American Power Conversion 5000 VA manuale d’uso
- Visualizza on-line o scarica il manuale
- 23 pagine
- 0.46 mb
Vai alla pagina of
Manuali d’uso simili
-
Power Supply
American Power Conversion AP9215
20 pagine 0.29 mb -
Power Supply
American Power Conversion 480kW
32 pagine 0.93 mb -
Power Supply
American Power Conversion 420/620
2 pagine 0.1 mb -
Power Supply
American Power Conversion 8000VA
21 pagine 0.45 mb -
Power Supply
American Power Conversion SYMSTRF3I
68 pagine 5.63 mb -
Power Supply
American Power Conversion POWERCELL
36 pagine 0.27 mb -
Power Supply
American Power Conversion XS 450 -48
48 pagine 2.58 mb -
Power Supply
American Power Conversion SURT48XLBP
27 pagine 0.73 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso American Power Conversion 5000 VA. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica American Power Conversion 5000 VA o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso American Power Conversion 5000 VA descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso American Power Conversion 5000 VA dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo American Power Conversion 5000 VA
- nome del fabbricante e anno di fabbricazione American Power Conversion 5000 VA
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature American Power Conversion 5000 VA
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio American Power Conversion 5000 VA non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti American Power Conversion 5000 VA e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio American Power Conversion in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche American Power Conversion 5000 VA, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo American Power Conversion 5000 VA, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso American Power Conversion 5000 VA. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
990-2690 0 2/2006 User Manual English APC Smart-UPS ® RT 3000/500 0 VA 200-240 VAC Tower/Ra ck Mount 3U Uninterrupti ble Power Supply[...]
-
Pagina 2
[...]
-
Pagina 3
1 Introduction The APC Sm art-UPS® RT is a h igh-perf ormance, unint erruptible pow er supply (UPS) that prov ides protection for electron ic equipment from utilit y po wer blackou ts, brownouts, sags and surges. The UPS filters small utilit y line fluctuations and isolates electronic equip ment from large disturbances by in ternally disconn ectin[...]
-
Pagina 4
2 Wiring and Connecting the UPS 5000 VA XLI MO DELS O NLY : H ARDWIRING I NSTRUCTIONS • Wiring must be performe d by a qualif ied electrician. • Install a high magnetic 30/32 A utility circuit br eaker. • Adhere to all national and local electrical codes. • Use #10 A WG gauge (5 mm 2 ) w ir e. 1. Switch the utility circuit breaker OFF. 2. R[...]
-
Pagina 5
3 C ONNECTING THE B ATTE RY MODULES AND A TTACHING THE F RONT B EZEL [...]
-
Pagina 6
4 B ASIC C ONNE CTORS serial com The serial connector is to be u sed for interf acing with APC Po w erChute software and terminal emulation software. Use only cables appro ved by APC. Any other interface cable will be incompatible with the UPS connector. normal bypass Manual bypass enables t he user to manually put connected eq uipment into bypass [...]
-
Pagina 7
5 C ONNECTING E QUIPME NT AND P OWER TO TH E UPS 1. Connect equ ipment to the UPS (cables not included for XLJ/XLT/XLTW m odels). 2. Avoid using exte nsion cords. • 3000 VA XLJ/ XLT/XLI/XL TW and 5000 VA XLJ/ XLT/XLTW models : Using a pow er cord, plug the UPS into a two- pole, thr ee-wire, grounded receptacle only . • 5000 VA XLJ model s: To d[...]
-
Pagina 8
6 O PERA TION Load S MART -U PS RT F RONT D ISPLAY Battery Charge Indicator Description Online The Online LED il luminates when th e UPS is drawing utility powe r and performing double con version to supply power to con nected equipment. On Battery The UPS is supplying battery po w er to the connected equi pment. Bypass The Bypass LED ill uminates [...]
-
Pagina 9
7 Feature Function Cold Start When there is no utility po wer and the UPS is off, press and hold the button to power up th e UPS and connected equipment. The UPS will emit two beeps. During the second beep, release the bu tton. Self-Test Automatic: The UPS performs a s elf-test automatically when turned on, and ev ery two weeks thereafter (by defau[...]
-
Pagina 10
8 U SER C ONFIGU RA BLE I TEMS N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OW E R C HUTE SOFTW ARE , OPTIONAL S MA RT S LO T ACCESSO RY CARDS , OR T ER MI NAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRI PTION Automa tic Self-Tes t On start-up a nd eve ry 14 day s, thereafter On start-u p and every 7 days thereafter On s[...]
