American Standard TWE050AD**E manuale d’uso
- Visualizza on-line o scarica il manuale
- 28 pagine
- 2.05 mb
Vai alla pagina of
Manuali d’uso simili
-
Heat Pump
American Standard TWE180B***E
28 pagine 2.05 mb -
Heat Pump
American Standard TWE060A***E
28 pagine 2.05 mb -
Heat Pump
American Standard TWE240B***F
28 pagine 2.05 mb -
Heat Pump
American Standard TWE200BD**F
28 pagine 2.05 mb -
Heat Pump
American Standard TWE155BD**E
28 pagine 2.05 mb -
Heat Pump
American Standard Split System Cooling or Heat Pump Air Handler
28 pagine 2.05 mb -
Heat Pump
American Standard TWE060B***E
28 pagine 2.05 mb -
Heat Pump
American Standard TWE090A***E
28 pagine 2.05 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso American Standard TWE050AD**E. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica American Standard TWE050AD**E o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso American Standard TWE050AD**E descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso American Standard TWE050AD**E dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo American Standard TWE050AD**E
- nome del fabbricante e anno di fabbricazione American Standard TWE050AD**E
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature American Standard TWE050AD**E
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio American Standard TWE050AD**E non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti American Standard TWE050AD**E e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio American Standard in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche American Standard TWE050AD**E, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo American Standard TWE050AD**E, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso American Standard TWE050AD**E. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
Installation Oper ation Maint enance October 2006 TW E - SV X 0 3 C - E N Models (60 Hz) Models (50 Hz) TWE060A*** E TWE050AD**E TWE060B*** E TWE075AD**E TWE090A* **E TWE1 00AD** E TWE090B* **E TWE1 00BD** E TWE1 20A***F TWE1 55 BD**E TWE1 20B***E TWE2 0 0BD**F TWE180B***E TWE240B*** F Split S yst em Cooling or Heat Pump Air Handler 7½ - 20 T ons [...]
-
Pagina 2
Pr ef ace and W ar nings and Cautions © 20 06 American Standard Inc. All rights reserved TWE-SVX03C-EN Li terat ure Ch an ge H isto ry TWE-S VX03A-EN (J une 20 03) Implemented Global G raphics format to IOM. TWE-SVX03B-EN (April 20 05) Added capacitor discharge w arn ing. TWE-SVX03C-EN (S epte mber 200 6) Model number for 20 0 and 240 we nt to an [...]
-
Pagina 3
Cont ents TWE-SVX03C-EN 3 Model Number Descr iption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 General I nfor mation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation Ch ecklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]
-
Pagina 4
4 TWE-SVX03C-EN Model Number Description All products are identi fied by a multiple-c haracter model numb er that precisely identifies a particular type of unit. An explanation of the alphanumeric identification code is provid ed. Its use will enable the owner/operator , installing contractors, and se rvice engineers to define the operat ion, speci[...]
-
Pagina 5
TWE-SVX03C-EN 5 General This manual covers installation of the TWE050, 060, 0 75, 090,1 0 0 and 120A single circuit air handlers and TWE060, 075, 090, 1 0 0, 120, 155, 180, 20 0 and 240B dual circuit air handler s. These air handl er models incorporate a sing le slab coil assembly , improved applic ation flexibility , servicing, maintenance accessi[...]
-
Pagina 6
6 TWE-SVX03C-EN Unit Dimensions Figure 1 . Unit Dimensions[...]
-
Pagina 7
TWE-SVX03C-EN 7 Unit Dimensions Figur e 1 . (continued fr om previous page)[...]
-
Pagina 8
8 TWE-SVX03C-EN Unit Dimensions Figure 2.[...]
-
Pagina 9
TWE-SVX03C-EN 9 Unit Dimensions Figure 3.[...]
-
Pagina 10
10 TWE-SVX03C-EN Installation Pr eparations The final position for th e air handler must be dictated by required service access to it, weight distribution ov er structural suppor ts, and by the locations of electr ical, refrigerant and condensate draina ge connections. Af ter this is determined, the followin g preparations should be made. Repositio[...]
-
Pagina 11
TWE-SVX03C-EN 11 Installation Refr iger ant Piping Prepar ation The air handler is d esigned so that refrigerant piping can enter from either the right or lef t hand side. It is shipped with the intent that the refrigerant lines will enter from the left hand side. T o convert to right hand entry , unbraz e the elbow on the suction line and ro tate [...]
-
Pagina 12
12 TWE-SVX03C-EN Installation Caution Equipment D amage! Befor e hanging the unit on suspension ro ds, reinf orce the cabinet ar ound the knock outs b y using a larg e washer inside the cabinet. W ashers should be betw een the skin of the air handler and the nut on the suspensio n r od. Align holes (knoc kouts) in the cabinet with structural suppor[...]
-
Pagina 13
TWE-SVX03C-EN 13 Installation Note : Important! When air handler is installed in the ver tical position and close proximity trapping of co ndensate is required, use of a subbase accessory to raise the air handler for clearance of the drain trap is recommended. See Figure 6 for a typical drain trap assembly . Filters Air handler s are shipped wi th [...]
