Patton electronic 1194 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 24 pages
- 0.3 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Network Card
Patton electronic 2211
2 pages 0.17 mb -
Network Card
Patton electronic 2311M
16 pages 0.69 mb -
Network Card
Patton electronic 2112
10 pages 0.64 mb -
Network Card
Patton electronic 3054
9 pages 0.2 mb -
Network Card
Patton electronic 2784 NAU
4 pages 0.66 mb -
Network Card
Patton electronic 2312M
16 pages 0.69 mb -
Network Card
Patton electronic 1020S
8 pages 0.09 mb -
Network Card
Patton electronic 1110
6 pages 0.07 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Patton electronic 1194. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Patton electronic 1194 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Patton electronic 1194 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Patton electronic 1194 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Patton electronic 1194
- nom du fabricant et année de fabrication Patton electronic 1194
- instructions d'utilisation, de réglage et d’entretien de l'équipement Patton electronic 1194
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Patton electronic 1194 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Patton electronic 1194 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Patton electronic en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Patton electronic 1194, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Patton electronic 1194, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Patton electronic 1194. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
USER MANUAL MODEL 1194 Single Mode Fiber Modem With Four Fixed E1/T1 Interfaces SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 P ar t# 07M1194-A Doc# 017151U A Released 06/04/01 An ISO-9001 Certified Company CERTIFIED[...]
-
Page 2
2 T ABLE OF CONTENTS 1.0 Warranty Information .................................................................. 4 1.1 Industry Canada Notice ................................................................ 4 1.2 FCC Information ........................................................................... 5 1.3 DC Power Notice .......................[...]
-
Page 3
3 Physical Connection ................................................................... 22 A.4 Fiber Port Specifications ..............................................................23 Fiber Line Coding ....................................................................... 23 Fiber Physical ......................................................[...]
-
Page 4
4 1.0 W ARRANTY INFORMATION P atton Electronics warrants all Model 1194 components to be free from def ects, and will—at our option—repair or replace the product should it f ail within one year from the first date of shipment. This warranty is limited to def ects in w orkmanship or mater ials, and does not cov er customer damage, ab use or una[...]
-
Page 5
5 and internal metallic water pipe system, are connected together . This protection ma y be par ticularly impor tant in r ural areas. 1.2 FCC INFORMATION This equipment has been tested and f ound to comply with the limits f or a Class A digital de vice, pursuant to P art 15 of the FCC Rules. These limits are designed to provide reasonab le protecti[...]
-
Page 6
6 An approv ed external SEL V power supply that incor porates a disconnect de vice must be used and positioned within reach of the operator’ s position. 1.4 PATTON CONTACT INFORMATION If you ha v e an y troub le operating the Model 1194, please contact P atton Electronics T echnical Suppor t at 301-975-1000 . The telephone com- pany ma y ask you [...]
-
Page 7
7 2. Y our telephone compan y may make changes to its f acilities, equip- ment, operations, or procedures that could aff ect the proper func- tioning of your equipment. The telephone company will notify y ou in advance of such changes to giv e you and oppor tunity to maintain uninterrupted telephone ser vice. 3. If your CSU causes harm to the telep[...]
-
Page 8
8 2.0 GENERAL INFORMATION Thank you f or your purchase of this P atton Electronics product. This product has been thoroughly inspected and tested and is warranted f or One Y ear par ts and labor . If any questions or problems arise during installation or use of this product, please do not hesitate to contact P atton Electronics T echnical Support a[...]
-
Page 9
9 Figure 2. Network extension between remote locations Using a laser transmitter (1300nm) and a single-mode fiber (9/125 micro meter), the Model 1194 off ers a high speed, noise immune , full duple x fiber link ov er a single str and of fiber with a reach of up to 15.5 miles (25.0 km). The Model 1194 is av ailable in two v ersions: 1194/T1 and 1[...]
-
Page 10
10 3.0 CONFIGURATION The Model 1194 has 16 DIP s witches that enab le configuration of the unit f or a wide v ar iety of applications. This section describes location of the s witches and e xplains the different configurations . 3.1 CONFIGURING THE HAR DWARE DIP SWITCHES Using a small flat-tip screwdriv er , remov e the protectiv e cov er locate[...]
-
Page 11
11 Configuring DIP switch S1 Switches S1-1 through S1-8 are used to configure clocking modes and line coding. Default settings of the s witches are shown in T able 1. Descriptions of the switch options f ollow the table . Switch S1-1: Line Coding Options. Use s witches S1-1 to deter mine the line coding of the network interface ports. The setting[...]
-
Page 12
12 tions and decodes them as zeros . This method enables the network to meet minimum pulse density requirements. • Bipolar 8 Zero Substitution (B8ZS ): This mode assures proper bit density in the data stream. In this mode any data pattern can be trans- mitted without causing ones density errors. This mode allows f or 64 kbps clear channel timeslo[...]
