Warning: mysql_fetch_array() expects parameter 1 to be resource, boolean given in /home/newdedyk/domains/bkmanuals.com/public_html/includes/pages/manual_inc.php on line 26
Agilent Technologies 6611C manuale d’uso - BKManuals

Agilent Technologies 6611C manuale d’uso

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103

Vai alla pagina of

Un buon manuale d’uso

Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Agilent Technologies 6611C. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Agilent Technologies 6611C o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Agilent Technologies 6611C descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso Agilent Technologies 6611C dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Agilent Technologies 6611C
- nome del fabbricante e anno di fabbricazione Agilent Technologies 6611C
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Agilent Technologies 6611C
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Agilent Technologies 6611C non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Agilent Technologies 6611C e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Agilent Technologies in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Agilent Technologies 6611C, come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Agilent Technologies 6611C, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Agilent Technologies 6611C. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    Programming Guide Dynamic Measurement DC Source Agilent Models 66312A, 66332A System DC Power Supply Agilent Models 6631B, 6632B, 6633B, 6634B 6611C, 6612C, 6613C, 6614C Agilent Part No. 5962-8198 Printed in U.S.A. Microfiche No 5962-8199 January, 2000[...]

  • Pagina 2

    2 Safety Guidelines The beginning of the Operating Guide has a Safety Summary page. Be sure you are familiar with the information on this page before programming the dc source for operation from a controller. Printing History The edition and current revision of this manual are indicated below. Reprints of this guide containing minor corrections and[...]

  • Pagina 3

    3 Table of Contents Safety Guidelines 2 Printing History 2 Table of Contents 3 1 - GENERAL INFORMATION 7 About this Guide 7 Documentation Summary 7 External References 8 GPIB References 8 SCPI References 8 2 - INTRODUCTION TO PROGRAMMING 9 VXI plug&play Power Products Instrument Drivers 9 Supported Applications 9 System Requirements 9 Downloadi[...]

  • Pagina 4

    4 Output Trigger System Model 21 Setting the Voltage or Current Trigger Levels 21 Initiating the Output Trigger System 22 Generating Triggers 22 Making Measurements 23 Voltage and Current Measurements 23 Internally Triggered Measurements 25 SCPI Triggering Nomenclature 25 Measurement Trigger System Model 25 Initiating the Measurement Trigger System[...]

  • Pagina 5

    5 MEASure:CURRent? FETCh:CURRent? 48 MEASure:CURRent:ACDC? FETCh:CURRent:ACDC? 48 MEASure:CURRent:HIGH? FETCh:CURRent:HIGH? 48 MEASure:CURRent:LOW? FETCh:CURRent:LOW? 49 MEASure:CURRent:MAXimum? FETCh:CURRent: MAXimum? 49 MEASure:CURRent:MINimum? FETCh:CURRent:MINimum? 49 MEASure:VOLTage? FETCh:VOLTage? 50 MEASure:VOLTage:ACDC? FETCh:VOLTage:ACDC? [...]

  • Pagina 6

    6 System Commands 68 DISPlay 68 DISPlay:MODE 68 DISPlay:TEXT 68 SYSTem:ERRor? 69 SYSTem:LANGuage 69 SYSTem:VERSion? 69 SYSTem:LOCal 70 SYSTem:REMote 70 SYSTem:RWLock 70 *IDN? 70 *OPT? 71 *RCL 71 *RST 71 *SAV 72 *TST? 72 Trigger Commands 73 ABORt 73 INITiate:SEQuence INITiate:NAME 73 INITiate:CONTinuous:SEQuence1 INITiate:CONTinuous:NAME 73 TRIGger [...]

  • Pagina 7

    7 1 General Information About this Guide This guide provides remote programming information for the following series of GPIB programmable dc power supplies: • Agilent 66312A • Agilent 66332A • Agilent 6631B/6632B/6633B/6634B • Agilent 6611C/6612C/6613C/6614C You will find the following information in the rest of this guide: Chapter 1 Introd[...]

  • Pagina 8

    1 - General Information 8 External References GPIB References The most important GPIB documents are your controller programming manuals - BASIC, GPIB Command Library for MS DOS, etc. Refer to these for all non-SCPI commands (for example: Local Lockout). The following are two formal documents concerning the GPIB interface: ♦ ANSI/IEEE Std. 488.1-1[...]

  • Pagina 9

    9 2 Introduction to Programming VXI plug&play Power Products Instrument Drivers VXI plug&play instrument drivers for Microsoft Windows 95 and Windows NT are now available on the Web at http://www.agilent.com/find/drivers. These instrument drivers provide a high-level programming interface to your Agilent Technologies instrument. VXI plug&am[...]