-
Pagina 11
9 N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OW E R C HUTE SOFTW ARE , OPTIONAL S MA RT S LO T ACCESSO RY CARDS , OR T ER MI NAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRI PTION Low Bypass Point 160 VA C Output Volta ge Settin g 200 VAC: 160 - 185 VA C 208 VAC: 160 - 190 VA C 220 VAC: 160 - 195 VA C 230 VAC : 160 - 20[...]
-
Pagina 12
10 C ONNECTING THE EPO (E MERGENCY P OWER O FF ) O PTION The output pow er can be disabled in an emergen cy b y clos ing a switch connected to the EPO. Adhere to National and local electrical codes wh en wiring the EPO. The EPO switch is intern ally po wered by t he UPS for us e with non-po w ered switch circuit breakers. The EPO circuit is conside[...]
-
Pagina 13
11 T ERMI NAL M OD E TO C ONFIGURE UPS P ARAMETE RS 3000 VA m odels: Terminal Mode is a menu driven interface that enables configuration of the UPS by users not wi shing to use P o werChut e ® soft ware or an o ptio nal Ne twork M ana geme nt Car d. Connect the serial cable to th e serial co m con nector on the back of the UPS. If Pow erChute sof [...]
-
Pagina 14
12 5000 VA m odels: Terminal Mode is a menu driven interface that enables configuration of the UPS by users not using Pow erChute ® software or the ins talled Network Manageme nt Card interf aces. Connect the serial cable to the serial port on the back of th e UP S. If Pow erChute sof tware is not in stalled do not perform steps 1 and 5. 1. For W [...]
-
Pagina 15
13 • Press 2 and ENTE R to change the Battery Settings. • Type in the number of external battery packs (four batt ery modules per pack ), and press E NTE R. (Num ber of packs: 1 = 1 S URT192XLBP, 2 = 2 SURT192XL BP etc.) • Press 3 and ENTER to accept the changes. • Press ESC multiple times (5) to return to the main menu. • Press 4 an d EN[...]
-
Pagina 16
14 M AIN TE N AN C E AN D T RA NSPOR T Replacing the Battery Module This UPS has an easy to replace, h ot-swappable battery module. Replacement is a safe procedure, isolated from electrical hazards. You may leave the UPS and connected equipm ent on during the procedure. See y our dealer or contact APC at th e Web site, www.apc.com for infor m atio [...]
-
Pagina 17
15 R EPLACING B ATTERY MODULES X Y Z [ ] ^ _ Disconnecting the Battery for Transport Alway s DISCONNECT THE B ATTERY(s) befo re ship ping in compliance with U.S. Departm ent of Transportation (DOT) and I ATA regulations. The battery(s) m ay remain in the UPS. 1. Shut down an d disconnect any equipment attach ed to the UPS. 2. Shut down and di[...]
-
Pagina 18
16 T ROUBLESHOOTING , S ER VICE , AN D W A RRA NTY I N FORMA T ION Use the table below to solve minor installation and op eration problems. Refer to the AP C Web site, www.apc.com for assistan ce with complex UPS problems. P ROBLEM AND P OSSI BLE C AUSE S OLUTION UPS WILL NOT TURN ON Batt ery not conn ected p rop erly. Check t hat the b atter y con[...]
-
Pagina 19
17 P ROBLEM AND P OSSI BLE C AUSE S OLUTION BYPASS LED ILLUM INA TES The bypass swi tch ha s been turne d on m anually or throu gh an acce ssory . If bypa ss is t he chosen mode of oper ation, ignore t he illum inated L ED. If bypa ss is not the chos en mode of op era tion move t he bypas s swit ch on the back o f the UPS , to th e normal posit ion[...]
-
Pagina 20
18 Service If the UPS requires service do not return it to the dealer. Follow these s teps: 1. Revi e w the problems discussed in th e Troubleshoot ing section of this manual to eliminate common problem s. 2. If th e problem persis ts, contact APC Customer Support t hrough the APC Web site, www.apc.com . • Note the m odel number of the UPS, the s[...]
-
Pagina 21
19 R EGULA TOR Y Regulatory Agenc y Approvals a nd Radio F reque ncy Warnings 200, 208, 22 0, 230, 240 V MODELS This e quipm ent has bee n teste d and f ound to com ply with the limits f or a Class A digi tal de vice, p ursua nt to part 15 of t he FCC Ru les. Th ese limi ts are des igned t o provid e reason able p rotect ion a gainst ha rmfu l inte[...]
-
Pagina 22
20 Declaration of Conformity[...]
-
Pagina 23
21 A PC Worldwi de C ustomer Support Custom er support for th is or any other APC produ ct is available at n o charge in any of the following wa ys: • Refer to th e APC Web site to access documents in the APC Knowledg e Base and to submit customer su pport requests . • www.apc.com (Corporate H eadquarters) Connect to localized A PC Web sites fo[...]