National Instruments NI PXI/PCI-5114 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 20 pages
- 0.21 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Computer Hardware
National Instruments Serial Hardware and Software for Windows User Manual
208 pages 2.23 mb -
Computer Hardware
National Instruments 3.21E+04
181 pages 0.59 mb -
Computer Hardware
National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device
18 pages 0.58 mb -
Computer Hardware
National Instruments 321372C-01
50 pages 0.39 mb -
Computer Hardware
National Instruments NI 5401
60 pages 0.5 mb -
Computer Hardware
National Instruments HPC467064
34 pages 0.4 mb -
Computer Hardware
National Instruments NI USB-9421
18 pages 0.58 mb -
Computer Hardware
National Instruments HPC167064
34 pages 0.4 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation National Instruments NI PXI/PCI-5114. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel National Instruments NI PXI/PCI-5114 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation National Instruments NI PXI/PCI-5114 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation National Instruments NI PXI/PCI-5114 devrait contenir:
- informations sur les caractéristiques techniques du dispositif National Instruments NI PXI/PCI-5114
- nom du fabricant et année de fabrication National Instruments NI PXI/PCI-5114
- instructions d'utilisation, de réglage et d’entretien de l'équipement National Instruments NI PXI/PCI-5114
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage National Instruments NI PXI/PCI-5114 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles National Instruments NI PXI/PCI-5114 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service National Instruments en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées National Instruments NI PXI/PCI-5114, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif National Instruments NI PXI/PCI-5114, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation National Instruments NI PXI/PCI-5114. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
NI PXI/PCI-5114 Specifications 8-Bit 250 MS/s Digitizer Unless otherwise noted, the followi ng conditions were used for each specification: • All filter settings • All impedance selections • Sample clock set to 250 MS/s T ypical values are representati ve of an av erage unit operating at room temperature. Specifications are subject to change [...]
-
Page 2
NI PXI/PCI-5114 Specifications 2 ni.com Power .............. .................... ................ .................... .................... .............14 Software .................. .................... .................... .................... ................... .. 15 Environment .............. .................... .................... .......[...]
-
Page 3
© National Instruments Corporat ion 3 NI PXI/PCI-5 114 Specifications Voltage Levels Full Scale (FS) Input Range and Programmable V ertical Of fset 50 Ω 1 M Ω — Range (V pk-pk ) V ertical Of fset Range (V) Range (V pk-pk ) V ertical Offset Range (V) 0.04 ±0.8 0.04 ±0.8 0.1 ±0.8 0.1 ±0.8 0.2 ±0.8 0.2 ±0.8 0.4 ±0.8 0.4 ±0.8 1 ±6.5 1.0 ?[...]
-
Page 4
NI PXI/PCI-5114 Specifications 4 ni.com Figure 1. NI 5114 Frequency Response (T ypical) Bandwidth and Transient Response Bandwidth (–3 dB) Range (V pk-pk ) Bandwidth Rise/F all T ime, T ypical — All ranges except 0.04 125 MHz 2.8 ns 0.04 100 MHz 3.5 ns Bandwidth Limit Filter 20 MHz Noise Filter — A C Coupling * Cutof f (–3 dB), T ypical 12 [...]
-
Page 5
© National Instruments Corporat ion 5 NI PXI/PCI-5 114 Specifications Specif ication Va l u e Commen ts Spectral Characteristics Spurious Free Dynamic Range with Harmonics (SFDR), T ypical Range (V pk-pk ) 10 MHz, –1 dBFS input signal. Includes the 2 nd through the 5 th harmonics. Measured from DC to 125 MHz. 20 MHz bandwidth limit filter of f. [...]
-
Page 6
NI PXI/PCI-5114 Specifications 6 ni.com Horizontal Sample Clock Specification Va l u e Comments Sources Internal, Onboard Clock (i nternal VCXO)* External, CLK IN (front panel SMB connector) * Internal Sample Clock is locked to the Reference Clock or deri ved from the onboard VCXO. Onboard Clock (Internal VCXO) Sample Rate Range Real-T ime Sampling[...]
-
Page 7
© National Instruments Corporat ion 7 NI PXI/PCI-5 114 Specifications Phase-Locked Loo p (PLL) Reference Clock External Sample Clock Sources CLK IN (front panel SMB connector) — Frequenc y Range 50 MHz to 250 MHz Di vide by n decimation av ailable where 1 ≤ n ≤ 65,535. For more informati on about Sample Clock and decimation, refer to the NI [...]
-
Page 8
NI PXI/PCI-5114 Specifications 8 ni.com CLK IN (Sample Clock and Reference Clock Input, Front Panel Connector) T r igger Reference (Stop) T rigger Specification Va l u e Comments Input V oltage Range Sine wav e: 0.65 V pk-pk to 2.8 V pk-pk (0 dBm to 13 dBm) Square wav e: 0.2 V pk-pk to 2 .8 V pk-pk — Maximum Input Overload 7 V rms with | Peaks | [...]
