Subaru Robin Power Products RGXI 800 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 94 pages
- 4.37 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Portable Generator
Subaru Robin Power Products RGV12100
48 pages 0.93 mb -
Portable Generator
Subaru Robin Power Products R1200
102 pages 5.34 mb -
Portable Generator
Subaru Robin Power Products RGXI 800
94 pages 4.37 mb -
Portable Generator
Subaru Robin Power Products RGX505
35 pages 2.26 mb -
Portable Generator
Subaru Robin Power Products RGX2410
40 pages 2.21 mb -
Portable Generator
Subaru Robin Power Products EH65D
33 pages 0.74 mb -
Portable Generator
Subaru Robin Power Products RGD3310
39 pages 0.9 mb -
Portable Generator
Subaru Robin Power Products DY41
59 pages 3.03 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Subaru Robin Power Products RGXI 800. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Subaru Robin Power Products RGXI 800 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Subaru Robin Power Products RGXI 800 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Subaru Robin Power Products RGXI 800 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Subaru Robin Power Products RGXI 800
- nom du fabricant et année de fabrication Subaru Robin Power Products RGXI 800
- instructions d'utilisation, de réglage et d’entretien de l'équipement Subaru Robin Power Products RGXI 800
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Subaru Robin Power Products RGXI 800 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Subaru Robin Power Products RGXI 800 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Subaru Robin Power Products en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Subaru Robin Power Products RGXI 800, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Subaru Robin Power Products RGXI 800, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Subaru Robin Power Products RGXI 800. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
MANUAL Models RGXI 800,*. RGX2400, RGX3500, RGX5500 Generators PUB-GS0597B Rev. 8198[...]
-
Page 2
. . .[...]
-
Page 3
[...]
-
Page 4
i RGX1800 RGX2400 Model - - TY Pe Frequency Maximum Output Rated Output ~~~~ ~~ ~ ___~ ~ Brushless, Revolving Field, Self-Exciting,-2-Pole, Single Phase ~~~ ~ 50Hz I 60Hz I 50Hz I 60Hz 16ow I ~~ 1800W "I 2000w 7 2400W ~ 1300W I 1500W I 1700W I 2000w 11OV I 11.8A 1 11OV I 13.6A 11OV I 15.5A I 11OV I 18.2A Rated 220V I 5.9A I 120V 1 12.5A 220V I[...]
-
Page 5
I I Iu Model I RGX3500 I RGX5500 I I i - ~ ~ TY Pe ~ ~ ~ ~~~ Brushless, Revolving Field, Self-Exciting, 2-Pole, Single Phase Frequency 4800W 4400W 3000W 2500W Rated Output 5500W 5000W 3500W 3000W Maximum Output 60Hz 50HZ 60Hz 50Hz "". - . . I Voltage , . . . .. 110v 43.6A 110v 40A 110v 26.4A 110v 22.7A Rated 40A 120v 20A 220v 24.2A 120v 1[...]
-
Page 6
2. PERFOMANCE CURVES 2-1 MODEL RGX1800 I 3 6 9 12 15 CURRENT {A)& + -3-[...]
-
Page 7
u U t I > U - W a 5 0 > 1.5k - 3 -1k 5 n t- -0.5k 0 3 -0 bk c1.5k rz 0.5k 2 3 I- -0.5k o 2 -0 CURRENT (A) + -4-[...]
-
Page 8
> CURRENT (A)- 0 3 6 9 12 15 CURRENT (A)+ 2-2 MODEL RGX2400 + 5 0 > 2k 1.5k - t iz lk n 3 I- 0.5k o 3 0 2k 1.5k t lk I- n 3 I- 3 0.5k 0 CURRENT (A)- -5-[...]
-
Page 9
4 4 CURRENT (A)+ 0 4 a 12 16 20 CURRENT (A+ -2 k -t 1 -1k 3 I- 2 I- -3 0 -0 CURRENT (A)”--.) -6-[...]
-
Page 10
_." t 62 1 220 c 61 >. L: 60 z 3 59 w z K U 240 - > 200 a 00 5 2 4 6 a 10 12 w u > CURRENT (A)+ CURRENT iAl+ t IZt 1 -1k t- I- -3 0 2 -c -2k -t I is -1k E n I- 3 0 d -0 r 0 4 8 12 16 20 CURRENT (A) - -7-[...]
-
Page 11
4 8 12 16 20 CURRENT (A) - 2-3 MODEL RGX3500 t L 52 51 50 49 120 110 100 0 10 20 30 CURRENT (A!- 63 62 61 60 59 120 110 100 0 10 20 30 - 4k -3k t 3 -2k 2 k -1k 6 -0 CURRENT (A)- -a-[...]
-
Page 12
>- V z w 3 z a U /- z t CURRENT (A)+ -3k -2 t 3 - I- 3 0 3 -1k -0 U t - 4k - 3k -2k :- 1k 4 > 8 12 CURRENT [A)- t - > 0 I- d 0 > G a 14k CURRENT (A)- -9-[...]
-
Page 13
N I - % i, W z 3 U a W Y > W CY I- -I 3 > - a W 3 El LL CT 50 10 20 30 CURRENT [A!- LL W U i- -1 a C > 0 CURRENT [A)- -1 - 10-[...]
