QSC Audio BASIS 922dz manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 28 pages
- 1.92 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Stereo System
QSC Audio DSP-3
36 pages 2.61 mb -
Stereo System
QSC Audio BASIS 922dz
28 pages 1.92 mb -
Stereo System
QSC Audio RAVE 520uz
28 pages 1.54 mb -
Stereo System
QSC Audio DSP0002
4 pages 0.09 mb -
Stereo System
QSC Audio 914LZ
28 pages 2.59 mb -
Stereo System
QSC Audio DSP-4 RS-232
2 pages 0.06 mb -
Stereo System
QSC Audio HPR122i, HPR152i, HPR153i, HPR151i, HPR181i
24 pages 7.67 mb -
Stereo System
QSC Audio 922uz
2 pages 0.18 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation QSC Audio BASIS 922dz. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel QSC Audio BASIS 922dz ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation QSC Audio BASIS 922dz décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation QSC Audio BASIS 922dz devrait contenir:
- informations sur les caractéristiques techniques du dispositif QSC Audio BASIS 922dz
- nom du fabricant et année de fabrication QSC Audio BASIS 922dz
- instructions d'utilisation, de réglage et d’entretien de l'équipement QSC Audio BASIS 922dz
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage QSC Audio BASIS 922dz ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles QSC Audio BASIS 922dz et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service QSC Audio en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées QSC Audio BASIS 922dz, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif QSC Audio BASIS 922dz, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation QSC Audio BASIS 922dz. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
TD-000202- 00 rev .B *TD-000202-00* BASIS 922dz 8x8 CobraNet Enabled Control and Monitoring Signal Processor Hardware Manual[...]
-
Page 2
2 IMPORTANT SAFETY PRECAUTIONS & EXPLANATION OF SYMBOLS The lightning flash with arrowhead symbol wit hin an equilateral tri angle is intended to al ert the user to the presence of uninsula ted “dangerous” voltage within the product’ s enclosure t hat may be of sufficien t magnitude to constit ute a risk of electri c shock to humans. The [...]
-
Page 3
3 Introduction 1- Power indicator 2- Diagnostic indicator 3- Network status indicators 4- Port connection status indicators 5- Multi-function push buttons 6- Display 7- Rotary select/accept knob 8- Safe Mode switch (recessed) 9- DataPorts 10- AES/EBU inputs 11- Monitor chain in/out 12- Relay outputs 13- Logic outputs 14- Omni inputs 15- RS-232 port[...]
-
Page 4
4 0.396 milliseconds. From digital input to analog output, the total delay is 2.167 milliseconds. The delay does not change regardless of the DSP configur ation, unless the configura- tion intentionally adds more delay . The BASIS 922dz also supports the new optional low- latency CobraNet feature that provides transport at only 2.66 milliseconds de[...]
-
Page 5
5 Introduction - Networ king the BASIS 922dz The BASIS 922dz has two RJ-45 network connection ports on the r ear panel. One port is labeled "QSControl" and supports standard 10BASE-T Ethernet. The other port is labeled "CobraNet" and supports 100BASE-TX, also k nown as "Fas t Ethernet". In the followi ng sections we de[...]
-
Page 6
6 Third, the BASIS 922dz and QSControl.net system are targeted at network switch deployments. The consumer costs of Ethernet switches have continued to fall over the last several years and are now comparable with repeaters on a per port basis. In addit ion, the sophistication and scalability of network switches make them i deal for new installation[...]
-
Page 7
7 Example #2 - CobraN et X-over mode: This is the simplest connection you can make between two BASI S boxes. Use a CA T -5 crossover cable connected between the Cobra- Net ports of each unit. No network switch is required. This connection allows audio to pass between the two BASIS boxes over Co bra- Net. Combining example 1 and 2 lets you setup and[...]
-
Page 8
8 Example #3 - Singl e Wire Interface: Here all QSControl.net and CobraNet traffic shares the sa me single CA T -5 cable between the BASIS 922dz and an unmanaged Etherne t switch. The QSControl.net system manages traffic flow efficiently and reliably so that all audio and control data is delivered to its appropriate destination anywhere on the netw[...]
-
Page 9
9 Example #4 - T wo-Wire Interf ace (shared network hardware): This example illustrates the T wo-Wire Interface with a managed Et hernet switch. The switch is configured with multiple virtual local area networks (VLANs). Ethernet deliveries can only reach des tination ports belonging to the same VLAN from which it was sourced. The figure shows a se[...]
-
Page 10
10 Example #5 - T wo-Wire Interf ace (separate netwo rk hardware): Example #5 is conceptually similar to example #4. The differenc e here is that separate networks are created by providing each l ocal area network (LAN) with its own network switch. Therefore, tra ffic segmentation is physical rather than logical. Ex ample #5 also pro- vides an addi[...]
-
Page 11
11 Unpacking There are no special unpacking precautions. However , it is recomm ended you keep the original pa cking material for reuse in the rare event that service be required. If service is required and the or iginal packing material is not available, ensure that the unit is adequately protected for shipment (strong box of appropriate size, suf[...]
