American Power Conversion SUDP8000I manuale d’uso
- Visualizza on-line o scarica il manuale
- 24 pagine
- 0.81 mb
Vai alla pagina of
Manuali d’uso simili
-
Power Supply
American Power Conversion ES 500
1 pagine 0.19 mb -
Power Supply
American Power Conversion AIS 3000
60 pagine 11.2 mb -
Power Supply
American Power Conversion SL-300TFX
27 pagine 0.73 mb -
Power Supply
American Power Conversion K250EI
40 pagine 0.29 mb -
Power Supply
American Power Conversion 240-320kW 480V
31 pagine 1.6 mb -
Power Supply
American Power Conversion 100VAC
27 pagine 0.73 mb -
Power Supply
American Power Conversion 220 VAC
21 pagine 0.39 mb -
Power Supply
American Power Conversion 250 VA
16 pagine 0.42 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso American Power Conversion SUDP8000I. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica American Power Conversion SUDP8000I o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso American Power Conversion SUDP8000I descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso American Power Conversion SUDP8000I dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo American Power Conversion SUDP8000I
- nome del fabbricante e anno di fabbricazione American Power Conversion SUDP8000I
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature American Power Conversion SUDP8000I
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio American Power Conversion SUDP8000I non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti American Power Conversion SUDP8000I e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio American Power Conversion in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche American Power Conversion SUDP8000I, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo American Power Conversion SUDP8000I, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso American Power Conversion SUDP8000I. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
990-1007A , Rev ision 2 9/99 Smart-UPS DP Uninterruptible Pow er Supply Models SUDP4000I, SUDP6000I, SUDP8000I, SUDP10000I User’s Manual[...]
-
Pagina 2
Entire con tents copyrig ht ©1999 by A meri can Pow er Conv ersion. A ll rig hts res erved. Reprodu ction i n w hole or in part with out permission is prohibited. Smart- UPS is a registered trademark of A PC. All other trademark s are the property of their respective ow ners . 990-1007A , Rev ision 2 9/99[...]
-
Pagina 3
990-1007A , Rev ision 2 9/99 Smart-UPS DP Quick Reference Guide English About Your New UPS This Uninterruptible Power Supply (UPS) prevents blackouts, brow nouts, s ags an d surges from reaching you r comput er and other valuable electronic equipm ent, filters out u tility line fluctu ations, and is olates y our equipm ent from distu rbances by act[...]
-
Pagina 4
[...]
-
Pagina 5
990-1007A , Rev ision 2 9/99 i Table of Contents Safety ......................................................................................................................................................................................................... 1 Handling Saf ety .........................................................................[...]
-
Pagina 6
990-1007A , Rev ision 2 9/99[...]
-
Pagina 7
990-1007A , Rev ision 2 9/99 1 Safety This Sa fety G uide contains importa nt instructions tha t should be f ollowe d during insta llation and m aintenanc e of the APC equipm ent and ba tteries . It is intended f or APC customer s who setup, install, re locate, or m aintain A PC equipment. Handling Safety • Be ca ref ul. Do not lift hea vy loads [...]
-
Pagina 8
990-1007A , Rev ision 2 9/99 2 Initial Insp ection Inspection Inspect the UPS upon receipt. Notif y th e carrier and dealer if th ere is damag e. The packaging is recyclable; sav e it for reuse or dis pose of i t properly . Unpacking Move the UPS, in its s hipping pack age, as close to th e desired location as poss ible. Then follow these in struct[...]
-
Pagina 9
990-1007A , Rev ision 2 9/99 3 Placement Sm a r t - U P S D P Sm a r t - U P S D P Sm a r t - U P S D P Install the UPS in a protected area th at is free of ex cessive dust an d has adequate air f low . Suff icient cooling mu st be ensu red by a m ini mu m of 150 mm f ree space from the ventilation slots on th e back, and 200 m m f rom th e ventila[...]
-
Pagina 10
990-1007A , Rev ision 2 9/99 4 Externa l Connections Notes: As a standar d, the S mart-UPS DP is made for sing le-phase connecti on. Due to the leakage current of 3 .5 t o 10 mA, the Smart-UPS DP mu st alw ay s be grounded according to local reg ulations. Mains Connections Make these connections only if no optional equipment (see the Optiona l Equi[...]
-
Pagina 11
990-1007A , Rev ision 2 9/99 5 Rear Views F 0 0 1 M a i n s F 0 0 1 M a i n s 16) 15) 14) 13) 12) 11) 10) 9) 8) 7) 6) 5) 4) 3) 2) 1) A DC AH MIN. : STO RED E NERG Y TIME OU TPUT : INPUT : AH V DC / V / 2. REPLACEMENT 1. REPLACEMENT INSTA LLE D YEAR MONTH REPLACEMENT OF B AT TE RI E S KG. WEIGHT: S. NO. : TYPE: P .NO. : RECORD THE DATE OF RE PLACEME[...]
-
Pagina 12
990-1007A , Rev ision 2 9/99 6 Common Fault The function of the com mon fault relay is factory preset. For ch anging the factory setting, please contact y o ur local dealer. Principa l Diagram (common fault) 1 NC 2 NO 3 Com 4 Com Data: Relay contacts - ohmi c load DC m in./m ax.: 12V DC 20m A/ 60V DC 1A AC m in./max.: 12V AC 20mA/ 250V AC 8A Comput[...]