-
Page 14
2-4 MODEL RGX5500 - 4k -3k - t s -2k 3 a. t -1k 0 3 -0 t > 0 z 3 u 0 K U -3k 3 -2k 2 I- 3 -1k 0 I- -0 CURRENT (A)- CURRENT (AI+ - 11 -[...]
-
Page 15
62 61 60 59 130 120 110 0 10 20 30 40 50 - t 52 51 5 50 z - Ej 49 3, L= U 240 t 220 - 2 200 a w 13 t -1 20 5 10 15 20 25 ~ CURRENT (A)- N 61 I 60 - z cl a 5 53 IL U 240 f 220 I - > 200 (3 < t -1 0 0 5 10 15 > 20 25 LLI CURRENT [A)- LO LO - 6k :-t 4k - -3k 3 -2k 3 -1k 0 LO - 12-[...]
-
Page 16
U a CURRENT (A)- t > a - W a 0 -1 > CURRENT (AI - t a U - 5k I- z t- -2k 3 0 ~ lk -0 r 6k i - 13-[...]
-
Page 17
6k I:, c 5 -3k 3 a I- -2k o 3 r lk i CURRENT [A)- 2-5 DC OUTPUT The voltage curve shown in the left indicates the characteristic of DC output when charging a battery. The voltage may be decreased by 20% when the resistance load is applied. NOTE: It is possible to use both DC and AC out- puts simultaneously up to the rated output in total. - 14-[...]
-
Page 18
3. FEATURES 3-1 3-2 3-3 34 3-5 3-6 3-7 3-8 3-9 BRUSHLESS ALTERNATOR Newly developed brushless alternator eliminates troublesome brush maintenance. CONDENSER TYPE VOLTAGE REGULATOR A trouble free condenser type voltage regulator ensures a stable voltage under all working conditions. OIL SENSOR Oil sensor automatically shuts off the engine whenever t[...]
-
Page 19
4. GENERAL DESCRIPTION OF THE GENERATOR 4-1 EXTERNAL VIEW Of GENERATOR FULL POWER SWITCH (DUAL VOLTAGE TYPE) VOLTMETER (PILOT LAMP) e NO FUSE BREAKER (RGX1800.2400: CIRCUIT BREAKER) EARTH (GROUND) TERMINAL FUEL COCK PLUG COVER (SPARK PLUG, INSIDE) 7NK CAP GAUGE / DC OUTPUT TERMINAL OIL DRAINING PLUG (RGX3500 ONLY) -1 - 16-[...]
-
Page 20
4-2 CONTROL PANEL 0 RGXl800 : 50HZ-11 OV, 60Hz-120V TYPE VOLTMETER CIRCUIT BREAKER DC RGX2400 : 50HZ-11 OV, 60Hz-12OV TYPE VOLTMETER DC FUSE 0 P-T 0 CIRCUIT BREAKER AC RECEPTACLE DC OUTPUT TERMINAL EARTH (GROUND) TERMINAL - 17-[...]
-
Page 21
RGX1800, RGX2400 : 50Hz-220VY 240V, 60HZ-220V TVPE VOLTMETER DC FUSE DC OUTPUT TERMINAL RGX1800, RGX2400 : 5OHZ, 60H~-llOV/220V TYPE FULL POWER SWITCH 220V RECEPTACLE - AC RECEPTACLE EARTH (GROUND1 TERMINAL CIRCUIT BREAKER VOLTMETER 110V RECEPTACLE DC OUTPUT TERMINAL EARTH (GROUND) TERMINAL - 18 -[...]
-
Page 22
RGXl800,2400 : U.K., 50H~-llOV/12OV [BS RECEPTACLE] VOLTAGE CHANGEOVER SWITCH " CIRCUIT BREAKER VOLTMETER 220V RECEPTACLE "----- i A llOV RECEPTACLE DC FUSE DC OUTPUT TERMINAL EARTH (GROUND) TERMINAL RGX2400 : U.S.A., 60Hz-120V [NEMA RECEPTACLE] PILOT LAMP IDLE CONTRC (Option) RGX2400 : U.S.A., 60Hz-120V [NEMA RECEPTACLE] PILOT LAMP [...]
-
Page 23
RGXl800,2400 GERMANY, 50HZ-220V CIRCUIT BREAKER DC OUTPUT TERMINAL. t I AC 22OVl RGX1800,2400 : 50Hz-220V [WITH SPECIAL RECEPTACLE] DC FUSE 1 A 220V RECEPTACLE EARTH (GROUND) TERMINAL TJJJ 0 0 CIRCUIT BREAKER / VOLTMETER + 220V RECEPTACLE EARTH (GROUND) TERMINAL DC OUTPUT TERMINAL - 20 -[...]
-
Page 24
RGXI800,2400 : SWITZERLAND, 50Hz-220V DC FUSE DC OUTPUT TERMINAL OFF -n- c I AC 220V I 3 i vo CIRCUIT BREAKER ILTMETER L 22QV RECEPTACLE EARTH (GROUND) TERMINAL RGXl800,2400 : AUSTRALIA, 5OHZ-240V CIRCUIT BREAKER DC FUSE / ---. VOLTMETER - 24QV RECEPTACLE DC OUTPUT TERMINAL EARTH [GROUND) TERMINAL - 21 -[...]
