State Industries 740A manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 37 pages
- 1.11 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Water Heater
State Industries GPX-50 HXRT
2 pages 0.11 mb -
Water Heater
State Industries SBD71120NE
36 pages 0.53 mb -
Water Heater
State Industries GS6 50 YBVIT
32 pages 1.37 mb -
Water Heater
State Industries TPX-140-140
16 pages 0.22 mb -
Water Heater
State Industries SUF 130 THRU 500
49 pages 8.46 mb -
Water Heater
State Industries GS6 40 YBRT Series 200
36 pages 2.26 mb -
Water Heater
State Industries SBL85 275NE(A)
52 pages 5.5 mb -
Water Heater
State Industries GP6 50
40 pages 4.34 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation State Industries 740A. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel State Industries 740A ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation State Industries 740A décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation State Industries 740A devrait contenir:
- informations sur les caractéristiques techniques du dispositif State Industries 740A
- nom du fabricant et année de fabrication State Industries 740A
- instructions d'utilisation, de réglage et d’entretien de l'équipement State Industries 740A
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage State Industries 740A ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles State Industries 740A et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service State Industries en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées State Industries 740A, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif State Industries 740A, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation State Industries 740A. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
1 MODELS GPG/GPV -540A, 650A AND 740A COMMERCIAL GAS, GLASS-LINED, T ANK-TYPE LOW NOx W A TER HEA TER 1 95047 - 00 1 CAUTION TEXT IN BLACK BOLD TYPE OR UNDERLINED CONT AINS INFORMA TION RELA TIVE TO YOUR SAFETY . PLEASE READ THOROUGHL Y BEFORE INST ALLING AND USING THIS APPLIANCE . ASHLAND CITY , TN www .statewaterheaters.com PLACE THESE INSTRUCTIO[...]
-
Page 2
2 FOREWORD The design of the GPG 540A through 740A models complies with ANSI Z21.10.3/CSA 4.3 as an automatic circulating tank and an automatic instantaneous type heater . The GPV 540A through 740A models are designed for sidewall venting and direct venting applications and are certied under UL 795. Detailed installation diagrams are found in th[...]
-
Page 3
3 are different from natural gas models. A natural gas heater will not function safely on LP gas and no attempt should be made to convert a heater from natural gas to LP gas. GPG/ GPV -540A, 650A & 740A models are not available for use ?[...]
-
Page 4
4 and sodium chloride (water softener salt), waxes, and process chemicals are typical compounds which are potentially corrosive. Do not store products of this sort near the heater . Also, air which is brought in contact with the heater should no contain any of these chemicals. If necessary , uncontaminated air should be obtained from remote or outs[...]
-
Page 5
5 Continued manual resetting of high limit control, preceded by higher than usual water temperature is evidence of high limit switch operation. The following are possible reasons for high limit switch operation. • A malfunction in the thermostatic controls would allow the gas valve to remain open causing water temperature to exceed the thermostat[...]
-
Page 6
6 Units, which are to be installed on combustible ooring, must be supported by a full layer of hollow concrete blocks, from 8” (203.2 mm) to 12” (304.8 mm) thick and extending 12” (304.8 mm) minimum beyond the heater in all directions. The concrete blocks must provide an unbroken concrete surface under the heater with the hollows running c[...]
-
Page 7
7 Heater must be protected from freezing downdrafts during shutdown periods. The GPG 540A, 650A and 750A water heater are classied as a cate gory I appli ance (non -pos itiv e vent press ure, non-con dens ing) when installed with the supplied barometric draft control assembly in a vertical vent installation. The GPV 540A through 740A heater is c[...]
-
Page 8
8 Refer to T able 2 for limitations of venting system design for horizontal venting. T ABLE 2 GPV -540A-740A Flue Outlet Dia. (Inches/mm) 9” (228.6) Flue Reducer 9” x 8” Dimensions -Supplied (Inches/mm) 228.6 x 203.2 Minimum Outlet V ent Dia. (Inches/mm) 8” (203.2) Maximum Number 90° 4 Of Elbows 45° 8 Maximum T otal V ent System 75 Length[...]
-
Page 9
9 DIRECT VENTING - FOR GPV MODELS All exhaust vent terminal, ue reducer , and intake vent terminal are suppl ied with any unit intende d for direc t venting . These parts must be installed without alteration. This heater is category III appliance when used in a direct vent application. All national and local codes pertaining to the installation [...]
-
Page 10
10 1. Shall be located not less than 12” (304.8 mm) above grade. 2. Shall be located not less than 3 (.9144 m) feet horizontally from and not less than 3 feet (.9144 m) below an exhaust vent terminal. 3. Shall not be located directly above an exhaust terminal. 4. Shall be located 12” (304.8 mm) above the snow line in geographical areas where sn[...]
