Rackmount Solutions XRT Series manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 43 pages
- 1.94 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Power Supply
Rackmount Solutions 1000VA
15 pages 0.69 mb -
Power Supply
Rackmount Solutions VA 10000
58 pages 1.72 mb -
Power Supply
Rackmount Solutions VA 1000
58 pages 1.72 mb -
Power Supply
Rackmount Solutions VA 6000
58 pages 1.72 mb -
Power Supply
Rackmount Solutions VA 2000
58 pages 1.72 mb -
Power Supply
Rackmount Solutions E700RM1U
28 pages 2.19 mb -
Power Supply
Rackmount Solutions PRO1500E
24 pages 2.18 mb -
Power Supply
Rackmount Solutions PRO1100E
24 pages 2.18 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Rackmount Solutions XRT Series. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Rackmount Solutions XRT Series ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Rackmount Solutions XRT Series décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Rackmount Solutions XRT Series devrait contenir:
- informations sur les caractéristiques techniques du dispositif Rackmount Solutions XRT Series
- nom du fabricant et année de fabrication Rackmount Solutions XRT Series
- instructions d'utilisation, de réglage et d’entretien de l'équipement Rackmount Solutions XRT Series
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Rackmount Solutions XRT Series ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Rackmount Solutions XRT Series et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Rackmount Solutions en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Rackmount Solutions XRT Series, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Rackmount Solutions XRT Series, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Rackmount Solutions XRT Series. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
1-866-207-6631 | www .rackmountsolutions.net sales@rackmountsolutions.net[...]
-
Page 2
1[...]
-
Page 3
2 XRT Series User ’ s Manual Table of Contents 1. INTRODUCTION 2 RECEIVING INSPECTION 3 SAFETY INSTRUCTIONS 4 2. SYSTEM DESCRIPTION 6 FEATURES 7 3. INSTALLATION 9 CAUTIONS 9 PROTECTION STRATEGIES 9 INSTALLATION PLACEMENT 9 INSTALLATION, STEP BY STEP 11 4. OPERATION 15 FRONT PANELS 15 ALARMS AND WARNINGS 22 WARNING EVENTS 23 OPTIONS 23 5. SYSTEM B[...]
-
Page 4
3 1. INTRODUCTION Thank you for purchasing the Minuteman XRT series of Uninterruptible Power Supplies. It has been designed and manufactured to provide many years of trouble free service. IMPORTANT! Please read this manual before installing your UPS as it provides the information to correctly set up your system for the maximum safety and performanc[...]
-
Page 5
4 organization. Therefore, these units do not meet the requirements for use in direct patient care.[...]
-
Page 6
5 RECEIVING INSPECTION After removing your Minuteman XRT UPS from its carton, it should be inspected for damage that may have occurred in shipping. Immediately notify the carrier and place of purchase if any damage is found. Warranty claims for damage caused by the carrier will not be honored. PLEASE SAVE THE PACKING MATERIALS! The packing material[...]
-
Page 7
6 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS; Read this manual carefully before operating the UPS. All instructions and warnings should be followed during installation, operation and maintenance of the UPS. CAUTION: RISK OF ELECTRICAL SHOCK. HAZARDOUS LIVE PARTS INSIDE THIS POWER SUPPLY [...]
-
Page 8
7 INSTRUCTIONS IMPORTANTES CONCERNANT LA SÉCURITÉ CONSERVER CES INSTRUCTIONS . CETTE NOTICE CONTIENT DES INSTRUCTIONS IMPORTANTES CONCERNANT LA SÉCURITÉ. ATTENTION: RISQUE DE CHOC ÉLECTRONIQUE. CE BLOC D ’ALIMENTATION COMPORTE DES PIECES SOUS TENSION DANGEREUSE ALIMENTÉES PAR LES PILES MEME LORSQU ’ IL EST DÉBRANCHÉ DU SECTEUR. ATTENTIO[...]
-
Page 9
8 2. SYSTEM DESCRIPTION The XRT series of Uninterruptible power supplies are based on an advanced true sinewave power system that filters and protects the electronic equipment from all types of power line problems. The various models provide from 600 VA to 2000 VA of power for voltage ranges of 120 VAC, 208 VAC and 240 VAC single phase 60 Hz. units[...]
