BlueWalker PowerWalker VFI 40000TP 3/3 BX manuale d’uso
- Visualizza on-line o scarica il manuale
- 36 pagine
- N/A
Vai alla pagina of
Manuali d’uso simili
-
Uninterruptible power supply (
BlueWalker VI 2000 PSW
64 pagine -
Uninterruptible power supply (
BlueWalker VFI 1000R LCD
98 pagine -
Uninterruptible power supply (
BlueWalker PowerWalker VFI 1000 LCD
141 pagine -
Uninterruptible power supply (
BlueWalker PowerWalker VFI 3000RM LCD
140 pagine -
Uninterruptible power supply (
BlueWalker 10120128
90 pagine -
Uninterruptible power supply (
BlueWalker PowerWalker VFI 1000RT LCD
44 pagine -
Uninterruptible power supply (
BlueWalker PowerWalker VFI 10000P/RT LCD
65 pagine -
Uninterruptible power supply (
BlueWalker PowerWalker VFI 3000 LCD
141 pagine
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso BlueWalker PowerWalker VFI 40000TP 3/3 BX. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica BlueWalker PowerWalker VFI 40000TP 3/3 BX o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso BlueWalker PowerWalker VFI 40000TP 3/3 BX descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso BlueWalker PowerWalker VFI 40000TP 3/3 BX dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo BlueWalker PowerWalker VFI 40000TP 3/3 BX
- nome del fabbricante e anno di fabbricazione BlueWalker PowerWalker VFI 40000TP 3/3 BX
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature BlueWalker PowerWalker VFI 40000TP 3/3 BX
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio BlueWalker PowerWalker VFI 40000TP 3/3 BX non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti BlueWalker PowerWalker VFI 40000TP 3/3 BX e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio BlueWalker in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche BlueWalker PowerWalker VFI 40000TP 3/3 BX, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo BlueWalker PowerWalker VFI 40000TP 3/3 BX, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso BlueWalker PowerWalker VFI 40000TP 3/3 BX. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
PowerW alker VFI 3/3 Series VFI 20000TP~40000TP 3/3 BX 380/400/415V 50/60Hz (3-phase input/output) User Guide[...]
-
Pagina 2
[...]
-
Pagina 3
EN ©2013 BlueW alker GmbH All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced (even extracts) unless permission granted. Every care has been taken to ensure the accuracy of the information contained in this manual, but no liability can be accepted for any errors or omission. The right to mak[...]
-
Pagina 4
1 . Prior to the application, please read “Safety Instructions” carefully to ensure correct and safe application. Please keep the user manual properly . 2 . During operation, attention sh ould be paid to all warning sym bols and operations should be followed strictly as required. 3 . Equipment is not supposed to be used in environment that dire[...]
-
Pagina 5
EN 3 . Replacement of accumulator batteries requires a match of same type and model with equal quantity . 4 . As accumulator batteries may contain potential electric shock and short-circuit current danger , to avoid accidents that might be thus resulted, the following warnings should be observed during battery replacement: A . Do not wear watches, [...]
-
Pagina 6
Contents Chapter 1 Brief introduction --------------------------------------- 1.1 Product introduction -------------------------------------------------- 1.2 Frequently used symbols ---------------------------------------------- 1.3 Product standard ------------------------------------------------------- 1.4 T echnical parameters and specication[...]
-
Pagina 7
1 EN Chapter 1 Brief introduction 1.1 Product introduction PowerW alker VFI 3/3 Series products are high-efciency and high-performance, double- conversion three phase input and three phase output UPS, unit capacity ranging between 20KV A-40KV A. Categorized by capacity , the products can be further divided into 20KV A, 30KV A and 40KV A. This se[...]
-
Pagina 8
2 1.3 Product standard The Series products are up to the following safety standards: The Series products are up to the following level of EMC requirement: Remark: Pr oper attention should be given to all warning symbols on the equipment and no tearing or damaging of these symbols is allowed.[...]
