Subaru Robin Power Products RGV6100 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 82 pages
- 1.9 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Portable Generator
Subaru Robin Power Products DY35
59 pages 3.03 mb -
Portable Generator
Subaru Robin Power Products RGB2510
44 pages 0.71 mb -
Portable Generator
Subaru Robin Power Products RGX405, RGX405D
75 pages 3.76 mb -
Portable Generator
Subaru Robin Power Products RGD3310
39 pages 0.9 mb -
Portable Generator
Subaru Robin Power Products RGx4800
7 pages 21.19 mb -
Portable Generator
Subaru Robin Power Products RGX1810
40 pages 2.21 mb -
Portable Generator
Subaru Robin Power Products EC17D
43 pages 1.13 mb -
Portable Generator
Subaru Robin Power Products EH65
24 pages 0.82 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Subaru Robin Power Products RGV6100. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Subaru Robin Power Products RGV6100 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Subaru Robin Power Products RGV6100 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Subaru Robin Power Products RGV6100 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Subaru Robin Power Products RGV6100
- nom du fabricant et année de fabrication Subaru Robin Power Products RGV6100
- instructions d'utilisation, de réglage et d’entretien de l'équipement Subaru Robin Power Products RGV6100
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Subaru Robin Power Products RGV6100 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Subaru Robin Power Products RGV6100 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Subaru Robin Power Products en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Subaru Robin Power Products RGV6100, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Subaru Robin Power Products RGV6100, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Subaru Robin Power Products RGV6100. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
PUB-GS1277 Re v . 1 / 04 SERVICE MANUAL RGV2800, RGV4100, RGV6100 Models Generators[...]
-
Page 2
CONTENTS Section Title Page 1. SPECIFICA TIONS ....................................................................................................... 1 2. PERFOMANCE CURVES ........................................................................................... 3 3. FEA TURES .....................................................................[...]
-
Page 3
Section Title Page 9-4 ST A T OR .............................................................................................................. 33 9-5 ROTOR ASSEMBL Y ........................................................................................... 34 9-6 CONDENSER ..........................................................................[...]
-
Page 4
- 1 - 1. SPECIFICA TIONS * Electric starter motor is available as option. ENGINE AL TERNA TOR l e d o M0 0 8 2 V G R0 0 1 4 V G R e p y T e s a h P e l g n i S , e l o P - 2 , g n i t i c x E f l e S , s s e l h s u r B C A y c n e u q e r F z H 0 6 t u p t u O m u m i x a MW 0 0 8 2W 0 0 1 4 t u p t u O d e t a RW 0 0 3 2W 0 0 6 3 e g a t l o V d [...]
-
Page 5
- 2 - * Electric starter motor is available as option. ENGINE AL TERNA TOR l e d o M0 0 1 6 V G R e p y T e s a h P e l g n i S , e l o P - 2 , g n i t i c x E f l e S , s s e l h s u r B C A y c n e u q e r Fz H 0 6 t u p t u O m u m i x a MW 0 0 8 5 t u p t u O d e t a RW 0 0 8 4 e g a t l o V d e t a R t n e r r u C V 0 4 2 / V 0 2 1A 0 2 / A 0 [...]
-
Page 6
- 3 - 2. PERFOMANCE CUR VES Hz ( Hz ) ( V ) ( 125 ) 63 250 ( 120 ) 240 ( 115 ) 230 ( 110 ) 220 62 61 60 0 1/2 4/4 Load Rated 230V/115V[...]
-
Page 7
- 4 - DC OUTPUT DC V oltage ................. 12 V DC Ampere ................ 8.3 A DC output ................... 100 W The voltage curve shown in the left indicates the characteristic of DC output when charging a battery . The voltage may be decreased by 20% when the resistance load is applied. NOTE : It is possible to use both DC and AC outputs s[...]
-
Page 8
- 5 - 3. FEA TURES 3-1 BRUSHLESS AL TERNA T OR Newly developed brushless alternator eliminates troublesome brush maintenance. 3-2 CONDENSER TYPE VOL T AGE REGULA T OR A trouble free condenser type voltage regulator ensures a stable voltage under all working conditions. 3-3 OIL SENSOR Oil sensor automatically shuts off the engine whenever the oil le[...]
-
Page 9
- 6 - 3-9 MINIMAL MAINTENANCE * A brushless alternator release the operator from periodical brush maintenance. * A trouble free condenser type voltage regulator . * A drip-proof alternator design. * No-fuse circuit breakers. * An electronic pointless ignition system. * A dust-proof cyclone air cleaner . 3-10 LONG-LIFE DURABILITY The heavy-duty 4 st[...]
