Warning: mysql_fetch_array() expects parameter 1 to be resource, boolean given in /home/newdedyk/domains/bkmanuals.com/public_html/includes/pages/manual_inc.php on line 26
American Dryer Corp. Phase 7 OPL with S.A.F.E. Gas DSI AD-78 IV manuale d’uso - BKManuals

American Dryer Corp. Phase 7 OPL with S.A.F.E. Gas DSI AD-78 IV manuale d’uso

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55

Vai alla pagina of

Un buon manuale d’uso

Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso American Dryer Corp. Phase 7 OPL with S.A.F.E. Gas DSI AD-78 IV. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica American Dryer Corp. Phase 7 OPL with S.A.F.E. Gas DSI AD-78 IV o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso American Dryer Corp. Phase 7 OPL with S.A.F.E. Gas DSI AD-78 IV descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso American Dryer Corp. Phase 7 OPL with S.A.F.E. Gas DSI AD-78 IV dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo American Dryer Corp. Phase 7 OPL with S.A.F.E. Gas DSI AD-78 IV
- nome del fabbricante e anno di fabbricazione American Dryer Corp. Phase 7 OPL with S.A.F.E. Gas DSI AD-78 IV
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature American Dryer Corp. Phase 7 OPL with S.A.F.E. Gas DSI AD-78 IV
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio American Dryer Corp. Phase 7 OPL with S.A.F.E. Gas DSI AD-78 IV non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti American Dryer Corp. Phase 7 OPL with S.A.F.E. Gas DSI AD-78 IV e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio American Dryer Corp. in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche American Dryer Corp. Phase 7 OPL with S.A.F.E. Gas DSI AD-78 IV, come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo American Dryer Corp. Phase 7 OPL with S.A.F.E. Gas DSI AD-78 IV, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso American Dryer Corp. Phase 7 OPL with S.A.F.E. Gas DSI AD-78 IV. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    AD-78 IV (Phase 7 OPL with S.A.F.E. Gas DSI) Installation Manual For replacement parts, contact the reseller from which the dryer was purchased or American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 USA T elephone: (508) 678-9000 / Fax: (508) 678-9447 e-mail: techsupport@amdry .com www .amdry .com W ARNING: For your safety the infor[...]

  • Pagina 2

    Retain This Manual In A Safe Place For Futur e Refer ence American Dryer Corporation products embody advanced concepts in engineering, design, and safety . If this product is properly maintained, it will provide many years of safe, efficient, and trouble free operation. ONLY qualified technicians should service this equipment. OBSER VE ALL SAFETY P[...]

  • Pagina 3

    IMPOR T ANT YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPL Y AND THE GAS SUPPL Y BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE T O ALLOW ACCESS FOR CLEANING , ADJUSTING , INST ALLA TION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) ST ANDARDS. W ARNING CHILDREN SHOULD NOT BE ALLOWED T O PLA Y O[...]

  • Pagina 4

    W ARNING The dryer must never be operated with any of the back guards, outer tops, or service panels r emoved. PERSONAL INJUR Y OR FIRE COULD RESUL T . IMPOR T ANT PLEASE OBSER VE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer . Dryers must not be installed or stored in an area [...]

  • Pagina 5

    SECTION I IMPOR T ANT INFORMA TION ............................................................................... 3 A. Receiving and Handling ............................................................................................................... 3 B . Safety Precautions ......................................................................[...]

  • Pagina 6

    SECTION VII REVERSING TIMER SPIN/DWELL ADJUSTMENTS ..................................... 3 9 SECTION VIII DA T A LABEL INFORMA TION ............................................................................. 4 0 A. Data Label ..........................................................................................................................[...]

  • Pagina 7

    3 SECTION I IMPOR T ANT INFORMA TION A. RECEIVING AND HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery, the dryer and/or packaging, and wooden skid should be visually inspected for shipping damage. If any damag[...]

  • Pagina 8

    4 B. SAFETY PRECAUTIONS WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life. WARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESUL[...]

  • Pagina 9

    5 7. A program should be established for the inspection and cleaning of lint in the burner area, exhaust ductwork, and area around the back of the dryer. The frequency of inspection and cleaning can best be determined from experience at each location. WARNING: The collection of lint in the burner area and exhaust ductwork can create a potential fir[...]

