Warning: mysql_fetch_array() expects parameter 1 to be resource, boolean given in /home/newdedyk/domains/bkmanuals.com/public_html/includes/pages/manual_inc.php on line 26
Burnham Indirect - Fired Water Heater AL SL manuale d’uso - BKManuals

Burnham Indirect - Fired Water Heater AL SL manuale d’uso

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Vai alla pagina of

Un buon manuale d’uso

Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Burnham Indirect - Fired Water Heater AL SL. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Burnham Indirect - Fired Water Heater AL SL o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Burnham Indirect - Fired Water Heater AL SL descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso Burnham Indirect - Fired Water Heater AL SL dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Burnham Indirect - Fired Water Heater AL SL
- nome del fabbricante e anno di fabbricazione Burnham Indirect - Fired Water Heater AL SL
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Burnham Indirect - Fired Water Heater AL SL
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Burnham Indirect - Fired Water Heater AL SL non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Burnham Indirect - Fired Water Heater AL SL e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Burnham in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Burnham Indirect - Fired Water Heater AL SL, come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Burnham Indirect - Fired Water Heater AL SL, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Burnham Indirect - Fired Water Heater AL SL. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    1 INST ALLA TION, OPERA TING AND SER VICE INSTRUCTIONS FOR Alliance SL ™ Indirect - Fired W ater Heater For service or repairs to the water heater , call your heating contractor . When seeking informa- tion on the water heater , provide Model Number and Serial Number as shown on Rating Label. Model Number AL SL Serial Number Installation Date Hea[...]

  • Pagina 2

    2 PLEASE READ INSTRUCTIONS CAREFULL Y BEFORE INST ALLING W A TER HEA TER U.S Boiler Company , Inc. – Burnham Hydronics (herein called the Company) intends that this Alliance SL™ Indirect-Fired W ater Heater be used as a separate zone to a heating system boiler . This appliance is designed to heat water by circulating water from the boiler throu[...]

  • Pagina 3

    3 INDEX General Information ..................................................................................................................... 2 Specications & Ratings .............................................................................................................. 2 Installation Guidelines ...................................[...]

  • Pagina 4

    4 A. INSPECTING AND PREP ARING THE W A TER HEA TER  q AL27SL thru AL70SL - Remove the cardboard box, which comes packaged with the heater . It should contain the following: TPI thermostat, T&P valve and a “T ee”, foamed lid and screws. q AL1 19SL - Remove the cardboard boxes, which come packaged with the heater . One box should con[...]

  • Pagina 5

    5 valve must be marked with maximum set pressure not to exceed the marked maximum allowable working pressure of the water heater (150psi). Install the valve into the opening provided and marked for this purpose in the water heater , and orient it or provide the tubing so that any discharge from the valve will exit only within 6 inches above, or at [...]

  • Pagina 6

    6  q Do not apply heat directly to the cold-water inlet as it is made of plastic and will melt. G. BOILER SUPPL Y CONNECTIONS  q W ARNING: Boiler temperature must be controlled by the boiler high limit not to exceed 200°. Failure to do so will create a hazardous installation and void the applicable limited warranties.  q All wate[...]

  • Pagina 7

    7  q Run all 24V AC wiring thru the square notch on bottom of TPI case. (See TPI Diagram 3)  q Incoming 24V AC power must be connected to 24V AC connectors on the bottom right corner of TPI control. (See TPI Diagram 3)  q Connect control wiring to PUMP/TT normally open relay connections (rated for both 24V and 1 10V wiring) on the[...]

  • Pagina 8

    8  q Do not apply heat to cold inlet.  q If there is a check valve (sometimes in water meter), backow preventer or pressure-reducing valve, install an adequate size expansion tank. G. FILLING THE HEA TER  q Completely ll heater .  q W ater connections completed and free of leaks.  q Check for proper installation [...]

  • Pagina 9

    9 W A TER TEMPERA TURE CONTROLS A periodic inspection of the operating controls, heat exchanger and wiring should be made by qualied ser - vice personnel. T emperature of the water should be tested periodically at the faucet to be sure thermostat is working properly . TEMPERA TURE ADJUSTMENT The TPI comes with a factory set temperature setting o[...]

  • Pagina 10

    10 TPI CONTROL - DIAGRAM 1 Indicating Light T emperature Adjust Differential Adjust TPI CONTROL - DIAGRAM 2 Screw A[...]

  • Pagina 11

    1 1 TPI CONTROL - DIAGRAM 3 Outgoing 24V wires to relay or zone valve Incoming 24V power connection Outgoing 1 10V wires to circulator Chase Nipple Conduit Incoming 24V power connections NOTE: Use proper conduit and chase nipple[...]

