Raypak RFSDV34RFPAU manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 27 pages
- 0.44 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Electric Heater
Raypak ASME Series
2 pages 0.09 mb -
Ventilation Hood
Raypak 330/331
16 pages 0.83 mb -
Boiler
Raypak Commercial Space Heating and Domestic Water
6 pages 0.56 mb -
Boiler
Raypak 133
2 pages 0.14 mb -
Swimming Pool Heater
Raypak Hi-Delta Commercial Swimming Pool Heater
1 pages 0.01 mb -
Water Heater
Raypak HI DELTA HD101 THRU 2342B
10 pages 0.46 mb -
Boiler
Raypak 1005
12 pages 2.46 mb -
Swimming Pool Heater
Raypak 2002
2 pages 0.38 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Raypak RFSDV34RFPAU. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Raypak RFSDV34RFPAU ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Raypak RFSDV34RFPAU décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Raypak RFSDV34RFPAU devrait contenir:
- informations sur les caractéristiques techniques du dispositif Raypak RFSDV34RFPAU
- nom du fabricant et année de fabrication Raypak RFSDV34RFPAU
- instructions d'utilisation, de réglage et d’entretien de l'équipement Raypak RFSDV34RFPAU
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Raypak RFSDV34RFPAU ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Raypak RFSDV34RFPAU et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Raypak en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Raypak RFSDV34RFPAU, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Raypak RFSDV34RFPAU, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Raypak RFSDV34RFPAU. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
RAYPAK VERMONT RFSDV34 FREESTANDING GAS LOG FIRE Installation and Operating Instructions For Models RFSDV34RFNAU (Natural Gas) & RFSDV34RFPAU (Propane) Page 1 of 27[...]
-
Page 2
CONTENTS Part 1: For Your Safety Part 2: Installation Instructions • Start Up Recommendations • Locating The Fireplace • Clearance to Combustibles • Fireplace Dimensions • Gas Specifications • Gas Inlet and Manifold Pressures • Preparation • Gas Line Installation Part 3: General Venting Information • Termination Clearances • Gen[...]
-
Page 3
Part 7: Conversion • Gas Type Conversion Instruction Part 8: Wiring Diagram • Wiring Diagram Part 9: Warranty Page 3 of 27[...]
-
Page 4
Part 1: For Your Safety For your safety do not operate this appliance before readi ng this instruction book. Warning: Improper installation, adjustm ent, alt eration, service or maintenance can cause injury or pr operty damage. For assistance or additional information cons ult with Raypak Australia, your Raypak distributor, qualified in staller or [...]
-
Page 5
Part 2: Installation Instructions This gas fireplace must be installed by a qualified installer in accordance with AS5601 and all relevant local building codes. For safe installation and operation please note the following: 1. This fireplace gives off high temperatures and should be located out of high traffic areas and away fr om furniture and dra[...]
-
Page 6
IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY Remove any plastic from trim parts before turning the appliance on. It is normal for fireplaces fabricated of steel to give o ff some expansion and/or contraction noises during t he start up or cool down cycle. It is not unusual for the Raypak Verm ont gas fireplace to produce some odour the first time[...]
-
Page 7
DIMENSION RFSDV34 A 667mm B 800mm C 492mm D 762mm E 254mm F 394mm G 114mm H 667mm I 333mm J 495mm K 162mm Page 7 of 27[...]
-
Page 8
Gas Specifications Model Gas Type Gas Control Min. MJ/h Input Max. MJ/h Input RFSDV34RFN Natural Radio Freq. 22 32 RFSDV34RFP Propane Radio Freq. 24 32 Gas Inlet and Burner Pressures Natural Gas ULPG Inlet Minimum 1.1 kPa 2.75 kPa Inlet Maximum 3.50 kPa 3.50 kPa Burner Pressure 0.87 kPa 2.50 kPa Preparation Warning: The use of wall paper adjacent t[...]
-
Page 9
Note: When making the gas connection to the appliance inlet fitting, hold the 10mm 3/8” BSP fitting with a s panner when tightening the gas inlet pipe compression nut. For Propane installations an approved gas regulator must be fitted in accordance with AS5601. Ensure copper tube meets the re quirements of Australian Standard AS1432 Type B. Note:[...]
-
Page 10
Part 3: General Flue Installation Underside of gas cowl must be at least 500mm above highest point of the roof. This appliance is approved for an installation with a maximum flue height of 12m and a minimum flue height of 3m. Suspend a plumbline from the ceiling to the centre of the flue spigot. Mark the centre of the flue spigot on the ceiling. Pr[...]
-
Page 11
Part 4: Operating Instructions NOTE: Carbon deposits maybe present on the glass and logs. This is normal and must be cleaned when the heater is serviced or the glass door is cleaned. Please refer to the Gener al Glass Information section on page 15. General Glass Information Warning: Only glass approved for use by Raypak Australia may be used for r[...]