-
Page 10
9 FEATURES Extended Battery Run Time All models of the XRT series may add multiple optional external XRTBP battery packs to extend the time that the units can provide power. UPS de-rating is not required for the additional battery packs. The XRT600 model contains an internal battery, whereas the higher power models require at least one XRTBP batter[...]
-
Page 11
10 commands from the computer can control the UPS. The interface also allows a single switch to control the output power from the UPS so that a user-supplied Output Power Off switch or relay can immediately remove power from the load, or restore power once the problem has been corrected. See Remote Communications chapter for details of the communic[...]
-
Page 12
11 3. INSTALLATION CAUTION: Do not connect a laser printer to the UPS along with other computer equipment unless the UPS is rated at 2000 VA or higher. A laser printer periodically draws significantly more power than when idle, and may overload the UPS. Verify that the UPS can support the loads when the printer is in full operation (printing). PROT[...]
-
Page 13
12 Do not place anything on the top of the UPS. Avoid locations near heating devices. Avoid locations near water or excessi ve humidity. Do not expose the UPS to direct sunlight. Route power cords where they cannot be walked on or damaged, or surrounded by other power cords or communication cables. Use common sense about placing the UPS where it ca[...]
-
Page 14
13 INSTALLATION, STEP BY STEP 1. I nsure UPS Power switch is OFF. Place the optional XRTBP battery pack(s), if used, and XRT UPS in its final location. 2. When installing the XRT1000 and above UPS ’s or the XRT600 with optional battery pack(s): a) Remove the self stick protective strip from the rear of the XRT600 (not required on XRT1000 , 1500, [...]
-
Page 15
14 3. If you have additional Transient Voltage Surge Suppression (TVSS) devices in your system, they may be connected to the Earth Ground lug at the rear of the UPS. This provides a single point connection to minimize the potential of surges to disrupt the system. This lug is connected to the SAFETY GROUND lead in the AC input power cable. 4. Plug [...]
-
Page 16
15 automatically run a self test and at the successful completion, provide power to the output receptacles and indicate “normal AC”. Certain faults will prevent the UPS from supplying power to your equipment and will cause an error status to be displayed and an audible alarm to sound. If this occurs see the TROUBLESHOOTING section. To insure th[...]
-
Page 17
16 Front Panel Load Menu on LCD Screen If an alarm condition exists, the condition will be reported on the front panel. If no AC Power is present and the battery is charged, pressing the DC START switch for approximately 5 seconds will bring up the UPS in the inverter mode and provide power to the protected equipment from the battery.[...]
-
Page 18
17 4. OPERATION FRONT PANELS The operation of the UPS depends on which front panel is used. The following section explains the operation for the LED and the LCD front panels. LED Front Panel The top four LED ’ s (Green) provide 3 functions. • During normal AC operation : The top LED ’s indicate a measure of load. • During battery mode: The [...]
-
Page 19
18 Switches The Power switch turns the unit on and off. To start the UPS when AC power is not available, press and hold the DC Start button for about 5 seconds. The Test/Alarm Silence Button The Test/Alarm Silence button allows you to run the quick self test when the UPS is in the normal mode. If an error was detected and you wish to reset the erro[...]
-
Page 20
19 If the unit is being powered from the AC line, the percentage of actual load power available will be shown by the “ON-LINE xxx% Load” message. Otherwise, if the unit is being powered from the battery, “BACKUP xx.xV BAT” message is displayed. In either case, you may press the button under the “MENU” selection to step to the STATUS men[...]
-
Page 21
20 Status Menu The status menu allows you to read the parameters of the UPS according to the flowchart shown below. The button under the word “Scroll” will step you to the next selection and the button under the word “Menu” will step you to the TEST menu. NOTE: If a power event is happening, the screen describing the event will appear. Load[...]
-
Page 22
21 Test Menu The Test menu allows you to select the user controlled test modes. The “Quick Test” mode will perform a test of all of the key parameters of the UPS, including operation from the battery. The “Test To Low Bat” selection will place the UPS in the battery power mode, and run until the battery voltage drops to the Low Battery Warn[...]