-
Page 10
- 7 - 4. GENERAL DESCRIPTION 4-1 EXTERNAL VIEW FUEL GAUGE VOLTMETER AC RECEPTACLE EARTH TERMINAL SPARK PLUG NO-FUSE BREAKER OIL DRAIN PLUG OILGAUGE (OIL FILLER) ENGINE SWITCH CHOKE KNOB AIR CLEANER RECOIL STARTER OIL SENSOR TANK CAP MUFFLER FULL POWER SWITCH DC CIRCUIT BREAKER DC OUTPUT TERMINAL IDEL CONTROL SWITCH ENGINE EMISSION LABEL[...]
-
Page 11
- 8 - 4-2 CONTROL P ANEL * RGV2800 : U.S.A., 60Hz-120V [NEMA RECEPT ACLE] * RGV4100 : U.S.A., 60Hz-120V/240V [NEMA RECEPT ACLE] ENGINE SWITCH AC OUTPUT AC MAX 20A V METER DC OUTPUT AC BREAKER DC BREAKER ON OFF ON OFF DC 12V-8.3A BATTERY CHARGE ONLY TEST TEST RESET RESET FULL POWER SWITCH AC 120V AC 120V / 240V ENGINE SWITCH 120V 120V 240V V METER D[...]
-
Page 12
- 9 - * RGV6100 : U.S.A., 60Hz-120V/240V [NEMA RECEPT ACLE] 4-3 LOCA TION of SERIAL NUMBER and SPECIFICA TION NUMBER Serial number and specification number are stamped on the LABEL (MODEL NAME) stuck on the side wall of control box. NOTE : Always specify these numbers when inquiring about the generator or ordering spare parts in order to get correc[...]
-
Page 13
- 10 - 5. CONSTRUCTION AND FUNCTION 5-1 CONSTRUCTION 5-2 FUNCTION 5-2-1 ST A TOR The stator consists of a laminated silicon steel sheet core, a main coil and a condenser coil which are wound in the core slots. The condenser coil excites the rotor field coil which generates AC voltage in the main coil. Fig. 5 -2 Fig. 5 -1 END COVER STATOR COVER STAT[...]
-
Page 14
- 11 - 5-2-2 CONDENSER One or two condensers are installed in the con- trol box and are connected to the condenser coil of the stator . These condensers and condenser coil regulate the output voltage. 5-2-3 ROTOR The rotor consists of a laminated silicon steel sheet core and a field coil which is wound over the core. DC current in the field coil ma[...]
-
Page 15
- 12 - 5-2-4 NO-FUSE BREAKER The no-fuse breaker protects the generator from getting damage by overloading or short circuit in the appliance. T able 5-1 shows the capacity of no-fuse breaker by each spec. and their object of protection. 5-2-5 DC CIRCUIT BREAKER The 10 ampere DC circuit breaker mounted on the control panel protects whole DC circuit [...]
-
Page 16
- 13 - NOTE : If your generator has receptacles pecu- liar to your country , T able 5-2 does not apply . Caution : The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit Interrupter). GFCI shuts off the output current from the duplex 120V receptacle when a ground fault occurs in the generator or the appliance. Please note that othe[...]
-
Page 17
- 14 - 5-2-8 CONNECTING TO DOMESTIC CIRCUITS (HOUSE WIRING) W ARNING : All Robin generators are a neutral ungrounded type. If a generator is to be connected to residential or commercial power lines, such as a stand-by power source during power outage, all connections must be made by a licensed electrician. Failure in connection may result in death,[...]
-
Page 18
- 15 - Utility high line Meter box Generator House circuit breaker XW Y X ( X )( Y ) ( G ) ( W ) WY Transfer switch 240V 4P- Receptacle 120V appliance 120V appliance 240V appliance Fig. 5 -1 0 (c) Operating the generator . Set the full power switch to 120V/ 240V side. T urn the house AC breaker off before starting the generator . Start the generato[...]
-
Page 19
- 16 - 5-3 GENERA T OR OPERA TION 5-3-1 GENERA TION of NO-LOAD VOL T AGE (1) When the generator starts running, the permanent magnet built-in to the rotor generates 3 to 6V of AC voltage in the main coil and condenser coil wound on the stator . (2) As one or two condensers are connected to the condenser coil, the small voltage at the condenser coil[...]
