ZyXEL Communications 3356P manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 30 pages
- 0.08 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Modem
ZyXEL Communications 630
38 pages 1.12 mb -
Modem
ZyXEL Communications 2602RL-D3A
176 pages 2.86 mb -
Modem
ZyXEL Communications 3356P
30 pages 0.08 mb -
Modem
ZyXEL Communications 3356P-LAN
38 pages 0.11 mb -
Modem
ZyXEL Communications IES-612-51A
444 pages 8.29 mb -
Modem
ZyXEL Communications 2602HWNLI-D7A
246 pages 4.2 mb -
Modem
ZyXEL Communications 841-25
8 pages 0.35 mb -
Modem
ZyXEL Communications n/a
222 pages 1.33 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation ZyXEL Communications 3356P. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel ZyXEL Communications 3356P ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation ZyXEL Communications 3356P décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation ZyXEL Communications 3356P devrait contenir:
- informations sur les caractéristiques techniques du dispositif ZyXEL Communications 3356P
- nom du fabricant et année de fabrication ZyXEL Communications 3356P
- instructions d'utilisation, de réglage et d’entretien de l'équipement ZyXEL Communications 3356P
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage ZyXEL Communications 3356P ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles ZyXEL Communications 3356P et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service ZyXEL Communications en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées ZyXEL Communications 3356P, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif ZyXEL Communications 3356P, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation ZyXEL Communications 3356P. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Comet 3356P User ’ s Manual Version 1.0 ZyXEL A CCESSING THE INTERNET AND INTRANET[...]
-
Page 2
ii Limited Warranty ZyXEL warrants to the original end user (purchaser) that this product is free from any defects in materials or workm anship for a period of up to two (2) years from the date of purchase. During the warranty period, and upon proof of purchase, should the product have indications of failure due to faulty workmanship and/or materia[...]
-
Page 3
iii Changes or modifications not expressly approved by the party responsible for compliance could void the user ’ s authority to operate the equipment. Shielded RS-232 cables are required to be used to ensure compliance with FCC Part 15, and it is the responsibility of the user to provide and use shielded RS-232 cables. FCC Requirements This equi[...]
-
Page 4
iv Outside North America, you can dial +886-3-5783942 EXT 252 between 8:00AM and 5:00PM Taiwan time (GMT +8:00). • Fax : ZyXEL in North America: (714) 693-8811 or Taiwan: +886-3-5782439. • E-mail : • Sales inquiries : sales@zyxel.com in North Am erica. sales@zyxel.com.tw outside North America. • Technical support : support@zyxel.com in Nort[...]
-
Page 5
v Table of Contents Limited Warranty ii FCC Part 15 Information ii FCC Requirements iii Contacting ZyXEL iii 1 Introduction 1 Unpacking Your Modem 1 Hardware Overview 1 Required Equipment 1 2 Installation 3 Windows 95 3 Windows 3.1 & Windows for Workgroups 3 DOS 3 Windows NT 4.0 4 3 Basic Modem Operation 5 Understanding AT Commands 5 Using the [...]
-
Page 6
vi Storing Phone Numbers 9 Dialing Stored Phone Numbers 10 Saving Settings and User Profiles 10 Default Modem Settings for PC’s 10 4 AT Command Set Summaries 13 Basic AT Command Set 13 Extended AT& Command Set 15 Extended AT Command Set 16 Extended AT% Command Set 16 Extended AT- Command Set 17 5 Status Registers & Result Codes 19 Result[...]
-
Page 7
Introduction 1 1 Introduction Congratulations on the purchase of your Comet 3356P Type II PCMCIA card, one of ZyXEL's premier high-performance products. The Com et is world renown for its ability to maintain ultra high speeds and clear, quality connections while communicating around the globe. Unpacking Your Modem Before you proceed, check all[...]
-
Page 8
2 Introduction[...]
-
Page 9
Installation 3 2 Installation This chapter describes installation for Windows 95, Windows 3.1, Windows for Workgroups, and DOS. You can jump directly to the installation procedure for your particular environment. Windows 95 1. Insert the Comet into a free PCMCIA slot. 2. Power on your computer and start Windows 95. 3. Windows 95 will display the Ne[...]
-
Page 10
4 Installation 2. Power on your computer. 3. If you hear an alert sound skip to step 5. If not continue. 4. Use a PCMCIA utility to set your COM port and IRQ information. A PCMCIA utility should have been included with your computer. If not contact your dealer. 5. Install the FAX/MODEM application program that came with your Com et. 6. Connect the [...]
-
Page 11
Basic Modem Operation 5 3 Basic Modem Operation This chapter covers the basic commands and techniques involved in m odem operation. In many cases, this is the only information you will need in order to get your Com et up and running with communication software, and to start m aking connections with your Comet. Understanding AT Commands The Comet co[...]
-
Page 12
6 Basic Modem Operation The next window sets the COM port settings. The settings used for the Comet should be as follows: Bits per second: 115200 Data bits: 8 Parity: None Stop bits: 1 Flow Control: Hardware Click “ OK ” when finished. After you have done this, save your new connection by selecting “ Save ” from the “ File ” menu and cl[...]
-
Page 13
Basic Modem Operation 7 Pausing During Dialing: ATDT 9 ,, 555 1212 Dialing Without Waiting for Dial Tone: AT X0 D, 555 1212 Originating a call using an Answer Tone: ATDT 555 1212,,,,,, R Redialing the Last Number Called: ATD L Waiting for Five Seconds of Silence: ATDT 800 555 1212 @ 123456,1 714 555 1212 Transferring a Call (using flash hook): ATDT[...]