  • Pagina 10

    2 - Introduction to Programming 10 6 . To use the VXI plug&play instrument driver, follow the directions in the VXI plug&play online help under “Introduction to Programming”. Accessing Online Help A comprehensive online programming reference is provided with the driver. It describes how to get started using the instrument driver with Ag[...]

  • Pagina 11

    Introduction to Programming - 2 11 Baud Rate The front panel Address key lets you select one of the following baud rates, which is stored in non-volatile memory: 300 600 1200 2400 4800 9600 RS-232 Flow Control The RS-232 interface supports several flow control options that are selected using the front panel Address key. For each case, the dc source[...]

  • Pagina 12

    2 - Introduction to Programming 12 FUNCTION gets$ ‘ Get a new line feed terminated string from device #1 C$ = “” ‘ Set C$ to null WHILE c$ <> CHR$ (10) ‘ Set loop to stop at Line Feed C$ = INPUT$ (1, #1) ‘ Read 1 bit into file #1 Resp$ = resp$ + c$ ‘ Concantenate bit with previous bits WEND ‘ End of WHILE loop gets$ = resp$ ?[...]

  • Pagina 13

    Introduction to Programming - 2 13 Types of SCPI Commands SCPI has two types of commands, common and subsystem. ♦ Common commands generally are not related to specfic operation but to controlling overall dc source functions, such as reset, status, and synchronization. All common commands consist of a three-letter nmemonic preceded by an asterisk:[...]

  • Pagina 14

    2 - Introduction to Programming 14 Moving Among Subsystems In order to combine commands from different subsystems, you need to be able to reset the header path to a null string within a message. You do this by beginning the command with a colon (:), which discards any previous header path. For example, you could clear the output protection and chec[...]

  • Pagina 15

    Introduction to Programming - 2 15 Data Ke y words Ke y word Separator Messa g e Unit Separators Messa g e Unit Query Indic ator Messa g e Terminator Root Specifier VOLT <NL > :L E V 2 0 PROT 21 ; ; : CURR? Figure 2-2. Command Message Structure The Message Unit The simplest SCPI command is a single message unit consisting of a command header [...]

  • Pagina 16

    2 - Introduction to Programming 16 NOTE: All RS-232 response data sent by the dc source is terminated by the ASCII character pair <carriage return><newline>. This differs from GPIB response data which is terminated by the single character <newline> with EOI asserted. SCPI Data Formats All data programmed to or returned from the dc[...]

  • Pagina 17

    Introduction to Programming - 2 17 SCPI Command Completion SCPI commands sent to the dc source are processed either sequentially or in parallel. Sequential commands finish execution before a subsequent command begins. Parallel commands allow other commands to begin executing while the parallel command is still executing. Commands that affect trigge[...]

  • Pagina 18

    [...]

  • Pagina 19

    19 3 Programming the DC Source Introduction This chapter contains examples on how to program your dc source. Simple examples show you how to program: u output functions such as voltage and current u internal and external triggers u measurement functions u the status and protection functions NOTE: These examples in this chapter show which commands a[...]

  • Pagina 20

    3 - Programming the DC Source 20 Output Voltage The output voltage is controlled with the VOLTage command. For example, to set the output voltage to 25 volts, use: VOLTage 125 The dc source can be programmed to turn off its output if the output voltage exceeds a preset peak voltage limit. This protection feature is implemented with the VOLTage:PROT[...]

  • Pagina 21

    Programming the DC Source - 3 21 Triggering Output Changes The dc source has two independent trigger systems. One is used for generating output changes, and the other is used for triggering measurements. This section describes the output trigger system. The measurement trigger system is described under "Triggering Measurements". SCPI Trig[...]

  • Pagina 22

    3 - Programming the DC Source 22 Initiating the Output Trigger System When the dc source is turned on, the trigger subsystem is in the idle state. In this state, the trigger subsystem ignores all triggers. Sending the following commands at any time returns the trigger system to the Idle state: ABORt *RST *RCL The INITiate commands move the trigger [...]

  • Pagina 23

    Programming the DC Source - 3 23 Making Measurements The dc source has the ability to make several types of voltage or current measurements. The measurement capabilities of the Agilent 66312A and Agilent 66332A models are particulary useful for loads that draw current in pulses. NOTE: You cannot measure output voltage and current simultaneously. Al[...]

  • Pagina 24

    3 - Programming the DC Source 24 This results in a data acquisition time of 32 milliseconds. Adding a command processing overhead of about 20 milliseconds results in a total measurement time of about 50 milliseconds per measurement sample. Ripple rejection is a function of the number of cycles of the ripple frequency contained in the acquisition wi[...]