  • Pagina 10

    6 SECTION II SPECIFICA TIONS/COMPONENT IDENTIFICA TION A. SPECIFICA TIONS Gas Shaded areas are stated in metric equivalents * Motor specifications are for non-reversing models only. Please consult factory for reversing specifications. ** S.A.F.E. system must be supplied with a 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) water supply. NOTE: ADC reserv[...]

  • Pagina 11

    7 Specifications AD-78 NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.[...]

  • Pagina 12

    8 B. COMPONENT IDENTIFICA TION 1. Dryer Front View Illus. No. Description 1 Controls 2 Control (top access) Door Assembly 3 Main Door Assembly 4 Lint Compartment Area (lint screen located behind door) 5 Data Label and Installation Label (affixed to the left side panel area behind the top control [access] door)[...]

  • Pagina 13

    9 2. Dryer Rear View Illus. No. Description 1 Heating Unit 2 Electric Service Relay Box 3 Electric Service Connections made here. 4 Basket (tumbler) Bearing Mount Assembly 5 Idler Bearing Mount Assembly 6 Basket (tumbler) (drive) Motor Assembly (for reversing models ONLY) 7 Leveling Leg (rear) 8 Blower Motor Assembly 9 Dryer Exhaust[...]

  • Pagina 14

    10 SECTION III INST ALLA TION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electri[...]

  • Pagina 15

    11 10. The dryer must be installed with provisions for adequate combustion and make-up air supply. CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6 months, inspect the exhaust ducting and remove any lint build up. IMPORTANT: Dryer must be installed in a location/environment, which the ambient temperature [...]

  • Pagina 16

    12 c. Remove the four (4) self-taping screws on the burner box that secure it to the top of the dryer shown in the illustration below . d. Remove the two (2) self-taping screws on the back electrical box and pull through ALL associated wires from the motor to this electrical box (refer to the illustration below ). e. Reverse procedure for installin[...]

  • Pagina 17

    13 C. DR YER ENCLOSURE REQUIREMENTS Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of 12-inches (30.48 cm) (18-inches [45.72 cm] or more is recommended for ease of installation, maintenance, and service) above the dryer outer top, except along the front of the dryer which may be partially closed in[...]

  • Pagina 18

    14 D. FRESH AIR SUPPL Y REQUIREMENTS When the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the make-up air is inadequate, drying time and drying efficiency will be adversely affected[...]

  • Pagina 19

    15 E. EXHAUST REQUIREMENTS 1. General Exhaust Ductwork Information Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back pressure which results in slow drying, increased use of energy, overheating of the dryer, and shutdown of the burner by the airflow (sail) switches, bu[...]

  • Pagina 20

    16 NOTE: As per the National Fuel Gas Code, “Exhaust ducts for Type 2 clothes dryers shall be constructed of sheet metal or other noncombustible material. Such ducts shall be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel not less than 0.0195-inches (26 gauge [0.05 mm]) thick.” IMPORTANT: Exhaust back pr[...]

  • Pagina 21

    17 IMPORTANT: Exhaust back pressure measured by a manometer in the exhaust duct must be no less than 0 and must not exceed 0.3 inches (0.74 mb) of water column (W.C.). IMPORTANT: Minimum duct size for a dryer that is vented vertically is 12-inches (30.48 cm) for a round duct or an equivalent of 80 square inches (516.1 square centimeters). THE DUCT [...]

  • Pagina 22

    18 F . ELECTRICAL INFORMA TION 1. Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL electrical connections, materials,[...]

  • Pagina 23

    19 2. Electrical Service Specifications IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel area behind the top control (access) door. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specifications of the data label exactly . IMPORTANT: Th[...]

  • Pagina 24

    20 3. Grounding A ground (earth) connection must be provided and installed in accordance with state and local codes. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation must conform to applicable Canada Standards: Canadian El[...]

  • Pagina 25

    21 If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord/ pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the dryer. b. 3-Phase (3ø) Wiring Connections ([...]

  • Pagina 26

    22 1) G as M odels The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, L3, and sometimes neutral) and ground. Single-phase (1ø) power for the control circuit is done internally to the dryer. No single-phase (1ø) input connection is required on a 3-phase (3ø) dryer. For gas dryers manufactured for operati[...]

