Teledyne 3300PA manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 36 pages
- 0.24 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Oxygen Equipment
Teledyne 3000ZA
81 pages 3.18 mb -
Oxygen Equipment
Teledyne UFO-130
7 pages 0.28 mb -
Oxygen Equipment
Teledyne 311-D
18 pages 0.74 mb -
Oxygen Equipment
Teledyne 356WA
42 pages 0.32 mb -
Oxygen Equipment
Teledyne P/NM70946
72 pages 0.95 mb -
Oxygen Equipment
Teledyne Percent Oxygen Analyzer
51 pages 0.99 mb -
Oxygen Equipment
Teledyne 3000ZA-3X
72 pages 1.15 mb -
Oxygen Equipment
Teledyne 3110
52 pages 2.42 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Teledyne 3300PA. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Teledyne 3300PA ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Teledyne 3300PA décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Teledyne 3300PA devrait contenir:
- informations sur les caractéristiques techniques du dispositif Teledyne 3300PA
- nom du fabricant et année de fabrication Teledyne 3300PA
- instructions d'utilisation, de réglage et d’entretien de l'équipement Teledyne 3300PA
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Teledyne 3300PA ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Teledyne 3300PA et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Teledyne en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Teledyne 3300PA, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Teledyne 3300PA, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Teledyne 3300PA. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
i Teledyne Analytical Instruments OPERA TING INSTR UCTIONS FOR Model 3300P A P ercent Oxygen Analyzer HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM. PERSONAL PROTECTIVE EQUIPMENT MAY BE REQUIRED WHEN SERVICING THIS SYSTEM. HAZARDOUS VOLTAGES EXIST ON CERTAIN COMPONENTS INTERNALLY WHICH MAY PERSIST FOR A TIM[...]
-
Page 2
ii Teledyne Analytical Instruments Copyright © 1999 Teledyne Analytical Instruments All Rights Reserved. No part of this manual may be reproduced, transmitted, tran- scribed, stored in a retrieval system, or translated into any other language or computer language in whole or in part, in any form or by any means, whether it be electronic, mechanica[...]
-
Page 3
iii Teledyne Analytical Instruments Contents Introduction 1.1 Overview ........................................................................ 1-1 1.2 Main Features of the Analyzer ....................................... 1-1 1.3 F ront P anel Descr iption .................................................. 1-2 1.4 Rear P anel Description ..........[...]
-
Page 4
iv Teledyne Analytical Instruments 4.4.1 Al ar m 1 .................................................................. 4-3 4.4.2 Al ar m 2 .................................................................. 4-3 4.4.3 Sensor F ail Alar m .................................................. 4-4 4.5 Selecting a Fixed Range or Autoranging .................[...]
-
Page 5
v Teledyne Analytical Instruments COMBUSTIBLE GAS USA GE W ARNING D ANGER This is a general purpose instrument designed for usage in a nonhazardous area. It is the customer's responsibility to ensure safety especially when combustible gases are being analyzed since the potential of gas leaks always exist. The customer should ensure that the pr[...]
-
Page 6
vi Teledyne Analytical Instruments This page left intentionally blank[...]
-
Page 7
1-1 Percent Oxygen Analyzer Introduction 1 Teledyne Analytical Instruments Introduction 1.1 Overview The Teledyne Electronic Technologies Analytical Instruments (TETAI) Model 3300PA is a microprocessor-based percent oxygen analyzer for real- time measurement of the percent of oxygen in inert gases, or in a wide variety of gas mixtures. It features [...]
-
Page 8
1-2 1 Introduction Model 3300 PA Teledyne Analytical Instruments • Operator can select Autoranging, which allows the analyzer to automatically select the proper preset range for a given measurement, or he can lock the analyzer onto a single range. • Two concentration alarms with adjustable setpoints. • Sensor failure alarm. • Three analog o[...]
-
Page 9
1-3 Percent Oxygen Analyzer Introduction 1 Teledyne Analytical Instruments • Set Alarm 2 Sets the Alarm 2 Hi or Low, and the concentration to which alarm 2 activates. • Set HI Range Set the high analysis range for the instrument (up to 0-25 %). • Set LO Range Set the low analysis range for the instrument (down to 0-1 %). • Span Span calibra[...]
-
Page 10
1-4 1 Introduction Model 3300 PA Teledyne Analytical Instruments • Power Connection 100 – 240 V ac, at 50/60 Hz. The connector housing includes the fuse holder and the power switch. Fuse Holder: Replacing the fuse is described in Chapter 5, Maintenance . I/O Power Switch: Turns the instrument power ON (1) or OFF (0). • Analog Outputs 0 – 10[...]