  • Pagina 25

    Programming the DC Source - 3 25 Internally Triggered Measurements You can use the data acquisition trigger system to synchronize the timing of the voltage and current data acquisition with a BUS or internal trigger source. Then use the FETCh commands to return different calculations from the data acquired by the measurement trigger. SCPI Triggerin[...]

  • Pagina 26

    3 - Programming the DC Source 26 INITiate:SEQuence2 or INITiate:NAME ACQuire After a trigger is received and the data acquisition completes, the trigger system will return to the Idle state (unless multiple measurements are desired). Thus it will be necessary to initiate the system each time a triggered acquisition is desired. NOTE: You cannot init[...]

  • Pagina 27

    Programming the DC Source - 3 27 TRI G: ACQ: SL OP: CURR TR IG:AC Q : LEV:CURR <le ve l > TRI G: ACQ: HYST : CUR R <v a l u e > Tr i gg er occurs on ri sin g ed g e whe n s i g nal crosses posit ive h y ster es is b and l imit TR IG:AC Q:H YST :VO LT TRI G: ACQ: SL OP: CURR NEG TR IG:AC Q:S LOP :VO LT TR IG:AC Q:S LOP : V O LT TRI G: AC[...]

  • Pagina 28

    3 - Programming the DC Source 28 Measuring Output Pulses (Agilent 66312A, 66332A Only) Current Detector Check that the current detector is set to ACDC when measuring current pulses or other waveforms with a frequency content greater than a few kilohertz. SENSe:CURRent:DETect ACDC Only select DC as the measurement detector if you are making only DC [...]

  • Pagina 29

    Programming the DC Source - 3 29 Controlling Measurement Samples Varying the Voltage or Current Sampling Rate You can vary both the number of data points in a measurement sample, as well as the time between samples. This is illustrated in Figure 3-5. SENS:SWE:POI N < #o f p oints > SENS:SWE:TI NT <t i me> TRI G: ACQ: COUN: CURR < #o [...]

  • Pagina 30

    3 - Programming the DC Source 30 Pre-event and Post-event Triggering (Agilent 66312A, 66332A Only) When a measurement is initiated, the dc source continuously samples either the instantaneous output voltage or current. As shown in figure 3-6, you can move the block of data being read into the acquisition buffer with reference to the acquisition tri[...]

  • Pagina 31

    Programming the DC Source - 3 31 10 !Rev A.00.00 20 OPTION BASE 1 30 DIM Curr_array(100) 40 ! 50 ASSIGN @Ps TO 705 60 ASSIGN @Ld TO 706 80 OUTPUT @Ps;"*RST" ! Sets supply to default values 90 OUTPUT @Ps;"OUTP ON" ! Turn on power supply output 100 OUTPUT @Ps;"VOLT 5;CURR 5" ! Program power supply to 5 volts, 5 amps 110 [...]

  • Pagina 32

    3 - Programming the DC Source 32 Programming the Status Registers You can use status register programming to determine the operating condition of the dc source at any time. For example, you may program the dc source to generate an interrupt (assert SRQ) when an event such as a current limit occurs. When the interrupt occurs, your program can then a[...]

  • Pagina 33

    Programming the DC Source - 3 33 Table 3-1. Bit Configurations of Status Registers Bit Signal Meaning 0 5 8 10 11 CAL WTG CV CC+ CC- Operation Status Group The dc source is computing new calibration constants The dc source is waiting for a trigger The dc source is in constant voltage mode The dc source is in constant current mode The dc source is i[...]

  • Pagina 34

    3 - Programming the DC Source 34 Questionable Status Group The Questionable Status registers record signals that indicate abnormal operation of the dc source. As shown in figure 3-7, the group consists of the same type of registers as the Status Operation group. The outputs of the Questionable Status group are logically-ORed into the QUEStionable s[...]

  • Pagina 35

    Programming the DC Source - 3 35 The MSS Bit This is a real-time (unlatched) summary of all Status Byte register bits that are enabled by the Service Request Enable register. MSS is set whenever the dc source has one or more reasons for requesting service. *STB? reads the MSS in bit position 6 of the response but does not clear any of the bits in t[...]

  • Pagina 36

    3 - Programming the DC Source 36 event to be summed into the Questionable summary bit. Use: STATus:QUEStionable:PTR 19;ENABle 19 (1 + 2 + 16 = 19) Step 3 Program the Service Request Enable register to allow both the Operation and the Questionable summary bits from the Status Byte register to generate RQS. Use: *SRE 136 (8 + 128 = 136) Step 4 When y[...]

  • Pagina 37

    Programming the DC Source - 3 37 Using the Inhibit/Fault Port as a Digital I/O You can configure the inhibit/fault port to provide a digital input/output to be used with custom digital interface circuits or relay circuits. As shipped from the factory, the port is shipped for inhibit/fault operation. You can change the configuration of the port to o[...]