-
Page 25
RGX3500 : 50HZ-11 OV, 60Hz-120V TYPE START SWITCH (Option) AC RECEPTACLE F VOLTMETER I EARTH (GROUND) TERMINAL RGX3500 : 50H~-220V, 240V, 60Hz-220V TYPE START SWITCH (Option) AC RECEPTACLE VOLTMETER C / C NO-FUSE BREAKER / DC F’ DC OUTPUT TERMINAL NO-FUSE BREAKER 0 SE DC FUSE / EARTH (GROUND) TERMINAL - 22 - DC OUTPUT TERMINAL[...]
-
Page 26
0 RGX3500 : 5OHZ, 60H~-llOV/220V TYPE NO-FUSE BREAKER START SWITCH (Option’ FULL POWER SWITCH / / Dc FUSE VOLTMETER - k 3 AC AC RECEPTACLE 7 0 EARTH (GROUND) TERM~NAL DC OUTPUT TERMINAL RGX3500 : U.K., 50H~-llOV/22OV [BS RECEPTACLE] START SWITCH VOLTAGE CHANGEOVER SWITCH NO-FUSE BREAKER (Option) / :DC FUSE VOLTMETER 220V RECEPl Lo ,/ J llOV[...]
-
Page 27
RGX3500 : U.S.A., 60H~-120V/24OV [NEMA RECEPTACLE] START SWITCH FULL POWER SWITCH NO-FUSE BREAKER (Option) IDLE CONTROL (Option) 240V RGX3500 : GERMANY, 50Hz-220V (Option’ START SWITCH VOLTMETER I 220v RECEPTACLE I 0 EARTH (GROUND) TERMINAL / 120V RECEPTACLE NO-FUSE BREAKER VOLTMETER /Dc FUSE EARTH(GROUND) TERMINAL - 24 - DC OUTPUT TERMINAL[...]
-
Page 28
RGX3500 : 50HZ-220V [WITH SPECIAL RECEPTACLE] 'Option' START SWITCH 220V RECEPTACLE VOLTMETER I 0 0 EARTH (GROUND) ~ERMINAL RGX3500 : SWITZERLAND, 50HZ-22OV (Option' START SWITCH 220v RECEPTACLE VOLTMETER I Jl 3 ,F 0 ~ ~~ EARTH (GROUND) TERMINAL - 25 - NO-FUSE BREAKER DC OUTPUT TERMINAL NO-FUSE BREAKER / DC OUTPUT TERMINAL[...]
-
Page 29
RGX3500 : AUSTRALIA, 50HZ-24OV START SWITCH VOLTMETER (Option) 240V RECEPTACLE * 0 0 0 EARTH (GROUND) TERMINAL RGX5500 : 50Hz-11 OV, 60Hz-120V TYPE VOLTMETER AC RECEPTACLF NO-FUSE BREAKER / DC FUSE / DC FUSE DC OUTPUT TERMINAL NO-FUSE BREAKER I I / START SWITCH EARTH (GROUND) TERMINAL - 26 - DC OUTPUT TERMINAL[...]
-
Page 30
RGX5500 : 50H~-22OV, 240V, 60Hz-220V TYPE VOLTMETER DC FUSE NO-FUSE BREAKER / START / AC RECEPTACLE EARTH (GROUND) TERMINAL DC OUTPUT TERMINAL RGX5500 : SOHZ, 60Hz-1 10V/220V TYPE 220V RECEPTACLE llQV RECEPTACLE EARTH (GROUND) TERMINAL - 27 - DC OUTPUT TERMINAL[...]
-
Page 31
0 RGX5500 : U.K., llOV RECEPTACLE 220v RECEPTACLE START SWITCH I RGX5500 : U.S.A., 60H~-120V/240V [NEMA RECEPTACLE] PILOT LAMP FULL POWER SWITCH 240V RECEPTACLE 120V RECEPTACLE / DC OUTPUT EARTH (GROUND) TERMINAL TERMINAL NO-FUSE BREAKER i 0 !GO31 1 EARTH (GROUND) TERMINAL IDLE CONTROL / (Option) START SWITCH - 28 -[...]
-
Page 32
RGX5500 : GERMANY, 50Hz-220V VOLTMETER DC FUSE AC 220V NO-FUSE BREAKER - START SWITCH 220v RECEPTACLE EARTH (GROUND) TERMINAL DC OUTPUT TERMINAL RGX5500 : 50Hz-220V WITH SPECIAL RECEPTACLE] VOLTMETER DC FUSE NO-FUSE BREAKER * Io kc 220v / START 220v RECEPTACLE EARTH (GROUN'D) TERMINAL DC OUTPUT TERMINAL - 29 -[...]
-
Page 33
0 RGX5500 : SWITZERLAND, 5OHZ-220V VOLTMETER DC FUSE NO-FUSE BREAKER / /START 220v RECEP~ACLE EARTH (GROUND) TERMINAL DC OUTPUT TERMINAL RGX5500 : AUSTRALIA, 50Hz-240V VOLTMETER DC FUSE NO-FUSE BREAKER / 24QV RECEPTACLE r AC 0 @ 0 0 / START SWITCH / EARTH (GROUND) TERMINAL DC OUTPUT TERMINAL - 30 -[...]