-
Page 14
8 Basic Modem Operation • Multiple AT commands can be com bined into one line. For example, AT&D2 and AT&K0 can be combined into one line AT&D2&K0. The Comet processes comm ands from left to right. The AT comm and that appears to the right might over-write the comm and to the left if they are trying to accomplish tasks or set mode[...]
-
Page 15
Basic Modem Operation 9 Modem Result Codes When you execute or try to execute an AT command, your m odem sends a result code to let you know whether the command was executed. An OK result code m eans the AT command you sent was executed. If you receive an ERROR code, it m eans the command was invalid. The Comet also provides result codes that show:[...]
-
Page 16
10 Basic Modem Operation The ‘ s ’ is a number from 0 to 3 that represents the location in m emory that the phone number is to be stored, and the ‘ n ’ is the phone num ber itself. Example: To store the number ‘ 1-714-555-1212 ’ in mem ory location ‘ 2 ’ , type: AT&Z2=17145551212<Enter> You can store up to 4 telephone numb[...]
-
Page 17
Basic Modem Operation 11 AT Command Description %C1 Use both V.42bis and MNP 5 data compression[...]
-
Page 18
12 Basic Modem Operation[...]
-
Page 19
AT Command Set Sum maries 13 4 AT Command Set Summaries Basic AT Command Set Co mman d Options Function & Descriptio n A/ Re-execute the last command string <any key> Terminate the current connection attempt when entered in handshaking state All the following commands requ ire an “AT” prefix A Go off-hook and attempt to establish a co[...]
-
Page 20
14 AT Command Set Sum maries Co mman d Options Function & Descriptio n M2 Speaker always on M3 Speaker off during dialing and on until carrier present Nn Select negotiate handshake N0 When originating or answering, handshake only at the communication rate specified by S37 register and “ATBn” and no f allback N1 * When originating or answeri[...]
-
Page 21
AT Command Set Sum maries 15 Co mman d Options Function & Descriptio n Z0 Reset and recall user profile 0. Either Z0 or Z1 restores the same single profile. * Manufacturer default Extended AT& Command Set Co mman d Options Function & Descriptio n &Cn Data carrier detect option &C0 State of carrier from remote modem is ignored. D[...]
-
Page 22
16 AT Command Set Sum maries Co mman d Options Function & Descriptio n &W Store active configuration into the modem’ s NVRAM &Zn=x Store telephone number n=0 to 3 x=<string> see also the dial modifier in ”ATDn” command The maximum number of digits per string is 40. * Manufacturer default Extended AT Command Set Co mman d Op[...]
-
Page 23
AT Command Set Sum maries 17 Co mman d Options Function & Description %Cn Data compression control %C0 No data com pression %C1 * V.42bis/MNP 5 data compression enabled. * Manufacturer default Extended AT- Command Set Co mman d Options Function & Description -Cn Data calling tone options -C0 * Disable data calling tone -C1 Enable data calli[...]
-
Page 24
18 AT Command Set Sum maries[...]
-
Page 25
Status Registers & Result Codes 19 5 Status Registers & Result Codes Register Dec. Function & Descriptio n Default S0= 0 - 255 Set the number of the rings required before the m odem automatically answers a call. Set “S0=0” to disable auto- answer mode. 000 S1= 0 - 255 Count the incoming rings and store the value to this register. Th[...]
-
Page 26
20 Status Registers & Result Codes Register Dec. Function & Descriptio n Default 0, 2 Hang up. 1, 3 Fall back to an async connection. 4, 6 Attempt MNP mode. If MNP fails, hang up. 5, 7 Attempt MNP mode. If MNP fails, fallback to async connection.. S37= Desired DCE speed (line speed). 000 0 Maximum modem speed. 2 Attempt 1200/75 bps connecti[...]
-
Page 27
Status Registers & Result Codes 21 Register Dec. Function & Descriptio n Default S36=0 or 2 and S48= 128 Don’t use S36=1 or 3, and S48=7 LAPM or async S36=1 or 3, and S48=128 Async S36=4 or 6, and S48=7 LAPM, MNP or hang up S36=4 or 6, and S48=128 MNP or hang up S36=5 or 7, and S48=7 LAPM, MNP or async S36=5 or 7, and S48=128 MNP or hang [...]
-
Page 28
22 Status Registers & Result Codes ATV0 ATV1 X0 X1 X2 X3 X4 X7 58 CONNECT 28800 EC * # # # # 59 CONNECT 31200 EC * # # # # 60 CONNECT 33600 EC * # # # # 70 CONNECT 32000 EC * # # # # 71 CONNECT 34000 EC * # # # # 72 CONNECT 36000 EC * # # # # 73 CONNECT 38000 EC * # # # # 74 CONNECT 40000 EC * # # # # 75 CONNECT 42000 EC * # # # # 76 CONNECT 44[...]
-
Page 29
Status Registers & Result Codes 23 ATV0 ATV1 W0 W1 W2 W2V0 28 CONNECT 38400 EC * 99 40 CONNECT 300 99 40 CONNECT 300 EC * 99 55 CONNECT 21600 9 55 CONNECT 21600 EC * 9 56 CONNECT 24000 9 56 CONNECT 24000 EC * 9 57 CONNECT 26400 9 57 CONNECT 26400 EC * 9 58 CONNECT 28800 9 58 CONNECT 28800 EC * 9 59 CONNECT 31200 9 59 CONNECT 31200 EC* 9 60 CON[...]
-
Page 30
24 Status Registers & Result Codes MNP4 MNP 4 error c ontrol only NoEC No error control and data control protocols[...]