Vai alla pagina of
Manuali d’uso simili
-
Network Card
ACTiSYS IR2000UL
20 pagine 0.7 mb -
Network Card
ACTiSYS RS232
18 pagine 0.7 mb -
Network Card
ACTiSYS ACT-IR220L+/220L/200L
37 pagine 4.06 mb -
Network Card
ACTiSYS ACT IR100SLM
20 pagine 4.29 mb -
Network Card
ACTiSYS ACT-IR220Li
10 pagine 0.33 mb -
Network Card
ACTiSYS ACT-IR320L
6 pagine 0.35 mb -
Network Card
ACTiSYS ACT-IR100S-L
20 pagine 0.48 mb -
Network Card
ACTiSYS ACT-IR220LN
10 pagine 0.33 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso ACTiSYS ACT-IR100SD. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica ACTiSYS ACT-IR100SD o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso ACTiSYS ACT-IR100SD descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso ACTiSYS ACT-IR100SD dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo ACTiSYS ACT-IR100SD
- nome del fabbricante e anno di fabbricazione ACTiSYS ACT-IR100SD
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature ACTiSYS ACT-IR100SD
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio ACTiSYS ACT-IR100SD non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti ACTiSYS ACT-IR100SD e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio ACTiSYS in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche ACTiSYS ACT-IR100SD, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo ACTiSYS ACT-IR100SD, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso ACTiSYS ACT-IR100SD. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
The W ireless Connectivity Expert 4851 1 W arm Springs Blvd., Suite 206, Fr emont CA 94539 Te l : +1-510-490-8024 F a x : +1-510-623-7268 We b s i t e : http://www .actisys.com/ E-mail: irda-info@actisys.com ACT -IR100SD OBEX Server IrReady Intelligent Adapter User ’ s Manual October 30, 2006 V er . 1.0 © Copyright 2000-2006 ACTiSYS Corporation [...]
-
Pagina 2
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 7. ACT -IR100SD DONGLE DIMENSIONS .............................................................. 17 V ersion 1.0 T ABLE OF CONTENTS REVISION H ISTOR Y ............................................................................................... 3 PRECAUTIONS ............[...]
-
Pagina 3
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual REVISION HIST OR Y Revision History Revision Date Comment 1.0 10/30/2006 Draft Preliminary Design S pecification. Copyright 2000-2006 ACT iSYS Corp. Page 3 of 17 Oct 30, 2006 V ersion 1.0[...]
-
Pagina 4
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual PRECAUTIONS T o ensure trouble-free operation, please observe the following precautions: Optical communications are easily affected by exte rnal light sources, weak batteries, transfer distance, transfer angle, etc. Any of these conditions may cause a data transfer failure[...]
-
Pagina 5
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 1. FEA TURES A complete IrDA Protocol stack in a dongle. Supports both IrDA Primary and Secondary mode, changeable via PC utility . No driver program is needed. Supports mandatory IrDA layer: IrPHY , IrLAP , IrLMP and IAS. Supports upper layers T inyTP [...]
-
Pagina 6
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 2. OVERVIEW The ACT -IR100SD is a high-integration IrDA Intelligent dongle. It provides a seria l interface to a host device that intends to have Infrared communication capability . The host device can be any equipment or device that needs to communicate with IrDA enabled [...]
-
Pagina 7
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 3. ARCHITECTURE OF ACT -IR100SD The mandatory IrDA protocol layers, IrLAP and IrLMP (including IAS) are handled by ACT -I R100SD, In addition, T i nyTP , IrCOMM, IrLPT and OBEX transport are also included. The incoming/outgoing IrDA user data p ayload are buffered and then[...]
-
Pagina 8
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual Copyright 2000-2006 ACT iSYS Corp. Page 8 of 17 Oct 30, 2006 4. HOST INTERF ACE The host interface of ACT -IR100SD is a full-duplex asynchronous RS232 DB9M connector . The following table is the signals of D B9M connector . It can be treated as DTE. The data bytes are [...]
-
Pagina 9
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 4.1 Host Interface Signals ACT -IR100SD host interface consists of three output signals and five input signals. All these signals are low active. That is, they are at 0V when active and at VCC level when inactive. When an inverting RS232 level converter is used, the corres[...]
-
Pagina 10
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual Copyright 2000-2006 ACT iSYS Corp. Page 10 of 17 Oct 30, 2006 V ersion 1.0 5. OPERA TING IN ACT -IR100SD 5.1 How T o Connect IR100SD With Host Device: IR100SD uses a standard RS232 DTE port to connect with the host. If the host device is a Modem like device and has a R[...]
-
Pagina 11
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.2.1 The first page is to set the host baud rate and the hardware flow control. Please Note: Ignore CTS: If host device has no hardware flow control signals, only Tx, Rx and GND, then you have to set this bit to 1. IR100SD will pass the coming dat a to host and doesn’t [...]
-
Pagina 12
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.2.2 The second page is to set time interval of discovery , the slot number of discovery and the mode of IR100SD. 1) IR100SD supports both Primary and Secondary . It allows customer to change it. 2) Discovery time should be 3 seconds in general. If you want the discovery [...]
-
Pagina 13
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.2.3 The third page is to set the IrDA protocols when IR100SD is in Primary . Copyright 2000-2006 ACT iSYS Corp. Page 13 of 17 Oct 30, 2006 V ersion 1.0[...]
-
Pagina 14
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.3 OBEX PUT/GET Description The OBEX specification consist s of two major part s: a protocol and an application framework. This is also illustrated graphically below . The "application framework" is represented in ellipses inside the "wide word of applicati[...]
-
Pagina 15
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual The following figure shows how cellphone or PDA delivers an object (maybe a phone book record, a picture or a formatted data) to user’s host. W hen IR100SD-OBEX-Server receives OBEX PUT command, it will act like a PUT ser ver and reply proper response. Then it will trim [...]
-
Pagina 16
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual Frame length means total frame size, including byte 0,1, 2, and 3. For example, if dat a frame is 300 bytes, length should be 304. 6. THE DEF AUL T SETTING OF ACT -IR100SD The default setting of ACT -IR100SD is configured as the following: Parameters Setting Host baud rate[...]
-
Pagina 17
The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual Copyright 2000-2006 ACT iSYS Corp. Page 17 of 17 Oct 30, 2006 7. ACT -IR100SD DONGLE DIMENSIONS 8. CHARACTERISTICS AND SPECIFICA TION Parameter Min. T ypical Max. Unit s DC supply v oltage 6.0 7.5 12 V Supply v oltage, VSS 0 V Operating temperature range, TA 0 60 ℃ D[...]