-
Page 11
11 5. Attach a properly sized length of Selkirk Metalbestos model PS or model G venting to the exhaust vent adapter using the inner vee bands, see Figures 7 and 7B on page 10. 6. Fill the gro ov es in both inne r vee bands with high -t emp sili con e sealant, Dow Corning 736 or equivalent. 7. Position the inner vee bands around the inner pipe an[...]
-
Page 12
12 T ABLE 9A MAXIMUM CAP ACITY OF PIPE IN CUBIC FEET OF GAS PER HOUR (Based upon a Pressure Drop of 0.5 inch W ater Column LENGTH IN Nominal Iron Pipe Sizes, Millimeters ME[...]
-
Page 13
13 ROBERTSHA W ® 7000 DERHC GAS CONTROL V AL VE FIGURE 10. W A TER LINE CONNECTIONS Following are detailed installation diagrams for typical methods of application for the water heaters. The water heater may be installed by itself, or with a separate storage tank, on both single and two-temperature systems. When used with a separate storage tank, [...]
-
Page 14
14 INST ALLA TION DIAGRAMS ONE TEMPERA TURE - ONE HEA TER VERTICAL STORAGE T ANK FORCED CIRCULA TION WITH OR WITHOUT BUILDING RECIRCULA TION DANGER IF BUILDING COLD W A TER SUPPL Y HAS A BACKFLOW PREVENTER, CHECK V AL VE OR W A TER METER WITH CHECK V AL VE, PROVISIONS FOR THER MAL EX P ANSION OF W A TER IN THE HOT W A TER SYSTEM MUST BE PROVIDED. N[...]
-
Page 15
15 TWO TEMPERA TURE - ONE HEA TER HIGH TEMPERA TURE WITH OR WITHOUT BUILDING RECIRCULA TION TWO TEMPERA TURE - TWO HEA TERS HIGH TEMPERA TURE WITH OR WITHOUT BUILDING RECIRCULA TION *PIPE RELIEF V AL VE TO OPEN DRAIN N O T E : IF TEMPERED W A TER IS RECIRCULA TED, RETURN LINE SHOULD BE CONNECTED A T POINT “A”. INST ALL IN ACCORDANCE WITH LOCAL [...]
-
Page 16
16 CAUTION: IF BUILDING COLD WA TER SUPPL Y HAS A BACKFLOW PREVENTER, CHECK V AL VE OR WA TER METER WITH CHECK V AL VE, PROVISIONS FOR THERMAL EXP ANSION OF W A TER IN THE HOT W A TER SYSTEM MUST BE PROVIDED. TWO TEMPERA TURE - THREE HEA TERS (TWO PRE-HEA TERS/ONE BOOSTER) WITH OR WITHOUT BUILDING RECIRCULA TION TWO TEMPERA TURE - TWO HEA TERS (ONE[...]
-
Page 17
17 TWO TEMPERA TURE - ONE HEA TER HIGH TEMPERA TURE WITH RECIRCULA TION OF SANITIZING LOOP CAUTION: IF BUILDING COLD WA TER SUPPL Y HAS A BACKFLOW PREVENTER, CHECK V AL VE OR WA TER METER WITH CHECK V AL VE, PROVIS IONS FOR THERMAL EXP ANSION OF WA TER IN THE HOT WA TER SYSTEM MUST BE PROVIDED. DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE TEM[...]
-
Page 18
18 MANIFOLD KITS Precision cut type “L” all copper State manifold kits assure water ow balan ce of all units . Wit hou t this balan ce, the full water heati ng and storage potential of the system cannot be achieved. Plus, the units with the higher water ow may have a shortened life. Unions shown in piping diagrams are not included in the [...]
-
Page 19
19 HEA TER WIRING IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WIT H 1 05 °C WIRE O R I TS EQUI V AL EN T , E XC EPT I N TH E BURNER HOUSING USE 200°C WIRE. The power burner is wired to the heater as shown in Figure 1 1 for GPG models and Figure 12 for GPV models. The model and rating plate prov[...]
-
Page 20
20 FIGURE 1 1.[...]
-
Page 21
21 FIGURE 12.[...]
-
Page 22
22 FOR YOUR SAFETY READ BEFORE LIGHTING 1. Remove thermostat control cover . 2. Set thermostat to lowest setting. 3. Turn burner switch to “OFF”. W ARNING: expl[...]