-
Page 34
4-3 LOCATION of SERIAL NUMBER and SPECIFICATION NUMBER Serial number and specification number are stamped on the LABEL (MODEL NAME) stuck on the end cover. NOTE: Always specify these numbers when inquiring about the generator or ordering spare parts in order to get correct parts and accurate service. LABEL, / MODEL NAME - 31 -[...]
-
Page 35
5. CONSTRUCTION AND FUNCTION 5-1 CONSTRUCTION END COVER REAR COVER ROTOR COMPLETE STATOR COMPLETE MOUNT RUBBER STATOR BOLT BALL BEARING THROUGH BOLT SUPPORT RING FRONT COVER 5-2 FUNCTION 5-2-1 STATOR The stator consists of a laminated silicon steel sheet core, a main coil and a condenser coil which are wound in the core slots. The condenser coil ex[...]
-
Page 36
5-2-2 CONDENSER One or two condensers are installed in the control box and are connected to the condenser coil of the stator. These condensers and condenser coil regulate the output voltage. 5-2-3 ROTOR The rotor consists of a laminated silicon steel sheet core and a field coil which is wound over the core. DC current in the field coil magnetizes t[...]
-
Page 37
5-24 FUSE. (1) The 10 ampere DC fuse mounted on the control panel protects whole DC circuit from getting damage by overload or short circuit. Fig. 5-6 5-26 NO-FUSE BREAKER The no-fuse breaker protects the generator from getting damage by overloading or short circuit in the appliance.Table 5-1 shows the capacity of no-fuse breaker by each spec. and [...]
-
Page 38
5-2-6 RECEPTACLE and AC PLUG (STD.SPEC.) These are used for taking AC output power from the generator. A total of five kinds of receptacles, each varying in rated voltage and current from another, are used. Each model has at least one receptacle to deliver the rated generator output. As many AC plugs as the receptacles, each matching the correspond[...]
-
Page 39
5-3 DESCRIPTION of GENERATOR OPERATION PERMANENT MAGNET FOR INITIAL EXCITATION STATOR MAIN COIL Fig. 5-8 5-3-1 GENERATION Of NO-LOAD VOLTAGE When the generator starts running, the permanent magnet built-in to the rotor generates 3 to 6V of AC voltage in the main coil and condenser coil wound on the stator. As one or two condensers are connected to [...]
-
Page 40
" 5-34 FULL POWER SWITCH (Dual Voltage Type) The full power switch is provided for the dual voltage type to take out the full rated power from one receptacle in each voltage. 120124ov r - - - i (or 110122Ov) 240V (or 220V) f - - 120124ov r - - - i (or 110122Ov) 1 240V (or 220V) Fig. 5-9 i MC, Fig. 5-10 Ret. 1 Switch LOWER VOLTAGE Position RECE[...]
-
Page 41
Two main coils are wound over stator core. Each main coil outputs half the rated power at the lower voltage (llOV or 120V). These main coils are wound to be in the same phase. The full power switch reconnects these main coils in parallel or in series. Fig. 5-9 shows a circuit diagram-When the full power switch is set for single lower voltage indica[...]
-
Page 42
6. SAFETY PRECAUTIONS ● 1. 2. 3. 4. 5. e 6. 7. Use extreme caution near fuel. A constant danger of explosion or fire exists. Do not fill the fuel tank while the engine is running. Do not smoke or use opem flame near the fuel tank. Be careful not to spill fuel when refueling. If spilt, wipe it and let dry before starting the engine. Do not place i[...]
-
Page 43
7. RANGE OF APPLICATIONS Generally, the power rating of an electrical appliance indicates the amount of work that can be done by it.The electric power required for operating an electrical appliance is not always equal to the output wattage of the appliance. The electrical appliances generally have a label showing their rated voltage, frequency, and[...]
-
Page 44
:. : ( _ ~. I .-.. .- (5) Appliances without any indication & t& -&&ver consumption Some appliances have no indication as to power consumption; but instead the work load (output) is indicated. In such a case, power consumption is to be worked out according to the numerical formula mentioned below. (Output of electrical appliance) = [...]
-
Page 45
NOTES: Wiring between generator and electrical appliances 7. Allowable current of cable Use a cable with an allowable current that is higher than the rated input current of the load (electrical appliance). If the input current is higher than the allowable current of the cable used, the cable will become excessively heated and deteriorate the insula[...]
-
Page 46
. 8. MEASURING PROCEDURES 8-l MEASURING INSTRUMENTS 8-1-l “Dr. ROBIN” GENERATOR TESTER The “Dr. RobirPgenerator tester is exclusively designed for fast, easy diagnosis and repair of Robin generators. The “Dr. Robin” has the following features: (1) Functions of voltmeter, frequency meter, meggertester, capacitance meter and circuit tester [...]
-
Page 47
8-l-2 INSTRUMENTS (1) VOLTMETER AC voltmeter is necessary-The approximate AC voltage ranges of the voltmeters to be used for various types of generators are as follows: 0 to 15OV: Type with an output voltage of 110 or 120V 0 to 300V: Type with an output voltage of 220,230 or 240V 0 to 15OV, 0 to 330V: Dual voltage type (2) AMMETERS AC ammeter is ne[...]