-
Page 23
22 Setup Menu The Setup menu allows you to set some of the UPS operating parameters. The parameters that can be set include the following ; Note: At any step in the “Setup” menu, pressing the “MENU” selection will move you to the “ Config” menu. Audio Alarm xxx : Turn the Audible Alarm on or off. If the Alarm is OFF, the beeper will NOT[...]
-
Page 24
23 Config Menu The configuration menu displays the configuration of the UPS. This information is required when you contact Minuteman ’s technical support. Pressing the “Menu” button will return to the “Mode Display” menu. Config Menu Menu Scroll Model XRTxxxx Menu Scroll S/N xxxxxxxxxx Menu Scroll Mfg Code xxxx Menu Scroll XRT Vxx.xx Menu[...]
-
Page 25
24 ALARMS AND WARNINGS Alarms Conditions that may require immediate attention will be signaled by the UPS beeping it ’s audible alarm. The following is a list of alarms the XRT UPS reports: On Battery (AC Fail) When the UPS has detected a condition that forces it to run from the battery, an alarm will sound every 30 seconds. The alarm stops when [...]
-
Page 26
25 WARNING EVENTS Line Voltage Regulation The UPS will warn you when the incoming utility power exceeds its normal limits. On the LED front panel the Voltage Regulator LED will light, indicating the incoming voltage is out of range. On the LCD front panel, you will see a “Low Voltage In” or “High Voltage In” message. In either case the audi[...]
-
Page 27
26 5. SYSTEM BATTERIES The batteries used in the XRT series of UPS ’s and the XRTBP battery packs are sealed, maintenance-free, lead-acid batteries, with the electrolyte completely absorbed in the plates and separator material. For maximum battery life, battery temperature should be kept as cool as practical indoors. Expected average battery life[...]
-
Page 28
27 BATTERY REPLACEMENT It is recommended that you turn the UPS off and disconnect the input power cord from the receptacles prior to connecting or disconnecting the battery terminals. Only UPS ’s that have external battery packs can be changed “HOT”, that is with AC power connected to the unit, and while supplying power to your equipment. If [...]
-
Page 29
28 6. TROUBLESHOOTING If your XRT UPS does not function as you expect or if you get an error code or message, please follow the chart outlined below before calling your dealer or Minuteman. Make note of each problem so that we may quickly troubleshoot and correct the problem. Please remember to have your model and serial number before calling. TROU[...]
-
Page 30
29 INITIAL ERROR MESSAGES As soon as the UPS is first turned on, it performs a series of self tests. If the self tests fail then the UPS will report the failure and display the fault. If the self test passes, but the UPS was shut down previously due to a fault, the previous fault code or message will be displayed. This feature allows you to determi[...]
-
Page 31
30 The LCD reporting screen in the XRT1000 and above UPS ’s allows much more flexibility in communicating faults to you, and therefore has two classes of fault messages. The first occurs when the unit is initially turned on as explained above, and the second is if a fault is detected during normal operation or testing. Model XRT1000 and above err[...]
-
Page 32
31 OPERATING FAULTS If, during operation, a fault is detected the XRT UPS will sound the alarm beeper and display the fault cause on the front panel. If you have disabled the alarm beeper, the fault will still be displayed. In the XRT600 UPS the upper four LED’s will be turned on according to the chart provided earlier. In the XRT1000 and above, [...]
-
Page 33
32 SELF TEST To have the XRT600 UPS perform a 10 second self test, press the Test/Alarm Silence key. This will perform the self test and report any errors to the LED display. A successful self test is indicated by the normal AC LED being lit. For the XRT1000 and above units, select the TEST MENU on the LCD screen and then select the QUICK TEST. The[...]
-
Page 34
33 7. OBTAINING SERVICE If the UPS requires service: 1. Use the TROUBLESHOOTING section 6 to eliminate obvious causes. 2. Verify that no circuit breakers are tripped. A tripped circuit breaker is the most common problem. 3. Go to section 6 and perform the self test to identify any reported errors. 4. Call your dealer for assistance. If you cannot r[...]
-
Page 35
34 cannot accept any package without the RMA # marked on the outside of the shipping box. 7. Return the UPS by insured, prepaid carrier to: Minuteman, Para Systems Inc. 1455 LeMay Drive Carrollton, Tx. 75007[...]
