Vai alla pagina of
Manuali d’uso simili
-
Network Card
ADTRAN T200 H2TU-R
21 pagine 0.52 mb -
Network Card
ADTRAN T200 H4TU-R
26 pagine 0.29 mb -
Network Card
ADTRAN DSLAM Octal SHDSL
2 pagine 0.78 mb -
Network Card
ADTRAN Cable T1 ESF CSU ACE
66 pagine 0.94 mb -
Network Card
ADTRAN E220 HFAC HDSL2
20 pagine 0.11 mb -
Network Card
ADTRAN NetVanta ADSL NIM
2 pagine 0.16 mb -
Network Card
ADTRAN 61200051L1
165 pagine 0.8 mb -
Network Card
ADTRAN 1184518L1
2 pagine 0.2 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso ADTRAN T200 H2TU-R. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica ADTRAN T200 H2TU-R o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso ADTRAN T200 H2TU-R descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso ADTRAN T200 H2TU-R dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo ADTRAN T200 H2TU-R
- nome del fabbricante e anno di fabbricazione ADTRAN T200 H2TU-R
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature ADTRAN T200 H2TU-R
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio ADTRAN T200 H2TU-R non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti ADTRAN T200 H2TU-R e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio ADTRAN in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche ADTRAN T200 H2TU-R, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo ADTRAN T200 H2TU-R, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso ADTRAN T200 H2TU-R. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
61150090L1-5A Section 61150090L1-5A, Issue 1 1 Section 61150090L1-5 Issue 1, April 1999 List 1: CLEI CODE # T1MJ4U0MRA List 2: CLEI CODE # T1MJ5U0MRA List 3: CLEI CODE # T1MJ4V0MRA List 4: CLEI CODE # T1MJ5V0MRA High Capacity T200/T400 Cabinet Installation and Maintenance Figure 1. High-Capacity T200/T400 Cabinet (Pad Mount Model) 1. GENERAL This p[...]
-
Pagina 2
2 Section 61150090L1-5A, Issue 1 61150090L1-5A • Moisture absorbing desiccant. • Spare cable hole entrance with removable seal. • Mounting template for craft planning. Cabinet Access The front and rear cabinet doors and support bracket access panels include tamper resistant security fasteners. The cabinet doors allow for a customer supplied l[...]
-
Pagina 3
61150090L1-5A Section 61150090L1-5A, Issue 1 3 Figure 2. Cabinet Assembly, Rear View Fan Operation and Indication Two thermostatically controlled line powered cooling fans limit heat buildup. The primary fan energizes at about 110 ° F. The secondary fan energizes at about 150 ° F. Primary and secondary fan board operation is monitored by the FPU.[...]
-
Pagina 4
4 Section 61150090L1-5A, Issue 1 61150090L1-5A 2. INSTALLATION The cabinet assembly weighs about 200 pounds. This Practice assumes that proper lifting devices are on hand for maneuvering and holding the cabinet in position until securely mounted. After unpacking the T200/T400 High Capacity Cabinet inspect it for damage. If damage is noted file a cl[...]
-
Pagina 5
61150090L1-5A Section 61150090L1-5A, Issue 1 5 the bracket pattern. Refer to Figure 4 for pad mount access dimensions. 1. At the installation site remove all packaging material enclosing the cabinet. 2. Remove and set aside the mounting hardware kit. Verify contents per Table 2 . 3. The cabinet is bolted to two boards running across the box frame. [...]
-
Pagina 6
6 Section 61150090L1-5A, Issue 1 61150090L1-5A 9. Hoist the cabinet to an upright position and center it over the pad. CAUTION The minimum internal bend radius for cable stubs is nine inches. 10. At this time, on the cable stub model, the cable stubs should be fed through their designated conduit or other route per craft plan. 11. Lower the cabinet[...]
-
Pagina 7
61150090L1-5A Section 61150090L1-5A, Issue 1 7 4. Attach lifting details. Screwed into each side of the cabinet is a group of three bolts and washers. Remove these for reuse. NOTE Observe that one of the lifting details is also the mounting bracket. Ensure the mounting bracket is attached to the side of the cabinet designated to be against the pole[...]
-
Pagina 8
8 Section 61150090L1-5A, Issue 1 61150090L1-5A 16. If the unused lifting detail is to be removed, replace the fasteners removed in step 4 ensuring the sealing washer is installed next to the cabinet. NOTE All unused threaded openings in the cabinet must have their designated fasteners inserted and tightened to ensure a proper seal. H-Frame Mount Fo[...]
-
Pagina 9
61150090L1-5A Section 61150090L1-5A, Issue 1 9 diameter range from 0.86 to 1.26 inches. Use care to ensure correct sequence of assembly. b. Insert the O-ring evenly in the groove provided on the sealing grommet. c. Insert the sealing grommet up through the designated cable opening until the O-ring is flush with the bottom of the cabinet. d. Screw t[...]
