Patton electronic 1080A manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 15 pages
- 0.13 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Network Card
Patton electronic 2520RC
23 pages 0.41 mb -
Network Card
Patton electronic 1018RC
12 pages 0.3 mb -
Network Card
Patton electronic 1058DVs
5 pages 0.22 mb -
Network Card
Patton electronic 3034/3038
58 pages 1.16 mb -
Network Card
Patton electronic PATTON 2707/I
24 pages 0.18 mb -
Network Card
Patton electronic 2701/C
28 pages 0.8 mb -
Network Card
Patton electronic IM 1/F
6 pages 0.04 mb -
Network Card
Patton electronic 1004S
10 pages 0.07 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Patton electronic 1080A. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Patton electronic 1080A ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Patton electronic 1080A décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Patton electronic 1080A devrait contenir:
- informations sur les caractéristiques techniques du dispositif Patton electronic 1080A
- nom du fabricant et année de fabrication Patton electronic 1080A
- instructions d'utilisation, de réglage et d’entretien de l'équipement Patton electronic 1080A
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Patton electronic 1080A ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Patton electronic 1080A et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Patton electronic en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Patton electronic 1080A, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Patton electronic 1080A, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Patton electronic 1080A. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
USER MANUAL MODEL 1080A and MODEL 1080A-64 Universal Synchronous & Asynchronous Short Range Modems SALES OFFICE (301) 975-1000 TECHNICAL SUPPO R T (301) 975-1007 http://ww w .patton.com Part #07M1080A-D Doc. #072041UD Revised 6/19/98 CERTIFIED An ISO-9001 Certified Company[...]
-
Page 2
1.0 W ARRANTY INFORMA TION Patton Electronics warrants all Model 1080A Series components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unaut[...]
-
Page 3
2.0 GENERAL INFORMA TION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected by Patton's qualified technicians. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics T echnical Support at (301) 975-1007. 2.1 FEA [...]
-
Page 4
Each Model 1080A Series SRM has three sets of eight switches, yielding 24 total DIP switches. The three sets will be referred to as S1, S2 and S3. As Figure 2 shows, the orientation of all DIP switches is the same with respect to “ON” and “OFF” positions. 3.2 CONFIGURA TION SWITCH SET “S1” The DIP switches on S1 set data rate, clock sou[...]
-
Page 5
Switch S1-8: Carrier Control Method The setting for switch S1-8 determines whether the carrier is “constantly on” or “controlled by RTS”. This setting allows for operation in switched carrier , multipoint and/or hardware handshaking applications. S1-8 Setting Off Constantly on On Controlled by RTS 3.3 CONFIGURA TION SWITCH SET “S2” The [...]
-
Page 6
3.4 CONFIGURA TION SWITCH SET “S3” The DIP switches on S3 set the anti-stream control, local loopback enable, remote loopback enable and receive (input) impedance levels for the Model 1080A Series. Factory default positions of Switch S3 are shown in the table below . Switches S3-1 & S3-2: Input Impedance The setting for Switches S3-1 and S3[...]
-
Page 7
Switch S3-6: RS-232 Initiation of Remote Loopback T est The setting for switch S3-6 determines whether or not the Model 1080A Series’ remote digital loopback test can be initiated by raising pin 21 on the RS-232 interface. S3-6 Setting On RS-232 initiation enabled Off RS-232 initiation disabled Switches S3-7 and S3-8: Anti-stream Control Switches[...]
-
Page 8
4.1.1 T wo-Wire Cable Connection Via RJ-45 A. The RJ-45 jack on a Model 1080A Series Short Range Modem is prewired for a standard TELCO wiring environment. T o be sure you have the right wiring, use the table below as a guide. RJ-45 SIGNAL 1 -------------NC 2 -------------GND † 3 -------------RCV 4 -------------XMT 5 -------------XMT 6 ----------[...]
-
Page 9
4.2.1 Four-Wire Cable Connection Via RJ-45 A. The RJ-45 jack on a Model 1080A/1080A-64 Short Range Modem is prewired for a standard TELCO wiring environment. T o be sure you have the right wiring, use the table below as a guide. RJ-45 SIGNAL 1 -------------NC 2 -------------GND † 3 -------------RCV 4 -------------XMT 5 -------------XMT 6 --------[...]
-
Page 10
4.3 FOUR-WIRE, MUL TIPOINT INST ALLA TION Multipoint operation involves the connection of several terminals to one host port. In such an application, one local Model 1080A/1080A-64 is used as a master unit, and it is connected to several remote Model 1080A/1080A-64s that are acting as slaves. Up to 25 Model 1080A Series slaves may be connected to o[...]
-
Page 11
5.1.4 The “Error” Indicators The “Error” indicator LED has three functions: A. When the 1080A Series unit is in test mode (green “T est” LED is lit), the error LED glows red when bit errors occur . B. When not in test mode (green “T est” LED is off), the error LED is used to indicate an RTS streaming condition. (See Section 5.2) for[...]
-
Page 12
5.1.4.2 Reading The T est A. If line quality is good, “Error” LED on local modem will not light and “CD” LED will be red. On remote modem “Error” LED will not light and “CD” LED will light green. B. If flat cable is used or parts of the line are flat cable, “Error” LED on local modem will light red and “CD” LED will light gr[...]
-
Page 13
A. Activate RDL. This may be done in two ways: First, by moving the front panel toggle switch UP to "Remote". Second, by raising pin 21 on the RS-232 interface (Note: Make sure DIP switch S3-6 is ON; and DIP switch S2-6 is OFF). B. Perform a BER (bit error rate) test on the system. C. If the BER test equipment indicates a fault, and the L[...]
-
Page 14
APPENDIX B P A TT ON MODEL 1080A SERIES F ACT OR Y REPLACEMENT P ARTS AND ACCESSORIES Patton Model # Description 080510ACB .....................120V W all Mount AC Adapter 08059ACI ........................230V AC Adapter (No Power Cord) 07M1080A .......................Model 1080A Series User Manual 25 APPENDIX C P A TT ON MODEL 1080A SERIES CABLE R[...]
-
Page 15
APPENDIX C P A TT ON MODEL 1080A SERIES INTERF ACE PIN ASSIGNMENT RS-232 FEMALE, D-SUB 25 CONNECTOR (DCE ORIENT A TION) 1- (FG) Frame Ground 2- (TD) T ransmit Data T o 1080A 3- (RD) Receive Data From 1080A 4- (RTS) Request to Send T o 1080A 5- (CTS) Clear to Send From 1080A 6- (DSR) Data Set Ready From 1080A 7- (SG) Signal Ground 8- (DCD) Data Carr[...]