Stovax Open Log Burning Convector Fireboxes manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 32 pages
- 6.39 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Indoor Fireplace
Stovax 8627 MA
28 pages 0.51 mb -
Indoor Fireplace
Stovax 8545LUC, P8545LUC
27 pages 3.2 mb -
Indoor Fireplace
Stovax Open Log Burning Convector Fireboxes
32 pages 6.39 mb -
Indoor Fireplace
Stovax AR0887
26 pages 0.46 mb -
Indoor Fireplace
Stovax P8564
28 pages 1.03 mb -
Indoor Fireplace
Stovax GAZCO Linea Balanced Flue Convector Fire
25 pages 0.86 mb -
Indoor Fireplace
Stovax 8517-P8517
28 pages 0.68 mb -
Indoor Fireplace
Stovax 8904
2 pages 0.14 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Stovax Open Log Burning Convector Fireboxes. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Stovax Open Log Burning Convector Fireboxes ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Stovax Open Log Burning Convector Fireboxes décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Stovax Open Log Burning Convector Fireboxes devrait contenir:
- informations sur les caractéristiques techniques du dispositif Stovax Open Log Burning Convector Fireboxes
- nom du fabricant et année de fabrication Stovax Open Log Burning Convector Fireboxes
- instructions d'utilisation, de réglage et d’entretien de l'équipement Stovax Open Log Burning Convector Fireboxes
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Stovax Open Log Burning Convector Fireboxes ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Stovax Open Log Burning Convector Fireboxes et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Stovax en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Stovax Open Log Burning Convector Fireboxes, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Stovax Open Log Burning Convector Fireboxes, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Stovax Open Log Burning Convector Fireboxes. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Riva Open Log Burning Convector Fireboxes 16", 22", 24", 26" & 28" Standard and Low models PM219 - Issue 1 (June 2008) Instructions for Use, Installation and Servicing For use in Great Britain and Republic of Ireland. IMPORTANT This appliance will become hot whilst in operation, it is therefore recommended that a suitab[...]
-
Page 2
2 COVERING THE FOLLOWING MODELS: 8610/8611/8604/8605/8606/8607/8608/8609/8673 COMMISSIONING 27 MAINTENANCE & SERVICING 28 Annual Service 28 Removal of Flue Damper 28 SERVICE RECORDS 30 EC DECLARATION OF CONFORMITY 31 APPLIANCE COMMISSIONING CHECKLIST 3 USER INSTRUCTIONS 4 General Points 4 Using the Appliance for the first time 5 Recommended Fue[...]
-
Page 3
3 APPLIANCE COMMISSIONING CHECKLIST Dealer appliance was purchased from Name: ..................................................................................................................................................................................... Address: .................................................................................[...]
-
Page 4
4 1. GENERAL POINTS 1.1 Before use of this appliance please read these instructions fully. 1.2 All local regulations, including those referring to national and European Standards need to be complied with when installing the appliance. 1.3 Only use for domestic heating in accordance with these operating instructions. 1.4 You must burn only approved [...]
-
Page 5
5 WARNING Properly installed operated and maintained this appliance will not emit fumes into the room. Occasional fumes from de-ashing and refuelling may occur. Persistent fume emission is potentially dangerous and must not be tolerated. If fume emission does persist: •Open doors and windowsto ventilate the room ?[...]
-
Page 6
6 4. LIGHTING THE APPLIANCE 4.1 For best results: •Setdamper contro ls,SeeDia gram 6 PR8068 Open Close •Place firelighters or paperand dry kindling woodon the base of the firebox •Light the paper or firelighters,See Diagram 7 •Add larger pie[...]
-
Page 7
7 The multi-fuel kit is fitted as shown: Note that this kit must only be used with the appropriate Steel frame, Diagram 10. PR8070 •Set Primary Air Control , see Diagram 11 PR8071 - Closed PR8071 - Open PR8071 - Closed PR8071 - Open *Note: Frame not shown for clarity OPEN (+) (-) CLOSED The Primary Air Control must be either fully open [...]