-
Page 9
© National Instruments Corporat ion 9 NI PXI/PCI-5 114 Specifications Analog Trigger (Edge, Window, and Hysteresis Trigger Types) Sources CH 0 (front panel BNC connector) CH 1 (front panel BNC connector) TRIG (front panel BNC connector) — T rigger Level Resolution 8 bits (1 in 256) T rigger Level Range CH 0, CH 1 TRIG (External Trigger) — 100%[...]
-
Page 10
NI PXI/PCI-5114 Specifications 10 ni.com TRIG (External T rigger , Front Panel Connector) PFI 0 and PFI 1 (Programmable Function Interface, AUX Front Panel Connectors) T ypes Specific Line Any Line Specific Field — Standards SDTV : M-NTSC, B/G-P AL, SECAM, M-P AL EDTV : 480i/59.94 fps, 480i /60 fps, 480p/59.94 Fps, 480p/60 Fps, 576i/50 fps, 576p/[...]
-
Page 11
© National Instruments Corporat ion 11 NI PXI/PCI-5 114 Specifications As an Input (Trigger) Destinations Start T rigger (Acquisition Arm) Reference (Stop) T rigger Arm Referen ce Advance T rigger — Input Impedance 150 k Ω — V IH 2.0 V — V IL 0.8 V — Maximum Input Overload –0.5 V to 5.5 V — Maximum Frequency 25 MHz — As an Output (E[...]
-
Page 12
NI PXI/PCI-5114 Specifications 12 ni.com TClk Specifications National Instruments TClk synchronizati on method and the NI-TClk driver are used to align the sample clocks on any number o f SMC-based modules in a chassis. For more inform ation about TClk synchronizati on, refer to the NI-TClk Synchronization Help , wh ich is located within the N I Hi[...]
-
Page 13
© National Instruments Corporat ion 13 NI PXI/PCI-5 114 Specifications W aveform Specifications Specif ication Va l u e Comments Onboard Memory Size 8 MB per Channel Standard 8 megasamples per channel — 64 MB per Channel Option 64 megasamples per channel 256 MB per Channel Option 256 megasamples per channel Minimum Record Length 1 Sample — Num[...]
-
Page 14
NI PXI/PCI-5114 Specifications 14 ni.com Calibration Power Specification Va l u e Comments Self-Calibrati on Self-calibration i s done on soft ware command. The calibration corrects for gain, of fset, compensated 1 M Ω attenuat or , triggering, and timing adjustment errors fo r all input ranges. — External Calibration (Factory Calibration) The e[...]
-
Page 15
© National Instruments Corporat ion 15 NI PXI/PCI-5 114 Specifications Software Specification Va l u e Comm ents Dri ver Software NI PXI-5114 : NI-SCOPE 2.9 or later . NI PCI-5114 : NI-SCOPE 3.1 or later . NI-SCOPE is an IVI-complian t dri ver that allo ws you to configure, control, and calib rate the NI 5114. NI-SCOPE provides application program[...]
-
Page 16
NI PXI/PCI-5114 Specifications 16 ni.com Environment NI PXI-5114 Note T o ensure that the NI PXI-5114 cools ef fectiv ely , follow the guidelines in the Maintain Forced Air Cooling Note to Users included in the NI PXI-5114 kit. The NI PXI-5114 is intended for indoor use only . Specif ication Va l u e Comments Operating T emperature 0 ºC to +55 ºC[...]
-
Page 17
© National Instruments Corporat ion 17 NI PXI/PCI-5 114 Specifications NI PCI-5114 Note T o ensure that the NI PCI-5114 cools ef fectiv ely , follo w the guidelines in the Maintain Forced Air Cooling Note to Users included in the NI PCI-5114 kit. Also , to maximize airflo w and extend the life of the de vice, leave an y adjacent PCI slots empty . [...]
-
Page 18
NI PXI/PCI-5114 Specifications 18 ni.com Safety , Electromagnetic Compatibility , and CE Compliance Specification Va l u e Comm ents Safety The NI 5114 meets the requirements of the following standards of safety for electri cal equipment for measurement, control, and laboratory use: • IEC 61010 -1, EN 6101 0-1 • UL 61010-1, CAN/CSA-C22.2 No. 61[...]
-
Page 19
© National Instruments Corporat ion 19 NI PXI/PCI-5 114 Specifications Physical Specification Va l u e Comments Dimensions NI PXI-5114 NI PCI-5114 — 3U, One slot, PXI/cPCI Module 21.6 × 2.0 × 13.0 cm (8.5 × 0.8 × 5.1 in.) 35.5 × 2.0 × 11.3 cm (13.4 × 0.8 × 4.4 in.) We i g h t 455 g (16 oz) 421 g (1 4.8 oz) — Front Panel Connectors Labe[...]
-
Page 20
National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for more inform ation about Natio nal Instruments trademarks. Other product and company names mentioned herein are trademarks or trad e names of their respective companies. For patents covering Nation[...]