Bradford-White Corp 07.05.228.00 manuale d’uso
- Visualizza on-line o scarica il manuale
- 28 pagine
- 0.89 mb
Vai alla pagina of
Manuali d’uso simili
-
Water Heater
Bradford-White Corp TGHE-160E-N(X)
64 pagine 1.1 mb -
Water Heater
Bradford-White Corp M-2HE40S6DS
2 pagine 0.31 mb -
Water Heater
Bradford-White Corp Commerical 24 Volt Flue Damper series Water Heater
20 pagine 1.1 mb -
Water Heater
Bradford-White Corp S-SW2-60R 6DS
16 pagine 0.64 mb -
Water Heater
Bradford-White Corp 546-B
2 pagine 0.24 mb -
Water Heater
Bradford-White Corp MAGNUM Series Commercial Electric Booster
28 pagine 0.89 mb -
Water Heater
Bradford-White Corp LD-12UT3-1
2 pagine 0.14 mb -
Water Heater
Bradford-White Corp M1-2U6SS
2 pagine 0.33 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Bradford-White Corp 07.05.228.00. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Bradford-White Corp 07.05.228.00 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Bradford-White Corp 07.05.228.00 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Bradford-White Corp 07.05.228.00 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Bradford-White Corp 07.05.228.00
- nome del fabbricante e anno di fabbricazione Bradford-White Corp 07.05.228.00
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Bradford-White Corp 07.05.228.00
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Bradford-White Corp 07.05.228.00 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Bradford-White Corp 07.05.228.00 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Bradford-White Corp in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Bradford-White Corp 07.05.228.00, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Bradford-White Corp 07.05.228.00, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Bradford-White Corp 07.05.228.00. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
MAGNUM Series Commercial Electric Booster Inst allation and Operating Manual I&W #07.05.228.00 No opere este equipo al menos que haya leído y comprendido el contenido de este manual! Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede result ar en un serio lesión o muerte. Este manual con tie ne im port ante[...]
-
Pagina 2
i CONTENTS Form No. EBOOSTERBWM-1009 INTRODUCTION The Bradford White Magnum Series Commercial Electric Booster water heater is designed for use with commercial dishwashers to boost the temperature of the regularly available hot water , usually 1 10°–150°F (43°–66°C) up to 180°F (82°C). W ater at 180°F (82°C) can be used as sanitizing ri[...]
-
Pagina 3
IMPORT ANT SAFETY INFORMA TION Form No. EBOOSTERBWM-1009 1 ELECTRIC SHOCK HAZARD: • This unit must be inst alled by qualified, trained inst allers. Installation must conform to all local electrical and plumbing codes. Check with your local plumbing and electrical inspectors for proper procedures and codes. • T urn power OFF at disconnect switch[...]
-
Pagina 4
IMPORT ANT SAFETY INFORMA TION Form No. EBOOSTERBWM-1009 2 Unit s are equipped with a high temperature limit safety switch that will shut off power if the unit overheat s. Cont act an Authorized Service Agent if high temperature limit safety switch cannot be reset or continues to trip. Inst all booster water heater as close as possible to the comme[...]
-
Pagina 5
MODEL DESCRIPTION SPECIFICA TIONS Form No. EBOOSTERBWM-1009 3 M a g n u m S e r i e s C o m m e r ci a l E l e c t r i c B o o s te r The Magnum Series Commercial Electric Booster water heater includes a booster heater with low-water cut-off system, temperature/pr essure relief valv e, pressure reduci ng valve with buil t-i n hig h pre ssu re by pa[...]
-
Pagina 6
Model kW V olt s Phase Amp Draw Breaker or Copper Conduit L1 L2 L3 Fuse Size Wire Size Size LI663CFC 6 208 1 29 29 - 40 8 1/2" (13 mm) LI663CFD 6 208 3 14 25 14 40 8 1/2" (13 mm) LI663CFE 6 240 1 25 25 - 40 8 1/2" (13 mm) LI663CFF 6 240 3 13 22 13 30 10 1/2" (13 mm) LI663CFM 6 480 36 1 1 6 15 14 1/2" (13 mm) LI693CFC 9 208 [...]