-
Page 8
8 — Smoke and small flames — Short life span for grate 6.3 Flue Draught The chimney has two main functions: 1) To safely remove the smoke, gases and fumes from the house. 2) To provide a sufficient amount of draught (suction) in the appliance ensuring the fire keeps burning. Draught is caused by the rising hot air in the chimney when the applia[...]
-
Page 9
PR8074 Poker 7.3 Remove components carefully. Heat can remain long after use, See Diagram 16 PR8076 PR8075 Multi-fuel Kit Cast Basket Ashpan Ashpan Grate Damper/ Multi-fuel tool Where a steel frame is fitted on the multi-fuel kit version: •Remove the logbar andbottom frame plate before removing the grates (Using the too[...]
-
Page 10
10 13. CHIMNEY SWEEPING 13.1 To maintain safe and efficient use of the appliance the chimney/flue must be inspected and swept at least once a year by a qualified chimney sweep.* If the appliance is used continuously throughout the year or it is used to burn wood or smokeless fuel, more frequent sweeping is recommended. The best time to have the chi[...]
-
Page 11
RIVA OPEN TECHNICAL SPECIFICATION 1. STANDARD FEATURES • DamperControl • Primaryair (under grate air for fullmulti-fuel use)* * Multi-fuel kits 8705, 8710, 8720 only 2. PACKING LIST • Instructions • Guaranteecard • Pairof gloves • Damper/Multi-fuelgrate Tool • Poker Model [...]
-
Page 12
TECHNICAL SPECIFICATION 16" Low 22" Low 24" Low 26" Low 28" A 474 474 624 624 674 674 724 724 774 B 592 542 652 592 652 592 652 592 652 C 348 348 348 348 348 348 348 348 348 D 550 500 610 550 610 550 610 550 610 E 400 400 550 550 600 600 650 650 700 F 489 489 639 639 689 689 739 739 789 G 595 545 655 595 655 595 655 595 655[...]
-
Page 13
13 16" 22" 24" 26" 28" Profil Brass - standard height 8633 8635 8637 8639 8626 Profil Brass - low lintel 8674 8636 8638 8640 - Profil Brushed Stainless - standard height 8633BS 8635BS 8637BS 8639 8626BS Profil Brushed Stainless - low lintel 8674BS 8636BS 8638BS 8640BS - 16" 22" 24" 26" 28" Steel Fra[...]
-
Page 14
14 1. FLUE OR CHIMNEY 1.1 The flue or chimney system must be in good condition. It must be inspected by a competent person and passed for use with the appliance before installation Products of combustion entering the room can cause serious health risks. 1.2 You must check the following: — The construction of the masonry chimneys, flue block chimn[...]
-
Page 15
SITE REQUIREMENTS 15 3.1 The appliance must stand on a non-combustible constructional hearth which is at least 125mm thick with the minimum dimensions as shown in diagram. If it is to be fitted in a raised setting consideration may need to be given to extending the depth of the hearth to safely containing any falling logs or embers. 3.2 The buildin[...]
-
Page 16
SITE REQUIREMENTS 16 4. BUILDERS OPENING To make installation easier make the opening larger than the minimum requirements where possible. B A FRONT C Appliance Dim A Dim B Dim C 16" 420 560 360 22" 570 620 360 24" 620 620 360 26" 670 620 360 28" 720 620 360 Appliance Dim A Dim B Dim C 16" 420 510 360 22" 570 560 [...]
-
Page 17
PRE-INSTALLATION CHECKS Model Flue/Chimney Size Without liner system (round) minimum dimension (diameter.) mm 200 200 200 200 200 inch 8 8 8 8 8 Without liner system (square) minimum dimension mm 185 185 185 185 185 inch 7 1/4 7 1/4 7 1/4 7 1/4 7 1/4 Liner or factory made system (diameter.) installed in accordance with manufacturers instructions mm[...]
-
Page 18
2.2 Extractor fans or cooker hoods should not be placed in the same room or space as the appliance. 2.3 If any of these checks reveal problems do not proceed with the fitting of the appliance until they have been rectified. 2.1 Open appliances require additional ventilation to comply with the requirements of the Building Regulations. This should be[...]