  • Pagina 12

    12 FIGURE 1 - Installation Using Zone V alves Installation Diagram Using Zone V alves FIGURE 2 - Installation Using Circulator Installation Diagram Using Separate Circulator[...]

  • Pagina 13

    13 FIGURE 3 - Coil Detail & T ightening Sequence Bolt Steel W asher Coil Plate Plastic O-Ring Housing T ank Flange ‘L ’ Nut Small outside O-ring Large inside O-ring Proper T ightening Sequence for T op Mount Coil CAUTION: Does not require excessive force to seal properly . 3 2 1 6 4 7 2 5 3 8 1 Incorrect Correct Note: Same as car tire lugs[...]

  • Pagina 14

    14 Low V oltage 120 V olts L1 Hot 120 V olts L2 Neutral Circula tor 24v T emperature Differential Pump/TT 24v LED flashing green = calling for heat solid green = at temperature red = error 20° 15° 10° 5° 160° 150° 140° 130° 120° 1 10° Probe Switched Hot ® ® T T Switching Relay T ransformer Thermostat Burner T V W T Z C1 C2 L1 L2 B1 B2 1[...]

  • Pagina 15

    15 Zone V alve Wiring Diagrams Wiring for 3 W ire Zone V alve L o w V oltage 120 V olts 120v 24v B oiler C onnec tions T 1 T 2 3 H ot N eutr al Z one V alv e 120v 24v T o B oiler C onnec tions /C ir cula t or H ot N eutr al 4 W ir e Z one V alv e M ot or E nd S wit ch T T T emperature Differential P ump/T T 24v LED flashing green = calling for heat[...]

  • Pagina 16

    16 Switching relay Wiring Diagrams Switching Relay SR-502 or SR-503 Switching Relay R8845U or SR 501[...]

  • Pagina 17

    17 Switching relay Wiring Diagrams (con’t) Switching Relay SR-504 with Priority Option L o w V oltage 120 V olts FUSE 1 AMP C OM / 24 V A C FOUR Z ONE SWIT CHING REL A Y WITH OPTIONAL PRIORIT Y Z ONE 1 Z ONE 2 Z ONE 3 Z ONE 4 Z ONE 4 PRIORIT Y ON OFF Z ONE 1 Z ONE 2 Z ONE 3 Z ONE 4 PO WER 120 V OL T CIR CUL A T ORS X X END SWIT CH Z C ZR INPUT SR[...]

  • Pagina 18

    18 HOW T O OBT AIN SER VICE ASSIST ANCE U.S. Boiler Company , Inc. – Burnham Hydronics does not have a service department or personnel to ser- vice your heater in the eld. A qualied installer or service technician must do all service work. Therefore, if you have any questions about your new water heater concerning service adjustment, repair[...]

  • Pagina 19

    19 Alliance SL™ Indirect-Fired W ater Heater 10/2/1 LIMITED W ARRANTY T en Y ear Limited T ank Replacement W arranty T wo Y ear Limited T ank Replacement Labor Allowance One Y ear Limited Parts W arranty U.S. Boiler Company , Inc. – Burnham Hydronics, (hereinafter called the company) offers the following Lim- ited T ank Replacement W arranty , [...]

  • Pagina 20

    20 ONE (1) YEAR LIMITED P ARTS W ARRANTY DURA TION: The warranty is effective for one (1) year beginning with the date of original purchase. This warranty shall begin from the date of manufacture as indicated by the serial number . COVERAGE: The warranty covers any component part of the Alliance SL™ water heater proven to be defective in workmans[...]

  • Pagina 21

    21 MODEL & SERIAL NUMBER INFORMA TION The following information should be noted At time of installation and retained for Future reference. Model No. Serial No. Date Installed Dealer ’s Name Address City State Zip U.S. Boiler Company , Inc., – P .O. Box 3079 – Lancaster , P A 17604 www .burnham.com[...]

  • Pagina 22

    22 NOTES[...]

  • Pagina 23

    23 NOTES[...]

  • Pagina 24

    24 Optional Lifetime W arranty Registration Card A vailable to Residential, Single Family Homes Only Y es, I wish to purchase the Optional Lifetime W arranty! DA TE _____________________________________________________________________ PURCHASER’S NAME _______________________________________________________ HOME ADDRESS ___________________________[...]