-
Page 48
(4) CIRCUIT TESTER Used for measuring resistance, etc. (5) MEGGER TESTER Used for measuring generator insulation resistance. Select one with testing voltage range of 5oov. I I Fig. 8-5 I I Fig. 8-6 There are various types of tachometers, such as contactless type, contact type, and strobe type. The contact type can be used only when the generator an[...]
-
Page 49
8-2 AC OUTPUT MEASURING TO AC RECEPTACLE Fig. 8-8 Use a circuit like the shown in Fig.88 for measuring AC output. A hot plate or lamp with a power factor of 1.0 may be used as a load. Adjust the load and rpm. and check that the voltage range is as specified in Table 8-2.at the rated amperage and rated rpm. - Rated voltage 1lOV 120v 22OV 240v Voltag[...]
-
Page 50
l ROTOR Measure the insulation across one of the soldered l terminals of the rotor and the core. l CONTROL PANEL Measure the insulation resistances between the live parts and the grounded parts. Fig. 8-l 1 Fig. 8-12 Any part where the insulation resistance is less than 1MQ has faulty insulation, and may cause electric leakage and electric shock. Re[...]
-
Page 51
9. CHECKING FUNCTIONAL MEMBERS 9-l PILOT LAMP and VOLTMETER Check the pilot lamp and the voltmeter if it is turned on by applying specific voltage. Pilot lamp and voltmeter cannot be checked with circuit tester because its resistance is too large. (See Fig.9-1.) n. Fig. 9-1 Pilot lamp should be turned on at 70 to 120V. 9-2 AC RECEPTACLES Using a ?[...]
-
Page 52
9-3 CIRCUIT BREAKER Check continuity between each of two terminals at the rear of the circuit breaker while it is mounted on the control panel. Normally, there is continuity between each of the two when the circuit breaker is on while there is no continuity when the circuit breaker is off. 9-4 STATOR Disengage connectors on the wires from stator an[...]
-
Page 53
9-5 ROTOR ASSEMBLY (1) Using a “Dr. Robin” or a circuit tester, measure the resistance of the field coil at the terminals. (RXlQ &lo%) MODEL RGX1800 RGX2400 RgEy Rgzy RGXSOO RESISTANCE 2.5 Q 2.7 $2 2.1 R 2.2 R 1.6 R Table 9-2 NOTE 1: Because a diode is soldered to the coil ends at the terminals, resistance may be measured only when tester p[...]
-
Page 54
n NORMAL CAPACITY OF CONDENSER MODEL RGXl BOO RGX2400 RGX3500 RGX5500 0 14,xF 20,~F 17fiFX2 28,~FX2 Resistance 0 14,~F 20,~F 17pFX2 28fiFX2 Table 9-3 H If such an instrument is unavailable, the condenser can be checked by replacing with a new one. If the generator performs good with new condenser, the cause of trouble is defect in original condense[...]
-
Page 55
n Checking table for digital circuit tester. Apply red @ needle of the circuit tester Digital circuit tester Brown Brown Orange Brown/White Brown No continuity 1 No continuity Continuity Apply black 0 needle of the circuit tester Brown drange No continuity Continuity Continuity Continuity I I .I Brown/White No continuity No continuity No continuity[...]
-
Page 56
104 DISASSEMBLY PROCEDURES Step Part to remove Description Remarks Tool 1. Fuel Tank (1) Discharge fuel from the tank. Use utmost care about 1. Shut the fuel strainer. fire hazard. 2. Remove the strainer cup. 3. Put a vessel to receive fuel under the strainer and open the fuel cock to discharge fuel. (See Fig. 10-l.) Wipe off sprit fuel thoroughly.[...]
-
Page 57
tep Part to remove Description Remarks Tool 2. Control Box (1) Take off the grommet from the rear pannel of control box. (See Fig. 10-4.) (2) Disconnect the connector on the wiring from the control box to the alternator. (3) Remove the fuel strainer. Remove the nut on top of the fuel strainer located beside the control box. (See Fig. 10-S.) Fig. IO[...]
-
Page 58
. . : Step Part to remove Description Remarks Tool 3. Pipe Frame (1) Remove SIDE PLATE from frame. 10 mm spanner 0: (See Fig. 10-8.) box wrench 64 bolt. . . . _ . . . . . . . . . . . 2 pcs. Remove the mount rubbers from SIDE PLATE. (2) Remove the nuts which fix the engine and alternator on the mount rubbers. (3) Dismount the engine and alternator f[...]
-
Page 59
itep Part to remove Description Remarks Tool 4. Rear Cover (1) Remove the end cover. (See Fig. 10-l 1.) 10 mm spanner 01 66 bolt . . . . . _ . . . . . _ _ . . _ 4 pcs. box wrench (2) Take off the rear cover. 1. Remove the four bolts which fasten 10 mm spanner 01 the rear cover to the front cover. box wrench 6@f,c,lt . . . . . . . . . . . .._.. dpcs[...]
-
Page 60
Step Part to remove Description : Remarks Tool 5. Staitor (1) Remove the four bolts which fasten the 10 mm socket stator to the rear cover. wrench (See Fig. 10-14.) &BOLT . . . . . .4pcs. 60 SPRING WASHER Fig. 10-14 (2) Rut a piece of lumber on the floor in upright position. (See Fig. 10-E) (3) Hold the rearcover and stator upside down with bot[...]