-
Pagina 7
SPECIFICA TIONS Form No. EBOOSTERBWM-1009 5 Wire size is based on THHN wire for branch circuit protection at .91 derate factor . Circuit breakers and fused disconnects are to be mounted remote and wired by contractor . Sizes are based on the 2002 NEC table 310-16. Conduit size based on conductors plus ground wire sizing per T able C1 from Appendix [...]
-
Pagina 8
INST ALLA TION Form No. EBOOSTERBWM-1009 6 General For th e most e ff ecti ve ope rati on, in st all th e boos ter wa ter he ater as close as possible to the commercial dish machine. The location must have a solid foundation or strong table/counter construction along with being clean and dry . Adequate front clearance is required to allow for acces[...]
-
Pagina 9
INST ALLA TION Form No. EBOOSTERBWM-1009 7 Figure 4. Components Shipped with the Magnum Series Commercial Electric Booster Legs Mounting Bracket s with Hardware T emperature/Pressure Gauge T emperature/Pressure Relief V alve Plastic Leg S tainless S teel Leg A set of mounting brackets or a set of legs are supplied with each booster water heater . T[...]
-
Pagina 10
INST ALLA TION Form No. EBOOSTERBWM-1009 8 T emperature/Pressure Relief V alves For pr otec tion a gain st ex cess ive pr ess ures a nd tem pera tur es in the booster heater , install temperature/pressure protective equipment required by local codes. The temperature/pressure relief valve supplied with this booster water heater is constructe d with [...]
-
Pagina 11
INST ALLA TION Form No. EBOOSTERBWM-1009 9 Plumbing Connections Use the following procedures to connect the inlet and outlet water lines as well as inspect the system once the plumbing connections are complete. Do not connect an exp ansion t ank of any type to booster water heater lines. Use only plumbing material suit able for a minimum water temp[...]
-
Pagina 12
INST ALLA TION Form No. EBOOSTERBWM-1009 10 T emperature/Pressure Gauge T emperature/Pressure Relief V alve 150 psi (1034 kPa)/210°F (99°C) 3/4″ Union* Pressure Reducing V alve w/Bypass. Maximum 20 psi (138 kPa) flow pressure. T emperature/Pressure Gauge Outlet to dish machine Shock Absorber † Drain V alve* 3/4″ Union* Floor Drain Outlet In[...]
-
Pagina 13
INST ALLA TION Form No. EBOOSTERBWM-1009 11 DO NOT turn on power to the booster water heater until t ank has been filled with water and all air has been vented through dish machine rinse nozzle. The heating elements will burn out in seconds if operated when they are not immersed in water . Electrical — All Sizes and V olt ages General Bradfor d W[...]
-
Pagina 14
OPERA TION Form No. EBOOSTERBWM-1009 12 General Use the following procedures to operate the Magnum Series Commercial Electric Booster water heater . Read all safety messages in the Important Safety Information section before operating this equipment. DO NOT turn on power to the booster water heater until t ank has been filled with water and all air[...]
-
Pagina 15
MAINTENANCE Form No. EBOOSTERBWM-1009 13 General Bradford White Magnum Series Commercial Electric Booster water heaters are designed for maximum durability and performance, with minimum maintenance. ELECTRIC SHOCK HAZARD: • T u rn powe r OFF at di sconn ect sw itch/ circu it brea ker and allow unit to cool before performing any maintenance or cle[...]
-
Pagina 16
MAINTENANCE TROUBLESHOOTING GUIDE Form No. EBOOSTERBWM-1009 14 General ELECTRIC SHOCK HAZARD: • T urn power OFF at disconnect switch/circuit breaker and allow unit to cool before performing any maintenance or cleaning. • This unit must be serviced by qualified personnel only . Service by unqualified personnel may lead to electric shock or burn.[...]