-
Pagina 9
3 EN Output W ire connection: three phase four wire + grounded V oltage: 380 ×(1 ± 1%) V AC or 220 ×(1 ± 1%) V AC (with balanced load) Power factor: 0.8 Frequency error: ± 8% at 50Hz (track bypass frequency input; when frequency exceeds ±8% or under the mode of battery power supply , frequency output should be ± 0.1% of the rated amount.) Ov[...]
-
Pagina 10
4 General specications Remark: when UPS has been stor ed under a temperature of 0 ℃ or has been inactive for a long time, it is suggested that prior to start-up of UPS envir onmental temperature should be br ought back to 0 ℃ or above for 2 hours. Altitude: below 1000m Storage temperature: -25 ℃~ + 55 ℃ MODEL NO Machine size(mm) L * W [...]
-
Pagina 11
5 EN Chapter 2 Exterior appearance Remark: prior to transportation make sur e of the height of the door and other obstacles standing in the passage. Refer to the following gur e for the dismantling of machine cabi - net: 1.Unpack and there should be: 2.1 Unpacking inspection 2. Check whether UPS is damaged during the process of transportation or[...]
-
Pagina 12
6 EXT .BA TTERY TEMP PROBE Fan Front view Rear view SER VICE RS232 RS485 EPO AS400 Exterior gure of VFI 20000TP 3/3 BX UPS 2.2 Exterior gure LCD panel Button LED indicator light intelligent slot Extended slot P ARALLEL[...]
-
Pagina 13
7 EN Exterior gure of VFI 30000TP 3/3 BX,VFI 40000TP 3/3 BX UPS CHGR F AN Maintenance switch Main Ⅰ Main Ⅱ( Optional kit ) Front view (without front panel) EXT .BA TTERY TEMP PROBE FA N SER VICE RS232 RS485 EPO AS400 Front view Rear view LCD panel Button LED indicator light intelligent slot Extended slot P ARALLEL[...]
-
Pagina 14
8 CHGR F AN Main Ⅰ Main Ⅱ( Optional kit ) 2.3 Panel instructions ① AC: this light and inverter light will turn “green” when UPS is powered directly by AC ; ② Inverter: this light will turn “green” when UPS is loaded through the inverter; ③ Battery: this light will turn “yellow” when UPS is powered by batteries; ④ Bypass:[...]
-
Pagina 15
9 EN ⑤ Fault: this light will turn and stay “red” with continuous warning tone being given off in case of UPS abnormal function; or ash “red” with intermittent warning tone being given off. ⑥ LCD: display UPS condition. ⑦ : Conrm/Enter; press this button to select a menu or conrm an operation. ⑧ : PageDown; press this butto[...]
-
Pagina 16
10 Chapter 3 Installation instructions 3.1 Single machine installation 1) The installation of this unit must be performed in compliance with the electrical code by professional personnel. 2) Install the UPS in a clean and stable environment that is free of vibration, dust, high humidity , ammable gas, ammable liquid or caustic substance. 3) T[...]
-
Pagina 17
11 EN for each group being168VDC-192VDC. Battery capacity and number of group can be se - lected at your option. Battery pack must be equipped with DC switch (it is suggested that selection of DC switch should be in line with installation drawing for wire connection). 9) Installation and wire connection diagram 10) Jumper list for the UPS 8) Brake [...]
-
Pagina 18
12 Remark: 1. For the Series UPS, input neural line should be dir ectly connected to input “N” termi - nal of UPS wir e connection terminal bay without AC input idle-run; 2. When single-phase curr ent exceeds 100A, switches of protective atmospher e should be equipped with ar c control devices; 3. Battery positive/negative wir e size: indicates[...]
-
Pagina 19
13 EN 1. Make sure that UPS input and output terminals are uncharged; 2. T urn off the battery switch on battery box; 3. Connect “+”, “N” and “-“ of battery to the corresponding terminal bay of UPS; 4. Use multimeter (DC V oltage) to measure the voltage of positive and negative batteries as well as positive and negative polarity . 3.3 P[...]
-
Pagina 20
14 Chapter 4 Operation 4.1 Single machine operation 1. Make sure A, B and C phase sequences are correctly connected and then supply power to UPS. 2. T urn on the switch on battery box (make sure that the “+”, “N” and “-” of terminal bay are in accordance with those on the battery box). 3. Switch on “input breaker” (Line input breake[...]
