Omron Healthcare HEM-705CP manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 28 pages
- 0.76 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Blood Pressure Monitor
Omron Healthcare RX3
19 pages 0.5 mb -
Blood Pressure Monitor
Omron Healthcare HEM-CR24
27 pages 1.09 mb -
Blood Pressure Monitor
Omron Healthcare HXA-GCUFF-MLA
1 pages 0.62 mb -
Blood Pressure Monitor
Omron Healthcare HEM-7211-E
27 pages 1.09 mb -
Blood Pressure Monitor
Omron Healthcare HEM-741CREL
56 pages 1.34 mb -
Blood Pressure Monitor
Omron Healthcare HEM-609
48 pages 1.09 mb -
Blood Pressure Monitor
Omron Healthcare BP710
24 pages 3 mb -
Blood Pressure Monitor
Omron Healthcare HEM-412C
16 pages 0.64 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Omron Healthcare HEM-705CP. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Omron Healthcare HEM-705CP ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Omron Healthcare HEM-705CP décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Omron Healthcare HEM-705CP devrait contenir:
- informations sur les caractéristiques techniques du dispositif Omron Healthcare HEM-705CP
- nom du fabricant et année de fabrication Omron Healthcare HEM-705CP
- instructions d'utilisation, de réglage et d’entretien de l'équipement Omron Healthcare HEM-705CP
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Omron Healthcare HEM-705CP ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Omron Healthcare HEM-705CP et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Omron Healthcare en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Omron Healthcare HEM-705CP, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Omron Healthcare HEM-705CP, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Omron Healthcare HEM-705CP. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Automatic Blood Pressure Monitor and Print-Out with IntelliSense™ Model HEM-705CP INSTRUCTION MANUAL R[...]
-
Page 2
[...]
-
Page 3
TITLE T ABLE OF CONTENTS Introduction ...................................................................................................4 Notes on Safety .............................................................................................5 Kno w Y our Unit ...................................................................................[...]
-
Page 4
4 TITLE INTRODUCTION Thank you for purchasing the Omron Automatic Blood Pressure Monitor and Print-Out with IntelliSense ™ , HEM-705CP . Although your blood pressure fluctuates throughout the day , no self-adjustment is necessary as the monitor intelligently adjusts to your changing conditions. The IntelliSense ™ monitor uses fuzzy logic intell[...]
-
Page 5
TITLE NOTES ON SAFETY • The warning signs and the sample icons shown here are listed for you to use the product safely and correctly as well as to prev ent the risk and the damage to you and others from happening. • The icons and meanings are as follo w . W ar ning sign Contents Indicates matters in which bodily harm or material damage* may ari[...]
-
Page 6
6 TITLE KNOW YOUR UNIT ST AR T Button Paper Feed Pulse Rate Arm Cuff Print Graph Date/T ime Display Heart Symbol Air T ube Memory Call Button Systolic Blood Pressure ON/OFF Button A C Adapter Set Date/T ime Adjust Date/T ime Diastolic Blood Pressure Print All Data Print Current Data/Stop Printing Printer Cover Air Plug (Connects to Air Jack) Main U[...]
-
Page 7
TITLE QUICK REFERENCE GUIDE 1. A void eating, smoking, and ex ercising for at least 30 minutes before taking a measurement. 2. Remov e tight-f itting clothing from your upper arm. 3. Sit in a chair with your feet flat on the floor and place your arm on a table so that the cuf f is at the same le vel as your heart. 4. Put your arm through the cuf f [...]
-
Page 8
8 BA TTER Y INST ALLA TION/REPLACEMENT 1. Slide the battery cov er of f in the direction of the arro w . 2. Install or replace 4 "AA" size batteries so the + (positi ve) and – (ne gati ve) polarities match the polarities of the battery compartment as indicated. 3. Replace the battery cov er . Notes: If the Lo w Battery Indicator ( ) app[...]
-
Page 9
9 HOW TO SET TIME AND DA TE 1. When the batteries are installed, the display will sho w 12:00a.m. 2. Press and hold the “ SET ” button. The year digits (2001) will flash. 3. Press the “ ADJUST ” button to adv ance the digit(s) one at a time. If you hold do wn the “ ADJUST ” button, the digits will adv ance rapidly . 4. Press “ SET ”[...]
-
Page 10
10 HOW TO CONNECT PRINTER UNIT 1. Remove printer cable plug from around printer unit. 2. Connect printer cable plug cord to the main unit. Arro w ( ) on printer cable plug should face do wn to main unit.[...]
-
Page 11
11 HOW TO LOAD PRINTER P APER 1. Open printer cov er in the direction indicated by the arro w symbol and remov e paper roll from the main unit. 2. Peel of the glued edge of the printing paper included with the unit, and cut the first 4 inches with a pair of scissors. 3. Press the P APER FEED button while inserting the edge of the printing paper int[...]
-
Page 12
12 HOW TO USE THE OPTIONAL AC ADAPTER T o av oid potential damage to the monitor , use only the exclusi v e A C adapter (Model HEM-ADPT1). T o connect the A C adapter 1. Insert the A C adapter plug into the A C Adapter jack on the back of the main unit. 2. Plug in the A C adapter into a 120V A C outlet (50 - 60 cycles). T o remove the A C adapter T[...]
-
Page 13
13 TITLE HOW TO APPL Y THE ARM CUFF 1. If the cuf f is assembled correctly , the hook material will be on the outside of the cuf f loop and the metal D-ring will not touch your skin. 2. If the cuf f is not assembled, pass the end of the cuf f furthest from the tubing through the metal D-ring to form a loop. The smooth cloth should be on the inside [...]