  • Pagina 38

    [...]

  • Pagina 39

    39 4 Language Dictionary Introduction This section gives the syntax and parameters for all the IEEE 488.2 SCPI commands and the Common commands used by the dc source. It is assumed that you are familiar with the material in “Chapter 2 - "Remote Programming". That chapter explains the terms, symbols, and syntactical structures used here [...]

  • Pagina 40

    4 - Language Dictionary 40 Table 4-1. Subsystem Commands Syntax ABORt Resets the trigger system to the Idle state CALibrate : :CURRent [:SOURce] [:DC] [:POSitive] :NEGative Calibrate positive output current and high current measurement range Calibrate negative output current :MEASure [:DC] :LOWRange Calibrate low current measurement range :AC Calib[...]

  • Pagina 41

    Language Dictionary - 4 41 Table 4-1. Subsystem Commands Syntax (continued) OUTPut [:STATe] <bool> [,NORelay] Enables/disables the dc source output :DFI [:STATe] <bool> Enable/disable DFI output :SOURce <source> Selects event source (QUES | OPER | ESB | RQS | OFF) :PON :STATe <state> Set power-on state (*RST | RCL0) :PROTect[...]

  • Pagina 42

    4 - Language Dictionary 42 Table 4-1. Subsystem Commands Syntax (continued) STATus :PRESet Presets all enable and transition registers to power-on :OPERation [:EVENt]? Returns the value of the event register :CONDition? Returns the value of the condition register :ENABle <n> Enables specific bits in the Event register :NTRansition<n> Se[...]

  • Pagina 43

    Language Dictionary - 4 43 Common Commands Common commands begin with an * and consist of three letters (command) or three letters and a ? (query). They are defined by the IEEE 488.2 standard to perform common interface functions. Common commands and queries are categorized under System, Status, or Trigger functions and are listed at the end of eac[...]

  • Pagina 44

    4 - Language Dictionary 44 Calibration Commands Calibration commands let you: u Enable and disable the calibration mode u Change the calibration password u Calibrate the current and voltage programming and measurement, and store new calibration constants in nonvolatile memory. NOTE: If calibration mode has not been enabled with CALibrate:STATe, pro[...]

  • Pagina 45

    Language Dictionary - 4 45 CALibrate:DATA This command enters a calibration value that you obtain by reading an external meter. You must first select a calibration level (with CALibrate:LEVel) for the value being entered. Command Syntax CALibrate:DATA<NRf> Parameters <external reading> Unit A (amperes) Examples CAL:DATA 3222.3 MA CAL:DA[...]

  • Pagina 46

    4 - Language Dictionary 46 CALibrate:STATe This command enables and disables calibration mode. The calibration mode must be enabled before the will accept any other calibration commands. The first parameter specifies the enabled or disabled state. The second parameter is the password. It is required if the calibration mode is being enabled and the [...]

  • Pagina 47

    Language Dictionary - 4 47 Measurement Commands Measurement commands consist of measure and sense commands. Measure commands measure the output voltage or current. Measurements are performed by digitizing the instantaneous output voltage or current for a defined number of samples and sample interval, storing the results in a buffer, and calculating[...]

  • Pagina 48

    4 - Language Dictionary 48 MEASure:CURRent? FETCh:CURRent? FETCh:CURRent? applies to Agilent 66312A, 66332A Only These queries return the dc output current. Query Syntax MEASure:[SCALar]:CURRent[:DC]? FETCh:[SCALar]:CURRent[:DC]? Parameters None Examples MEAS:CURR? MEAS:CURR:DC? Returned Parameters <NR3> Related Commands MEAS:VOLT? MEASure:CU[...]

  • Pagina 49

    Language Dictionary - 4 49 MEASure:CURRent:LOW? FETCh:CURRent:LOW? Agilent 66312A, 66332A Only These queries return the Low level current of a current pulse waveform. The instrument first measures the minimum and maximum data points of the pulse waveform. It then generates a histogram of the pulse waveform using 1024 bins between the maximum and mi[...]

  • Pagina 50

    4 - Language Dictionary 50 MEASure:VOLTage? FETCh:VOLTage? FETCh:VOLTage? applies to Agilent 66312A, 66332A Only These queries return the dc output voltage. Query Syntax MEASure[:SCALar]:VOLTage[:DC]? MEASure[:SCALar]:VOLTage[:DC]? Parameters None Examples MEAS:VOLT? FETC:VOLT:DC? Returned Parameters <NR3> Related Commands MEAS:CURR? MEASure:[...]