-
Page 11
2-1 Percent Oxygen Analyzer Operational Theory 2 Teledyne Analytical Instruments Operational Theory 2. 1 Introduction The analyzer is composed of two subsystems: 1. Analysis Unit with Micro-Fuel Cell Sensor 2. Control Unit with Signal Processing, Display and Controls The Analysis Unit is designed to accept the sample gas and direct it to the sensit[...]
-
Page 12
2-2 2 Operational Theory Model 3300 PA Teledyne Analytical Instruments Micro-Fuel Cell is therefore a hybrid between a battery and a true fuel cell. (All of the reactants are stored externally in a true fuel cell.) 2.2.2 A natomy of a Micro-Fuel Cell The Micro-Fuel Cell is made of extremely inert plastic (which can be placed confidently in practica[...]
-
Page 13
2-3 Percent Oxygen Analyzer Operational Theory 2 Teledyne Analytical Instruments The space between the active elements is filled by a structure saturated with electrolyte. Cathode and anode are wet by this common pool. They each have a conductor connecting them, through some electrical circuitry, to one of the external contacts in the connector rec[...]
-
Page 14
2-4 2 Operational Theory Model 3300 PA Teledyne Analytical Instruments If the pressure changes, the rate that oxygen reaches the cathode through the diffusing membrane will also increase. The electron transfer, and therefore the external current, will increase, even though the proportion of oxygen has not changed. Fortunately, Dalton's Law con[...]
-
Page 15
2-5 Percent Oxygen Analyzer Operational Theory 2 Teledyne Analytical Instruments 2.3 Electronics 2.3.1 General The signal processing uses an Intel microcontroller with on-board RAM and ROM to control all signal processing, input/output, and display functions for the analyzer. System power is supplied from a universal power supply module designe[...]
-
Page 16
2-6 2 Operational Theory Model 3300 PA Teledyne Analytical Instruments In the presence of oxygen the cell generates a current. This current flows through an internal thermistor compensation network. The output of the sensor is converted to voltage in the millivolt range. This output is fed to a voltage amplifier. The internal thermistor network pro[...]
-
Page 17
3-1 Percent Oxygen Analyzer Installation 3 Teledyne Analytical Instruments Installation of the analyzer includes: 1. Unpacking the system. 2. Mounting the Control Unit to a 19" Rack. 3. Installing the Micro-Fuel Cell. 4. Making the electrical connections. 5. Making the gas connections. 6. Testing the installation. CAUTIONS: Read this chapter i[...]
-
Page 18
3 Installation Model 3300 PA 3-2 Teledyne Analytical Instruments 3 . 2 Location and Mounting 3.2.1 Control Unit Installation The 3300PA Control Unit is designed to be rack mounted in a general purpose, indoor area, away from moisture and the elements. The unit should be installed at viewing level in a sheltered area. Refer to the Outline diagram D-[...]
-
Page 19
3-3 Percent Oxygen Analyzer Installation 3 Teledyne Analytical Instruments Primary Input Power: The power cord receptacle, fuse block and Power switch are located in the same assembly. A 6-foot, standard AC power cord is supplied with the Control Unit. Insert the female plug end of the power cord into the power cord receptacle. The universal power [...]
-
Page 20
3 Installation Model 3300 PA 3-4 Teledyne Analytical Instruments Figure 3-2: Contact ID for FAILSAFE Relay Operation The specific descriptions for each type of alarm are as follows: Alarm #1 Programmable as high or low alarm. Can be set any- where between 0 and 25 %. Alarm #2 Programmable as high or low alarm. Can be set any- where from 0 to 25 %. [...]
-
Page 21
3-5 Percent Oxygen Analyzer Installation 3 Teledyne Analytical Instruments atmospheric pressure. Restricting the sample vent line will result in pressur- izing the sensor and altering the O 2 reading. The pressure required will depend on the sampling system. When venting into a constant pressure, such as the atmosphere, controlling input pressure i[...]
-
Page 22
3 Installation Model 3300 PA 3-6 Teledyne Analytical Instruments pump by-pass valve to limit the maximum flow rate to full scale on the flowmeter with the flowmeter valve fully open. Adjust the analyzer flow control valve (flowmeter valve) to a flow-rate of approximately 2 SCFH). Select Span and verify that the span and Sample gas are at different [...]
-
Page 23
Percent Oxygen Analyzer Operation 4 4-1 Teledyne Analytical Instruments Operation 4. 1 Introduction Once the analyzer has been mounted, the gas lines connected and the electrical connections made, the Analyzer can be configured for your appli- cation. This involves setting the system parameters: • Defining the user selectable analysis ranges. •[...]
-
Page 24
4 Operation Model 3300 PA 4-2 Teledyne Analytical Instruments 4 . 2 Using the Function and Data Entry Buttons When no buttons on the Analyzer are being pressed, the instrument is in the Analyze mode. It is monitoring the percent of oxygen in the sample gas that is flowing through the Remote Probe. When one of the Function Buttons is being pressed, [...]
