Sunrise Medical Quickie V-121 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 23 pages
- 0.62 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Mobility Aid
Sunrise Medical P300
50 pages 1.86 mb -
Mobility Aid
Sunrise Medical 53314-8
24 pages 1.14 mb -
Mobility Aid
Sunrise Medical Zippie 2
7 pages 0.48 mb -
Mobility Aid
Sunrise Medical C001022
1 pages 0.1 mb -
Mobility Aid
Sunrise Medical P-222
29 pages 2.12 mb -
Mobility Aid
Sunrise Medical C001023
1 pages 0.19 mb -
Mobility Aid
Sunrise Medical Quickie Built-4-Me C001040
1 pages 0.09 mb -
Mobility Aid
Sunrise Medical C001023B
1 pages 0.19 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Sunrise Medical Quickie V-121. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Sunrise Medical Quickie V-121 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Sunrise Medical Quickie V-121 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Sunrise Medical Quickie V-121 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Sunrise Medical Quickie V-121
- nom du fabricant et année de fabrication Sunrise Medical Quickie V-121
- instructions d'utilisation, de réglage et d’entretien de l'équipement Sunrise Medical Quickie V-121
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Sunrise Medical Quickie V-121 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Sunrise Medical Quickie V-121 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Sunrise Medical en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Sunrise Medical Quickie V-121, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Sunrise Medical Quickie V-121, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Sunrise Medical Quickie V-121. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
SUPPLIER: THIS MANUAL MUST BE GIVEN T O THE RIDER OF THIS WHEELCHAIR. RIDER: BEFORE USING THIS WHEELCHAIR READ THIS ENTIRE MANUAL AND SA VE FOR FUTURE REFERENCE. User Instruction Manual & W arranty Quickie V- 1 21[...]
-
Page 2
2 3 930483 Rev . A 930483 Rev . A 11. T ABLE OF CONTENTS 1. INTRODUCTION .............................................................................. 2 11. T ABLE OF CONTENTS .................................................................. 3 111. Y OUR CHAIR AND ITS P AR TS .................................................. 5 IV . NO TICE - REA[...]
-
Page 3
4 5 930483 Rev . A 930483 Rev . A 111. Y OUR CHAIR AND ITS P ARTS QUICKIE V -121 1 2 3 7 4 5 6 10 15 11 13 12 14 8 9 1. Push Handle 2. Jo ystick 3. Integral Controller 4. Swing-Awa y Footrest 5. Heel Loop 6. Foot Plate 7. Cross Brace 8. Caster Fork 9. Caster Tire 10. Backrest 11. Drive Wheel 12. Motor 13. Batter y 14. Swing-Awa y Rrelease Latch 15.[...]
-
Page 4
1V . NO TICE—READ BEFORE USE A. CHOOSE THE RIGHT CHAIR & SAFETY OPTIONS Sunrise pro vides a choice of many power wheelchair styles, sizes and adjust- ments to meet the needs of the rider . Howe ver , final selection of a wheelchair rests solel y with you and y our health care prof essional. Choosing the best chair for y ou depends on such thi[...]
-
Page 5
8 9 930483 Rev . A 930483 Rev . A 2. Medium-Range Mobile T ransceiv ers: These include two-wa y radios used in police cars, fire trucks, ambulances and taxi cabs. The antenna is usually mounted on the outside of the vehicle. 3. Long-Range T ransceivers: These include commercial radio and TV br oadcast antenna towers and amateur (HAM) radios. Note: [...]
-
Page 6
10 11 930483 Rev . A 930483 Rev . A V1. GENERAL W ARNINGS C. WEIGHT LIMIT 1. Nev er exceed a total weight of 250 pounds (113.6 kilograms) for rider plus items carried. 2. Nev er use this chair for weight training if the total weight (rider plus ad ditional weights) exceeds 250 pounds. 3. Exceeding the weight limit is lik ely to damage the seat, fra[...]
-
Page 7
12 13 930483 Rev . A 930483 Rev . A VI. GENERAL W ARNINGS K. STREET USE In most states, power chairs ar e not legal for use on public roads. Be alert to the danger of motor vehicles on r oads or in parking lots. 1. At night, or when it is hard to see, use reflectiv e tape on your chair and clothing. 2. It ma y be hard for drivers to see y ou. Make [...]
-
Page 8
14 15 930483 Rev . A 930483 Rev . A VI. GENERAL W ARNINGS O . REA CHING OR LEANING Reaching or leaning affects the center of balance of y our chair . If done impr operly , a fall or tip-ov er is lik ely . When in doubt, ask for help or use a device to extend your r each. T O REDUCE THE RISK AND/OR D AMA GE T O THE CHAIR: 1. Never r each or lean if [...]
-
Page 9
16 17 930483 Rev . A 930483 Rev . A VI. GENERAL W ARNINGS Fig. 1 T . T O REDUCE THE RISK OF A F ALL, TIP-O VER OR LOSS OF CONTROL: 1. Never use y our chair on a slope unless you ar e sure you can do so without losing traction. 2. Alwa ys go as straight up and as straight down as y ou can. • Do not “cut the corner” on a slope or ramp . • Do [...]
-
Page 10
18 19 930483 Rev . A 930483 Rev . A W . CURBS & SINGLE STEPS 1. Y our chair is not designed to drive up or do wn a curb or step more than two (2) inches high. Doing so ma y: • Result in a fall or tip-ov er . • Damage the frame , wheels, axles or other chair parts, or loosen fasteners. 2. T o pr event a fall or tip-ov er , use wheelchair acc[...]
