Monessen Hearth CL)NVC/PVC manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 52 pages
- 6.43 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Indoor Fireplace
Monessen Hearth 624DVPF
1 pages 0.48 mb -
Indoor Fireplace
Monessen Hearth DBX24C
36 pages 3.35 mb -
Indoor Fireplace
Monessen Hearth 7000 Series
36 pages 0.45 mb -
Indoor Fireplace
Monessen Hearth BUF400
1 pages 0.45 mb -
Indoor Fireplace
Monessen Hearth GCUF36C-F
1 pages 0.44 mb -
Indoor Fireplace
Monessen Hearth Direct Vent Gas Insert IDV380NVC
40 pages 6.34 mb -
Indoor Fireplace
Monessen Hearth DFS32
4 pages 0.48 mb -
Indoor Fireplace
Monessen Hearth DFS42C
1 pages 0.44 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Monessen Hearth CL)NVC/PVC. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Monessen Hearth CL)NVC/PVC ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Monessen Hearth CL)NVC/PVC décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Monessen Hearth CL)NVC/PVC devrait contenir:
- informations sur les caractéristiques techniques du dispositif Monessen Hearth CL)NVC/PVC
- nom du fabricant et année de fabrication Monessen Hearth CL)NVC/PVC
- instructions d'utilisation, de réglage et d’entretien de l'équipement Monessen Hearth CL)NVC/PVC
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Monessen Hearth CL)NVC/PVC ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Monessen Hearth CL)NVC/PVC et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Monessen Hearth en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Monessen Hearth CL)NVC/PVC, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Monessen Hearth CL)NVC/PVC, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Monessen Hearth CL)NVC/PVC. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
?[...]
-
Page 2
2 42D0200 Designer Se r ies Gas F ireplaces [...]
-
Page 3
42D0200 Designer Se r ies Gas F ireplaces 3 4. Never install the fireplace • in a recreational vehicle • wh er e cu rta ins, fur ni tu re , cl ot hi ng, or oth er fla mm ab le objects are less than 42" from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas 5. Th is fi re pl ace rea ch es hi gh[...]
-
Page 4
4 42D0200 Designer Se r ies Gas F ireplaces 14. Do not use any solid fuels (wood, coal, paper , card- board, etc.) in this fireplace. Use only the gas type indicated on rating plate. 15. This appliance, whe[...]
-
Page 5
42D0200 Designer Se r ies Gas F ireplaces 5 • This appliance has been certified for use with either natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels. • The app lia nce[...]
-
Page 6
6 42D0200 Designer Se r ies Gas F ireplaces 23 6M ” 39 6 ” 18 (6 ” 4 (6QE ” 2 (6QE ” 44” 34 56O ” 40 56QE ” 5/8” 1/2” 32 6M ” C L 5/8” 1/2” 420200 6000Dv penin dims Gas/Electric Access [...]
-
Page 7
42D0200 Designer Se r ies Gas F ireplaces 7 It is best to build firebox framing the appliance is set in place. Refer to the dimensions for your fireplace on Page 7. The framing headers may rest on the top of the firebox standof fs. The firebox may be installed directly on a combustible floor or raised on a platform of an appropri[...]
-
Page 8
8 42D0200 Designer Se r ies Gas F ireplaces For ease of installation, frame around the firebox after it has been set. Refer to chart below for specifications. Whe n ins ta lli ng[...]
-
Page 9
42D0200 Designer Se r ies Gas F ireplaces 9 The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considere d[...]
-
Page 10
10 42D0200 Designer Se r ies Gas F ireplaces This gas fireplace should be installed by a qualified installer in accordance with local building codes and with current CSA-B149 (.1 or .2) Installation codes for Gas Burning Fireplaces and Equipment. If the unit is being[...]
-
Page 11
42D0200 Designer Se r ies Gas F ireplaces 1 1 Minimum distance between a glass panel and a parallel wall = 42" Minimum distance between the edge of a glass panel and an adjacent wall = 3" (Maximum length of horizontal ve[...]
-
Page 12
12 42D0200 Designer Se r ies Gas F ireplaces The appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent config[...]
-
Page 13
42D0200 Designer Se r ies Gas F ireplaces 13 This appliance must be installed with a Monessen approved venting system only . Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for inst[...]