-
Page 20
- 17 - 5-3-3 FULL POWER SWITCH (Dual V oltage T ype) The full power switch is provided for the dual voltage type to take out the full rated power from one receptacle in each voltage. Fig. 5 -1 2 Fig. 5 -1 3 Fig. 5 -1 4 T able. 5-3 h c t i w S n o i t i s o P E G A T L O V R E W O L E L C A T P E C E R E G A T L O V R E H G I H E L C A T P E C E R V[...]
-
Page 21
- 18 - T wo main coils are wound over stator core. Each main coil outputs half the rated power at the lower voltage (120V). These main coils are wound to be in the same phase. The full power switch reconnects these main coils in parallel or in series. Fig. 5-12 shows a circuit diagram. When the full power switch is set for single lower voltage indi[...]
-
Page 22
- 19 - 5-4 OIL SENSOR 5-4-1 DESCRIPTION * The oil sensor mainly functions to detect posi- tion of the surface of engine oil in the crankcase of engines for general use and to stop the en- gine automatically when the oil level goes down below the lower limit specified. This prevents sei- zure of engine from occurring due to insufficient amount of oi[...]
-
Page 23
- 20 - [Judgement of oil level] When sufficient oil is in the crankcase, both of inner and outer electrodes are immersed in the oil through which current flows across the electrodes. The sensor judges that oil in the crankcase is suf ficient. When oil level goes down and the inner electrode is exposed to the air due to consumption of oil, no curren[...]
-
Page 24
- 21 - 2 Detection circuit ..... This detects quantity of oil, sufficient or not, according to dif ference of electric resistance across inner and outer electrodes. 3 Delay circuit ........... This his prevents the sensor from making an unnecessary stop of the engine by momentary lowering of the oil level due to the engine being slanted or affected[...]
-
Page 25
- 22 - 6. SAFETY PRECAUTIONS 1. Use extreme caution near fuel. A constant danger of explosion or fire exists. Do not fill the fuel tank while the engine is running. Do not smoke or use open flame near the fuel tank. Be careful not to spill fuel when refueling. If spilt, wipe it and let dry before starting the engine. 2. Do not place inflammable mat[...]
-
Page 26
- 23 - 7. RANGE OF APPLICA TIONS Generally , the power rating of an electrical appliance indicates the amount of work that can be done by it. The electric power required for operating an electrical appliance is not always equal to the output watt- age of the appliance. The electrical appliances generally have a label showing their rated voltage, fr[...]
-
Page 27
- 24 - (5) Appliances without any indication as to power consumption Some appliances have no indication as to power consumption; but instead the work load (output) is indicated. In such a case, power consumption is to be worked out according to the numerical formula mentioned below . Efficiencies of some electrical appliances are as follows : Singl[...]
-
Page 28
- 25 - NOTES : Wiring between generator and electrical appliances 1. Allowable current of cable Use a cable with an allowable current that is higher than the rated input current of the load (electrical appliance). If the input current is higher than the allowable current of the cable used, the cable will become excessively heated and deteriorate th[...]
-
Page 29
- 26 - 8. MEASURING PROCEDURES 8-1 MEASURING INSTRUMENTS 8-1-1 “Dr . ROBIN” GENERA TOR TESTER The “Dr . Robin” generator tester is exclusively designed for fast, easy diagnosis and repair of Robin generators. The “Dr . Robin” has the follow- ing features : (1) Functions of voltmeter , frequency meter , megger tester , capacitance meter [...]
-
Page 30
- 27 - 8-1-2 INSTRUMENTS (1) VOL TMETER AC voltmeter is necessary . The approximate AC voltage ranges of the voltmeters to be used for various types of generators are as follows: 0 to 150V : T ype with an output voltage of 1 10 or 120V 0 to 300V : T ype with an output voltage of 220, 230 or 240V 0 to 150V , 0 to 330V : Dual voltage type (2) AMMETER[...]
-
Page 31
- 28 - (4) CIRCUIT TESTER Used for measuring resistance, etc. (5) MEGGER TESTER Used for measuring generator insulation re- sistance. Select one with testing voltage range of 500V . (6) T ACHOMETER Use the contactless type tacho meter . Fig. 8 -5 Fig. 8 -6 Fig. 8 -7[...]