  • Pagina 51

    Language Dictionary - 4 51 MEASure:VOLTage:LOW? FETCh:VOLTage:LOW? Agilent 66312A, 66332A Only These queries return the Low level voltage of a voltage pulse waveform. The instrument first measures the minimum and maximum data points of the pulse waveform. It then generates a histogram of the pulse waveform using 1024 bins between the maximum and mi[...]

  • Pagina 52

    4 - Language Dictionary 52 SENSe:CURRent:RANGe This command selects the dc current measurement range. All models have two current measurement ranges: High Range: 0 through MAX (see Table 4-3) Low Range: 0 through 0.02 A (all models) The High range covers the full current measurement capability of the instrument. The Low range measures currents up t[...]

  • Pagina 53

    Language Dictionary - 4 53 SENSe:FUNCtion Agilent 66312A, 66332A Only This command configures the measurement sensor to measure either voltage or current when an acquire trigger is used. The query returns the function setting, either VOLT or CURR. Command Syntax SENSe:FUNCtion <function Parameters "VOLTage" | "CURRent" Exampl[...]

  • Pagina 54

    4 - Language Dictionary 54 SENSe:WINDow This command sets the window function that is used in output measurement calculations. The following functions can be selected: HANNing A signal conditioning window that reduces errors in dc and rms measurement calculations in the presence of periodic signals such as line ripple. It also reduces jitter when m[...]

  • Pagina 55

    Language Dictionary - 4 55 Output Commands Output commands consist of output and source commands. Output commands control the output and digital port functions. They also control the output relay on units with Relay Option 760. Source commands program the actual voltage, current, and digital port output. OUTPut This command enables or disables the [...]

  • Pagina 56

    4 - Language Dictionary 56 OUTPut:PON:STATe This command selects the power-on state of the dc source. This information is saved in non-volatile memory. The following states can be selected: RST Sets the power-on state to *RST. Refer to the *RST command as described in this chapter for more information. RCL0 Sets the power-on state to *RCL 0. Refer [...]

  • Pagina 57

    Language Dictionary - 4 57 OUTPut:RELay Agilent 66332A, 6632B, 6633B, 6634B, 6611C, 6612C, 6613C, 6614C Only This command is only valid for units with Relay Option 760, otherwise an error will occur. Programming ON closes the output relay contacts; programming OFF opens them. The relay is controlled independently of the output state. If the dc sour[...]

  • Pagina 58

    4 - Language Dictionary 58 [SOURce:]CURRent This command sets the immediate current level of the dc source . The immediate level is the current programmed for the output terminals. Command Syntax [SOURce]:CURRent[:LEVel][:IMMediate][:AMPLitude]<NRf+> Parameters see Table 4-3 Default Suffix A (amperes) *RST Value 10% of MAX Examples CURR 200 M[...]

  • Pagina 59

    Language Dictionary - 4 59 [SOURce:]DIGital:DATA This command sets and reads the dc source digital control port when that port is configured for Digital I/O operation. The port has three signal pins and a digital ground pin. Pins 1 and 2 are output pins controlled by bits 0 and 1. Pin 3 is controlled by bit 2, and can be programmed to serve either [...]

  • Pagina 60

    4 - Language Dictionary 60 [SOURce:]VOLTage:ALC:BANDwidth? [SOURce:]VOLTage:ALC:BWIDth? Agilent 66332A, 6631B, 6632B, 6633B and 6634B Only These queries return the setting of the output mode switch. The output mode switch is used to connect or disconnect the the output capacitor located inside the unit. The returned value is 15,000 if the switch is[...]

  • Pagina 61

    Language Dictionary - 4 61 Status Commands Status commands program the dc source status registers. The dc source has three groups of status registers; Operation, Questionable, and Standard Event. The Standard Event group is programmed with Common commands as described later in this section. The Operation and Questionable status groups each consist [...]

  • Pagina 62

    4 - Language Dictionary 62 STATus:OPERation:ENABle This command and its query set and read the value of the Operational Enable register. This register is a mask for enabling specific bits from the Operation Event register to set the operation summary bit (OPER) of the Status Byte register. This bit (bit 7) is the logical OR of all the Operatonal Ev[...]

  • Pagina 63

    Language Dictionary - 4 63 Table 4-5. Bit Configuration of Questionable Status Registers Bit Position 15 14 13-11 10 9 8-5 4 3 2 1 0 Bit Name not used Meas Ovld not used Unreg RI not used OT not used FS OCP OV Bit Weight 16384 1024 512 16 4 2 1 OV = overvoltage protection has tripped OCP = overcurrent protection has tripped FS = the fuse is blown O[...]