-
Page 19
LEGAL REQUIREMENTS Before installation of this product please read these instructions fully. It is very important to understand the requirements of the national Building Regulations* and standards**, along with any local regulations and working practices that may apply. Should any conflict occur between these instructions and these regulations then[...]
-
Page 20
3 PR8079 2A. FITTING OF FUEL KITS - LOG 2.1 Install the relevant fuel box . 4 PR8080 2.2 Fit the Log Retainer ( Holyrood , Castle , Portcullis ), Diagram 5. Note: the Holyrood retainer has a specially curved log- burning tray. 5 PR8081 Back of Log Retainer Retaining clips • Fit retaining clips over the front lip of Log Box 2.3 Fit the Contemporar[...]
-
Page 21
21 INSTALLATION INSTRUCTIONS 2.6 Or • Fit a Multi-fuel box , Diagram 9 This must be done with the frame removed, see Section 3 9 PR8084 2.7 Fit a Contemporary Multi-fuel Log bar , Diagram 10 Slide into channels in the front of the Multi-fuel Box and cutout in grates. The removable frame base is not shown for clarity but must be in pl[...]
-
Page 22
22 INSTALLATION INSTRUCTIONS 14 PR8087 3.3 Steel Square/Rectangular Frames •Drill 4 Ø 7.5 holes in required positions, 16" Diagram 12, 22" Diagram 15, 26" Diagram 16 A 1:1 scale drilling template is provided with the frame to assist in correctly locating the holes. 22" Frame Drilling Template 15 464 584 30 30 Ø [...]
-
Page 23
20 PR8090 Air deflector not shown for clarity 3A. REMOVABLE BOTTOM FRAME PLATE 3A.1 The steel frames have a removable bottom plate to allow easy access to the space below for Ash Removal with a vacuum cleaner nozzle. •Fit the removable bottom framesection by tilting atan angle, Diagram 21 21 PR8091 - 1 Removable [...]
-
Page 24
INSTALLATION INSTRUCTIONS 24 4. FITTING AN OPTIONAL FLUE GATHER 4.1 Fitting Of Optional Flue Gather 16" 22" 24" 26" 28" Flue gather - standard (central) - 8658 8659 8660 8661 Flue gather - staggered (offset) - 8663 8664 8665 8662 • Place the appropriate flue gather on top of the convector box, See Diagram 27 27 PR8093 [...]
-
Page 25
25 INSTALLATION INSTRUCTIONS •Position the back andside cast firebricks onthe grate behind the raised ribs, See Diagram 30 30 •Slide the ashpan (G)under the grate •Hookthe front bars (H)onto the fireplace andslide the ashpan cover (F) into position below th[...]
-
Page 26
26 INSTALLATION INSTRUCTIONS 8. FITTING AND REMOVAL OF TRADITIONAL SPARKGUARD 16" 22" 24" 26" 28" Traditional clip-in spark guard -std 8690 8691 8692 8693 8694 Traditional clip-in spark guard -low lintel 8695 8696 8697 8698 - 33 PR8095 F eet C onvector box channels • Fit the sparkguard feet to the frame using fixings supp[...]
-
Page 27
COMMISSIONING 27 COMMISSIONING 1.1 To commission: • Check the soundness of seals, castings and joints (Convector box flange and flue gather) •C heck the operation of the air controls 1.2 Now carry out a final smoke draw test: •First warming the flue witha blowlamp, or similar,for about 10 min[...]
-
Page 28
28 1. ANNUAL SERVICE 1.1 Before the start of the heating season strip, inspect and clean the appliance as detailed: •Allow appliance to cool •Remove all of thefollowing internal parts;damper system, complete log box/multi-fuel box/cast basket •Remove any frames, Installation Se[...]
-
Page 29
29 NOTES[...]
-
Page 30
30 SERVICE RECORDS 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:........................................................................................ Dealer's Stamp/HETAS Registration Num[...]
-
Page 31
31[...]
-
Page 32
Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474011 Fax: (01392) 219932 E-mail: info@stovax.com www.stovax.com[...]