-
Page 32
- 29 - 8-2 AC OUTPUT MEASURING Use a circuit like the shown in Fig.8-8 for measuring AC output. A hot plate or lamp with a power factor of 1.0 may be used as a load. Adjust the load and rpm. and check that the voltage range is as specified in T able 8-2 at the rated amperage and rated rpm. 8-3 DC OUTPUT MEASURING Measurement of DC output is execute[...]
-
Page 33
- 30 - 8-4 MEASURING INSULA TION RESIST ANCE Use a “Dr . Robin” generator tester in megger tester mode or use a megger tester to check the insula- tion resistance. Connect a megger tester to one of receptacle output terminals and the ground ter- minal, then measure the insulation resistance. An insulation resistance of 1 megohm or more is nor- [...]
-
Page 34
- 31 - * CONTROL P ANEL Measure the insulation resistances between the live parts and the grounded parts. Any part where the insulation resistance is less than 1M Ω has faulty insulation, and may cause electric leakage and electric shock. Replace the faulty part. Fig. 8 -1 3[...]
-
Page 35
- 32 - 9. CHECKING FUNCTIONAL MEMBERS 9-1 VOL TMETER Check the voltmeter if it is turned on by applying specific voltage. V oltmeter cannot be checked with circuit tester because its resistance is too large. 1 Check that no disconnection nor short-circuit occurs with a tester , and the internal resistance is around 00k ohms normally . 2 T urn on th[...]
-
Page 36
- 33 - 9-4 ST A T OR Disengage connectors on the wires from stator and check the resistance between wires with a “Dr . Robin” or a circuit tester referring to the fol- lowing table. NOTE : If the circuit tester is not sufficiently accurate, it may not show the values given and may give erroneous readings. Erroneous readings will also occur when[...]
-
Page 37
- 34 - 9-5 ROTOR ASSEMBL Y (1) Using a “Dr . Robin” or a circuit tester , measure the resistance of the field coil at the terminals. NOTE 1 : Because a diode is soldered to the coil ends at the terminals, resistance may be measured only when tester probes touche the terminals in one combination of polarity . Therefore, if no resistance reading [...]
-
Page 38
- 35 - * If such an instrument is unavailable, the condenser can be checked by replacing with a new one. If the generator performs good with new condenser , the cause of trouble is defect in original condenser . 9-7 DIODE RECTIFIER Circuit inside of the diode rectifiers is as shown in Fig. 9-7. Check continuity between each terminal by using a circ[...]
-
Page 39
- 36 - * Checking table for digital circuit tester . NOTE 1 : Because of the difference of measuring method between the analogue circuit tester and the digital circuit tester , polarity of tester needles should be reversed. NOTE 2 : ”Continuity” means forward direction characteristics of the diode, and different from short circuit condition (in[...]
-
Page 40
- 37 - 10. DISASSEMBL Y AND ASSEMBL Y 10-1 PREP ARA TION and PRECAUTIONS 1) Be sure to memorize the location of individual parts when disassembling the generator so that the generator can be reassembled correctly . T ag the disassembled part with the necessary information to facilitate easier and smoother reassembly . 2) For more convenience, divid[...]
-
Page 41
- 38 - p e t Se v o m e r o t t r a Pn o i t p i r c s e Ds k r a m e Rl o o T 1x o b l o r t n o Cf o m o t t o b e h t m o r f g n i h s u b e h t f f o e k a T ) 1 ( ) . 1 - 0 1 . g i F e e S ( . x o b l o r t n o c e h t g n i r i w e h t n o s r o t c e n n o c e h t t c e n n o c s i D ) 2 ( . r o t a n r e t l a e h t o t x o b l o r t n o c[...]
-
Page 42
- 39 - p e t Se v o m e r o t t r a Pn o i t p i r c s e Ds k r a m e Rl o o T 2k n a T l e u F. k a n t e h t m o r f l e u f e g r a h c s i D ) 1 ( . r e n i a r t s l e u f e h t t u h S . 1 . p u c r e n i a r t s e h t e v o m e R . 2 e h t r e d n u l e u f e v i e c e r o t l e s s e v a t u P . 3 o t k c o c l e u f e h t n e p o d n a r e[...]
-
Page 43
- 40 - p e t Se v o m e r o t t r a Pn o i t p i r c s e Ds k r a m e Rl o o T 3d n a r e l f f u M r e v o c r e l f f u M e h t x i f h c i h w s t l o b o w t e h t e v o m e R ) 1 ( o w t e h t n e s o o L . r o t a n r e t l a e h t o t r e l f f u m e v o m e r d n a e g n a l f r e l f f u m e h t n o s t u n . e n i g n e e h t m o r f r e [...]
