Warning: mysql_fetch_array() expects parameter 1 to be resource, boolean given in /home/newdedyk/domains/bkmanuals.com/public_html/includes/pages/manual_inc.php on line 26
Brocade Communications Systems 53-0001575-01 manuale d’uso - BKManuals

Brocade Communications Systems 53-0001575-01 manuale d’uso

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31

Vai alla pagina of

Un buon manuale d’uso

Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Brocade Communications Systems 53-0001575-01. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Brocade Communications Systems 53-0001575-01 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Brocade Communications Systems 53-0001575-01 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso Brocade Communications Systems 53-0001575-01 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Brocade Communications Systems 53-0001575-01
- nome del fabbricante e anno di fabbricazione Brocade Communications Systems 53-0001575-01
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Brocade Communications Systems 53-0001575-01
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Brocade Communications Systems 53-0001575-01 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Brocade Communications Systems 53-0001575-01 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Brocade Communications Systems in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Brocade Communications Systems 53-0001575-01, come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Brocade Communications Systems 53-0001575-01, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Brocade Communications Systems 53-0001575-01. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 1 of 31 Building and Scaling BROCADE © SAN Fabrics: Design and Best Practices Guide[...]

  • Pagina 2

    Last Updated March 29, 2001 3:18 pm BROCADE SAN Integration and Application Department 53-000 1575-01 B ROCADE Technical Note Page 2 of 31 Design and Best Practices Guide This document contains BROCADE © r ecommendations and guidelines for configuring a Storage Area Network (SAN). The document includes several reference topologies and also provide[...]

  • Pagina 3

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 3 of 31 2.0 Fabric Topologies This section explores a variety of fabric topologies and provides some specific network examples for SAN fabrics. Topologies fal l into the following general categories: • Meshed Topology-- a network of switches that has at least one link[...]

  • Pagina 4

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 4 of 31 Tier Architecture Designs • Typically three layers of switches, a host layer, core layer, and storage layer • Natural extension to star design (in some cases, Tier designs are Stars) • Core switches are used to provide connectivity between host and storage[...]

  • Pagina 5

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 5 of 31 useful when combined with a link extender that can allow from 30 to 120 kilometers distance between switch elements. There is a latency penalty for extended links that needs to considered where performance is a concern. Shorter links, lower latency -- with rough[...]

  • Pagina 6

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 6 of 31 Half of the switches are connected to form one fabric, and the other half form an identical fabric, which is completely unconnec ted to the first fabric. There is no single point of failure in either fabric which could cause the fabric to segment. This can be u [...]

  • Pagina 7

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 7 of 31 FIGURE 2. Two Core Switch, Two ISL, Star Design. The above SAN is a single fabric, resilient design. To deploy a dual fabric, resilient SAN based upon this architecture, the fol lowing SAN would be built FIGURE 3. Dual Fabric Design, Hosts and Storage connection[...]

  • Pagina 8

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 8 of 31 • Switch upgrades can take place on one SAN (firmware, hardware, both) and while this SAN is down the redundant SAN stays in operation • A switch failure in one SAN allow for failover to the redundant SAN while the failed switch is replaced. • Eliminates t[...]

  • Pagina 9

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 9 of 31 2.4 D UA L S W I T C H H I GH A VA I L A B I L I T Y C O N F I G UR A T I O N - R E DUN DAN T F A B R I C FIGURE 4. Two Fabrics -- Simplest Redundant Fabric Configuration H SW D H SW • Can use multiple hosts sharing single disk device, with redundant paths in [...]

  • Pagina 10

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 10 of 31 2.5 T W O S W I T C H F A B R I C F O R M I RR O R I N G AN D D I S A S TE R T O L E R ANC E FIGURE 5. Extended Fabric Example H SW D H SW • Sample configuration showing only two hosts and two storage devices, larger configurations can be deployed • This ex[...]

  • Pagina 11

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 11 of 31 2.6 H I GH L Y A V A I L A BL E S M A LL F A B R I C C O N F I G URA T I O N FIGURE 6. HIghly Available Small Fabric SW SW • In this design, any switch can fail and there will still be an alternative path to the host and storage devices. [Assumes hosts/storag[...]

  • Pagina 12

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 12 of 31 2.7 SAN B U I L D I N G B L O C K - M E S H E D F A B R I C C O N S I S T I N G O F T W O S T AR T O P O L OG I E S C O NN E C T E D B Y A M E S H FIGURE 7. SAN Building Block showing expansion to 17 switch Mesh Fabric • An atomic building block of 8 switches[...]

  • Pagina 13

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 13 of 31 2.8 S T A R T O P O L OG Y D E S I G N In the traditional data networking world, star topology network has a core of networking equipment (hubs, switches, and routers) with other equipment radiating out from this. A star topology SAN is fundamentally the same: [...]