  • Pagina 27

    23 2) E lectrically H eated M odels O nly The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, L3, and sometimes neutral) and ground. Single-phase (1ø) power for the control circuit is done internally to the dryer. No single-phase (1ø) input connection is required on a 3-phase (3ø) dryer. CAUTION: The dry[...]

  • Pagina 28

    24 c. 3-Phase (3ø) Wiring Connections (Hookup) For Reversing Models Only The electrical connections on ALL 3-phase (3ø) gas model dryers are made into the rear service box located at the upper left area of the dryer. Electrical connections for electrically heated dryers are made in the electric oven area located at the upper rear of the dryer. NO[...]

  • Pagina 29

    25 G . GAS INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL plumbing connections, materials, and workmanship must conform to the applicable requireme[...]

  • Pagina 30

    26 2. Technical Gas Data a. Gas Specifications * Measured at gas valve pressure tap when the gas valve is on. b. Gas Connections Inlet connection --- 3/4” N.P.T. Inlet supply size --- 3/4” N.P.T. (minimum) Btu/hr input -------- 204,000 (51,408 kcal/hr) 1) Natural Gas Regulation is controlled by the dryer’s gas valve’s internal regulator. In[...]

  • Pagina 31

    27 3. Piping/Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done by [...]

  • Pagina 32

    28 Consistent gas pressure is essential at ALL gas connections. It is recommended that a 3/4-inch (19.05 mm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.0 inches (29.9 mb) of water column (W.C.) pres[...]

  • Pagina 33

    29 H. PREP ARA TION FOR OPERA TION/ST AR T -UP The following items should be checked before attempting to operate the dryer: 1. Read ALL “ CAUTION ,” “ WARNING ,” and “ DIRECTION ” labels attached to the dryer. 2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label affixed to the left side p[...]

  • Pagina 34

    30 I. PREOPERA TIONAL TESTS ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions. 1. Turn on electric power to the dryer. a. Open AL[...]

  • Pagina 35

    31 NOTE: To check for proper sail switch operation, open the main door and while holding main door switch plunger in, start dryer. Dryer should start but heat circuit should not be activated (on). If the heat system is activated, the sail switch is improperly adjusted and must be adjusted by bending the actuator arm of the sail switch toward the bu[...]

  • Pagina 36

    32 8. Check to insure that ALL setscrews (i.e., basket [tumbler] drive, idler, etc.) are tight. J . PREOPERA TIONAL INSTRUCTIONS OPL MODELS 1. To start the dryer: a. Microprocessor Controller (Computer) Dryers... 1) Light emitting diode (L.E.D.) display will read “REAdY” (meaning no cycle in progress). 2) Press the letter on the keyboard (touch[...]

  • Pagina 37

    33 K. SHUTDOWN INSTRUCTIONS If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed: 1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker. 2. Discontinue the heat supply: a. GAS MODELS ...discontinue the gas supply . 1) SHUT OFF external gas supply shut[...]

  • Pagina 38

    34 SECTION IV SER VICE/P AR TS INFORMA TION A. SER VICE 1. Service must be performed by a qualified trained technician, service agency, or gas supplier. If service is required, contact the reseller from whom the ADC equipment was purchased. If the reseller cannot be contacted or is unknown, contact the ADC Service Department for a reseller in your [...]

  • Pagina 39

    35 SECTION V W ARRANTY INFORMA TION A. RETURNING WARRANTY CARDS 1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main door glass. These warranty cards are intended to serve the customer where we record the individual installation date and warranty information to better serve you should you file[...]

  • Pagina 40

    36 2. Each part must be tagged with the following information: a. Model number and serial number of the dryer from which part was removed. b. Nature of failure (be specific). c. Date of dryer installation. d. Date of part failure. e. Specify whether the part(s) being returned is for a replacement, a credit, or a refund. NOTE: If a part is marked fo[...]

  • Pagina 41

    37 SECTION VI ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer, as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location. Maximum operating efficiency is dependent [...]

  • Pagina 42

    38 90 DAYS 1. Remove lint from around basket (tumbler), drive motors, and surrounding areas. 2. Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment. 3. Clean any lint accumulation in and around both the blower and drive motor casing openings. EVERY 6 MONTHS Inspect and remove lint accumulation in customer furnis[...]