-
Page 44
- 41 - p e t Se v o m e r o t t r a Pn o i t p i r c s e Ds k r a m e Rl o o T 4e m a r F e p i P0 0 1 6 V G R r o F ) 1 ( . e m a r f e h t m o r f r e n i a r t s l e u f e h t e v o m e R r e n n a p s m m 0 1 e n i g n e g n i x i f e r a h c i h w s t u n e h t e v o m e R ) 2 ( . s r e b b u r t n u o m e h t o t r o t a n r e t l a d n a ) .[...]
-
Page 45
- 42 - p e t Se v o m e r o t t r a Pn o i t p i r c s e Ds k r a m e Rl o o T 5r e v o c r a e R) . 1 1 - 0 1 . g i F e e S ( . r e v o c d n e e h t e v o m e R ) 1 ( ) 0 0 1 6 V G R t p e c x E ( 6 φ . s c p 3 . . . t l o b r o r e n n a p s m m 0 1 h c n e r w x o b e h t n e t s a f h c i h w s t l o b r u o f e h t e v o m e R ) 2 ( . g i F [...]
-
Page 46
- 43 - p e t Se v o m e r o t t r a Pn o i t p i r c s e Ds k r a m e Rl o o T 6r o t a t S. r e v o c r o t a t s e h t e v o m e R ) 1 ( Fig. 1 0 -1 4 Fig. 1 0 -1 5 SPRING WASHER : 4 pcs. REAR COVER COVER BOLT : 4 pcs. STATOR STATOR COVER BRUSHING GROMMET STATOR COVER STATOR[...]
-
Page 47
- 44 - p e t Se v o m e r o t t r a Pn o i t p i r c s e Ds k r a m e Rl o o T 7r o t o R. t l o b h g u o r h t e h t f f o e k a T ) 1 ( f o d a e h e h t n o h c n e r w x o b a y l p p A h t i w e l d n a h h c n e r w e h t t i H . t l o b h g u o r h t . n e s o o l o t e s i w k c o l c - r e t n u o c r e m m a h a h c n e r w x o B r e m m[...]
-
Page 48
- 45 - p e t Se v o m e r o t t r a Pn o i t p i r c s e Ds k r a m e Rl o o T 7r o t o Rr o t o r e h t f o d a e r h t e h t o t n i t l o b e h t w e r c S . 4 . t f a h s h c n e r w t e k c o s a g n i s u t l o b e h t e u q r o T . 5 . e s o o l f f o s e m o c r o t o r e h t l i t n u e h t e d i s n i e r u s s e r p c i l u a r d y h e h[...]
-
Page 49
- 46 - 10-3 ASSEMBL Y PROCEDURES 10-3-1 FRONT COVER Attach the front cover to the engine main bearing cover . Match the faucet joint and tighten the bolts. M8 x 20 mm bolt . . . 4 pcs. M8 spring washer . . . 4 pcs. 10-3-2 ROTOR (1) Wipe off oil, grease and dust from the tapered portion of engine shaft and matching tapered hole of rotor shaft. (2) M[...]
-
Page 50
- 47 - 10-3-3 ST A TOR (1) Put the stator in the rear cover setting the four grooves on the side of stator with thread holes of the rear cover . (2) Attach the stator cover around the stator . 10-3-4 REAR COVER (1) Put the rear cover with stator over the rotor . T ap on the rear cover evenly with a plastic hammer to press the rotor bearing into the[...]
-
Page 51
- 48 - 10-3-5 END COVER (RGV4100 only) Attach the end cover to the rear cover . 10-3-6 FRAME (1) Attach the mount rubbers to the frame. Insert the setting tongue of mount rubber into the hole on the frame and tighten the nut from the bot- tom of the frame. M8 flange nut . . . 4 pcs. NOTE : The mount rubbers are selected to reduce vibration most eff[...]
-
Page 52
- 49 - (4) Fasten the other earth cable with 5 mm termi- nal to the unpainted bolt hole on the frame. (See Fig.10-28.) 10-3-7 MUFFLER and MUFFLER COVER (1) T emporarily fix the muffler bracket to either the rear or front covers for RGV6100 or RGV2800. M8 x 20 mm bolt and washer Ass’y . . . 2 pcs. (2) Attach the muffler cover 1 and the muf fler co[...]