-
Page 12
12 Computer Requirements & Software Installation Installing QSControl.net is easy . All you need to do is choose th e folder where the program is to be stored (the default settin g is accept- able for most applications). We recommend your syste m meet the following minimum requirements: 1- IBM PC compatible computer with a Pentium 4 processor .[...]
-
Page 13
13 General Information & Configuration Memories Amplifier Setup The QSC DataPort-equipped amplifiers connected to the BASIS 922dz must have their power switches in the “on” position. For init ial testing, use the lowest useful gain setting until the system is operating as expected. After the system setup has been verified and tested, gain s[...]
-
Page 14
14 Connections AC Power Cord Insert the molded receptacle of the AC power cord into the AC power inlet on the back of the BASIS 922dz. Plug the AC line connector into the AC outlet. The power supply will accept from 100 to 240 V olts AC, 47 to 440 Hertz, without any changes. If a different type of IEC power cord is required than supplied with your [...]
-
Page 15
15 Monitor Chain connectio n. See explanation, at le ft. In Out Monitor Chain The MONITOR CHAIN connector is a 5-pin terminal block connector . Input and output connec- tions are balanced. The center pin is the shield connection for both the input and output of the monitor chain. Connection is shown at right. The left-most + and - terminals are for[...]
-
Page 16
16 LED Indicators (continued) QSControl and Cobra Net Network St atus (Port) Indicators- There are two groups of three LEDs on the front and rear panels labeled RX, TX and LINK. One group is for the QSControl network po rt and the other for the CobraNet network port. Their functions are described below . Note: Port indicators on rear panel are colo[...]
-
Page 17
17 LCD Navigation Map Left side button s have screen depe ndent functio ns. This read- only screen is the “out of the box” default display after power up. This is the most desired infor- mation when first sett ing up a network system. Once user moves to a different scre en, the last screen accessed become s the new power up default. Boot Screen[...]
-
Page 18
18 Getting Started This section outlines one of the simpler methods of getting familiar with your BASIS and the QSControl.net software. The goal o f this procedure is to get your computer and the BASIS connected and co mmunicating and the QSControl.net software installed and runnin g. After the software is installed and running, refer to the softwa[...]
-
Page 19
19 Getting Started (continued) 17- Select Device , Add Device , from the menu. A new window will open prompting you to name the device. Name it logically , such as BASIS 1, or similar . Select the Device T ype and select BASIS 922dz. At the Password prompt, enter “qsc” (lower case, no quot ation marks). This is the device password, separate fro[...]
-
Page 20
20 Operation QSControl Port The QSControl port operates on a 10BaseT Ethernet network. This por t is one of the primary means for connecting QSControl.net to the BASIS. The port may connect directly to a PC's 10BaseT or 10/100 (auto-sensing or auto-neg otiating) network interface card usin g a crossover cable. Data from the QSControl port may [...]
-
Page 21
21 Utility/Diagnostic Functions Safe Mode Switch Location of Safe Mode switch: The front panel has a small access hole on the left side, just left of the Power indicator . It is not labeled to help prevent accidental use. The Safe Mode switch c an be operated by using a paper -clip (or similar item) inserted i nto the access hole and pushing. Safe [...]
-
Page 22
22 Utility/Diagnostic Fu nctions (continued) RS-232 Communications Procedure: 1) Connect the RS-232 port of the BASIS 922dz to an unused serial po rt (COM port) of a PC using a normal (straight-through) serial cable. 2) Open the HyperT erminal program. This p rogram is usually star ted by clicking the Windows ST ART icon, highlighting PROGRAMS, the[...]
-
Page 23
23 Utility/Diagnostic Fu nctions (continued) T elnet Access The RS-232 features can also be accessed via T elnet. The Micros oft T elnet application is a Windows program. Consult Windows documentation for T e lnet information. Basic procedure for opening a T elnet session: 1 - T o open the T elnet session- Click ST ART , select RUN, type “T elnet[...]
-
Page 24
24 Preliminary Specification IN OUT THRU Dynamic Range (A ES-17, -60dB Method, all sensit ivities) unweighted >140dB >112dB >112dB A weighted >140dB >115dB >115dB Distortion (20Hz-20 KHz, all sen sitivities) +4dBu (max) <0.009% THD+N <0.009% THD+N <0.009% THD+N 2dB below clip (max) <0.009% THD+N <0.009% THD+N <0.[...]
-
Page 25
25 Preliminary Specification Control Room Foldba ck Monitoring Connector T ype 5-pin "Phoenix Style" (a.k.a . "Euro Style") detachable terminal blocks Pinout 1:+(input) 2:-(input) 3:CHASSIS GND 4:-(output) 5:+(output) T ap points 8 internal input, 8 internal output, 8 amp lifier (pre-, post-, amplifier) software-selectable Monit[...]
-
Page 26
26 Dimensions[...]
-
Page 27
[...]
-
Page 28
QSC Audio Products, Inc. 1675 MacArthur Boulevard Costa Mesa, California 92626 USA ©2005, 2006 “QSC” and the QSC logo are registered with the U.S. Patent and T rademark Office. How to Contact QSC Audio Products Mailing address: QSC Audio Products, Inc. 1675 MacArthur Boulevard Costa Mesa, CA 92626-1468 USA T elephone Numbers: Main Number (714)[...]