-
Page 14
14 42D0200 Designer Se r ies Gas F ireplaces There are two basic types of direct-vent installation: • Horizontal T ermination • V ertical T ermination It is important to select the proper length of vent pipe for[...]
-
Page 15
42D0200 Designer Se r ies Gas F ireplaces 15 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Fixed Closed Operable Operable Fixed Closed V B CFM145a DV T ermin Location 5/01/01 Rev . 12/05/01 sta INSIDE CORN[...]
-
Page 16
16 42D0200 Designer Se r ies Gas F ireplaces [...]
-
Page 17
42D0200 Designer Se r ies Gas F ireplaces 17 When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance • The maximum horizontal distance between the rear of the appliance and the ou[...]
-
Page 18
18 42D0200 Designer Se r ies Gas F ireplaces 4. Apply a bead of non-hardening mastic around the outside edge of vent cap. Position the vent cap in the center of hole on the exterior wall with the word “UP” on the vent cap facing up. Insure proper clearance of 1" to combustib[...]
-
Page 19
42D0200 Designer Se r ies Gas F ireplaces 19 [...]
-
Page 20
20 42D0200 Designer Se r ies Gas F ireplaces • If a 90° elbow is used in the horizontal vent run, the horizontal vent length is reduced by 36" (914 mm). Figure 25. This does not apply if the 90° elbows are used to increase or redirect a vertical rise. Figure 25 According to the vent graph, Figure 22 , the maximum h[...]
-
Page 21
42D0200 Designer Se r ies Gas F ireplaces 21 When it is no t possible to mee t the required vent terminal clearances of 1 2 " above grade le vel, a snor kel kit is rec ommended. It allows inst allation[...]
-
Page 22
22 42D0200 Designer Se r ies Gas F ireplaces FP2308 suppor t straps This Gas Fireplace has been approved for , • V er tical installations up to 40 ' ( 1 2 m ) in height. Up to a 1 0' (3 m ) horizontal vent run can be i[...]
-
Page 23
42D0200 Designer Se r ies Gas F ireplaces 23 9 1 / 2 " 9 1 / 2 " FP1970 firestop no room 1. Determine the route your vertical venting will take. If ceiling [...]
-
Page 24
24 42D0200 Designer Se r ies Gas F ireplaces 4. Connect a section of pipe and extend up through the hole. [...]
-
Page 25
42D0200 Designer Se r ies Gas F ireplaces 25 Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for yo[...]
-
Page 26
26 42D0200 Designer Se r ies Gas F ireplaces : The gas line connection may be made using 1 / 2 " rigid tubing or an approved flex connector . Since some municipalities have additional local codes it is always best to consult your local authorities and the current edition of the National Fuel Gas Code ANSI.Z223.1, NFP A54. In Ca[...]
-
Page 27
42D0200 Designer Se r ies Gas F ireplaces 27 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is dif ferent from the fireplace, Do not install the appliance. Contact your dealer immediately . 2. T o ea se inst alla tio n, a 30" (7 62 mm) flex lin e wit h ma nu al[...]
-
Page 28
28 42D0200 Designer Se r ies Gas F ireplaces A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 38 . Do not extend beyond the wall switch [...]
-
Page 29
42D0200 Designer Se r ies Gas F ireplaces 29 Position the wall switch. Do not extend beyond the 15 feet of wire. ?[...]
-
Page 30
30 42D0200 Designer Se r ies Gas F ireplaces All three (3) glass frames are replaced the same way . 1. Release two clamps on bottom of fireplace. Figure 40 2. Tilt glass frame out and lift glass frame up until it clears three tabs on top of firepl[...]
-
Page 31
42D0200 Designer Se r ies Gas F ireplaces 31 1. Remove glass frame. Refer to Glass Frame Removal, Page 31. 2. Carefully remove logs from wrappin[...]
-
Page 32
32 42D0200 Designer Se r ies Gas F ireplaces L G640 DV6000 bot ctr back lo g Figure 43 - Install Bottom Center Log (#3) Bottom Center Back Log (#3) Pin LG640 L G642 DV6000 left top log 5. Position left end of bottom center back log (#3) beside rear end of left log (#1). Line up pin on grate with pin hole in bottom of center back log (#3) Snug right[...]