  • Pagina 64

    4 - Language Dictionary 64 STATus:QUEStionable:NTR STATus:QUEStionable:PTR These commands allow you to set or read the value of the Questionable NTR (Negative-Transition) and PTR (Positive-Transistion) registers. These registers serve as polarity filters between the Questionable Enable and Questionable Event registers to cause the following actions[...]

  • Pagina 65

    Language Dictionary - 4 65 *ESE This command programs the Standard Event Status Enable register bits. The programming determines which events of the Standard Event Status Event register (see *ESR?) are allowed to set the ESB (Event Summary Bit) of the Status Byte register. A "1" in the bit position enables the corresponding event. All of [...]

  • Pagina 66

    4 - Language Dictionary 66 * OPC does not prevent processing of subsequent commands, but bit 0 will not be set until all pending operations are completed. *OPC? causes the instrument to place an ASCII "1" in the Output Queue when all pending operations are completed. Unlike *OPC, *OPC? prevents processing of all subsequent commands. It is[...]

  • Pagina 67

    Language Dictionary - 4 67 Command Syntax *SRE <NRf> Parameters 0 to 255 Power-on Value see *PSC Example *SRE 20 Query Syntax *SRE? Returned Parameters <NR1> (register binary value) Related Commands *ESE *ESR *PSC CAUTION: If *PSC is programmed to 0, the *SRE command causes a write cycle to nonvolatile memory. Nonvolatile memory has a f[...]

  • Pagina 68

    4 - Language Dictionary 68 System Commands System commands consist of system, display, and common commands. System commands commands control system functions that are not directly related to output control or measurement functions. Display commands control the front panel display of the . Common commands also perform system functions. The following[...]

  • Pagina 69

    Language Dictionary - 4 69 SYSTem:ERRor? This query returns the next error number followed by its corresponding error message string from the remote programming error queue. The queue is a FIFO (first-in, first-out) buffer that stores errors as they occur. As it is read, each error is removed from the queue. When all errors have been read, the quer[...]

  • Pagina 70

    4 - Language Dictionary 70 SYSTem:LOCal For RS-232 Operation Only This command places the dc source in local mode during RS-232 operation. The front panel keys are functional. Command Syntax SYSTem:LOCal Parameters None Example SYST:LOC Related Commands SYST:REM SYST:RWL SYSTem:REMote For RS-232 Operation Only This command places the dc source in r[...]

  • Pagina 71

    Language Dictionary - 4 71 *OPT? This query requests the dc source to identify any options that are installed. Options are identified by number A 0 indicates no options are installed. Query Syntax *OPT? Returned Parameters <AARD> *RCL WARNING: Recalling a previously stored state may place hazardous voltages at the dc source output. This comma[...]

  • Pagina 72

    4 - Language Dictionary 72 Table 4-8. *RST Settings CAL:STAT OFF [SOUR:]CURR 10% of MAX* DIG:DATA 0 [SOUR:]CURR:TRIG 10% of MAX* DISP:STAT ON [SOUR:]CURR:PROT:STAT OFF DISP:MODE NORM [SOUR:]LIST:COUN 0 DISP:TEXT ‘ ‘ [SOUR:]VOLT 0 INIT:CONT OFF [SOUR:]VOLT:TRIG 0 OUTP OFF [SOUR:]VOLT:PROT MAX* OUTP:DFI OFF TRIG:ACQ:COUN:CURR 1 OUTP:DFI:SOUR OFF [...]

  • Pagina 73

    Language Dictionary - 4 73 Trigger Commands Trigger commands consist of trigger and initiate commands. Trigger commands control the remote triggering of the dc source . Trigger commands (and Initate commands) are referenced either by name or by number. The correspondence between names and numbers is: Sequence Number Sequence Name Description 1 (the[...]

  • Pagina 74

    4 - Language Dictionary 74 TRIGger When the transient trigger subsystem is initiated, this command generates a trigger signal. The trigger will then: 1. Initiate a pending level change as specified by CURRent:TRIGger or VOLTage;TRIGger. 2. Clear the WTG bit in the Status Operation Condition register after both transient and acquire trigger sequence[...]

  • Pagina 75

    Language Dictionary - 4 75 TRIGger:SEQuence2:COUNt:CURRent TRIGger:ACQuire:COUNt:CURRent Agilent 66312A, 66332A Only This command sets up a successive number of triggers for measuring current data. With this command, the trigger system needs to be initialized only once at the start of the acquisition period. After each completed measurement, the in[...]

  • Pagina 76

    4 - Language Dictionary 76 TRIGger:SEQuence2:HYSTeresis:CURRent TRIGger:ACQuire:HYSTeresis:CURRent Agilent 66312A, 66332A Only This command defines a band around the trigger level through which the signal must pass before an internal measurement can occur. The band limit above and below the trigger level is one half of the hysteresis value added to[...]

