIGURATION 7 3 EXAMPLE OF SAFETY SY STEM CONFIGURA TION ● FR-A800/F800 configuration exa mple If the control logic is SINK logic, the common terminal is terminal SD. Fig.3 Safety system example with FR- A800/F800 NOTE • When starting up the system’ s operation, press the RESET switch to reset the safety stop[...]
-
Page 9
8 EXAMPLE OF SAFETY SYSTEM CONFIGURATION ● Multiple inverter configuration exam ple Fig.4 When using multiple safety stop func tion inverters (FR-A800/F800) NOTE • Some models cannot be used together because thei r control logics are different. Refer to the SAFETY STOP FUNCTION MANUAL of each model. S 1 S 2 PC FR-A800/F800 SO R/L1 S/L2 T/L3 IGB[...]
-
Page 10
EXAMPLE OF SAFETY SYSTEM CONFIGURATION 9 ● Safety controller configuration exa mple Fig.5 Safety system example with FR- A800/F800 NOTE • When starting up the system’ s operation, press the RESET switch to reset the safety stop function first. • In the above configuration, af ter reset of emergency stop button, drive will be in safe-state u[...]
-
Page 11
10 TEST AND CHECKING FAILURE 4 TEST AND CHECKING F AIL URE I/O status and failure FR-A800/F800 safety re lated I/O status obeys the following truth t able. T able.5 T ruth t able of safety related signals ON: The transistor is conducted. OF F: The transistor is not conducted. When not using the safety stop function, short across termi[...]
-
Page 12
SAFETY PARAMETERS OF FR-A800/F800 11 Diagnostic If the failure detected, FR-A800/F800 output ala rm signal and i ndicate ‘E.SAF’ at the display . In case of FR-A800/F800 output the alar m, please take following action. 1) Check the S1-SIC and S2-SIC input sign al logic is the same. If these are differe nt lo gic, collect the input signal and re[...]
-
Page 13
12 REVISIONS Print Date Manual Number Revision Apr . 2013 BCN-A23228-001(E) First edition Jun. 2013 BCN-A23228-001-A(E) ● Multiple inverter configuration example Jul. 2014 BCN-A23228-001-B(E) Compatibility with the FR-F800 series Modification BCN-A23228-001-B(E)[...]
-
Page 14
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAP AN MITSUBISHI ELECTRIC EUROP E EUROPE B.V . German Branch Gothaer S traße 8 D-40880 Ratingen Phone: +49 (0) 21 02 / 486-0 Hotline: +49 2102 1805 000-76 5 /-766 Fax: +49 (0) 21 02 / 4 86-1 12 0 e mail: megfa-ma il@meg.mee.com www .mitsubishi-automatio n.com MITSUBISHI EL[...]