-
Pagina 10
1 0 Section 61150090L1-5A, Issue 1 61150090L1-5A NOTE Refer to Splice Module installation instructions for the length required inside the cabinet. Ensure sufficient sheathed cable exists at the top of the sealing grommet to install shield connectors. i. Using a wrench to hold the sealing grommet steady, use a second wrench to tighten the compressio[...]
-
Pagina 11
61150090L1-5A Section 61150090L1-5A, Issue 1 11 III. SHRINK-WRAP After all other connections are completed, or correct wire lengths verified, complete the shrink-wrap process as follows: a. Position the shrink-wrap up against the bottom of the cabinet enclosing the entire sealing grommet assembly. b. Heat treat the shrink-wrap until properly constr[...]
-
Pagina 12
1 2 Section 61150090L1-5A, Issue 1 61150090L1-5A Splice Module #1 Blue Binder Group Surge Arrestor Header Connection Used on Cable A only Ckt Bd Slot Connections Surge Arrestor Header Connection Orange Binder Group Splice Module #2 Used on Cable A only Table 5A. Splice Module 1 Table 5B. Splice Module 2 p i Tg n i R X X e t i h W e u l B 5 . 1 P 6 [...]
-
Pagina 13
61150090L1-5A Section 61150090L1-5A, Issue 1 13 Table 6A. Circuit Technology Configuration Chart (Part 1) t k C # k c a P# k c a P # k c a P # k c a P# k c a P # n i P &# n i P & # n i P & # n i P &# n i P & d a e Le l b a C r e d n i Br e d n i B r e d n i B r e d n i Br e d n i B r o l o Cr o l o C r o l o C r o l o Cr o l o C[...]
-
Pagina 14
1 4 Section 61150090L1-5A, Issue 1 61150090L1-5A Table 6B. Circuit Technology Configuration Chart (Part 2) # k c a P # n i P d n a# n i P d n a # n i P d n a # n i P d n a# n i P d n a d a e Le l b a C r e d n i Br e d n i B r e d n i B r e d n i Br e d n i B r o l o Cr o l o C r o l o C r o l o Cr o l o C r i a P # # # # # p i T e r i We r i W e r[...]
-
Pagina 15
61150090L1-5A Section 61150090L1-5A, Issue 1 15 Figure 13. Primary & Secondary Fan Boards 3. TESTING General Each test identifies a particular malfunction. For that reason associated components used to isolate a malfunction are assumed to be functioning correctly. Certain troubleshooting requires personnel at both the Central Office to monitor [...]
-
Pagina 16
1 6 Section 61150090L1-5A, Issue 1 61150090L1-5A 3. Disable the front door switch by centering the rod and pulling outward. The secondary fan board Door LED should go Off and the Door Alarm LED at the FPU will turn green. Fan Operation When the cabinet is initially installed without heat generating circuit packs, the primary and secondary fans will[...]
-
Pagina 17
61150090L1-5A Section 61150090L1-5A, Issue 1 17 If the cabinet has been opened during the day allowing the heat to escape before proper troubleshooting tests could be conducted, close the cabinet doors and allow the cabinet internal temperature to restabilize. Recheck during the hottest time of the following day before the outside temperature has a[...]
-
Pagina 18
1 8 Section 61150090L1-5A, Issue 1 61150090L1-5A Figure 15. Surge Arrestor Gas Tube Replacement 6. Disconnect the door switch JP2 connector on the fan board by carefully pulling the connector off the header. DO NOT PULL ON WIRES. 7. Take an insulated ball-clip or alligator-clip and short across the two exposed door switch JP2 connector pins at the [...]
-
Pagina 19
61150090L1-5A Section 61150090L1-5A, Issue 1 19 4. Replace the remaining gas tubes in the same manner. Each slot has four gas tubes. 5. Untag and reinsert the associated slot power module at the CO. 6. Perform circuit tests to verify proper circuit operation. NOTE If lightning is the suspected cause of circuit pack failure, ADTRAN recommends replac[...]
-
Pagina 20
2 0 Section 61150090L1-5A, Issue 1 61150090L1-5A Door Switch Replacement The door switch can be replaced in the field if it is damaged or becomes defective. WARNING High Voltages are present on exposed pins. Do not contact exposed surfaces. The following procedure applies to either the front or rear door switch ( Figure 16 ): 1. On the affected swi[...]
-
Pagina 21
61150090L1-5A Section 61150090L1-5A, Issue 1 21 f l e h S p o T # t o l S# t o l S # t o l S # t o l S# t o l S e m a N r e m o t s u C. D . I t i u c r i Ce t u o R m e t s y S# m e t s y Se p y T t i u c r i C 1 2 3 4 5 6 7 8 9 0 1 1 1 2 1 f l e h S m o t t o B # t o l S# t o l S # t o l S # t o l S# t o l S e m a N r e m o t s u C. D . I t i u c[...]