-
Page 53
- 50 - 3 For RGV2800 and 6100 : T ighten the two bolts to fix the muf fler bracket to the front cover , rear cover , and then the two bolts for the muffler to the muf fler bracket. M8 x 20 mm bolt and washer Ass’y . . . 4 pcs. (for RGV2800 and 6100) 10-3-8 FUEL T ANK (1) For RGV2600 and RGV4100 only : Attach the fuel strainer to the bottom of the[...]
-
Page 54
- 51 - 10-3-9 FRONT P ANEL Mount the front panel assembly to the frame. Refer to Section 10-4 for disassembly , checking and reassembly procedures of the front panel. (1) Connect the wires from the front panel and the engine. (2) Connect the wires drawn out from the stator to the wires from the front panel. NOTE : Connect the wires of the same colo[...]
-
Page 55
- 52 - 10-4-3 REASSEMBL Y (1) Install the receptacles, no-fuse breaker , terminals, switches, etc. on the control panel and wire them. NOTE : Circuit diagrams are shown in Section 12. Colored wires are used for easy identification, and are of the correct capacity and size. Use heat-resistant type wires (permissible temperature range 75 ° C or over[...]
-
Page 56
- 53 - 1 1. TROUBLESHOOTING 1 1-1 NO AC OUTPUT 1 1-1-1 CHECKING CONDENSER (1) Check the capacity of condensers using a “Dr . Robin” generator tester in capacitance meter mode. NOTE : Be sure to discharge condensers by shorting condenser leads each other before checking their capacitance, or the accurate reading cannot be obtained. (2) If such a[...]
-
Page 57
- 54 - (3) Check the insulation resistance between sta- tor core and each stator lead using a Dr . Robin generator tester in megger tester mode or a megger tester . (Fig. 1 1-3) If insulation is bad, replace stator with a new one. 1 1-1-3 CHECKING ROTOR (1) Remove rear cover and stator . (2) Using a Dr . Robin or a circuit tester , measure the resi[...]
-
Page 58
- 55 - (3) Measure the insulation across one of the sol- dered terminals of the rotor and the core. (Fig.1 1-6) If insulation is bad, replace rotor with a new one. 1 1-2 AC VOL T AGE IS T OO HIGH OR TOO LOW 1 1-2-1 CHECKING ENGINE SPEED If the engine speed is too high or too low , adjust it to the rated r .p.m. [How to adjust engine r .p.m.] * Loos[...]
-
Page 59
- 56 - 1 1-3 AC VOL T AGE IS NORMAL A T NO-LOAD, BUT THE LOAD CANNOT BE APPLIED. 1 1-3-1 CHECK THE ENGINE SPEED. If the engine speed is low , adjust it to the rated r .p.m. *Refer to Step 1 1-2-1 for engine speed adjustment. 1 1-3-2 CHECK THE TOT AL W A TT AGE OF APPLIANCES CONNECTED T O THE GENERA TOR. Refer to Section 7 “RANGE OF APPLICA TIONS?[...]
-
Page 60
- 57 - 1 1-4 NO DC OUTPUT 1 1-4-1 CHECK THE AC OUTPUT . Check the generator by following Step 1 1-1-1 through Step 1 1-1-3. 1 1-4-2 CHECK THE DC BREAKER. If the DC breaker turned off while charging a bat- tery , check the cables for short-circuit or connec- tion in reverse polarity before resetting it on. NOTE : If the DC output is used to charge a[...]
-
Page 61
- 58 - 1 1-4-6 CHECK THE DC COIL Check the resistance between two brown leads from stator with a circuit tester . If the resistance reading is much larger or smaller than the specified value, the DC coil of the stator is faulty . Replace stator with a new one. 1 1-5 IDLE CONTROL 1 1-5-1 ENGINE SPEED IS NOT INCREASED WHEN A LOAD IS APPLIED (1) Inspe[...]
-
Page 62
- 59 - (4) Check the wiring through ZCT on the IDLE CONTROL UNIT . * Single V oltage T ype Make sure that an output wire from main coil is passing through the ZCT on the IDLE CONTROL UNIT . * Dual V oltage T ype Check that two output wires (black wire and red wire) from main coils are passing through the ZCT on the IDLE CONTROL UNIT in the same dir[...]