-
Page 25
Percent Oxygen Analyzer Operation 4 4-3 Teledyne Analytical Instruments 4.3.1 H I Range Setting the HI Range fullscale value defines the LEAST sensitive analysis range to be used. To set the HI Range: 1. Press the SET HI RANGE Function button once. 2. Immediately (within 5 seconds) press either the ∆ or ∇ button to raise or lower the displayed [...]
-
Page 26
4 Operation Model 3300 PA 4-4 Teledyne Analytical Instruments until the display reads the desired percent concentration. (if within 5 seconds no key is pressed, the instrument will return to the sample mode and display oxygen concentration). After setting the value wait for the unit to time out of this mode (ap- proximately 5 seconds) and return to[...]
-
Page 27
Percent Oxygen Analyzer Operation 4 4-5 Teledyne Analytical Instruments 4 . 5 Selecting a Fixed Rang e or A utoranging The Model 3300PA can operate in fixed high, fixed low, or autoranging mode. To change modes: 1. Press and then release the SET HI RANGE and the SET LO RANGE buttons simultaneously. 2. Immediately (within 5 seconds) press either the[...]
-
Page 28
4 Operation Model 3300 PA 4-6 Teledyne Analytical Instruments Note: When you stop pressing the UP/DOWN keys, the rapid flashing will cease and the new span value will be acquired by the analyzer after five seconds. The alarms will only be nonresponsive for 60 seconds. This time- frame allows you to reintroduce sample gas into the analyzer. 5. Immed[...]
-
Page 29
5-1 Percent Oxygen Analyzer Maintenance 5 Teledyne Analytical Instruments Maintenance Aside from normal cleaning and checking for leaks at the gas connections, the Model 3300PA should not require any maintenance beyond replacement of expended Micro-Fuel Cells, and perhaps a blown fuse. Routine maintenance includes occasional recalibration, as descr[...]
-
Page 30
5-2 5 Maintenance Model 3300 PA Teledyne Analytical Instruments fuse holder will slide out. There are two fuses in use and are visible in the clip. 4. Remove the bad fuse and replace it with a 5x20mm 0.5 A, 250 VAC, IEC time lag (T) fuse (P /N F1128). 5. Replace the fuse holder into its receptacle, pushing in firmly until it clicks. 5 . 2 Sensor In[...]
-
Page 31
5-3 Percent Oxygen Analyzer Maintenance 5 Teledyne Analytical Instruments ted to enter, cell-life will be compromised. WARNING: The sensor used in the Model 3300PA uses electrolytes which contain substances that are extremely harmful if touched, swallowed, or inhaled. Avoid contact with ANY fluid or powder in or around the unit. What may appear to [...]
-
Page 32
5-4 5 Maintenance Model 3300 PA Teledyne Analytical Instruments CAUTION: D o not scratch, puncture, or damage the sensing membrane of the Micro-Fuel Cell sensor. Damage to the membrane will require replacement of the sensor. 1. Disconnect the Power Source from the Unit. 2. Remove the new Micro-Fuel Cell from its protective bag, being careful not to[...]
-
Page 33
A-1 Percent Oxygen Analyzer Appendix Teledyne Analytical Instruments Appendix A. 1 Specifications Ranges : 0-3 % and 0-10 % oxygen (Standard Ranges), and 0-25 % (nominal) Calibration Range. User selectable % Ranges can be set between 1% and 25 % oxygen (optional 100% range). Signal Output : Voltage: 0 – 10 V dc, negative ground Current: 4-20 mA, [...]
-
Page 34
A-2 Appendix Model 3300 PA Teledyne Analytical Instruments A . 2 Spare P ar ts List QTY. P/N DESCRIPTION 1 C-65220E PC Board, Main 1 C-65220F PC Board, Main for 0-100% range. 1 C-64586C PC Board, Power Supply, AC Version 1 C-44611-I-22 Micro-Fuel Cell, I-22 2 F-1128 Fuse (AC), ½ A, 250 VAC, IEC Type T 1 F-274 Flowmeter 0.3-3.0 SCFH IMPORTANT: Orde[...]
-
Page 35
A-3 Percent Oxygen Analyzer Appendix Teledyne Analytical Instruments A . 3 Reference Drawing D-69127 Final Assembly (and interconnection diagram) D-69220 Outline Diagram A.4 Miscellaneous The symbol: ~ is used on the rear panel of the model 3300PA to signify volts alternating current (V ac). NOTE: The MSDS on this material is available upon request[...]
-
Page 36
A-4 Appendix Model 3300 PA Teledyne Analytical Instruments[...]