-
Pagina 13
990-1007A , Rev ision 2 9/99 7 14 NC1 15 NC1 NO1 2 COM1 NO1 COM1 CHGND X005 EPO RELAY CONNECTOR 16 NC2 17 NC2 NO2 4 COM2 NO2 COM2 CHGND 18 NC3 19 NC3 NO3 6 COM3 NO3 COM3 CHGND 20 NC4 21 NC4 NO4 8 COM4 NO4 COM4 CHGND ON/OFF RELAY BYPASS OPERATION RELAY BATTERY OPERATION RELAY BATTERY LOW WARNING RELAY EPO RELAY PC BOARD RELAY FUNCTION +V 11 12 PSU_P[...]
-
Pagina 14
990-1007A , Rev ision 2 9/99 8 Optional Equipment I nst allation Galvanic Isolation T ransformer The galvanic is olation transf ormer can be delivered for one- or two- phase conn ection. When con necting a Sm art-UPS DP and galvanic isolation transf ormer, the A C bus and the w ires for the thermo sw itch m ust be mounted. Please follow the instruc[...]
-
Pagina 15
990-1007A , Rev ision 2 9/99 9 Standard S ystem With Is olating Trans form er (400 V) System Ma ins Fuse* (Fm ) Input Cable Trans form er Input Cable UPS Output Cable UPS 4kV 16A 3x2.5mm ² 3x6m m² 3x4 mm ² 6kV 25A 3x6 m m² 3x16 m m² 3x10 m m² 8kV 32A 3x10 mm ² 3x16 mm ² 3x10 mm ² 10kV 40A 3x10 m m² 3x16 m m² 3x16 m m² *Di n g l T yp e s[...]
-
Pagina 16
990-1007A , Rev ision 2 9/99 10 External Service Bypass Panel ( SBP) Note: The Sm art-UPS DP must only be conn ected by service bypass panels (SBPs) man ufactured by APC. If SBP s other than th ose manufactured by A PC are us ed, the UPS s yst em m ay be damaged and the w ar ranty give n by AP C is re pealed. During the installation of the service [...]
-
Pagina 17
990-1007A , Rev ision 2 9/99 11 UPS N L N L INPUT CABLE SBP MAINS L N PE LOAD L N OUTPUT CABLE SBP SBP L N L N Input cable UPS Output cable UPS Fm Fo 1 2 3 4 MBS CONTROL SBP CABLE X010 1 2 3 4 External Service Bypass Panel an d Galvan ic Isolation T ransformer If both the extern al service bypass panel and the galv anic isolation transform er are i[...]
-
Pagina 18
990-1007A , Rev ision 2 9/99 12 Standard S ystem With Is olating Trans form er (400 V) And SBP System Ma ins Fuse* (Fm ) Input Cable Trans form er Input Cable UPS Output Cable UPS 4kV 16A 3x2.5mm ² 3x6m m² 3x6 mm ² 6kV 25A 3x6 m m² 3x16 m m² 3x10 m m² 8kV 32A 3x10 mm ² 3x16 mm ² 3x10 mm ² 10kV 40A 3x10 m m² 3x16 m m² 3x16 m m² *Di n g l[...]
-
Pagina 19
990-1007A , Rev ision 2 9/99 13 Operating Instructions Switching On F 0 0 1 M a i n s Switch on the m ains fuse on th e rear of the UPS. The Smart-UPS DP will perform a self-check ending w ith the LED display sh owing red/yellow /green, m eaning that th e unit is fu nctioning properly. The unit perform s a self-t est autom atically w hen turned on [...]
-
Pagina 20
990-1007A , Rev ision 2 9/99 14 LEDs The LED bar on the f ront of th e unit gi ves inf ormation by m eans of color and size of the bar. [ MUTE ] Bat tery Oper . Che ck Ba tt er y Green Y ellow No rma l Ope r . Recharging Bat t . [ 100 % ] [ 50 % ] [ 25 % ] [ 75 % ] Overload Red Bypass / Failure The gener al meaning is : Green = Okay . Yellow = Okay[...]
-
Pagina 21
990-1007A , Rev ision 2 9/99 15 Batteries A utomatic Battery Check The battery test is autom atically carried out every third month, if the au tomatic battery test function is set. The battery tes t starts w hen the batteries are fu lly ch arged. There is no alarm given for the battery operation and the dis play sh ow s norm al operation. Manual Ba[...]
-
Pagina 22
990-1007A , Rev ision 2 9/99 16 Sp ecifications SUDP4000I SUDP 6000I SUDP8000I SUDP10000I Acceptable input v oltage 220/230/240V +10%/-15% no rmal o peration ± 10% by pass operatio n Inpu t v oltage (on-lin e ope ration) 220/230/240 VAC 230 vo lt ou tput rang e 220/230/240 VAC Nom inal input frequ ency 50 or 60 Hz Inpu t protectio n Rese ttable ci[...]
-
Pagina 23
990-1007A , Rev ision 2 9/99 17 Regulatory A gency A pprovals N 3 94 B ME 61 geprüfte Sicherheit[...]
-
Pagina 24
990-1007A , Rev ision 2 9/99 18 A PC Contact Information Internet ht tp : / / www. a p cc . c o m Latin A merica, South A merica Arge ntina................ 0800.9.APCC (0800.9.2722) Mexico ............................... 95.800.804.4283 Brazil...................... 0800.12.72.21 Ur uguay.............................. 000.413.598.2139 Colom bia ....[...]