-
Pagina 17
TROUBLESHOOTING GUIDE Form No. EBOOSTERBWM-1009 15 Symptom Probable Cause Corrective Action W ater reaches 180°F (82°C) but does not last through the entire dishwasher operation. Low incoming water temperature. Incoming water temperature must be adequate for booster size. Increase incoming water temperature. Incoming water temperature drops. Prim[...]
-
Pagina 18
TROUBLESHOOTING GUIDE Form No. EBOOSTERBWM-1009 16 Symptom Probable Cause Corrective Action W ater at dish machine is not at the proper temperature. Gauge(s) not working properly . Check temperature of water with a thermometer to be certain gauges are working correctly . If not, replace gauge(s). Thermostat set too low . Adjust or recalibrate. If t[...]
-
Pagina 19
ACCESSORIES Form No. EBOOSTERBWM-1009 17 St ainless Steel Adjust able Legs 1. Carefully place the unit on its side. Do not lay unit on the side with the control p anel. Damage to the unit could occur . 2. Thread the adjustable legs into the existing leg holes on the bottom of the unit. 3. Af ter all legs are secure, return the unit to the upright p[...]
-
Pagina 20
WIRING DIAGRAMS Form No. EBOOSTERBWM-1009 18 10-01-454 6 – 9 kW Wiring Diagram, All V oltages, Single- or Three-Phase 10-01-448 12 – 18 kW Wiring Diagram, All V oltages, Three-Phase[...]
-
Pagina 21
WIRING DIAGRAMS Form No. EBOOSTERBWM-1009 19 10-01-452 12 – 15 kW Wiring Diagram, 208 and 240 V , Single-Phase 10-01-447 18 kW Wiring Diagram, 208 and 240 V , Single-Phase[...]
-
Pagina 22
WIRING DIAGRAMS Form No. EBOOSTERBWM-1009 20 10-01-432 24 – 30 kW Wiring Diagram, 240 V , Single-Phase 10-01-433 24 – 36 kW Wiring Diagram, 208 and 240 V , Three-Phase[...]
-
Pagina 23
WIRING DIAGRAMS Form No. EBOOSTERBWM-1009 21 10-01-435 24 – 36 kW Wiring Diagram, 480 V , Three-Phase 10-01-436 36 kW Wiring Diagram, 240 V , Single-Phase[...]
-
Pagina 24
WIRING DIAGRAMS Form No. EBOOSTERBWM-1009 22 10-01-434 45 – 57 kW Wiring Diagram, 480 V , Three-Phase 10-01-437 36 – 57 kW Wiring Diagram, 208 and 240 V , Three-Phase[...]
-
Pagina 25
LIMITED COMMERCIAL W A TER HEA TER W ARRANTY Form No. EBOOSTERBWM-1009 23 WHA T DOES THIS LIMITED W ARRANTY COVER? This l imit ed war rant y cov ers bo th the t ank and comp onen t pa rt s for leakage or other m alfunction caused by d efects in ma terials and/or workmanship. It extends to the first buyer and to any subsequent owner(s) as long as th[...]
-
Pagina 26
LIMITED COMMERCIAL W A TER HEA TER W ARRANTY (CONTINUED) Form No. EBOOSTERBWM-1009 24 WHA T SHOULD YOU DO T O KEEP THE W ARRANTY IN EFFECT? T o facilitate warranty assist ance, you should: 1. Follow all instructions enclosed with the product. 2. Retain all bills of sale or receipts for proof of inst allation, etc. 3. Contact your installer , dealer[...]
-
Pagina 27
NOTES Form No. EBOOSTERBWM-1009 25[...]
-
Pagina 28
Printed in U.S.A. October 2009 Part No. 07.04.474.00 Form No. EBOOSTERBWM-1009 Ambler , P A 19002 T echnical Service 800.334.3393 Service Parts 800.538.2020 W arranty Service 800.531.21 1 1 www .bradfordwhite.com[...]