Alliance Laundry Systems Drying Tumbler 70278501R5EN manuale d’uso
- Visualizza on-line o scarica il manuale
- 32 pagine
- 2 mb
Vai alla pagina of
Manuali d’uso simili
-
Washer
Alliance Laundry Systems 1336
111 pagine 1.34 mb -
Washer
Alliance Laundry Systems UF35PV
119 pagine 1.23 mb -
Washer
Alliance Laundry Systems PHM1397C
25 pagine 0.73 mb -
Washer
Alliance Laundry Systems UW35PV
43 pagine 1.58 mb -
Washer
Alliance Laundry Systems WF185
52 pagine 2.27 mb -
Washer
Alliance Laundry Systems SF25VNV
92 pagine 0.89 mb -
Washer
Alliance Laundry Systems FTU90A*N
18 pagine 0.28 mb -
Washer
Alliance Laundry Systems DRY683C
42 pagine 0.3 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Alliance Laundry Systems Drying Tumbler 70278501R5EN. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Alliance Laundry Systems Drying Tumbler 70278501R5EN o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Alliance Laundry Systems Drying Tumbler 70278501R5EN descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Alliance Laundry Systems Drying Tumbler 70278501R5EN dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Alliance Laundry Systems Drying Tumbler 70278501R5EN
- nome del fabbricante e anno di fabbricazione Alliance Laundry Systems Drying Tumbler 70278501R5EN
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Alliance Laundry Systems Drying Tumbler 70278501R5EN
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Alliance Laundry Systems Drying Tumbler 70278501R5EN non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Alliance Laundry Systems Drying Tumbler 70278501R5EN e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Alliance Laundry Systems in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Alliance Laundry Systems Drying Tumbler 70278501R5EN, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Alliance Laundry Systems Drying Tumbler 70278501R5EN, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Alliance Laundry Systems Drying Tumbler 70278501R5EN. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Installation/Operation Supplement www .comlaundry .com Drying T umblers 50 Pound Capacity 75 Pound Capacity Refer to page 3 for Model Identif ication Part No. 70278501R5EN December 2007 K eep These Instructions f or Futur e Reference. (If this machine changes o wnership, this manual must accompan y machine.)[...]
-
Pagina 2
[...]
-
Pagina 3
Installation/Operation Sup plement 70278501 (EN) 1 © Published b y permission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation must conf orm with local codes. IMPOR T ANT : Inf ormation must be obtained from a local gas supplier on instructions to be f ollowed if the user smells gas. These instructions must be posted in a pr omine[...]
-
Pagina 4
© Published b y permission of the copyright o wner . All rights reserv ed. No part of the cont ents of this book may be reproduced or transmitted in an y form or by an y means without the e xpressed written consent of the publisher . Installation/Opera tion Supplement 2 70278501 (EN) © Published b y permission of the copyri ght owner – DO NO T [...]
-
Pagina 5
© Published b y permission of the copyri ght owner – DO NO T COPY or TRANSMIT 3 70278501 (EN) Installation/Operation Sup plement Intr oduction Model Identification Information in this manual is applicable to these models: Includes models with the follo wing control suf fix es: Wiring Diagram The wiring diagr am is lo cated in the junction or con[...]
-
Pagina 6
© Published b y permission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Opera tion Supplement 70278501 (EN) 4 Serial Plate Location TMB803N 1 Serial Plate TMB803N 1 0 2 0 4 0 3 0 5 0 6 0 0 1 0 5 P U S H T O S T A R T H E AT C O O L D O W N H IG H T E M P E R A T U RE L O W 1 5 0 1 1[...]
-
Pagina 7
© Published b y permission of the copyri ght owner – DO NO T COPY or TRANSMIT 5 70278501 (EN) Installation/Operation Sup plement Safe ty Inf ormation Save These Instructions Impor tant Safety Instructions 1. Read all instructions before using the tumbler . 2. Refer to the GR OUNDING INSTR UCTIONS for the proper grounding of the tumbler . 3. Do n[...]