-
Page 61
Zep Part to remove Description Remarks Tool 5. Stator (5). Take apart the support ring and stator from rear cover. SUPPORT RING @BOLT . . . _ _ .4pcs. w SPRING WASHER . . . . . . . . . . 4 PCS. @WASHER . . . . 4~~s. Fig. 10-17 6. Rotor (1) Take off the through bolt. Box wrench Apply a box wrench on the head of Plastic hammer through bolt. Hit the w[...]
-
Page 62
tep Part to remove Description Remarks Tool 6. Rotor (3) Use a bolt and oil as a tool for pulling out rotor in the following procedures : 1. Pour engine oil into the center hole of rotor shaft. Fill with oil to the shaft end. (See Fig. 10-19.) 2. Prepare a bolt with the following thread size: RGX1800,2400,3500. . MlOXP1.25 RGX5500........... M12XP1[...]
-
Page 63
Step Part to remove Description Remarks Tool 7. Front Cover (1) Remove the front cover. 12 mm Socket Loosen the four bolts and remove the wrench front cover. 84 bolt.. . . . . . . . . . . . . . .4pa. Fig. 10-22 - 60 -[...]
-
Page 64
104 ASSEMBLY PROCEDURES 104-l FRONT COVER Attach the front cover to the engine main bearing cover. Match the faucet joint and tighten the bolts. M8 X 18mm bolt . . . . . .4 pcs. M8 spring washer . . _ . -4 pcs. Tightening torque : 120 - 140 kg-cm 8.7 - 10.1 ftlbs. 104-2 ROTOR (1) Wipe off oil, grease and dust from the tapered portion of engine shaf[...]
-
Page 65
(3) Apply the support ring between the rear cover and the stator. Tap on the support ring evenly using an aluminum bar and a hammer to press into the rear cover. (See Fig-lo-26.) CAUTION: Be careful of the position of hook- ing holes of the support ring. (4) Join the stator to rear cover with four bolts, washers and spring washers. (See Fig. 10-25.[...]
-
Page 66
1044 REAR COVER (1) Attach the bushing over the lead wire drawn out from the rear cover. Press the smaller end of the bushing into the window of the rear cover. (See Fig.lO-27.) Fig. 10-27 (2) Put the rear cover with stator over the rotor. Tap on the rear cover evenly with a plastic hammer to press the rotor bearing into the rear cover. (3) Fix the[...]
-
Page 67
104-S END COVER Attach the end cover to the rear cover. M6 X 8mm flange bolt *.--.-.-*-. 4 PCS. Tightening torque : 40 - 60 kg-cm 2.9 - 4.3 ftlbs. Fig. lo-30 104-6 FRAME (1) Attach the mount rubbers to the frame. Insert the setting tongue of mount rubber into the hole on the frame and tighten the nut from the bottom of the frame. M8 flange nut . . [...]
-
Page 68
(3) Install the engine and alternator assembly into. the frame. Put the engine and alternator assembly into the frame from the side of it. Tighten the nuts over the mount rubber bolts to fix. M8 nuts Tightening torque : 120 - 140 kg-cm 8.7 - 10.1 ftlbs. Fig. IO-32 NOTE : When tightening the nuts, slightly lift the engine and‘altemator assembly so[...]
-
Page 69
(3) Press the upper end of the bushing into the bottom window of the control box. Attach the grommet for the oil sensor wires to the rear panel of the control box. (4) Mount the control box to the frame. M6 X12 mm fiange bolt ..-*..***. 3 pcs. Tightening torque : 40 - 60 kg-cm 2.9 - 4.3 ftlbs. PUSH Fig. lo-34 Fig. 10-35 (5) Fasten the one earth cab[...]
-
Page 70
10-4-8 FUEL TANK 1) Connect the rubber pipe to the engine carburetor and fasten it with a hose clamp. Attach the banjo to the opposite end of the rubber pipe, tighten it with a hose clamp, and fasten the pipe to the fuel strainer with the banjo bolt. 2) Fasten the strainer to the strainer bracket with the joint nuts. 3) Mount the fuel tank on the s[...]
-
Page 71
10-S CHECKING, DISASSEMBLY and REASSEMBLY of the CONTROL BOX 10-5-l CHECKING OF THE CONTROL BOX Dismount the control box from frame. Remove the control panel and check each components and wiring. Refer to Section 9 for the detail of checking procedure for the components in the control box. 10-5-2 DISASSEMBLY (1) Remove the control panel from the co[...]
-
Page 72
11. TROUBLESHOOTING 0 11-l NO AC OUTPUT 11-1-l CHECKING CONDENSER Check the capacity of condensers using a “Dr. Robin”generator tester in capacitance meter mode. NOTE : Be sure to discharge condensers by shorting condenser leads each other before checking their capacitance, or the accurate reading cannot be obtained. Fig. 11-l n NORMAL CAPACITY[...]
-
Page 73
n Check the insulation resistance between stator core and each stator lead using a Dr. Robin generator tester in megger tester mode or a megger tester. (Fig. 11-3) If insulation is bad, replace stator with a new one. 1 l-1 -3 CHECKING ROTOR (1) CHECKING FIELD COIL n Remove rear cover and stator. Fig. 11-4 n Using a Dr. Robin or a circuit tester, me[...]