  • Pagina 14

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 14 of 31 FIGURE 10. Two Switch Core Star SAN Design The strengths of this design are numerous. This provides lowest hop count design, uses the fewest switches for the given port co unt, has the best and easiest to analyze performance characteristics, and is the simplest[...]

  • Pagina 15

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 15 of 31 FIGURE 11. Star Topologies shown with 2x16 port switch at the core and with 4x16 port switch at the core Brocade has tested and validate star SAN designs today with our SilkWorm 2800 16 port switch. The two core switch topology shown in Figure 5 is a very good [...]

  • Pagina 16

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 16 of 31 FIGURE 12. Star Topologies Possible with 2 switch cores 2.9 T I E R D E S I G N[...]

  • Pagina 17

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 17 of 31 Three Tier designs in general allow for higher port count fabrics over Star designs (using the same switch building blocks) but can add additional hops to the design. A middle (core) set of switches can be used to provide connectivity between an upper and lower[...]

  • Pagina 18

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 18 of 31 FIGURE 14. MUlti Tier SAN Design across an Extended Link Depicted in the next diagram is a 20 switch fabric, three tier, with 4 switches at the core. This fabric offers 2 hops from sour ce to destina- tions, with multiple equal cost paths between devices allowi[...]

  • Pagina 19

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 19 of 31 FIGURE 15. Twenty Switch Three Tier Design (also a Star configuration) • 192 user ports total; total of 64 ISLs • Multiple equal cost paths between end nodes via a redundant switch • Maximum of two hops between devices • Any to any connectivity however [...]

  • Pagina 20

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 20 of 31 2.9.1 S U MM A RY A variety of SAN designs topologies and port counts can be deployed today using Brocade switch. The Fabric Operating System prov ides for auto-discovery and configuration of the SAN as devices are added and new switches included in an existing[...]

  • Pagina 21

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 21 of 31 3.0 Additional Considerations in Fabric Design and Implementation 3.1 F A B R I C B R I N G U P A large (greater than 8) switch fabric will require care and planning on initial power up and for expanding switch elements. Bro- cade has developed an extensive pla[...]

  • Pagina 22

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 22 of 31 FIGURE 17. Valid and Invalid Configurations using Inter Switch Links 3.3 C A BL I N G AND M E D I A I N T E R F A C E S Fibre channel supports several cable and optical media interface options. • The shortest supported optical cable length is 2 meters. Using [...]

  • Pagina 23

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 23 of 31 for wiring components that do not need to be a long distance from the switch. Copper connections tend to be less expensive. If c ost is not a driver, designing a solution with all optical media will provide for greater flexibility in future system upgrades and [...]

  • Pagina 24

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 24 of 31 The total size of a switch fabric is related to a number of factors that can affect overall performance. Some factors include: • Total nodes, entries in the name space. Name space table management as devices in the fabric change can effect overall fabric perf[...]

  • Pagina 25

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 25 of 31 of Fibre Channel is that data is transferred based on buffer credits assigned to ports and sending and receiving devices manage the credits so that there is never an overrun of data in the switch. Blocking is also called over-subscription -- where multiple init[...]

  • Pagina 26

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 26 of 31 fabric using IP over fibre channel protocol across switch links, thus reducing the need for a large switch management network. T his config- uration requires the primary switch with the Ethernet connection to be configured as the gateway switch for the Fibre Ch[...]

  • Pagina 27

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 27 of 31 width of 100 MBytes/sec. Thirty disks attached to a hub on a single physical loop will not perform as well as 5 disks attached t o 6 switch QuickLoop ports. Other advantages are: • Loop tenancies can occur in parallel on different looplets. A loop tenancy occ[...]

  • Pagina 28

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 28 of 31 4.0 G lossar y This glossary provides definitions for the fibre channel and switch terminology used in BROCADE guide . TABLE 1. Glossary of Fibre Channel and SAN Design Terminology Term Definition Address Identifier Value used to identify source or destination [...]

  • Pagina 29

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 29 of 31 Frame Fibre channel structure used to transmit data. Consists of start-of-frame delimiter, header, any optional headers, data payload, cyclic redundancy check (CRC), and end-of-frame delimiter. There are two types: data frames and link con- trol frames. Similar[...]

  • Pagina 30

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 30 of 31 Topology As applies to fibre channel, the structure of the fibre channel network and the resulting possible communication paths. There are three fibre channel topologies: point-to-point, fabric, and arbitrated loop. Zone Set of hosts and devices attached to sam[...]

  • Pagina 31

    SAN Design: March 29, 2001 3:18 pm 53-000 1575-01 B ROCADE Technical Note Page: 31 of 31 Copyright IMPORTANT NOTICE This document is the property of BROCADE. It is intended solely as an aid for installing and configuring Storage Area Networks c onstructed with BROCADE switches. This document does not provide a warranty to any BROCADE software, equi[...]