Toro Plus Series Satellite manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 19 pages
- 0.4 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Marine Radio
Toro 53799
2 pages 0.28 mb -
Sprinkler
Toro TDC-100/200
20 pages 0.66 mb -
Lawn mower
Toro 74846 - Titan ZX4800
60 pages 4.56 mb -
Stroller
Toro 53887
16 pages 3.09 mb -
Lawn mower
Toro 02605 - HoverPro 550
20 pages 1.21 mb -
Lawn Mower
Toro 2600D
186 pages 3.79 mb -
Lawn Mower
Toro 5900
374 pages 37.47 mb -
Lawn Mower
Toro 14AP80RP744
32 pages 2.73 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Toro Plus Series Satellite. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Toro Plus Series Satellite ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Toro Plus Series Satellite décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Toro Plus Series Satellite devrait contenir:
- informations sur les caractéristiques techniques du dispositif Toro Plus Series Satellite
- nom du fabricant et année de fabrication Toro Plus Series Satellite
- instructions d'utilisation, de réglage et d’entretien de l'équipement Toro Plus Series Satellite
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Toro Plus Series Satellite ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Toro Plus Series Satellite et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Toro en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Toro Plus Series Satellite, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Toro Plus Series Satellite, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Toro Plus Series Satellite. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Controller Components ................................................. 2 Selecting Control Options ............................................ 3 Before Programming the Controller… ..........................4 About The Controller’s Memory ................................... 4 Set Satellite Operating Mode .......................................[...]
-
Page 2
CONTROLLER COMPONENTS 2 Address % Adjust Time/Day Week 1 Central Stand Alone Off Cycle Syringe Multi Manual Start Times Active Days Run Times ENTER START EXIT STOP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Week 2 R LTC TM Tu Programs Plus 1. Control Panel Assembly 2. Pump/Common Output Module 3. Power Indicator Lamp – (5V) Control Functions 4. 8-Station O[...]
-
Page 3
Selecting Control Options A set of eight DIP switches, located beneath the upper left corner of the control panel (as illustrated below) is provided for the selection of optional control characteristics. Power to the controller must be turned Off and the control panel removed from the cabinet in order to make switch position changes. When power is [...]
-
Page 4
Before Programming the Controller … Please note the following important information before programming the Network LTC Plus con- troller for the first time. Although the controller is quite easy to program, it does have some pro- gramming and operating characteristics which will be helpful to know before starting. • *If power is interrupted to [...]
-
Page 5
Set Current Time and Day Synchronizing the controller's clock with the current time and day is an important first step in the programming procedure. The timed events for all watering programs (when the satellite is in the Satellite Mode) are based on the settings you will make here. Use the following procedure to set the current time and day: [...]
-
Page 6
Set Program Start Time(s) This procedure will determine when each program will start during a 24 hour period. Note the following characteristics: • Each program can have from 1 to 12 start times. • Start times can be set to the minute. • Program operation can be prevented for any of the 12 start times by selecting OFF (no start time). • Whe[...]
-
Page 7
Set Active Day W atering Schedules The active watering days for each program can be chosen using a Calendar schedule or an Interval schedule. The Calendar schedule enables active days to be selected within a 14-day (two week) cycle. The Interval Schedule enables active days to be selected by a specific interval, such as every day, every-other day, [...]
-
Page 8
Interval Schedule Scheduling active days by Interval enables a program to operate on a specific routine such as, every other day, or every fourth day, without regard to actual calendar days. The Interval schedule consists of two programmable numbers: The Interval Reference and the Interval Day. The Interval Reference number (01 – 29) determines h[...]
-
Page 9
Set Program Repeat and Soak This is an optional programming feature which enables a program to repeat its operating cycle from 0 – 3 times (in addition to its initial cycle). A soak-in period from 0 – 59 minutes is placed between repeat cycles. 1. Press as needed to select the Program indicator. 2. Press or until the desired program number (1 ?[...]
-
Page 10
Program Operation Pause and Cancel An operating program can be paused or canceled at any time as needed. The pause feature temporarily suspends program operation for up to 10 minutes. When operation resumes, the program continues from the point of interruption without loosing station run time. Use the cancel feature to terminate the program operati[...]
-
Page 11
Syringe Mode The Syringe mode enables all stations with a programmed run time in a selected program to be operated for a short, temporary run time (syringe). The amount of run time for the syringe operation can be set from 1 – 30 minutes or by a percentage of programmed station run time from 10% – 99%. To syringe all stations from 1 – 30 minu[...]
-
Page 12
Multi-Manual Mode Up to six selected stations can be operated at the same time using Multi-Manual mode. A temporary run time from 1 to 59 minutes is given to each station for this operation. Caution: Prior to Multi-Manual operation, ensure that combined current draw of all stations operating at the same time (including pump relay) does not exceed 3[...]
-
Page 13
Set Satellite Address The LTC satellite requires a unique address for identification by the central LCM within the network system. The address consists of a group number (1 – 50) and satellite number (1 – 500). A combination of up to 500 satellites may be defined. Satellites may only be assigned to one group. However, the same satellite number [...]
-
Page 14
Reviewing Program Information To review the current operating information entered for any program, use the procedure below. If you need to make changes to any portion of a program or the Time/Day setting, refer to the appropriate procedure in the programming section of this manual. 1. Press to select the Program number indicator. 2. Press or as nee[...]
-
Page 15
Radio Calibration T est The radio calibration test enables the LTC to generate three different radio test patterns for use in radio network communications setup. If a radio is not connected, no indication is seen on the TM. The test patterns can be monitored by connecting an oscilloscope or headphones to the modem 2-wire connector. To Perform Radio[...]
-
Page 16
T roubleshooting If you experience a controller problem, check the programming for a possible programming error and the list of problems and solutions listed below. If the problem continues, contact your local Toro distributor for assistance. Lithium Battery installation (optional) An optional 3.9V lithium battery (P/N 363-2200) can be installed to[...]
-
Page 17
Manual Output Switch Operation A 3-position switch is provided on the Pump/Com module for additional control of the pump relay circuit. In addition, the optional station terminal modules with optional control switches have one switch for each station output. The three switch positions control the circuits as follows: On – Manually activates the c[...]
-
Page 18
Program Data Reference Form Program Number_____ Date_________ Station Location 1 ___________________ 17 ___________________ 33 ____________________ 49 ____________________ 2 ___________________ 18 ___________________ 34 ____________________ 50 ____________________ 3 ___________________ 19 ___________________ 35 ____________________ 51 _____________[...]
-
Page 19
User's Guide Network L TC TM Plus Series Satellite TM R[...]