-
Page 33
42D0200 Designer Se r ies Gas F ireplaces 33 L G644 DV6000 rockwool Figure 47 - Rock Wool Placement (Right Corner Model Shown) 8. Place Y -Shape d end of top log (#6) on on pro ng four of bac k of gr ate . Pos it ion othe r end of top log (#6) in cutout of bottom center log (#3). Figure 46 Rock Wool L643 D[...]
-
Page 34
34 42D0200 Designer Se r ies Gas F ireplaces The fireplace is equipped with a restrictor plate that is located inside the top chamber of the fireplace. Depending upon the vent configuration, you may be required to adjust the restrictor position 1. Remove glass frame. Re[...]
-
Page 35
42D0200 Designer Se r ies Gas F ireplaces 35 This appliance is equipped with a pilot which must be lit with built-in battery ignitor while following these instructions exactly . BEFORE OPERA TING smell all around the appliance area for gas. Be sure to smell next[...]
-
Page 36
36 42D0200 Designer Se r ies Gas F ireplaces PILOT O F F P I L O T O N FP1935 control knob pilot Continued on next page Y ou may check for gas leaks with the following methods only: • Soap and[...]
-
Page 37
42D0200 Designer Se r ies Gas F ireplaces 37 PILOT O F F P I L O T O N O F F P I L O T O N PILOT FP1937 control knob on Figure 51 - On Position PILOT O F F P I L O T O N FP1935 control knob pilot Figure 50 - On/Off/RS Switch OFF ON RS ?[...]
-
Page 38
38 42D0200 Designer Se r ies Gas F ireplaces Make sure the gas valve knob is in the “OFF” position. Wait at least five (5) minutes before start- ing maintenance. Fireplace must be cold before starting maintenance. A qualified age[...]
-
Page 39
42D0200 Designer Se r ies Gas F ireplaces 39 1. Spark ignitor will not light pilot after repeated triggering of piezo. 2. Pilot will not sta[...]
-
Page 40
40 42D0200 Designer Se r ies Gas F ireplaces 1. Turn gas supply of f. 2. Turn ON/OFF switch to “ON” Power to module (24V Normal) Is there a spark across ignitor sensor gap? T urn on gas. Does pilot [...]
-
Page 41
42D0200 Designer Se r ies Gas F ireplaces 41 and • Never operate fireplace if glass is broken. • Replace any glass that is chipped, cracked, or bro[...]
-
Page 42
42 42D0200 Designer Se r ies Gas F ireplaces [...]
-
Page 43
42D0200 Designer Se r ies Gas F ireplaces 43 REPLACEMENT P ARTS ARE A V AILABLE THROUGH YOUR RET AILER [...]
-
Page 44
44 42D0200 Designer Se r ies Gas F ireplaces 1 2C 2I 2T 2 4 5 6 3 7 8 9 , 1 0 , 1 1,12 420200 DV6000 millivolt parts ?[...]
-
Page 45
42D0200 Designer Se r ies Gas F ireplaces 45 1 3 4 5 7 8 9 LO HI 2 24V #6 24V GND #5 PV #3 MV/PV #2 MV #1 GND (BURNER) #4 SENSE #8 SP ARK #9 420200 DV6000 elect par ts 6 [...]
-
Page 46
46 42D0200 Designer Se r ies Gas F ireplaces HOT 1 2 3 4 5 6 9 7 8 1 1 10 420200 DV6000 vent components Simpson Durvent Ref. Qty/Box Description or MHSC Pt. No. 1. 1 Simpson Horizontal High Wind T ermination 985 Horizontal Square T ermination[...]
-
Page 47
42D0200 Designer Se r ies Gas F ireplaces 47[...]
-
Page 48
48 42D0200 Designer Se r ies Gas F ireplaces[...]
-
Page 49
42D0200 Designer Se r ies Gas F ireplaces 49[...]
-
Page 50
50 42D0200 Designer Se r ies Gas F ireplaces This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. Any residence with a direct vent product must have a CO detector installed in the residenc[...]
-
Page 51
42D0200 Designer Se r ies Gas F ireplaces 51 The following components are warranted for life to the original owner , subject to proof of purchase: Firebox, Combustion Chamber , Heat Exchanger , Grate[...]
-
Page 52
149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com 624DVSTNVC 62.8 624DVPFNVC 62.8 624DVCRNVC 62.8 624DVCLNVC 62.8 624[...]