  • Pagina 43

    39 SECTION VII REVERSING TIMER SPIN/DWELL ADJUSTMENTS Timer models have an electronic reversing timer in the electrical service box, which is located in the upper left rear area of the dryer. Both the dwell (stop) time and the basket (tumbler) spin time are adjustable by mode selection switches located on the electronic timer (refer to the illustra[...]

  • Pagina 44

    40 SECTION VIII DA T A LABEL INFORMA TION A. DA T A LABEL Contact American Dryer Corporation When contacting American Dryer Corporation , certain information is required to insure proper service/parts information from ADC . This information is on the data label that is affixed to the left side panel area behind the top control (access) door. When c[...]

  • Pagina 45

    41 THE DATA LABEL 1. MODEL NUMBER The model number is an ADC number, which describes the size of the dryer and the type of heat (gas, electric, or steam). 2. SERIAL NUMBER The serial number allows ADC to gather information on your particular dryer. 3. MANUFACTURING CODE NUMBER The manufacturing code number is a number issued by ADC, which describes[...]

  • Pagina 46

    42 SECTION IX PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 1. Microprocessor Controller (Computer) Board a. Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer. b. Start the drying cycle by pressing any of the preset cycles in letters A-F. c. Verify that the applicab[...]

  • Pagina 47

    43 2. For Models With Johnson Controls Direct Spark Ignition (DSI) Module (G760) Theory Of Operation: Start the drying cycle. When the gas burner ignites within the chosen trial for ignition time (6-seconds), the flame sensor detects gas burner flame and signals the DSI module to keep the gas valve open...as long as there is a call for heat. The DS[...]

  • Pagina 48

    44 SECTION X SENSOR ACTIV A TED FIRE EXTINGUISHING ( S.A.F.E .) SYSTEM The exclusive Sensor Activated Fire Extinguishing (S.A.F.E.) System will extinguish fires that may start in the drying basket (tumbler). A series of sensors positioned throughout the basket (tumbler) and interfaced with the microprocessor will trigger the S.A.F.E. system water j[...]

  • Pagina 49

    45 BEFORE YOU START! CHECK LOCAL CODES AND PERMITS Call your local water company or the proper municipal authority for information regarding local codes. IMPORTANT: It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the plumbing installation is adequate and conforms to local, state, and federa[...]

  • Pagina 50

    46 2. Water Connections: The water connection is made to the 1/2” M.P.T. bushing of the electric water solenoid valve located at the rear upper left area of the dryer (see photo). The water solenoid valve has a 3/8” M.P.T. connection and a 1/2” bushing is supplied to provide the minimum 1/2” supply (feed) line. Flexible supply line/coupling[...]

  • Pagina 51

    47 OPTIONAL MANUAL BYPASS Provisions are made in the dryer Sensor Activated Fire Extinguishing (S.A.F.E.) system for the installation of an optional manual bypass. Depending on the model dryer, the connections for the manual bypass are made at the “T” or “four way” fitting located in the outlet supply side of the water solenoid valve. The u[...]

  • Pagina 52

    48 Sensor Activated Fire Extinguishing (S.A.F.E.) System Theory of Operation While the dryer is in an idle state or 20-seconds after the heat turns off, the Phase 7 control monitors the S.A.F.E. system probe located in the top of the basket (tumbler) chamber and records the minimum temperature. If the minimum recorded S.A.F.E. system probe temperat[...]

  • Pagina 53

    49 Sensor Activated Fire Extinguishing (S.A.F.E.) System Parts Break Down Replacement parts can be obtained from your reseller or the ADC factory. When ordering replacement parts from the factory, you can FAX your order to ADC at (508) 678-9447 or telephone your order directly to the ADC Parts Department at (508) 678-9000. Please specify the dryer [...]

  • Pagina 54

    50 Illus. No. Part No. Qty. Description 1 822752 1 S.A.F.E. System Temperature Probe Assembly (includes illus. nos. 1 through 5) 2 154007 2 Push On Fastener 3 390390 1 Sensor Bracket ONLY 4 150301 2 #8-18 x 7/16” Phillips Pan Head TEK Screw 5 122647 1 Connector O NL Y ( does not include terminals)[...]

  • Pagina 55

    ADC 113164 1 - 01/16/03-25 2 * 02/27/03-25 3 * 05/09/03-50[...]