-
Page 63
- 60 - 1 1-5-2 ENGINE SPEED IS NOT REDUCED WHEN LOAD IS OFF . (1) Check the distortion of the SOLENOID BRACKET as shown in step 1 1-5-1-(1). (2) Check the wiring of SOLENOID. Check two leads from SOLENOID are securely connected. (3) Check the wiring of IDLE CONTROL UNIT . Check all leads from IDLE CONTROL UNIT are securely and correctly connected. [...]
-
Page 64
- 61 - 12. WIRING DIAGRAM * RGV2800 : U.S.A., 60Hz-120V TYPE [NEMA RECEPT ACLE] * RGV4100 : U.S.A., 60Hz-120V/240V TYPE [NEMA RECEPT ACLE] V + - REC1 Field Winding Diode Sarge absorber Auxiliary Winding for condenser AC Winding 1 AC Winding 2 1.25Grn 1.25Brn 1.25Brn 1.25Y 1.25Y 2.0W 2.0R 2.0Blu 2.0Blk 2.0Blk Voltmeter No-fuse breaker AC output rece[...]
-
Page 65
- 62 - *RGV6100 : U.S.A., 50Hz-120V/240V TYPE [NEMA RECEPT ACLE V + - 120V 120V 120/240V 120/240V 8 1 9 5 3 6 7 4 2 8 9 1 5 3 6 7 4 REC1 GENERATOR CONTROL BOX Field Winding AC Winding 2 AC Winding 1 DC Winding Diode Sarge absorber 2 0.75W 0.75W 0.75Blu 0.75Blu 0.75Blk/W 0.75Grn/W 0.75Grn/W 0.75Blk 0.75Grn Auxiliary Winding for condenser 2.0Blu 2.0B[...]
-
Page 66
- 63 - + - CONTROL BOX 1.25Grn 1.25R 1.25Or 0.75Gry ST B -M +M IG Key switch 0.75Blk ( RGV4100 ) 1.25Blk ( RGV6100 ) Diode stack Assy ENGINE 0.75Blk 0.75Blk/W Oil sensor 0.75Grn/Y 0.75Grn/Y 0.75Blk/W Spark plug Battery Magnetiec switch 14Blk 14Blk 1.25Grn Electric starter 0.75Blu ( RGV4100 ) 0.75Grn/W ( RGV6100 ) Charge coil Ignition coil Earth (Gr[...]
-
Page 67
- 64 - 1. SPECIFICA TIONS Specifications are subject to change without notice. * : Electric starter motor model : RGV4101 and RGV6101. ENGINE AL TERNA TOR l e d o M1 0 1 4 V G R1 0 1 6 V G R e p y T e s a h P e l g n i S , e l o P - 2 , g n i t i c x E f l e S , s s e l h s u r B C A y c n e u q e r F z H 0 6 t u p t u O m u m i x a MW 0 0 1 4W 0 0[...]
-
Page 68
- 65 - 2. GENERA TOR TROUBLESHOOTING 2-1 NO AC OUTPUT 2-1-1 CHECKING CONDENSER (1) Check the capacity of condensers using a “Dr . Robin” generator tester in capacitance meter mode. NOTE : Be sure to discharge condensers by shorting condenser leads each other before checking their capacitance, or the accurate reading cannot be obtained. (2) If s[...]
-
Page 69
- 66 - (3) Check the insulation resistance between sta- tor core and each stator lead using a Dr . Robin generator tester in megger tester mode or a megger tester . (Fig. 2-3) If insulation is bad, replace stator with a new one. 2-1-3 CHECKING ROTOR (1) Remove rear cover and stator . (2) Using a Dr . Robin or a circuit tester , measure the resistan[...]
-
Page 70
- 67 - (3) Measure the insulation across one of the sol- dered terminals of the rotor and the core. (Fig.2-6) If insulation is bad, replace rotor with a new one. 2-2 AC VOL T AGE IS TOO HIGH OR T OO LOW 2-2-1 CHECKING ENGINE SPEED If the engine speed is too high or too low , adjust it to the rated r .p.m. [How to adjust engine r .p.m.] * Loosen the[...]
-
Page 71
- 68 - 2-3 AC VOL T AGE IS NORMAL A T NO-LOAD, BUT THE LOAD CANNOT BE APPLIED. 2-3-1 CHECK THE ENGINE SPEED. If the engine speed is low , adjust it to the rated r .p.m. *Refer to Step 2-2-1 for engine speed adjustment. 2-3-2 CHECK THE TOT AL W A TT AGE OF APPLIANCES CONNECTED T O THE GENERA TOR. Refer to Section 3 “ RANGE OF APPLICA TIONS ” for[...]