  • Pagina 77

    Language Dictionary - 4 77 TRIGger:SEQuence2:LEVel:CURRent TRIGger:ACQuire:LEVel:CURRent Agilent 66312A, 66332A Only This command sets the trigger level for internally triggered current measurements. A positive current trigger occurs when the current level changes from a value less than the lower hysteresis band limit to a value greater than the up[...]

  • Pagina 78

    4 - Language Dictionary 78 TRIGger:SEQuence2:SLOPe:CURRent TRIGger:ACQuire:SLOPe:CURRent Agilent 66312A, 66332A Only This command sets the slope of an internally triggered current measurement. POSitive triggering occurs on the rising edge. NEGative triggering occurs on the falling edge. EITHer triggering occurs on either edge. Command Syntax TRIGge[...]

  • Pagina 79

    Language Dictionary - 4 79 TRIGger:SEQuence2:SOURce TRIGger:ACQuire:SOURce Agilent 66312A, 66332A Only These commands select the trigger source for measurement triggers as follows: BUS GPIB device, *TRG, or <GET> (Group Execute Trigger) INTernal trigger is generated internally when the measured waveform crosses the trigger level with the sele[...]

  • Pagina 80

    [...]

  • Pagina 81

    81 A SCPI Conformance Information SCPI Version The Agilent Dynamic Measurement DC Source conforms to SCPI Version 1995.0. SCPI Confirmed Commands ABOR SENS:SWE:POIN CAL:DATA SENS:SWE:TINT CAL:STAT STAT:OPER[:EVEN]? DISP[:WIND][:STAT] STAT:OPER:COND? DISP[:WIND]:TEXT[:DATA] STAT:OPER:ENAB INIT[:IMM]:SEQ | NAME STAT:OPER:NTR INIT:CONT:SEQ | NAME STAT[...]

  • Pagina 82

    [...]

  • Pagina 83

    83 B Compatibility Language Introduction The Agilent power supplies covered by this manual are programmatically compatible with the HP/Agilent 6632A, 6633A, and 6634A dc power supplies. This means that by using COMPatibility language mode you can program these newer dc sources over the GPIB using COMPatibility commands. To switch from SCPI commands[...]

  • Pagina 84

    B - Compatibility Language 84 Table B-2. COMPatibility Commands Compatibility Command Description Similar SCPI Command ASTS? This command reads the contents of the accumulated status register, which stores any bit condition entered in the status register since the accumulated status register was last read, regardless of whether the condition still [...]

  • Pagina 85

    Compatibility Language - B 85 Table B-2. COMPatibility Commands (continued) Compatibility Command Description Similar SCPI Command OVSET <n> This command programs the overvoltage protection. See Table 4-3 for the programming range of this command. Initial condition: MAX VOLT:PROT POL 0 | 1 Only applies to units with Option 760. This command s[...]

  • Pagina 86

    B - Compatibility Language 86 Table B-2. COMPatibility Commands (continued) Compatibility Command Description Similar SCPI Command UNMASK xxx These commands determine the conditions that will set bits in the fault register, allowing the operator to define the conditions that will be reported as fault Fault conditions can be enabled by sending the d[...]

  • Pagina 87

    Compatibility Language - B 87 STAT US 1 2 16 64 128 CV +CC UNR OT not used OC ERR INH OV 4 512 -CC FAST 8 32 256 1024 2048 REGISTER NORM STAT US 1 2 16 64 128 4 512 8 32 256 1024 2048 REGISTER ACC UMU LA TED MASKUS 1 2 16 64 128 4 512 8 32 256 1024 2048 REGISTER CV +CC UNR OT not us ed OC ERR INH OV -CC FAST NORM FAUL T 1 2 16 64 128 4 512 8 32 256[...]

  • Pagina 88

    [...]

  • Pagina 89

    89 C Error Messages Error Number List This appendix gives the error numbers and descriptions that are returned by the dc source. Error numbers are returned in two ways: ♦ Error numbers are displayed on the front panel ♦ Error numbers and messages are read back with the SYSTem:ERRor? query. SYSTem:ERRor? returns the error number into a variable [...]

  • Pagina 90

    C - Error Messages 90 Table C-1. Error Numbers (continued) Error Number Error String [Description/Explanation/Examples] –141 Invalid character data [bad character, or unrecognized] –144 Character data too long –148 Character data not allowed –150 String data error –151 Invalid string data [e.g., END received before close quote] –158 Str[...]

  • Pagina 91

    Error Messages - C 91 Table C-1. Error Numbers (continued) Error Number Error String [Description/Explanation/Examples] 213 Ingrd receiver buffer overrun 216 RS-232 receiver framing error 217 RS-232 receiver parity error 218 RS-232 receiver overrun error 220 Front panel uart overrun 221 Front panel uart framing 222 Front panel uart parity 223 Front[...]