-
Page 12
glass and causes lint, dust and other air-borne particles to cling. Initial paint curing may also deposit a slight film on the glass. Clean the glass two or three ti mes with a non-ammonia based household cleaner and warm water. (We recomm end gas fireplace glass cleaner.) After the initial cleaning, clean the glass two or three times during each o[...]
-
Page 13
Flame and Temperature Adjustment The appliance is fitted with the Honeywe ll Radio Frequency control valve and all adjustments are performed with t he use of a remote controller. See instructions packaged with the Remote Controller or refer to page 16 in this manual for operating instructions. Flame Appearance Periodically perform a visual check of[...]
-
Page 14
• DO NOT use any phone in the building. • IMMEDIATELY call you gas supplier from a neighbour’s phone or a mobile phone outside the build ing. Follow the gas suppliers instructions. • IF YOU CANNOT CONTACT YOU GAS SUPPLIER CALL THE FIRE BRIGADE. D. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will [...]
-
Page 15
13. For the RN/RP models turn the remote control ON/OFF switch to the ON position or set the thermostat to the desired setting. 14. Turn on electrical supply. To Turn Off the Heater 1. Turn the remote control ON/OFF switch to OFF or set the thermostat to the lowest setting. 2. Turn off power supply to the appliance if a service is to be performed. [...]
-
Page 16
remote control within 30 seconds. The LED will blink indicating the remote control will now work with the receiver valve. If the switch continues in the REMOTE position, the remote control will now control the main valve, flame modul ation level and fan control. 7. If the manual switch is in the LOCA L position, the valve will be at the highest fix[...]
-
Page 17
Fig. 7 Transmitter diagram Delay Timer Mode The shut off delay timer maximum setting is 2 hours and minimum setting is zero minutes. To change the timer le vel, press the timer key, then the arrow key. Each key press changes the setting by 10 minutes. Auto Mode In the AUTO mode, the r oom temperature, set te mperature, flame and fan levels will be [...]
-
Page 18
To Change Batteries 1. Remove cover on backside of the remote control. Install 3 AAA as shown on the cover and then re-attach the cover. 2. Once OPERATION steps 1 to 3 are completed, the receiver/valve and remote control are ready. Press any button on the remote control to initiate the recognition process between the receiver/valve and the remote c[...]
-
Page 19
If an error code 8 is observed while performing the testing, complete the following: 1. Confirm that the gas valve is not in the REMOTE mode. • If the valve is producing error code 8 while in the REMOTE mode, the valve is defective and should be replaced. • If the valve is producing error co de 8 while in the LOCAL mode, go to the next step. 2.[...]
-
Page 20
Troubleshooting the Gas Control System Comfort Valve System Control Seque nce of Operation with Remote Control Local Path On Path Auto Path Move switch from manual to remote. Press any key on remote control If the manual switch is set to remote, press the mode button to display ON. Does the remote control the main burner and fan? Does remote contro[...]
-
Page 21
Part 6 Replacement Parts List Insert replacement parts list and parts drawing here. Part 7 Conversion Instructions 1. Disconnect power to the unit and shut off the gas supply. 2. Remove the window frame a ssembly. (see the Window Frame Assembly section) 3. Carefully remove the logs . (ensure they are not hot) 4. Remove pilot asse mbly from bracket.[...]
-
Page 22
Part 8 Wiring Diagram A N 240V A C Te r m i n a l B l o c k Tr a n s f o r m er 240V AC - 110V AC 2A (50V A) Fuse - 3 Amp 240V A C 50 Hz Main Heater Supply Speed C on trol High Limit Fan RFSDV34 GAS L OG F I RE W I RI NG DI AGRAM Page 22 of 27[...]
-
Page 23
Page 23 of 27[...]
-
Page 24
Page 24 of 27[...]
-
Page 25
Page 25 of 27[...]
-
Page 26
Part 9 Warranty RAYPAK RFSDV34RFN & RFSDV34RFP FREESTANDING GAS LOG FIRE WARANTY - AUSTRALIA ONLY – Rheem Australia * w ill: a) Repair o r, if necessary replace any Ra ypak RFSDV34 Freestan ding Gas Log Fire, or b) Replace any comp onent (or, if necessary, arrange the installation of a Raypak Gas Log Fire, which falls within the Warranty Peri[...]
-
Page 27
RAYPAK MAJESTIC RFSDV34RFNAU AND RFSD34RFPAU WARRANTY - AUSTRALIA ONLY – WARRANTY CON DITIONS 1. This warranty is appli cable only to the RFSDV34RFN and the RFSDV34RFP gas log fires manufactured from August 2005 2. The gas log fire mu st be installed in accordance with the Raypa k installation instructions, supplied with the applianc e and in a c[...]