-
Page 11
20 21 930483 Rev . A 930483 Rev . A F . FOOTRESTS 1. At the lowest point, footr ests should be at least 21/2 inches off the ground. If set too LO W , they ma y “hang up” on obstacles y ou can expect to find in normal use. This may cause the chair to stop sud denly and tip forward. 2. T o a void a trip or fall when you transf er : • Mak e sure[...]
-
Page 12
22 23 930483 Rev . A 930483 Rev . A VII. W ARNINGS: COMPONENTS & OPTIONS M. SEA TING SYSTEMS 1. Use of a seating system not appro ved b y Sunrise may alter the center of balance of this chair . This may cause a fall or tip-ov er . 2. Ne ver change the seating system of y our chair unless you consult your supplier first. N. UPHOLSTER Y F ABRIC 1[...]
-
Page 13
24 25 930483 Rev . A 930483 Rev . A A. NOTES 1. W ork Surface F or Set-Up: Use a flat surface, such as a table, to assemble , adjust and check your chair . This mak es the steps easier and helps ensure a cor rect set-up. 2. Fasteners: • Many of the scre ws and bolts on this chair are special high-strength fasteners and ma y hav e special coatings[...]
-
Page 14
26 27 930483 Rev . A 930483 Rev . A IX. SET UP , ADJUSTMENT & USE D .TO FIND & CORRECT A PROBLEM 1 First: Follow steps in this section to mak e sure set-up is cor rect. 2. Second: If step 1 does not work, consult your supplier f or help . 3. If Y ou Still Ha ve A Problem: contact Sunrise Medical Customer Ser vice at (800) 333-4000. E. BA TT[...]
-
Page 15
28 29 930483 Rev . A 930483 Rev . A IX. SET UP , ADJUSTMENT & USE b. Pull up on the armrest pad to the desir ed location. 5.T o Replace: a. Tilt armrest back and insert rear arm tube (3) into receiv er (4). b. Tilt armrest forwar d. This will engage pin to secure rear arm tube. c. Push armrest down until fr ont tube locks in place . K. REAR WHE[...]
-
Page 16
31 930483 Rev . A X. OPERA TING GUIDE 2. T o Program Y our Chair : a. T urn off power to the chair . b. Insert QTR ONIX Programmer plug (A) into the Programmer/Charger sock et (B) on the front of the jo ystick. c. T urn on pow er to the chair ; program as needed. d. Remov e plug and cycle ON/OFF switch to driv e chair . Note: Review the Qtr onix Pr[...]
-
Page 17
33 930483 Rev . A 32 930483 Rev . A Note: If your speed becomes har d to manage , release the J oystick and the chair will come to a complete stop. • When you r elease the joystick it will return to neutral; the chair will slow to a stop and the motor locks will reengage. • W e recommend that y ou switch the chair off if you stop for an y lengt[...]
-
Page 18
35 930483 Rev . A 34 930483 Rev . A • Ne ver place a battery on top of the charger . • Ne ver expose charger to rain or sno w . • Ne ver unplug charger b y pulling on the electrical cord. This will damage the cord. • Nev er open a charger or attempt to repair it yourself. Return charger to Sunrise or ha ve repairs made only b y a qualified [...]
-
Page 19
37 930483 Rev . A 36 930483 Rev . A XI. BA TTERIES 3. Never use an e xtension cord. Use of an impr oper cord could damage the charger , or cause a fire or electrical shock. 4. Do not use charger if it has been dropped or damag ed. 5. A batter y emits explosive h ydro gen gas during charging. T o reduce the risk of fir e or explosion: • Make sur e[...]
-
Page 20
39 930483 Rev . A 38 930483 Rev . A D . BA TTER Y MAINTENANCE 1. T o pre vent an acid spill, alwa ys keep batteries upright. 2. Never smok e or hold an open flame near batteries. 3. Always w ear rubber glov es and safety glasses when you handle batteries. 1. Maintenance Schedule: This varies for differ ent types of batteries. Alwa ys follow the ins[...]
-
Page 21
41 930483 Rev . A 40 930483 Rev . A XII. MAINTENANCE 2. 12" Drive Wheels: a. Elevate and securel y suppor t chair so that wheel is off the ground. Release all air from tir e . b. Remov e plastic dome plug. c. Remove lock n ut and tab washer . d. Remov e wheel. e. Repair or replace inner tube. f. Install wheel on chair b y replacing center tab [...]
-
Page 22
43 930483 Rev . A 42 930483 Rev . A XIV . SUNRISE LIMITED W ARRANTY 1. FOR 5 YEARS W e warrant the main frame of this wheelchair against defects in materials and workmanship f or 5 years after the first consumer pur chase . 2. ADDITIONAL W ARRANTY W e warrant Sunrise-made components of this wheelchair against defects in materials and workmanship as[...]
-
Page 23
Sunrise Medical 7477 East Dry Creek Parkway • Longmont, Colorado • 80503 USA (800) 333-4000 In Canada (800) 263-3390 Manufactured under one or mor e of the following patents: U.S. Patent # 5,062,677; 5,149,173; 5,211,446; 5,352,023; 5,407,248; plus other foreign patents. © 2002, Sunrise Medical 12.02 930483 Rev . A[...]