-
Pagina 8
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Opera tion Supplement 70278501 (EN) 6 22. Install this tumble r according to the INST ALLA TION INSTR UCTIONS . All connections for electrical po we r , grounding, and gas supply must comply with local codes and be made by licensed personnel when required[...]
-
Pagina 9
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT 7 70278501 (EN) Installation/Operation Sup plement Installation Specifications and Dimensions Specifications 50 P ound 75 P ound Noise le vel measured during oper ation at operator position of 1 meter ( 3.3 feet) in fr ont of machine and 1.6 meters (5.2 f eet) from fl[...]
-
Pagina 10
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Opera tion Supplement 70278501 (EN) 8 Cabinet Dimensions TMB2213N TMB2213N C B E D A G F M o d e l s ABCD E F G 050 Gas and Electric 781 mm (30.75 i n.) 717 mm (28.25 in.) 1194 mm (47 in.) 1946 mm (76.62 5 in.) 981 mm (38.625 in.) 838 mm (33 in.) 749 mm ([...]
-
Pagina 11
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Operation Sup plement 9 70278501 (EN) Horizontal Exhaust Outlet Locations TMB811N TMB811N A B C M o d e l s ABC 050/075 137 mm (5.375 in.) 203 mm (8 in.) 340 mm (13.375 in.)[...]
-
Pagina 12
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Opera tion Supplement 70278501 (EN) 10 Gas Connection Locations TMB812N TMB812N A B Models Diameter A B 050 1/2 in. NPT 394 mm (15.5 in.) 1670 mm (65.75 in.) 075 1/2 in. NPT 400 mm (15.75 i n.) 1670 mm (65.75 in.)[...]
-
Pagina 13
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Operation Sup plement 11 70278501 (EN) Electrical Connect ion Locations NO TE: These figu res ar e approximate dimensions only . TMB813N TMB813N GAS AND STEAM ELECTRIC A B B A Models A B Gas and Steam 241 mm (9.5 in .) 1613 mm (63.5 in.) Electric 483 mm ([...]
-
Pagina 14
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Opera tion Supplement 70278501 (EN) 12 Steam Connectio n Locations TMB814N TMB814N C A B D M o d e l s D i a m e t e r ABCD 050/075 3/4 in. NPT 387 mm (15.25 i n.) 1848 mm (72.75 i n.) 190 mm (7.5 in .) 1645 mm (64.75 in.)[...]
-
Pagina 15
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Operation Sup plement 13 70278501 (EN) P o sition and Le vel the T umbler Figure 1 NO TE: This manual is only a supplement. Refer to installation/operation ma nual f or full instructions. TMB2138N NO TE: Shade d areas indicate adjacent structure. 1 13 mm [...]
-
Pagina 16
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Opera tion Supplement 70278501 (EN) 14 Fire Suppression System W ater Requirements IMPOR T ANT : W ater must be supplied to the f ire suppression system, or the f ire suppression system will not operate as intended. Connection point to the electric water [...]
-
Pagina 17
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Operation Sup plement 15 70278501 (EN) Gas Requirements Natural Gas and Liquefied P etroleum IMPOR T ANT : Any product r evisions or con versions must be made by the Manufactur er’ s A uthorized Dealers, Distributors, or local service personnel. IMPOR T[...]
-
Pagina 18
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Opera tion Supplement 70278501 (EN) 16 European Gas General Inf or mation This information is to be used when installing gas tumblers in countries, and/or on gases, dif fere nt than the machine’ s factory configuration. T umblers are supplied from the f[...]
-
Pagina 19
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Operation Sup plement 17 70278501 (EN) Gases and Configurations Burner orifice information at 0-600 meters (0-2000 feet) altitude. N/A = Part no longer a vailable. * For Natural Gas, Group E+ appl ications, con vert using L.P . Gas model and replace burne[...]
-
Pagina 20
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Opera tion Supplement 70278501 (EN) 18 Exhaust Requirements Make-Up Air IMPOR T ANT : Do not obstruct the flow of combustion and v entilation air . A tumbler is forced air exhausted and requires provisions for mak e-up air to replace the air exhausted by [...]
