Whirlpool W10123251 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 32 pages
- 1.6 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Water Heater
Whirlpool 211458
28 pages 2.28 mb -
Water Heater
Whirlpool BFG1F5040T3NOV 5K
28 pages 2.28 mb -
Water Heater
Whirlpool 201553
29 pages 1.56 mb -
Water Heater
Whirlpool 140422
16 pages 0.58 mb -
Water Heater
Whirlpool 315420-000
32 pages 1.85 mb -
Water Heater
Whirlpool UG1J4040T3NOV
29 pages 1.56 mb -
Water Heater
Whirlpool UG2H4040T3NV EST
29 pages 1.56 mb -
Water Heater
Whirlpool 140426
16 pages 0.58 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Whirlpool W10123251. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Whirlpool W10123251 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Whirlpool W10123251 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Whirlpool W10123251 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Whirlpool W10123251
- nom du fabricant et année de fabrication Whirlpool W10123251
- instructions d'utilisation, de réglage et d’entretien de l'équipement Whirlpool W10123251
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Whirlpool W10123251 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Whirlpool W10123251 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Whirlpool en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Whirlpool W10123251, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Whirlpool W10123251, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Whirlpool W10123251. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
1 Ultra Low Nox Gas W ater Heater with the Flame Lock™ Safety System Installation Instructions and Use & Care Guide Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHA T TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do no[...]
-
Page 2
2 Important Instructions • Do not use this appliance if any part has been under water . Immediately call a qualified service technician. W ater heaters subjected to flood conditions or any time the gas controls, main burner or pilot have been submerged in water require replacement of the entire water heater . • Hydrogen gas can be produced in a[...]
-
Page 3
3 INST ALLING YOUR GAS W A TER HEA TER Important Information About This W ater Heater This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident. New technology used in meeting these standards makes this product more sensitive to installation errors or improper installation e[...]
-
Page 4
4 Location Requirements The Flame Lock™Safety System is designed to reduce the risk of flammable vapor-related fires. The patented system protects your family by trapping the burning vapors within the water heater combustion chamber through the special flame-trap. The burning vapors literally “burn themselves out” without escaping back into t[...]
-
Page 5
5 IMPORT ANT : The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the water heater or to lower floors of the structure. Due to the normal corrosive action of the water , the tank will eventually leak after an extended period of time. Also any external plumbing lea[...]
-
Page 6
6 Gas Supply Gas Requirements IMPORT ANT : Read the data plate to be sure the water heater is made for the type of gas you will be using in your home. This information will be found on the data plate located near the gas control valve/thermostat. If the information does not agree with the type of gas available, do not install or light. Call your de[...]
-
Page 7
7 Nominal Iron Pipe Length of Pipe, Feet Size, in. 1/2 3/4 1 1-1/4 1-1/2 132 278 520 1050 1600 92 190 350 730 1 100 73 152 285 590 890 63 130 245 500 760 56 11 5 215 440 670 50 105 195 400 610 46 96 180 370 560 43 90 170 350 530 40 84 160 320 490 38 79 150 305 460 34 72 130 275 410 31 64 120 250 380 28 59 11 0 225 350 26 55 100 210 320 10 20 30 40 [...]
-
Page 8
8 Unconfined Space A water heater in an unconfined space uses indoor air for combustion and requires at least 50 cubic feet for each 1,000 BTUH of the total input for all gas appliances. The table below shows a few examples of the minimum square footage (area) required for various BTUH inputs. 30,000 45,000 60,000 75,000 90,000 105,000 120,000 135,[...]
-
Page 9
9 All Air from Outdoors Outdoor fresh air can be provided to a confined area either directly or by the use of vertical and horizontal ducts. The fresh air can be taken from the outdoors or from crawl or attic spaces that freely communicate with the outdoors. Attic or crawl spaces cannot be closed and must be properly ventilated to the outside. Duct[...]
-
Page 10
10 V ent Pipe System This water heater uses a non-direct, single-pipe vent system to remove exhaust gases created by the burning of fossil fuels. Air for combustion is taken from the immediate water heater location or is ducted in from the outside (see “Combustion Air Supply and V entilation” section). This water heater must be properly vented [...]
-
Page 11
11 Chimney Connection IMPORT ANT : Before connecting a vent to a chimney , make sure the chimney passageway is clear and free of obstructions. The chimney must be cleaned if previously used for venting solid fuel appliances or fireplaces. Also consult local and state codes for proper chimney sizing and application or , in the absence of local and s[...]
-
Page 12
12 W ater System Piping Piping, fittings, and valves should be installed according to the installation drawing (Figure 13). If the indoor installation area is subject to freezing temperatures, the water piping must be protected by insulation. W ater supply pressure should not exceed 80% of the working pressure of the water heater . The working pres[...]
-
Page 13
13 Please note the following: • The system should be installed only with piping that is suitable for potable (drinkable) water such as copper , CPVC, or polybutylene. This water heater must not be installed using iron piping or PVC water piping. • Use only pumps, valves, or fittings that are compatible with potable water . • Use only full flo[...]
-
Page 14
14 For protection against excessive pressures and temperatures, a temperature and pressure relief valve must be installed in the opening marked “T & P RELIEF V AL VE” (see Figure 15A). This valve must be design certified by a nationally recognized testing laboratory that maintains periodic inspection of the production of listed equipment or[...]