-
Page 72
- 69 - 2-4 NO DC OUTPUT 2-4-1 CHECK THE AC OUTPUT . Check the generator by following Step 2-1-1 through Step 2-1-3. 2-4-2 CHECK THE DC BREAKER. If the DC breaker turned off while charging a bat- tery , check the cables for short-circuit or connec- tion in reverse polarity before resetting it on. NOTE : If the DC output is used to charge a large cap[...]
-
Page 73
- 70 - Circuit inside of the diode rectifiers is as shown in Fig. 2-13. Check continuity between each terminal by using a circuit tester as shown in Fig. 2-14. The rectifier is normal when condtinuity is as follows: * Checking table for analogue circuit tester . Fig. 2-13 Fig. 2-14 r e t s e t t i u c r i c e u g o l a n A r e t s e t t i u c r i c[...]
-
Page 74
- 71 - 2-4-6 CHECK THE DC COIL Check the resistance between two brown leads from stator with a circuit tester . If the resistance reading is much larger or smaller than the specified value, the DC coil of the stator is faulty . Replace stator with a new one. 2-5 IDLE CONTROL (OPTIONAL EQUIPMENT) 2-5-1 ENGINE SPEED IS NOT INCREASED WHEN A LOAD IS AP[...]
-
Page 75
- 72 - (4) Check the wiring through ZCT on the IDLE CONTROL UNIT . * Single V oltage T ype Make sure that an output wire from main coil is passing through the ZCT on the IDLE CONTROL UNIT . * Dual V oltage T ype Check that two output wires (black wire and red wire) from main coils are passing through the ZCT on the IDLE CONTROL UNIT in the same dir[...]
-
Page 76
- 73 - 2-5-2 ENGINE SPEED IS NOT REDUCED WHEN LOAD IS OFF . (1) Check the distortion of the SOLENOID BRACKET as shown in step 2-5-1-(1). (2) Check the wiring of SOLENOID. Check two leads from SOLENOID are securely connected. (3) Check the wiring of IDLE CONTROL UNIT . Check all leads from IDLE CONTROL UNIT are securely and correctly connected. (4) [...]
-
Page 77
- 74 - 3. RANGE OF APPLICA TIONS Generally , the power rating of an electrical appliance indicates the amount of work that can be done by it. The electric power required for operating an electrical appliance is not always equal to the output watt- age of the appliance. The electrical appliances generally have a label showing their rated voltage, fr[...]
-
Page 78
- 75 - (5) Appliances without any indication as to power consumption Some appliances have no indication as to power consumption; but instead the work load (output) is indicated. In such a case, power consumption is to be worked out according to the numerical formula mentioned below . Efficiencies of some electrical appliances are as follows : Singl[...]
-
Page 79
- 76 - NOTES : Wiring between generator and electrical appliances 1. Allowable current of cable Use a cable with an allowable current that is higher than the rated input current of the load (electrical appliance). If the input current is higher than the allowable current of the cable used, the cable will become excessively heated and deteriorate th[...]
-
Page 80
- 77 - 4. WIRING DIAGRAM RGV4101 RGV4101 (Electric starter model) V + - 120V 120V 120/240V 120/240V REC1 W W REC3 GENERATOR CONTROL BOX Field Winding AC Winding 2 AC Winding 1 DC Winding Diode Sarge absorber Auxiliary Winding for condenser 2.0Blu 2.0Blk No-fuse breaker 2.0R Voltmeter 1.25Y 1.25Brn Condenser 2.0W 1.25Or 1.25Brn/W DC output terminal [...]
-
Page 81
- 78 - RGV6101 RGV6101 (Electric starter model) V + - 120V 120V 120/240V 8 1 9 5 3 6 7 4 2 8 9 1 5 3 6 7 4 REC1 REC3 W W REC2 GENERATOR CONTROL BOX Field Winding AC Winding 2 AC Winding 1 DC Winding Diode Sarge absorber 2 0.75W 0.75W 0.75W 0.75Blu 0.75Blu 0.75Blk/W 0.75Grn/W 0.75Grn/W 0.75Blk 0.75Grn 2.0Grn Auxiliary Winding for condenser 2.0Blu 2.[...]
-
Page 82
PRINTED IN THE USA 940 Lively Blvd. Wood Dale, IL 60191 Phone: 630-350-8200 Fax: 630-350-8212 e-mail: sales@robinamerica.com • www .robinamerica.com[...]