-
Page 14
14 TITLE HOW TO APPL Y THE ARM CUFF 5. Pull the cuf f so that the top and bottom edges are tightened e venly around your arm. 6. When the cuf f is positioned correctly , press the se wn hook material FIRML Y against the pile side of the cuf f. 7. Make certain the cuf f fits snugly around your arm. The cuf f should make good contact with your skin. [...]
-
Page 15
15 TITLE HOW TO T AKE A READING 1. Press the ON/OFF button. a) All display symbols appear for approximately one second. b) When the monitor becomes ready to measure, the Heart Symbol appears on the display . 2. Press the ST AR T button and remain still. As the cuff be gins to inflate, the monitor automatically determines your ideal inflation lev el[...]
-
Page 16
16 TITLE HOW TO T AKE A READING ST AR T Continue to press button • If your systolic pressure is kno wn to be more than 220 mmHg, push and hold the ST AR T button until the monitor inflates 30 to 40 mmHg higher than your suspected systolic pressure. NOTE: Do not apply more pr essure than necessary . T he monitor will not infla te abov e 300 mmHg. [...]
-
Page 17
17 TITLE HOW TO USE THE MEMOR Y FUNCTION This monitor has a memory capable of storing twenty-eight (28) sets of readings. Every time you complete the measurement, the monitor automatically stores blood pressure and pulse rate. • Push the b utton to recall stored readings while the Heart Symbol ( ) is displayed. • When twenty-eight (28) sets of [...]
-
Page 18
18 HOW TO USE THE PRINTER-UNIT The HEM-705CP has the ability to print all the readings stored in memory . NO TE : • Make sure printer -unit is connected to main unit (see How to Connect Printer-Unit) • Do not use printer -unit without loading printer paper (see Ho w to Load Printer Paper). Improper use will decrease operation life cycle of prin[...]
-
Page 19
19 HOW TO USE THE PRINTER-UNIT The numerical print-out will list all stored readings (maximum of 28 readings) starting with the most recent reading to last stored reading: 3-6 mmHg /min D. T . SYS DIA PUL 20 15 113 75 67 23 11 117 69 64 1 15 113 71 63 3 14 110 67 66 5 7 112 66 64 15 7 110 61 64 20 12 106 66 65 3 12 110 65 64 10 12 108 61 67 12 14 1[...]
-
Page 20
20 HOW TO USE THE PRINTER-UNIT 3. Press “ GRAPH ” b utton to print a graph of all stored readings (stores a maximum of 28 readings). 50 1 00 1 50 2 00 mmHg 3-6 Diastolic Reading Systolic Reading A verage systolic reading of stored measurements A verage diastolic reading of stored measurements Last reading stored Month(s) If reading is lo w er t[...]
-
Page 21
21 TITLE If you continue to hav e dif ficulty obtaining a reading, call OMRON HEALTHCARE CUSTOMER SER VICE TOLL FREE 1-800-634-4350 . Please tell the representativ e you have an OMR ON Model HEM-705CP . Error Indicator Cause Correction Cuff under -inflated. Mov ement during measurement. Cuff o ver -inflated (more than 300 mmHg). Battery voltage is [...]
-
Page 22
22 TITLE If you continue to hav e dif ficulty obtaining a reading, call OMRON HEALTHCARE CUSTOMER SER VICE TOLL FREE 1-800-634-4350 . Please tell the representativ e you have an OMR ON Model HEM-705CP . Error Indicator Cause Correction Printer cable plug is not connected properly or damaged Connect correctly reference p.10 Contact Omron Customer Se[...]
-
Page 23
23 TITLE CAUTION CA UTION: Changes or modifications not e xpressly approved by Omron Healthcare, Inc. could void the user ’ s warranty . NOTE: PO TENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These lim[...]
-
Page 24
24 CARE AND MAINTENANCE T o protect y our monitor from damage, please A V OID the f ollowing: • Subjecting your monitor and cuf f to extreme temperatures, humidity , moisture, and direct sunlight. • Folding the cuf f and tubing tightly . • Inflating the monitor ov er 280 mmHg. • Disassembling the monitor . • Subjecting the monitor to stro[...]
-
Page 25
W ARRANTY Y our HEM-705CP IntelliSense ™ Automatic Blood Pressure Monitor is warranted to be free from manufacturing defects for a period of fi ve years under normal use. The fi ve year warranty e xcludes the monitor cuf f. The cuff is warranted f or a one year period. This warranty e xtends only to the original retail purchaser . Should repair b[...]
-
Page 26
26 SPECIFICA TIONS Model: HEM-705CP Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg Pulse: 40 to 180/minute Accuracy/Calibration: Pressure: ±4 mmHg Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Activ e electronic control valve Rapid Pressure Release: Active electronic control v alve Pressure Detect[...]
-
Page 27
27 SPECIFICA TIONS PRINTER UNIT : Power Source: 4 “ AA ” batteries Batter y Life: Approximately 300 uses (current data) Paper Usage: Approximately 200 uses for 1 roll (current data) (Printer) W eight: Approximately 6 oz. (170 g) (not including batteries) (Printer) Dimensions: Approximately 4 4 ⁄ 5 '' (l) x 2 4 ⁄ 5 '' (w)[...]
-
Page 28
For Customer Ser vice Call T oll Free 1-800-634-4350 Manufactured by OMR ON Distributed by: OMRON HEALTHCARE, INC . 300 Lake vie w Parkway V ernon Hills, Illinois 60061 www .omronhealthcare.com Copyright © 2001 OMR ON HEAL THCARE, INC. 705CPINST Rev A[...]