Omega Vehicle Security HH508 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 20 pages
- 0.21 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Thermometer
Omega Vehicle Security HH65
2 pages 0.14 mb -
Thermometer
Omega Vehicle Security HH501BT
12 pages 0.17 mb -
Thermometer
Omega Vehicle Security HH507
15 pages 0.18 mb -
Thermometer
Omega Vehicle Security HH2100 Series
1 pages 0.46 mb -
Thermometer
Omega Vehicle Security OS520
2 pages 0.31 mb -
Thermometer
Omega Vehicle Security HHLM-2
13 pages 0.18 mb -
Thermometer
Omega Vehicle Security OS642F
16 pages 0.2 mb -
Thermometer
Omega Vehicle Security HH804W
3 pages 0.37 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Omega Vehicle Security HH508. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Omega Vehicle Security HH508 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Omega Vehicle Security HH508 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Omega Vehicle Security HH508 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Omega Vehicle Security HH508
- nom du fabricant et année de fabrication Omega Vehicle Security HH508
- instructions d'utilisation, de réglage et d’entretien de l'équipement Omega Vehicle Security HH508
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Omega Vehicle Security HH508 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Omega Vehicle Security HH508 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Omega Vehicle Security en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Omega Vehicle Security HH508, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Omega Vehicle Security HH508, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Omega Vehicle Security HH508. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
OMEGA HH508/HH509/HH509R Digital Thermometer[...]
-
Page 2
OMEGAnet SM On-Line Service http://www.omega.com Internet e-mail info@omega.com Servicing Nor th America: USA: ISO 9001 Certified Canada: One Omega Drive, Box 4047 976 Bergar Stamford, CT 06907-0047 Laval (Quebec) H7L5A1 Tel: (203) 359-1660 Tel: (514) 856-6928 FAX: (203)359-7700 FAX: (514) 856-6886 e-mail: info@omega.com e-mail: info@omega.com omeg[...]
-
Page 3
1 The symbol on the instrument indicates that the operator must refer to an explanation in this manual. WARNING To avoid electrical shock, do not use this instrument when working voltages at the measurement surface over 24V AC or DC. WARNING To avoid damage or burns, do not make temperature measurement in microwave ovens. CAUTION Repeated sharp fle[...]
-
Page 4
2 SPECIFICATIONS ENVIRONMENTAL Ambient Operating Ranges: 0°C to 50°C (32°F to 122°F) <80% R.H. Storage Temperature: -20°C to 60°C (-4°F to 140°F) <70% R.H. GENERAL Display: 3½ digit liquid crystal display (LCD) with a maximum reading of 1999. Polarity: Automatic, positive implied, negative polarity indication. Overrange: -OL is displ[...]
-
Page 5
3 ELECTRICAL Temperature Scale: Celsius or Fahrenheit user-selectable. Measurement Range: Thermocouple Range K-TYPE(0.1°C) -200°C to 1372°C, -328°F to 1999°F J-TYPE(0.1°C) -210°C to 1200°C, -346°F to 1999°F T-TYPE(0.1°C) -200°C to 400°C, -328°F to 752°F E-TYPE(0.1°C) -220°C to 1000°C, -364°F to 1832°F S-TYPE(1°C) 0°C to 1767°[...]
-
Page 6
4 OPERATING INSTRUCTIONS Power Switch The key turns the thermometer on or off. In the MIN MAX record mode can not power off, must leave MIN MAX record mode then power off. °C °F Selecting the Temperature Scale Readings is displayed in either degrees Celsius(°C) or degrees Fahrenheit(°F). When the thermometer is turned on, it is set to the tempe[...]
-
Page 7
5 MIN MAX record Mode Press MIN MAX key to enter the MIN MAX Recording mode, (displays the Maximum reading, Minimum reading, "MAX-MIN" reading and Average reading stored in record mode). In the this mode the automatic power-off feature is disabled and key and all function key are disabled. The beeper emits a tone when a new minimum or max[...]
-
Page 8
6 TIMER STOP-WATCH Mode (for HH501AR / HH501AS) Press TIMER STOP-W key to enter stop-watch mode stop-watch is displayed. Press START/STOP key to toggle stop-watch starts and stops (Time goes up to 19 minutes & 59.9 seconds). Press CLEAR key to display 0.1 second, then press again to zero the stop-watch. Press TIMER STOP-W key again to exit the [...]