-
Page 15
15 Special Applications Combination Space Heating/Potable W ater System Some water heater models are equipped with inlet/outlet tappings for use with space heating applications. If this water heater is to be used to supply both space heating and domestic potable (drinking) water , the instructions listed below must be followed. • Be sure to follo[...]
-
Page 16
16 W ater Heater Location W ater heater location is important and can affect system performance. Please check the following: □ Installation area free of corrosive elements and flammable materials. □ Centrally located with the water piping system. Located as close to the gas piping and vent pipe system as possible. □ Located indoors and in a v[...]
-
Page 17
17 OPERA TING YOUR W A TER HEA TER Lighting Instructions Read and understand these directions thoroughly before attempting to light or re-light the pilot. Make sure the viewport is not missing or damaged. (See Figure 23) Make sure the tank is completely filled with water before lighting the pilot. Check the data plate near the gas control valve/the[...]
-
Page 18
18 Checking the Draft After successfully lighting the water heater , allow the unit to operate for 15 minutes and check the draft hood relief opening for proper draft. Make sure all other appliances in the area are operating and all doors are closed when Burn Hazard Do not touch vent. Doing so can result in burns. W ARNING White Rodgers Gas V alve [...]
-
Page 19
19 The thermostat is adjusted to its lowest temperature when it is shipped from the factory . Water temperature can be regulated by moving the temperature dial to the preferred setting. The preferred starting point is 120°F . Align the index bar on the thermostat with the desired water temperature as shown in Figure 19. There is a hot water scald [...]
-
Page 20
20 Operational Conditions Condensation Moisture from the products of combustion condenses on the tank surface and the outside jacket of the water heater and forms drops of water which may fall onto the burner or other hot surfaces. This will produce a “sizzling” or “frying” noise. NOTE: This condensation is normal and should not be confused[...]
-
Page 21
21 MAINTENANCE OF YOUR W A TER HEA TER Draining and Flushing It is recommended that the tank be drained and flushed every 6 months to remove sediment which may build up during operation. The water heater should be drained if being shut down during freezing temperatures. T o drain the tank, perform the following steps: 1. T urn off the gas to the wa[...]
-
Page 22
22 Replacement Parts IMPORT ANT : The following maintenance procedures are for the Flame Lock™Safety System components and should be performed by a qualified person. Replacement parts may be ordered through your plumber or the local distributor . Parts will be shipped at prevailing prices and billed accordingly . When ordering replacement parts, [...]
-
Page 23
23 Replacing the Thermocouple 1. Remove the Burner Door Assembly as directed previously . 2. Remove the retainer clip from the back of the two piece wire connector and remove the two piece wire connector from the assembly (Figure 25). 3. Pull the thermocouple from the pilot assembly (Figure 29). IMPORT ANT : Be careful not to bend or alter the posi[...]
-
Page 24
24 Replacing the Burner Door Assembly 1. Check the door gasket for damage or imbedded debris prior to installation. Piezoelectric Igniter System The piezoelectric igniter system consists of the igniter button, electrode, and wire. The pilot is ignited by an electric spark generated when the igniter button is pressed. The electrode should be centere[...]
-
Page 25
25 Removing and Replacing the Gas Control V alve/Thermostat IMPORT ANT : The gas control valve/thermostat is a standard valve with a right-hand thread thermocouple. Use only factory authorized replacement parts. Removing the Gas V alve: 1. Turn the gas control knob on the combination gas control valve/thermostat clockwise to the “OFF” position.[...]
-
Page 26
26 PROBLEM POSSIBLE CAUSE(S) CORRECTIVE ACTION PILOT WILL NOT REMAIN LIT 1 . Air in gas line 2. Dirt in gas lines 3. Pilot line or orifice clogged 4. Thermocouple connection loose 5. Non-functioning thermocouple 6. Cold drafts 7. Flammable vapors incident, Flame Lock TM function utilized 8. Low gas pressure 9. Air for combustion obstructed 10. Pilo[...]
-
Page 27
27 PILOT LIGHT TROUBLESHOOTING CHART Have you bled all the air from the pilot tube and gas supply line? NO While repeatedly depressing the igniter button, hold down the reset button until the pilot is lit and maintains a stable flame, then slowly release the reset button. YES Section A: Pilot light will not light. Section B: Pilot light will not re[...]
-
Page 28
28 Item No. Parts Description 1 DRAFT HOOD 2 REDUCER RING - SOME MODELS 3 FLUE BAFFLE 4 HEA T TRAP (COLD) - SOME MODELS 5 HEA T TRAP (HOT) - SOME MODELS 6A COLD W A TER DIP TUBE 6B COLD W A TER DIP TUBE 7 ANODE ROD 8 TEMPERA TURE & PRESSURE RELIEF V AL VE (LOCA TED TOP OR SIDE) 9 DRAIN V AL VE 10A GAS CONTROL V AL VE/THERMOST A T 10B GAS CONTRO[...]
-
Page 29
29 Listed Parts Kits and Illustrations Item 12: Pilot assembly which contains the pilot assembly and igniter electrode. (Natural Gas) Item 13: Burner Door assembly which contains the burner , gasket, door , pilot tube, two piece wire connector with retainer clip, and pilot assembly . (Natural Gas/Low Nox) Item 14: Contains two piece wire connector [...]
-
Page 30
30[...]
-