-
Page 23
23 DANGER TH IS W A TE R H E A TE R I S E QUI P PE D W ITH AN AD JUS T AB LE TH ER MO ST A T T O C ON TR OL W A TER TEM PE RA TURE . HO T W A TER TEMPERA TURES REQUIRED FOR AUTOMA TIC DISHW ASHER AND LAUNDRY USE CAN CAUSE SCALD BURNS RE SUL TI N G IN S ERI OU S PER SON AL IN JU R Y AN D /O R DE A TH . T HE TE M PE RA TU R E A T WH IC H IN JU R Y O [...]
-
Page 24
24 1. Check gas line pressure with a manometer . Set initial gas line pressure at 9-10” w .c. before turning the heater “ON”. Read gas line pressure and gas manifold pressure when the heater main gas is “ON”. Adjust gas line regulator setting if the gas line pressure drops below 8” w .c. when heater main gas is “ON”. Check heater ga[...]
-
Page 25
25 PREMIX LOW NOx BURNER - EXPLODED VIEW FOR GPG MODELS FIGURE 13.[...]
-
Page 26
26 PREMIX LOW NOx BURNER - EXPLODED VIEW FOR GPV MODELS FIGURE 14.[...]
-
Page 27
27 GENERAL INFORMA TION POWER BURNER The initial start-up procedure of the gas power burner is provided on page 18 thru 21. Refer to Figure 12, burner exploded view for burner components location. The sequence of operation of the power burner is provided on page 15. For detailed Power Burner Operation, Maintenance and T roubleshooting refer to the [...]
-
Page 28
28 DRAINING The heater must be drained if it is to be shut down and exposed to freezing temperatures. Maintenance and service procedures may also require draining the heater . 1. T urn off the heater electrical disconnect switch. 2. Close the cold water inlet valve to heater . 3. Open a nearby hot water faucet to vent the system. 4. Open the heater[...]
-
Page 29
29 A B O V E A L L, D O N O T P L U G T H E T E MP E RATU RE AN D PRESSURE RELIEF V AL VE. THIS IS NOT A SOLUTION AND CAN CREA TE A HAZARDOUS SITUA TION. CIRCULA TING PUMP The water heating system may include a circulating pump. Where used, it should be lubricated as directed by the circulator manufacturer . LOW EMISSION POWER BURNER KEEP THE AREA [...]
-
Page 30
30 2. Check the fuses. • The electrical disconnect switch usually contains fuses. 3. The capacity of the heater may have been exceeded by a large demand for hot water . 4. Colder incoming water temperature will lengthen the time required to heat water to the desired temperature. • If the heater was installed when incoming water temperature was [...]
-
Page 31
31 20 , an d the troubleshooting section of burner manual before continuing. Make sure the appliance is connected to a 120 V ac power supply , burne r switch is “ON” and manual gas valve is in the “ON” posit ion, and all electrical connections are secure before continuing to troubleshoot this appliance. MOTOR WILL NOT RUN 1. Conrm 120 V [...]
-
Page 32
32 5. As soon as the pilot gas valve is energized, check for the burner pilot flame through the burner peek-hole. If the pilot flame is established inside the burner , then proceed to Step 6. • T urn the burner switch to “OFF” position for at least one minute to reset the heater . • Check for 24V between “PV” terminal and “MV/PV” te[...]
-
Page 33
33 Model GPG/GPV Limited W arranty Factory Start-Up is required for activat ing warran ty and assuring maximu m operatin g performa nce. Contact your local sales representa tive or Authoriz ed Start-Up Agent to arrange a FREE Certied Start-Up. State Industries, Inc., the warrantor , extends the following LIMITED WARRANTY to the owner of this wat[...]
-
Page 34
34 COMMERCIAL T ANK TYPE W A TER HEA TER REPLACEMENT P ARTS LIST MODELS GPG/GPV -540A THRU 740A SERIES 104 ST A TE W A TER HEA TERS 500 Lindahl Parkway , Ashland City , TN 37015 website: www .statewaterheaters.com GPV VENT [...]
-
Page 35
35 1......... Anode, Plug ...................................................................... 9003892005(4) ............ 9003892005(4) ............. 9003892005(4) 2......... Bafe, Flue .......................................................................9006832005(24) .......... 9006832005(24) ........... 9006832005(24) 3......... V alve, R[...]
-
Page 36
36 GPG BURNER ASSEMBL Y (FOR ALL P ARTS ON THIS BURNER CONT ACT : W ayne Combustion Systems, 801 Glasgow Ave, Fort W ayne IN 46803)[...]
-
Page 37
37 500 Lindahl Parkway , Ashland City , TN 37015 Phone: 800-821-2017 Fax: 800-644-9306 www .statewaterheaters.com[...]