-
Page 74
W IMeasure the insulation across one of the soldered terminals of the rotor and the core. = (FigAl-6) If insulation is bad, replace rotor with a new one. Fig. 11-6 11-2 AC VOLTAGE IS TOO HIGH OR TOO LOW 11-2-l CHECKING ENGINE SPEED If the engine speed is too high or too low, adjust it to the rated r.p.m. [How to adjust engine r.p.m.1 W Loosen the l[...]
-
Page 75
1 l-3 AC VOLTAGE IS NORMAL AT NO-LOAD, BUT THE LOAD CANNOT BE APPLIED. 11-3-l CHECK THE ENGINE SPEED. If the engine speed is low, adjust it to the rated r.p.m. * Refer to Step 11-2-1 for engine speed adjustment. 11-3-2 CHECK THE TOTAL WAlTAGE OF APPLIANCES CONNECTED TO THE GENERATOR. Refer to Section 7 “RANGE OF APPLICATIONS” for the wattage of[...]
-
Page 76
11-4 NO DC OUTPUT 0 11-4-l CHECK THE AC OUTPUT. Check the generator by following Step 11-1-l through Step 11-1-3. 1 l-4-2 CHECK THE DC FUSE. Check the fuse in the fuse holder. If the fuse is blown, check for the cause of fuse blowing, and then replace with a new one. FUSE : 10A FUS NOTE: If the DC output is used to charge a large capacity battery o[...]
-
Page 77
11-5 IDLE CONTROL (OPTIONAL EQUIPMENT) 11-5-l ENGINE SPEED IS NOT INCREASED WHEN A LOAD IS APPLIED (1) Inspect the solenoid bracket. Check the bend angle of solenoid bracket. If the bracket is distorted, correct the angle with proper tool. .EN SOLENOID BRA&ET RGX2400,3!500 SOLENOID p-g&+$ SOLENOID f&KET f I RGX5500 Fig. 17-12 (2) Check [...]
-
Page 78
(4) Check the wiring through ZCT on the IDLE CONTROL UNIT BOARD. A) Single Voltage Type Make sure that an output wire from main coil is passing through the ZCT on the IDLE CONTROL UNIT. B) Dual Voltage Type Check that two output wires (black wire and red wire) from main coils are passing through the ZCT on the IDLE CONTROL UNIT in the same directio[...]
-
Page 79
11-5-2 ENGINE SPEED IS NOT REDUCED WHEN LOAD IS OFF. (1) Check the distortion of the SOLENOID BRACKET as shown in step 11-5-l-(1). - (2) Check the FUSE on wiring of IDLE CONTROL UNIT. l Remove the control panel from control box. l Check the FUSE in the fuse holder of IDLE CONTROL UNIT. If fuse is blown, replace with a new one. (FUSE : 0.3A) FUSE FU[...]
-
Page 80
12. WIRING DIAGRAM Ii C. B. 0 l RGX1800 : 50Hz-1 lOV, 6OHz-120V TYPE GENERATOR CONTROL BOX --1 r------- -- l! I GREEN -- YELLOW E II .-. l RGX2400 : 50Hz-11 OV, 60Hz-120V TYPE GENERATOR CONTROL BOX r------1 --- -- 1 --------- 0.75 ,,2 2.0 mm2 --- 1.25 mm2 3.5 mm2 - 77 - c[...]
-
Page 81
0 RGX180~,2400:50Hz-220V,240V,60Hz-220V TYPE GENERATOR CONTROL BOX r--1 7-i. 8. [NFBI -- ORANGE f’, +,T BROWN - - RROWN I _ _ . _ - JTE l RGXI 800,240O : 50Hz, 6OHz-11 OV/22OV TYPE GENERATOR CONTROL BOX C. B. - SW 02=----l! - ---_--___ O-75 mm2 ---_--___ O-75 mm2 2.0 mm2 2.0 mm2 --- --- 1.25 mm2 1.25 mm2 3.5 mm2 3.5 mm2 - 78 - - 78 - i[...]
-
Page 82
l RGXI 800,240O : U.K., 50Hz-1 lOV/22OV [BS RECEPTACLE] GENERATOR CONTROL BOX I I BLACK C. B. - r-- i c- l RGX2400 : U.S.A., 60Hz-120V [NEMA RECEPTACLE with IDLE CONTROL] CONTROL BOX p F i ---- -___ - 0.75mm2 2.0 mm2 --- 1.25 mm2 3.5 mm2 - 79 -[...]
-
Page 83
l RGX3500 : SOHz-11 OV, 5OHz-120V TYPE GENERATOR CONTROL BOX --- 1 -- -- l RGX3500 : SOHz-220V, 24OV, 6OHz-220V TYPE SENERATOR CONTROL BOX ---I y-&B, -- m REC em FC 3 -- -i I I I II I I! 1 I 1 i E I, DC ! ii GREEN/YELL0 W -- II -- E YELLOW _ +*c YELLOW 1 3 +T 4 DC OUT d -_----___ 0.75 ,,,& 2.0 mm2 --- 1.25 mm2 3.5 mm2 - 80 - i[...]