-
Page 9
7 SET mode (Relative value set and Hi/Lo Limits value set) 1. Press SET key to enter Relative valuse SET mode (Press ENTER key can escape relative valuse set mode), REL set mode. _ = = =.= is displayed (the ".=" is displayed when you set up the fourth umber). Relative value is entered via overlay numbers, when you want to get negative val[...]
-
Page 10
8 Hi/Lo LIMITS mode Press Hi/Lo LIMITS key to enter the Hi/Lo Limits comparative mode, "LIMIT" is displayed. In the this mode the automatic power-off feature is disabled and other funtion key are disabled, when input temperature value exceed Hi. The beeper emits a continuity pulse tone and "Hi" is displayed, and when input tempe[...]
-
Page 11
9 OPERATOR MAINTENANCE WARNING To avoid possible electrical shock, disconnect the thermocouple connectors from the thermometer before removing the cover. Battery Replacement Power is supplied by a 9 volt "transistor" battery. (NEDA 1604, IEC 6F22). The " " appears on the LCD display when replacement is needed. To replace the bat[...]
-
Page 12
10 RS-232 Operation Using Quick BASIC The following example shows how to send command instruction and receive data responses over the RS-232 interface using Quick BASIC. The program example is set up on "COM1". CLS E$ = "A" ST1: CLOSE #1 OPEN "COM1:1200,E,7,1,DS,RS" FOR OUTPUT AS #1 PRINT #1, E$; CLOSE #1 OPEN "CO[...]
-
Page 13
11 IF C$ = "-" THEN DEC = DEC * -1 END IF B$ = MID$(A$, 10, 6) DEC1 = 0 N = 6 FOR I = 0 TO 5 C$ = MID$(B$, N, 1) N = N - 1 D = INSTR(F$, C$) - 1 DEC1 = DEC1 + (16 ^ I) * D NEXT DEC1 = DEC1 / 1000 C$ = MID$(A$, 9, 1) IF C$ = " - " THEN DEC1 = DEC1 * -1 END IF CLS LOCATE 12, 33 PRINT " T1 T2" LOCATE 13, 30 PRINT USING &q[...]
-
Page 14
12 RS-232 Transmit and Receive Comammand Summary 1. Control letter should use Capital Letter. Baud rate: 1200 Parity check: EVEN Data bits: 7 Stop bits: 1 "A" Activate data transmission "B" Stop data transmission "C" °C/°F Key "D" " " Key "E" HOLD Key "F" TYPE Key "G"[...]
-
Page 15
13 08 — Thermocouple Type "K" ® K type "J" ® J type "T" ® T type "E" ® E type "S" ® S type OUTPUT DATA FORMATS The data format consists of 32 bytes. byte 000000000111 1111 123456789012 3456 SHHH HHHA SHHHH HH A T1 pr esent s tatus T2 pr esent s tatus S: Negative sign or positive sign H: Hexad[...]
-
Page 16
14 16 — none — " - " 17 — MSD 18 — LSD 19 — MSD 20 — LSD 21 — MSD 22 — LSD (H)ours (M)inutes 23 — Record mode "R" ® Record mode "M" ® MAX mode " I " ® MIN mode "A" ® AVG mode "-" ® MAX-MIN mode " - " ® normal mode 24 — REL & HOLD "R" ® Rel[...]
-
Page 17
15 COMMUNICATION 508BR RS-232C "COM1" PORT 4612-IR232 RS232C CABLE 1. Install the RSR232C cable between computer "COM1" and Thermometer RS232C port. 2. Turn on Thermometer. 3. Utilize the Quick BASIC for inputting programs. 4. Use the capital control letter and input "A" letter from the keyboard to start sending messag[...]
-
Page 18
1 HH501(A,B) K / HH501(A,B) J / HH501(A, B)T / HH501( A,B)E HH508BR/HH508/HH509/ HH509R CA LIBRA TION PROCEDURE Note: The following calibration procedure s hould perform only by qualified technicians who have access to the items as fol lowing. Equipment: The class of calibrator ha d better 10 times g reater than the measur ed meter. 1. Set the jump[...]
-
Page 19
W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warr ants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warr anty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA's customers[...]
-
Page 20
M-3203/0799 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! TEMPERATURE þ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies þ Wire: Thermocouple, RTD & Thermistor þ Calibrators & Ice Point References þ Recorders, Controllers & Process Monitors þ Infrared Pyromet[...]