Cisco Intelligent Gigabit Ethernet Switch Module manuale d’uso
- Visualizza on-line o scarica il manuale
- 62 pagine
- 0.18 mb
Vai alla pagina of
Manuali d’uso simili
-
Switch
Cisco Cisco Catalyst 3750E-48PD-F
33 pagine 0.77 mb -
Switch
Cisco 6503
19 pagine 0.64 mb -
Switch
Cisco Catalyst 3550
33 pagine 0.78 mb -
Switch
Cisco Intelligent Gigabit Ethernet Switch Module
62 pagine 0.18 mb -
Switch
Cisco Network Analysis Module 6000
78 pagine 0.45 mb -
Switch
Cisco MGC Node Manager
38 pagine 7.51 mb -
Switch
Cisco 3032
34 pagine 0.33 mb -
Switch
Cisco SR224G
28 pagine 8.8 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Cisco Intelligent Gigabit Ethernet Switch Module. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Cisco Intelligent Gigabit Ethernet Switch Module o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Cisco Intelligent Gigabit Ethernet Switch Module descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Cisco Intelligent Gigabit Ethernet Switch Module dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Cisco Intelligent Gigabit Ethernet Switch Module
- nome del fabbricante e anno di fabbricazione Cisco Intelligent Gigabit Ethernet Switch Module
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Cisco Intelligent Gigabit Ethernet Switch Module
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Cisco Intelligent Gigabit Ethernet Switch Module non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Cisco Intelligent Gigabit Ethernet Switch Module e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Cisco in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Cisco Intelligent Gigabit Ethernet Switch Module, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Cisco Intelligent Gigabit Ethernet Switch Module, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Cisco Intelligent Gigabit Ethernet Switch Module. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
IBM E Rs e rv e r Cisco Systems Inte lligent Gigabi t Ether net Switch Module f or the IBM E ser v er BladeCenter System Message Guide Cisco IOS R eleas e 12.1 (14)A Y[...]
-
Pagina 2
Note: Bef ore using this inf or mation and the pro duc t it su ppo rts, read th e g enera l i nf or mation i n Ap pen dix B .“Getting hel p and t echnica l assist ance” and Append ix C .“Notices”. 12 1 First Edition (J une 2004) 2 © Copyright In ternationa l Business Machines Corpo ration 2004. All rights re served. US Government Users R e[...]
-
Pagina 3
© Copyright IBM Corp. 2004 1 Contents Prefac e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 A udienc e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Pur pose . . . . . . . . . . . . . . . . . . . . [...]
-
Pagina 4
2 BookTitle change in s pecial and import[...]
-
Pagina 5
© Copyright IBM Corp. 2004 3 Preface A u dience This g uide is for the netwo rking professional m anaging th e Cisco S ystems Int elligent Gigabi t Ether net Sw itch Module, hereafter referred to as the switch . Before using this guide, you should hav e ex per ience wor king with the switch and it s sof tware f eatures. Purpos e This g uide desc r[...]
-
Pagina 6
4 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM E server BladeCenter System Mes sage Guide install ing, conf iguring , or upgradin g the switch, refer to the re lease notes for the late st inf or mat ion. • Cisco S ystems Inte lligent Gi gabit Ethe rn et Switch Module for the IBM eS er ver BladeCen ter System Command Refere[...]
-
Pagina 7
Preface 5 — How to inst all the ma nagement m odule — How to configur e and use th e manag ement modu le • BladeCen ter HS20 I nstallati on and User ’ s Gu ide (for each blade se rver typ e) These doc uments are i n PDF on the IBM Blad eCenter Docu mentation C D . Each provides g eneral inform ation abou t a blade ser ver , i ncludin g: —[...]
-
Pagina 8
6 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM E server BladeCenter System Mes sage Guide[...]
-
Pagina 9
© Copyright IBM Corp. 2004 7 Chapter 1. System Message Over vie w This g uide desc ribes the switch-speci fic syste m messa ges. During operation, t he system software sen ds these mes sages t o the consol e (and, op tionally , to a loggi ng ser ver on another system) . Not all s ystem mess ages in dicate proble ms with your system . Some mes sage[...]
-
Pagina 10
8 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM E server BladeCenter System Mes sage Guide • SEVERITY is a si ngle-digi t code from 0 to 7 that r eflects the sev erity of the conditi on. The lower the numb er , the more se riou s the si tuation. Ta b l e 2 lists t he message se verity levels. • MNEMONIC is a code th at un[...]
-
Pagina 11
Chapter 1. System Message O verview 9 This is a sample s ystem messa ge: %EC-5-UNBUNDLE:Interface Gi0/2 left the port-channel Po2 The messa ges in Ch apter 2 “Me ssage and Re cov er y Procedur es, ” are de scrib ed in alphabeti cal order by facility cod e with the m ost sev ere (lowest number) errors descr ibed fir st. Err or Messa ge T racebac[...]
-
Pagina 12
10 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide[...]
-
Pagina 13
© Copyright IBM Corp. 2004 11 Chapter 2. Message a nd Recovery Pr ocedures This cha pter desc ribes the switch system messages in alp habetical o rder by f acility . Within e ach facility , the me ssages are listed b y sev erity le vels 0 to 7; 0 is the highest sev erity le v el, and 7 is the l owest se v er ity lev el. Each m essage i s f ollowed[...]
-
Pagina 14
12 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide CIGESM Messages This section contains the Cisco Sy stems Intelligent Gigabit Ethernet Switch Module (CIGESM) messages. PLA TFORM_CIGESM-2-O VER_THERMAL_THRESH2: Th e Switch Mod ule has excee ded its sec ond thermal thresho ld. Explan[...]