  • Pagina 92

    [...]

  • Pagina 93

    93 D Example Programs Introduction The example programs in this section are intended to show how some of the same dc source functions can be programmed to each of the following GPIB interfaces: 1. HP Vectra PC controller with Agilent 82335A GPIB Interface Command Library 2. IBM PC controller with National Instuments GPIB-PCII Interface/Handler 3. A[...]

  • Pagina 94

    D - Example Programs 94 Your application program will not include the dc source’s symbolic name and GPIB address. These must be specified during configuration (when you run IBCONF.EXE). Note that the primary address range is from 0 to 30 but any secondary address must be specified in the address range of 96 to 126. The dc source expects a message[...]

  • Pagina 95

    Example Programs - D 95 1085 ’ 1090 ’Query dc source outputs CURRENT?" :GOSUB 2000 :GOSUB 3000 1100 VOUT = OUTPUTS(1) 1105 IOUT = OUTPUTS(2) 1110 PRINT "The output levels are "VOUT" Volts and "IOUT" Amps" 1115 ’ 1120 ’Program triggered current level to value insufficient to maintain 1125 ’supply within i[...]

  • Pagina 96

    D - Example Programs 96 Example 2. IBM Controller Using National Interface 990 ’---------------------- Merge DECL.BAS here ------------------------ 1000 ’DC Source Variable = PS% ; Stand-Alone Address = 706 1005 CODES$=SPACE$(50):MODE$=SPACE$(5):OEVENT$=SPACE$(20) 1010 D$=SPACE$(60):OUTPUT$=SPACE$(40):BDNAME$="PS%" 1015 DIM OUTPUT(2) [...]

  • Pagina 97

    Example Programs - D 97 1225 ’ 1230 ’Clear status circuit 1235 CODES$="*CLS" :GOSUB 2000 1240 FOR I=1 TO 50 :NEXT I ’Wait for supply to clear 1245 ’ 1250 ’Disable output and save present state to location 2 1255 CODES$ = "OUTPUT OFF;*SAV 2" :GOSUB 2000 1260 END 1265 ’ 2000 ’Send command to dc source 2005 CALL IBWRT[...]

  • Pagina 98

    D - Example Programs 98 Example 3. Controller Using BASIC 1000 !Dc source at stand-alone address = 706 1005 OPTION BASE 1 1010 DIM Codes$[80],Response$[80],Mode$[32] 1015 ! 1020 !Program dc source to CV mode with following voltage and current 1025 OUTPUT 706;"VOLTAGE MAX;CURRENT MAX" 1030 ! 1035 !Query dc source outputs and print to scree[...]

  • Pagina 99

    99 INDEX —A— AARD, 16 ABORT, 73 ACDC, 52 —B— bus, 79 —C— calibration commands, 44 CAL CURR, 44 CAL CURR MEAS AC, 44 CAL CURR NEG, 44 CAL DATA, 45 CAL LEV, 45 CAL PASS, 45 CAL SAVE, 45 CAL STAT, 46 CAL VOLT, 46 CAL VOLT PROT, 46 calibration commands:CAL CURR MEAS LOWR ", 44 character strings, 16 combine commands common commands, 14 [...]

  • Pagina 100

    Index 100 —H— hanning, 54 header, 15 long form, 15 short form, 15 history, 2 HP 8235A driver, 93 HP BASIC controllers, 94 HP-IB address, 10 capabilities of the dc source, 10 triggers, 26 —I— INH, 36 initialization, 19 initiate commands, 73 INIT CONT NAME, 73 INIT CONT SEQ, 73 INIT NAME, 73 INIT SEQ, 73 initiating measurement trigger system,[...]

  • Pagina 101

    Index 101 —R— rectangular, 54 remote inhibit, 36 returning voltage or current data, 24 RI, 36 rms measurements, 24 root specifier, 15 RQS bit, 35 RS-232 capabilities of the dc source, 10 data format, 10, 12 data terminator, 16 flow control, 11 RTS-CTS, 11 —S— safety guidelines, 2 SCPI command completion, 17 command syntax, 39 command tree, [...]

  • Pagina 102

    Index 102 —V— varying voltage or current sampling, 29 voltage, 20 maximum, 20 measurements, 23 —W— waiting for measurement results, 27 —X— XON-XOFF, 11[...]

  • Pagina 103

    Manual Updates The following updates have been made to this manual since the December 1998 printing indicated on the Printing History page. 11/9/99 Information about installing VXI plug&play Power Products Instrument Drivers has been included in the beginning of chapter 2. 1/4/00 All references to HP have been changed to Agilent. All references[...]