-
Pagina 21
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Operation Sup plement 19 70278501 (EN) Electrical Requirements Grounding Instructions NO TE: T o ensure protection again s t shock, this tumbler MUST be electrically grounded in accordance with the local codes or , in the absence of local codes, with the [...]
-
Pagina 22
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Opera tion Supplement 70278501 (EN) 20 Steam Requirements Obtain specific steam serv ice pipe sizes from the steam system supplier or a qualified steam fitt er . ● Refer to Fi g u re 3 for proper steam pipe confi gurations. ● When tumbler is on the en[...]
-
Pagina 23
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Operation Sup plement 21 70278501 (EN) Figure 3 TMB2014N NO TE: Refer to Ta b l e 2 f o r sizing of steam lines. Piping must also be sized accordingly for length of runs, and number of elbows. 1 Supply 8 457 mm (18 in.) Drop 2 305 mm (12 in.) Riser 9 Sole[...]
-
Pagina 24
© Published b y per mission of the copyright owner – DO NO T COPY or TRANSMIT 70278501 (EN) 22 Installation/Opera tion Supplement Operation Emergenc y Stop Button on CE Models All CE appro ved OPL tumblers are f actory equipped with an emergenc y stop button located on the front panel. Refer to Fi g u re 4 . Figure 4 T o operate emergenc y stop [...]
-
Pagina 25
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Operation Sup plement 23 70278501 (EN) Contr ol Instructions Electr omechanical Coin Contr ol CD and CX Control Suffix es 1. Set the TEMPERA TURE selector at HIGH or LO W , or anywhere between these settings. Figure 5 2. Coin Drop Models: Insert the coin([...]
-
Pagina 26
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Opera tion Supplement 70278501 (EN) 24 Manual Timer Control MT and R T Control Suffixes 1. Set the HEA T/DR YING timer for the number of minutes (from 0-60) desired. 2. Set the COOL DO WN/COOLING timer for the number of minutes (from 0-15) desired. 3. Set[...]
-
Pagina 27
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Operation Sup plement 25 70278501 (EN) Dual Digital Timer Control QT and RQ Control Suffix es 1. Select HIGH, MED, LO W or NO HEA T by turning the temperature knob . 2. Set the HEA T TIME for the number of minutes (from 0-60) desired. 3. Set the COOL DO W[...]
-
Pagina 28
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Opera tion Supplement 70278501 (EN) 26 Single Dr op Control SD and SX Control Suffix es 1. Select HIGH, MED, LO W or NO HEA T by turning the temperature knob . 2. Insert the coin(s) in the coin slot. 3. Press ST AR T button to start tumbler . IMPOR T ANT [...]
-
Pagina 29
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Operation Sup plement 27 70278501 (EN) DMP OPL Control DO Control Suffix Figure 21 DMP OPL F ea tures The DMP has an 8 position DIP switch bank that is accessible from the back of the control board. By switching these DIP switches, it is possible for the [...]
-
Pagina 30
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Opera tion Supplement 70278501 (EN) 28 DMP Coin Control D V and DX Control Suffixes Figure 22 DMP Coin F ea tures ● ST AR T button to start or resume a c ycle. ● TEMP button to s elect HIGH, MEDIUM, or LO W temperature. ● T wo hidden buttons to incr[...]
-
Pagina 31
© Published b y per mission of the copyri ght owner – DO NO T COPY or TRANSMIT Installation/Operation Sup plement 29 70278501 (EN) Ignition Contr ol Operation Diagnostic LED (DGN LED) / Err or Codes The Diagnostic LED or DGN LED is located by the po wer connector on the ign ition control. Refer to F igure 23 . The Diagnostic LED will indicate th[...]
-
Pagina 32
© Published b y per mission of the copyright owner – DO NO T COPY or TRANSMIT 70278501 (EN) 30 Installation/Opera tion Supplement Disposal of Unit This appliance is marked according to the European directiv e 2002/96/EC on W aste Electrical and Electronic Equipment (WEEE). This symbol on the product o r on its packaging indicates that this produ[...]