-
Pagina 14
14 TWE-SVX03C-EN Installation WA R N I N G Hazar dous V oltage! Disconnect all ele ctr ic pow er , including r emote discon nects befor e servicing. F ollo w proper lo ck out/ tagout pr ocedures t o ensure the pow e r can not be inadvert ently energiz ed. Failur e to disconnect pow e r bef ore servicing could result in death or ser ious injury [...]
-
Pagina 15
TWE-SVX03C-EN 15 Ther mostat and Contr ol Connections 1 . Observe all notes on the diagrams. 2. Mount the thermostat in the desired location. 3. Install color coded low voltage cables between outdo or unit, indoor unit and th ermostat. 4. Connect low v oltage control wiring to th e low vo ltage terminal board located on the side of the fan c o ntro[...]
-
Pagina 16
16 TWE-SVX03C-EN Field Wiring b. 3 power wires. Line voltage for 3 phase; 2 wires for single phase. c. Heat pum p thermostat: 6 wires, 24 volts. i. Electric heat: add 2 additional wire, 24 volts. d. 2 wires, 24 volts. i. Outdoor therm ostat; add 1 additional wire, 24 volts. ii. Electric heat: add 1 additional wire, 24 volts. (2) T T_060/TTE120B (2)[...]
-
Pagina 17
TWE-SVX03C-EN 17 Field Wiring Figure 1 1 . TT A090 A, 120A/T WE090A, 120A; TT A075A, 1 0 0A/TWE075A, 1 0 0A Figur e 12. TT A120B/TW E120B; TT A120C/T WE1 20 A; T T A1 00B/ T WE1 00B ; T T A1 00C /T WE1 00A[...]
-
Pagina 18
18 TWE-SVX03C-EN Field Wiring Figure 13. TW A090A, 120A/TWE090A, 120A; TW A075A, 1 0 0A/TWE075A, 1 0 0A Figur e 14. TT A120B/TW E120B; TT A120C/T WE1 20 A; T T A1 00B/ T WE1 00B ; T T A1 00C /T WE1 00A[...]
-
Pagina 19
TWE-SVX03C-EN 19 Field Wiring Figure 15. TT A090A, 12 0A/T WE0 90A, 120A; TT A075A, 1 0 0A/TWE075A, 1 0 0A Figure 16. T W_060/TWE060; TW_050/TWE050[...]
-
Pagina 20
20 TWE-SVX03C-EN Field Wiring Figure 1 7 . TW_060/T WE0 60; TW_050/T WE050 Figure 1 8. TW_060/T WE0 60; TW_050/T WE050[...]
-
Pagina 21
TWE-SVX03C-EN 21 Field Wiring Figure 19. TW_030/T WE0 60B; T W___/TWE090B; T W_060/TWE120B; TW_050/T WE1 0 0B Figure 20. TW_030/T WE0 60B; T W___/TWE090B; T W_060/TWE120B; TW_050/T WE1 0 0B[...]
-
Pagina 22
22 TWE-SVX03C-EN Field Wiring Note : Wiring shown with dash ed lines is to be furni shed and installed by the customer . All customer -supplied wiring must be copper only and must conform to NEC and local electrical codes. Codes may require line of sig ht between the disconnect switc h and the unit. Note : When electric heater accessory is used, si[...]
-
Pagina 23
TWE-SVX03C-EN 23 Field Wiring Figure 22. TT A150 B , 1 80 B , 240B/TWE1 80B, 240B; TT A1 25B , 155B, 200B/TWE155B, 200B; TT A155C/T WE155B; TT A180C/TWE1 80 B Figure 23. TT A150B, 180B , 240B/TWE 1 80B, 240B; TT A125B, 155B, 200B/TWE155B, 200B; TT A155C/TWE155B; TT A180C/TWE1 80 B[...]
-
Pagina 24
24 TWE-SVX03C-EN Field Wiring Figure 2 4. T W A180B, 240B/T WE 180B, 240B; TW A155B, 200B/TWE 155B , 200B Figure 25. TW A 090A, 120A/TWE 1 80B, 240B; TW A075A, 1 00 A/T WE 155B, 200B[...]
-
Pagina 25
TWE-SVX03C-EN 25 Field Wiring Figure 26. TT A090A, 12 0A/T WE 180B, 240B; T T A075A, 1 0 0A/TWE155B, 240B Figure 27 . TT A090A, 120A/TWE 1 8 0B , 240B; TT A075A, 1 0 0A/TWE155B , 200B[...]
-
Pagina 26
26 TWE-SVX03C-EN Field Wiring Figur e 28. T W_030A/TWE060B; T W___/TWE090 B; TW_060/T WE120B; TW_050/TW E1 00B[...]
-
Pagina 27
TWE-SVX03C-EN 27 TT A , TTN , TTP , TTR , TT B, TT X, TTY an d TTZ (par ts only) This war ranty is extended by American Standa rd to the orig inal purc haser and to any succ eeding owner of the real property to whic h the Air Conditioner is origin ally affixed, and applies to products purc hased and retained for use within the U. S.A. and Canada. T[...]
-
Pagina 28
Literature Orde r Number TWE-SVX03C-EN Date October 20 06 Super sedes TW E-SVX03C-0906 Stoc king Location W ebbMason The manufacturer has a policy of continuous product and product data improvement and reserves the right to c hange design and specification s without notice.[...]