-
Page 36
35 7. GENERAL PRODUCT SPECIFICATIONS XRT600 (XRT600/2) XRT1000 (XRT1000/2) XRT1500 XRT2000 (XRT2000/2) XRT2001 XRT2002 Acceptable input volts 92-140v (169-268v) 92-140v (169-268v) 92-140v N/A 92-140v (169-268v) 176-278v 152v-267v Output Voltage (on-line) +/- 10% 120v (230v) 120v (230v) 120v N/A 120v (230v) 120v/240v 120/208v Nominal input frequency[...]
-
Page 37
36 Size (H X W X D) 10 x 8.75 x 19.75 in. (25.4 x 22.2 x 50.2 cm.) Weight net 59 lb. (26.82 kg.) 50 lb. (22.73 kg.) 72 lb. (32.73 kg.) 74 lb. (33.64 kg.) Battery packs XRTBP1 (48 VDC 17 AH) XRTBP3 (48 VDC 90 AH) BP SIZE (H X W X D) 10 x 8.75 x 19.75 in. (25.4 x 22.2 x 50.2 cm.) 15.5 x 15.0 x 25.0 in. (39.4 x 38.1 x 63.5 cm.) Weight net 66 lb. ( 30 [...]
-
Page 38
37 REMOTE COMMUNICATIONS Remote communications and control may be implemented via the DB-9 communications port. This interface is compatible with the Minuteman Sentry or PowerMon software. The connector interface is shown below; Pin Function 1 Unused 2 Transmitted Serial Data from UPS 3 Received Serial Data to UPS 4 AC Fail from UPS (simulated Norm[...]
-
Page 39
38 REMOTE DIRECT COMMUNICATIONS Pin 1: Not Used Pin 2: LBW Outp ut signal from UPS (RS232 levels) High signal (+3 to +12 volts)= Low Battery Warning Pin 3: UPS Shutdown Input signal to UPS, Shuts down UPS (RS232 levels) High signal (+3 to +12 volts) = UPS OFF Pin 4: AC Fail NO. Output signal from UPS, open collector, High impedance = AC OK Low impe[...]
-
Page 40
39 BATTERY PACK AND RUNTIME SPECIFICATIONS APPROXIMATE RUNTIMES IN HOURS RUNTIMES MAY VARY BASED ON ACTUAL LOAD AND AGE OF BATTERIES XRT600 LOAD VA INT. BAT PLUS ONE XRTBP1 PLUS TWO XRTBP1 PLUS THREE XRTBP1 PLUS ONE XRTBP3 PLUS TWO XRTBP3 50 10.2 35.0 59.0 72 72 72 75 5.9 20.4 42.2 64.2 72 72 100 4.6 15.7 32.7 46.3 68.4 72 150 2.8 9.6 20.6 29.2 43.[...]
-
Page 41
40 APPROXIMATE RUNTIMES IN HOURS RUNTIMES MAY VARY BASED ON ACTUAL LOAD AND AGE OF BATTERIES LOAD VA ONE XRTBP1 TWO XRTBP1 THREE XRTBP1 ONE XRTBP3 TWO XRTBP3 XRT1000, XRT1500, XRT2000 50 24.8 53.6 72 72 72 XRT1000, XRT1500, XRT2000 75 14.4 31.3 52.5 72 72 XRT1000, XRT1500, XRT2000 100 11.1 24.4 40.7 63.4 72 XRT1000, XRT1500, XRT2000 150 6.8 15.5 25[...]
-
Page 42
41 XRT2000 1700 .2 .8 1.4 2.4 5.8 XRT2000 1800 .2 .7 1.3 2.2 5.4 XRT2000 1900 .2 .6 1.2 2.1 5.1 XRT2000 2000 .2 .6 1.1 2.0 4.8 8. LIMITED PRODUCT WARRANTY Para Systems Inc. (Para Systems) warrants this equipment, when properly applied and operated within specified conditions, against faulty materials or workmanship for a period of two years from th[...]
-
Page 43
42 cost of substitutes, claims by third parties, or otherwise. The sole and exclusive remedy for breach of any warranty, expressed or implied, concerning Para System ’s products and the only obligation of Para Systems hereunder, shall be the repair or replacement of defective equipment, components, or parts; or, at Para System ’s option, refund[...]