-
Pagina 21
15 EN 5)Press ▼ again to obtain the below 6)Press ▼ again to obtain the below information information 7)Press ▼ again to obtain the below 8)Press ▼ again to obtain the below information information VFI 20000TP 3/3[...]
-
Pagina 22
16 1)Switch-on picture 2)Press ENTER 3)Select “Y es, Conrm” to switch on 4)Normal Switch-on the machine Remark: when malfunction occurs, “x” will appear at the lower right corner of the pic - tur e while when warning occurs “ ” will appear at the same position (as illustrated in the below pictur e with battery mode as an example). 4.[...]
-
Pagina 23
17 EN 5. Switch-off action (press ESC to exit above picture) 1)Switch-off picture 2)If it is in single machine mode, the following will appear 3)If it is in parallel machine mode, the 4)Press ENTER following will appear 5)Battery power supply (switch off line input breaker)[...]
-
Pagina 24
18 6. Help 1) Help picture 2)Press ENTER on help picture Remark: If you intend to switch off only one set of UPS among the parallel machine sys - tem, select “single machine switch-off”; if switch-off is intended for the entir e parallel machine system, select “parallel machine switch-off”. 5)Select “Y es, Conrm” to switch of f 6)Nor[...]
-
Pagina 25
19 EN 1)Setting picture (bypass power supply) 2) Press ▼ 7. Setting action (press ESC to exit the above picture) Y ou are able to access Setting picture by using user combination (default: 1234, subject to personal modication) so as to set the following programs.[...]
-
Pagina 26
20 3)Input Password display 4)Input password and press ENTER 8. The Series is capable of DC start-up without AC input, panel display being similar to switch-on picture with AC supply . DC switch-on and off are available by following in - structions appearing in the pictures. 9. Procedures of DC switch-on: Activate DC switch-on function set under UP[...]
-
Pagina 27
21 EN 4.2 Parallel machine operation 1. Redundancy introduction N+X is currently the most reliable power supply structure, in which N indicates the mini - mum UPS number required for the total load and X is the redundant UPS number , namely , the malfunctioning UPS number that the system can simultaneously bear . The lar ger X is, the higher reliab[...]
-
Pagina 28
22 3. Operation instructions 1) Follow single machine operation instructions for general operation. 2) After switch to Line mode, all machines will jump to conversion mode; switch off: when switch-off is conducted under conversion mode, all machines will simultaneously switch off inverter and then convert to the bypass mode after the last machine c[...]
-
Pagina 29
23 EN The Series provide Intelligent Slot, Expanded Slot, P ARALLEL, EXT .BA TTER Y TEMP PROBE, AS400, EPO, RS485 and RS232 as well as SER VICE Supervising Communica - tion Interface exclusively available to PowerW alker technical personnel. 1. Intelligent slot: suitable for W ebPower card (optional) of remote supervising manage - ment, enabling yo[...]
-
Pagina 30
24 RS485 port: RS232 port:[...]
-
Pagina 31
25 EN AS400 port:[...]
-
Pagina 32
26 Chapter 6 T ransportation, Maintenance and T roubleshooting Remove UPS Make preparation for UPS relocation according to the following steps. Remark: special equipment (forklift) is needed for loading and unloading due to the heavy weight of UPS. 1. Switch off all equipments connected to UPS. 2. T urn off UPS AC switch and battery pack switch. 3.[...]
-
Pagina 33
27 EN Please refer to “Light Reference T able” of this User Manual rst and then conduct proper treatment. If problems still exist, please record UPS model, serial number as well as pur - chase date, symptom on fault, light condition, LCD malfunction or warning information. T roubleshooting Should maintenance prove necessary , the following s[...]
-
Pagina 34
28 Appendix 1 Light Reference T able Should any display or warning message excluded in the above table be found, please con - tact distributor . ● Indicator light is on ★ Indicator light ashes[...]
-
Pagina 35
[...]
-
Pagina 36
614-01720-00[...]