Westinghouse Switch manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 12 pages
- 0.7 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Outdoor Ceiling Fan
Westinghouse wh04
24 pages 0.3 mb -
LED TV
Westinghouse WD70UB4580
88 pages 12.02 mb -
Convection Oven
Westinghouse WST3019ZE
23 pages 0.21 mb -
Indoor Furnishings
Westinghouse W-259
12 pages 0.17 mb -
Flat Panel Television
Westinghouse SK-32H240S
47 pages 1.59 mb -
Plumbing Product
Westinghouse ACB-4000HR
44 pages 3.8 mb -
Power Hammer
Westinghouse DB-50
37 pages 2.71 mb -
Flat Panel Television
Westinghouse WD50FC1120
35 pages 15.63 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Westinghouse Switch. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Westinghouse Switch ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Westinghouse Switch décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Westinghouse Switch devrait contenir:
- informations sur les caractéristiques techniques du dispositif Westinghouse Switch
- nom du fabricant et année de fabrication Westinghouse Switch
- instructions d'utilisation, de réglage et d’entretien de l'équipement Westinghouse Switch
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Westinghouse Switch ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Westinghouse Switch et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Westinghouse en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Westinghouse Switch, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Westinghouse Switch, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Westinghouse Switch. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Instruction Leaflet 30-470 (E) Page 1 Westinghouse Canada Switchgear and Control Division October , 1979 Supersedes issue dated October , 1975 Instruction Leaflet 30-470 (E) Pages 1-12 Automatic T ransfer Switches Index Warranty ......................................... 2 Westinghouse Offices ..................... 3 General Description ............[...]
-
Page 2
Instruction Leaflet 30-470 (E) Page 2 Warranty The Company warrants the apparatus to be supplied hereunder to be of the kind designated or specified. The Company shall repair or replace any defective part or parts, f.o.b. the Companys factory , repair shop or warehouse, which prove to be defective under normal and proper use within one year from[...]
-
Page 3
Instruction Leaflet 30-470 (E) Page 3 Westinghouse industrial products, and a complete line of electrical construction products, are distributed across Canada by WESCO (Westinghouse Sales & Distribution Company). For product application, delivery or pricing information call the WESCO office near you. WESCO Sales Offices Abbotsford 859-31 1 1 34[...]
-
Page 4
Instruction Leaflet 30-470 (E) Page 4 General Description CSA Standard C22.2 No. 178-1978 defines an automatic transfer switch as, self acting equipment for transferring one or more load conductor connections from one power source to another . Transfer switch type A means an automatic transfer switch that does not employ integral overcu[...]
-
Page 5
Instruction Leaflet 30-470 (E) Page 5 T ype LRO Robonic Automatic Transfer Switch Rated 30 amperes through 100 amperes at 600 volts Ac maximum 50 or 60 Hertz. The mechanism is a lever operated device controlled by a 120 volt unidirectional motor. The transfer motor drives a nylon cam which in turn operates a steel lever by sliding a pin along a slo[...]
-
Page 6
Instruction Leaflet 30-470 (E) Page 6 T ype RO Robonic Automatic Transfer Switch A complete line rated from 150 amperes through 1000 amperes at 600 volts Ac or at 250 volts Dc. The transfer mechanism consists of the transfer motor , a gear train and two breaker operating cams. Spur Gear Meshing Relationship ( bottom view of top cover) The tra[...]
-
Page 7
Instruction Leaflet 30-470 (E) Page 7 T able 1 Interrupting, Closing and Withstand Rating Robonic T ype A Robonic Continuous rms symmetrical amperes Rating 600 Vac 480 Vac 120,208,240 Vac 30 to 100 amps 14,00 0 14, 000 18, 000 150 to 1000 amps 22,00 0 30, 000 42, 000 1200 to 3000 amps 100,000 100,000 125,000 Since type A Robonics employ mag[...]
-
Page 8
Instruction Leaflet 30-470 (E) Page 8 Automatic Control ( Continued ) When adjustable type voltage sensors have been ordered, they are factory set to dropout at 90 volts and pickup at 108 volts Ac. For adjustment to other settings, first set the drop value and adjust the pickup to desired setting. This is done by using a variable power supply for t[...]
-
Page 9
Instruction Leaflet 30-470 (E) Page 9 Solid State T ype Ratings 1. 2 wat ts power consumption Input Coil V oltage 120 volts at 50/60 Hertz Contact Rating 10 amperes resistive at 120 volts Time Range 2 to 3 seconds nonadjustable Operating T emperature Range -10°C to +55°C Description This is an octal plug-in relay containin[...]
-
Page 10
Instruction Leaflet 30-470 (E) Page 10 Plant Exerciser (as used in Robonic T ransfer Switches) Ratings Input voltage 120 volts Contact rating 20 amps at 120 volts resistive S.P .D.T . Description Dial A is divided into a 24 hour day and night scale, and has tabs around the periphery which may be adjusted to operate the micro switch within inter[...]
-
Page 11
Instruction Leaflet 30-470 (E) Page 11 Replacing Parts The Robonic Automatic Transfer Switch has been designed to have all components accessible and readily removable from the front of the panels. The Robonic Transfer Switch is divided into two basic sections. The upper section consists of the main contacts and transfer mechanism, the lower section[...]
-
Page 12
Instruction Leaflet 30-470 (E) Page 12 T rouble Shooting Guide Symptoms refusal to re-transfer to normal source upon restoration will not transfer to emergency source upon failure of normal source transfer without a power failure in the normal source no time delay when there should be engine-generator starts when the normal sour[...]