-
Page 13
13 Configure DIP switch S2 Switches S2-1 through S2-8 are f or configur ing Local/Remote Loop , RDL response, and front panel s witch oper ation (see T able 2). Descriptions of the s witch options follo w the table. Switch S2-1: Local/Remote Loop. Switch S2-1 determines which Loop can be activated from the front panel loop s witches (P1 to P4) Sw[...]
-
Page 14
14 4.0 INSTALLATION Once the Model 1194 is configured, it is ready to connect to the fiber interf ace , to the E1/T1 equipment, and to the power source. This section describes how to make these connections . The power , network (E1/T1), and fiber line connections are located on the rear panel of the Model 1194. Figure 5 shows the location of eac[...]
-
Page 15
15 Figure 7. Single-mode fiber connectors (FC and SC) . 4.3 POWER CONNECTION The Model 1194 is av ailable with two pow er supply options: • Universal Interface A C P ower Supply option (Model 1194-UI ) oper- ates in environments r anging from 100 to 240 V AC , with no re-configu- ration necessary (see Appendix B f or av ailable domestic and int[...]
-
Page 16
16 3. Set the ON/OFF power s witch (see Figure 8) to ON. Figure 8. P ower switch location Connecting to a DC P ower Source The 48 VDC power supply option uses a 3-pin terminal block with spring- type connectors. Please ref er to the Model 1090 Series Ser vice Manual f or the power line v oltage connections. Figure 9. DC power connection W ARNING Th[...]
-
Page 17
17 5.0 POWER-UP T o apply pow er to the Model 1194, first be sure that the unit is connected to the appropriate power source. Then do the f ollowing: 1. Set front panel s witches to the center position 2. Plug the provided A C or DC power into the Model 1194. 3. Set the ON/OFF power s witch (see Figure 8 on page 16) to ON. After the local and remo[...]
-
Page 18
18 6.0 LED STATUS MONITORS The Model 1194 f eatures front panel LEDs that monitor power , network, fiber , and diagnostic signals. Figure 10 shows the front panel location of each LED . T able 3 describes each LED’ s function. Figure 10. F ront panel picture of 1194 T able 3: F ront panel LED descriptions LED LED color Description PO WER Green I[...]
-
Page 19
19 7.0 T EST MODES The f ollowing section describes the test patter ns and loopbacks used in the Model 1194. The Model 1194 off ers local/remote loopbac k tests, plus a built-in V .52 BER test patter n generator to e v aluate the condition of the modems and the network (T1/E1 lines) and fiber links. These tests can be activated ph ysically from th[...]
-
Page 20
20 T o test the local connection, do the f ollowing: 1. Set S2-1 to the OFF position. 2. Locate the por t label (P1-P4) abov e or below the front panel s witches, Activ ate local loopback f or a network por t by moving the appropriate front panel toggle switch UP or DO WN. A yellow TM LED corresponding to the por t under test will tur n on. 3. A BE[...]
-
Page 21
21 T o test the fiber connection, do the f ollowing: 1. Set S2-1 to the ON position. 2. Locate the por t label (P1-P4) abov e or below the front panel s witches, Activ ate Remote Loopback f or a network por t by moving the appropriate front panel toggle switch UP or DO WN. A green TM LED corresponding to the por t under test will tur n on. A BER t[...]
-
Page 22
22 APPENDIX A MODEL 1194 QUAD E1/T1 TO SINGLE MODE FIBER SPECIFICATIONS A.1 CONFIGURATION Externally accessible dip switches A.2 CLOCKING MODES Network (E1/T1), Inter nal, Receiv e Recov er (fiber Link) A.3 NETWORK PORTS SPECIFICATIONS Network Line Rate 2048 kbps (G.703), 1.544Mbps (T1) T ransmit Line Buildout (T1) 0 dB, -7.5 db , -15 db , and -22[...]
-
Page 23
23 A.4 FIBER PORT SPECIFICATIONS Fiber Line Coding 8B10B Fiber Physical • Connection: One strand of 9/125 micron single-mode fiber with FC or SC connectors • T ransmission Line: Single fiber • Link Budget: 13 dB A.5 DIAGNOSTICS V .52 compliant (511/511E) patter n generator and detector with error injection mode. Remote Loopbac k (toward fi[...]
-
Page 24
24 A.12 HUMIDITY 5 to 95%, non-condensing A.13 DIMENSIONS 7.3 W x 6.6 D x 1.62H in. (185 W x 168 D x 41 H mm) A.14 WEIGHT 2.01 lbs. (1.0kg ) A.15 MEAN TIME BETWEEN FAILUR E (MTBF) 113,258 hours, based on MIL-HDBK-217F , Notice 2.[...]