-
Page 84
l RGX3500 : SOHz, 6OHz-1 lOW22OV TYPE GENERATOR CONTROL BOX --1 I me -- II 1 SC ; r- GREEN/YELLOW -- I! YELLOW _ I I L-3 1 I 8 I 1 YELLOW TC Bc l RGX3500 : U.K.., SOHz-1 lOW22OV [BS RECEPTACLE] GENERATOR CONTROL BOX 1 m FC _--- _____ 0.75mm2 2.0 mm2 --- 1.25 mm2 3.5 mm2 - 81 -[...]
-
Page 85
8 RGX3500 : U.S.A., 60Hz-120W240V [NEMA RECEPTACLE with IDLE CONTROL] ENGINE CONTROL BOX r--1 I-- _- I I ICSW - --. -- BLUE 1-1 -- l RGX5500 : SOHz-11 OV, 60Hz-120V TYPE GENERATOR CONTROLBOX --1 I-------- -- 1 1 1 GREEN/YELLOW YELLOW I BROWN - E --_----__ 0.75 mm2 2.0 mm2 --- 1.25 mm2 3.5 mm2 - 82 - i[...]
-
Page 86
l RGX5500 : SOHz-220V, 24OV, 60Hz-220V TYPE GENERATOR CONTROL BOX ---I I-- -- NFB - RECl REC2 GREENIYELLC _ UT l RGX5500 : SOHz, 60Hz-11 OW22OV TYPE GENERATOR CONTROL BOX -- -- -- I RI ArU I- Y--Y.. r I I- II I I! II c3 i i 1----. ,.,-. . ^._. Ii II P‘ 1; LLEb btlttN/YtLLUW 1 ll - -_ -_ u “1 I : G:c -_ Ii BROWN i BROWN E .o 2.0 mm2 ----_---- O-[...]
-
Page 87
l RGX5500 : U.K., SOHz-1 lOV/22OV [BS RECEPTACLE] GENERATOR CONTROL BOX II II II RECa 00 0 P I : l RGX5500 : U.S.A., 60Hz-120V/240V [NEMA RECEPTACLE with IDLE CONTROL] ENGINE CONTROL BOX r-1 I __ - LIGHT BLUE I -L I I F SOL. I I LIGHT BLUE n FENERATOR 1 ( REC, - ?-P f RI FC .MC I ----__--- O-75 mm2 2.0 mm2 --- 1.25 mm2 3.5 mm2 - 84 -[...]
-
Page 88
l TYPE WITH OIL SENSOR (Optional Equipment) I I eP-l I I I I I i I L 1 L ---a I I i L i - -----A------ I I -- t 1 -a---------- GENERATOR I I I BLACK r-------------------- ---- I L2 I I YELLOW i EN&NE .-m CONTROL BOB ----- ---- 0.75 mm2 --- 1.25 mm2 2.0 mm2 3.5 mm2 - 85 -[...]
-
Page 89
l RGX3500 : ELECTRIC STARTER TYPE (Optional Equipment) -- The battery cords have a cross sectional area of 22 mm’. -------__ 0.75 mm2 --- 1.25 mm2 2.0 mm2 3.5 mm2 - 86 -[...]
-
Page 90
l RGX5500 : ELECTRIC STARTER TYPE (Optional Equipment) 1 --- SP I ENGINE = = GREEN/WHITE -m-s------ GREEN/WHITE b I .-_-------- I I I The battery cords have a cross sectional area of 22 mm’. __------- 0.75 mm2 --- 1.25 mm2 2.0 mm2 3.5 mm2 - 87 -[...]
-
Page 91
l RGX3500 : ELECTRIC STARTER TYPE WITH OIL SENSOR (Optional Equipment) ; e pn 1’ i I -‘) I 7h I ! I I I I I I I I I I I REEN/WHITE j I I --m--------w- I L . losr i I , BLACK I -- i YELLOW/RED I r *J YELLOW I ORANGE ----mm-- II II E RED -.-i ; -- The battery cords have a cross sectional area of 22 mm’. ----m---w 0.75 mm2 -- 1.25 mm2 2.0 mm2 3[...]
-
Page 92
l RGX5500 : ELECTRIC STARTER TYPE WITH OIL SENSOR (Optional Equipment) SP --- I i I ; PINK 1; I ;YELLOV YELLOW/RED YELLOW -- + I I I I I I.L I ..a.. J i GREEN ------ El I L -- --- CONTROL BOX The battery cords have a cross sectional area of 22 mm’. --------- 0.75 mm2 --- 1.25 mm2 2.0 mm2 3.5 mm2 - 89 -[...]
-
Page 93
I Symbols 1 Part Name I 1 C 1 Condenser I 1 D 1 Diodes Stack Assy I L, Lz T F C.B. Pilot Lamp Warning Lamp (Oil sensor) DC Output Terminal Fuse Circuit Breaker I NFB, ( No-Fuse Breaker I I NFBp 1 No-Fuse Breaker I I vc SW 1 Voltage Changeover Switch I FP SW Full Power Switch ssw Engine Stop Switch OS Oil Sensor osc Oil Sensor Controller SIU I Solid[...]
-
Page 94
I America, Inc. 940 Lively Blvd. l Wood Dole, 1160191 l Phone: 630-350-8200 l Fax: 630-350-8212 e-mail: sales @robinamerica.com l www. robinamefkxcom PRINTED IN THE USA[...]