-
Pagina 15
Chapter 2. Message and Recovery Pr ocedures 13 PLA TF ORM_CIGESM-5-DISABLE_EXTERN: Re quest fr om Ma nagement M odule: disa ble all e x ternal ethernet ports gi0/ 17 - 20 . Explanation This message means that the switch received a request from the management module to shut down ports 17 to 20. Response No action is required. PLA TFORM_CIGESM-5-DISA[...]
-
Pagina 16
14 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide PLA T FORM_CIGESM-5-UNDR_THERMAL_T HRESH1: The Switch Module has reco vered fr om fir st thermal thresho ld. Explanation This message means that the s witch tem perature no longer e xceeds the first ther mal threshold of 167°F (75°[...]
-
Pagina 17
Chapter 2. Message and Recovery Pr ocedures 15 CMP Messages This section contains the Cluster Membership Protocol (CMP) messages. CMP-5-ADD: The Devic e is added to the cl uster (Cluster Name: [chars] , CMDR IP Ad dress [inet] ). Explanation This message means that the de vice is added to the cluster . [ chars] is the cluster name, and [inet] is th[...]
-
Pagina 18
16 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide DO T1X Messages This section contains the 802.1X authorization messages. DO T1X_MOD-3 -NULLPTR: Unexpecte d null poi nter in [chars ] at [dec] . Explanation This message means that an internal software error occurred. [chars] is the [...]
-
Pagina 19
Chapter 2. Message and Recovery Pr ocedures 17 DTP Messages This section contains the Dynamic T runking Protocol (DTP) messages. DTP-4-MEM_ UNA V AIL: Memory was not a v ailable to perf orm the trunk negotiatio n action. Explanation This message means that the system is unab le to negotiate trunks because of a lack of memor y . Response Reduce othe[...]
-
Pagina 20
18 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide DTP-5-TR UNKPOR T ON: P ort [chars] has becom e [chars] trunk. Explanation This message means that the interf ace changed from an access to a tr unk. The first [chars] is the interf ace , and the second [chars] is the encapsulation. [...]
-
Pagina 21
Chapter 2. Message and Recovery Pr ocedures 19 EC-5-CANNO T_BUNDLE_ QOS: Remo ved [char s] fr om port channel because a Qo S policy canno t be supported acro ss m ultiple DFC c ard s. Explanation This message means the specified por t cannot join the por t channel because the QoS policy attached to the por t channel cannot suppor t the multiple Dis[...]
-
Pagina 22
20 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide EC-5-L3DONTBNDL1: [chars ] suspended : P AgP not ena bled on the remote p ort. Explanation This message means that P or t Aggregation Protocol (P AgP) is enabled on a La y er 3 interf ace , but the r emote por t does not hav e P AgP [...]
-
Pagina 23
Chapter 2. Message and Recovery Pr ocedures 21 EC-5-NOP A G P: Inv alid EC mode. P AgP not enabled. Explanation This message means that P A gP is not included in the IOS image and that the EtherChannel mode cannot be set to desirab le or auto . Response Obtain an image wi th P A gP included, or set the mode to on b y using the c hannel- gr oup chan[...]
-
Pagina 24
22 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide ETHCNTR-3-LOO P_B A CK_DETECTED:, Lo op-bac k detect ed on [chars ] . The port is f or ced to linkdo w n. Explanation This message means that t he loop-bac k condi tion might be caused by a balun cable being accidentally connected to[...]
-
Pagina 25
Chapter 2. Message and Recovery Pr ocedures 23 PLA TFORM_CA T2950-3-MEM_ COPY_F AILURE: In v alid cop y [dec ] fo r t a bl e [chars] . Explanation This message means that there was an attempt to read or write an inv alid copy of the s witch internal memor y . [dec] is the inv alid copy number f or the table , and [chars] is the name of the ASIC mem[...]
-
Pagina 26
24 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide PLA TFORM_ CA T2950-3-MEM_WRITE_F AILURE: Write memo ry failed for memory [c hars] at inde x [dec] . Explanation This message means that an attempt to write to a location in the internal chip memor y f ailed, which might occur becaus[...]
-
Pagina 27
Chapter 2. Message and Recovery Pr ocedures 25 PLA TFORM_CA T2950-3-REG_READ _F AILUR E: Register re ad faile d for [chars] in [chars] Explanation This message means that t he register r ead f ailed for register [char s] in [chars ] . An at temp t to read a v alid location in the internal chip regi ster f ailed. This could be due to a hardwar e def[...]
-
Pagina 28
26 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide PLA TFORM_CA T29 50-3-SYSTEM_I NFO_F A ILURE: The bo ard inf ormation co uld not be read co rr ectly , initializ ation failed. Explanation This message means that, during switch driv er initialization, there was a f ailure to read th[...]
-
Pagina 29
Chapter 2. Message and Recovery Pr ocedures 27 PM-3-INTERNALERROR: P ort Ma nager Internal Software Error [cha rs] : [chars] : [dec] : [c hars] Explanation This message means an internal software error occurred in the IOS P or t Manager . The arguments prov ide details about the f ailure that technical suppor t can analyze. Response Find out mo re [...]
-
Pagina 30
28 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide PM-4-B A D_COOKIE: [char s ] was dete cted. Explanation This message means that the por t manager detected an in v alid request. [chars] is the inv al id request. Response Find out mo re about the error by usin g the sho w tech- supp[...]
-
Pagina 31
Chapter 2. Message and Recovery Pr ocedures 29 PM-4-B A D_VLAN_ID: An in v alid vlan id ( [dec ] ) was detecte d. Explanation This message means that the por t manager detected an inva lid request. [dec] is the V LAN ID . Response Find out mo re about the error by usin g the sho w tech-s upp ort privil eged EXEC co mmand and by cop ying the error m[...]
-
Pagina 32
30 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide PM-4-INT_F AILUP: [chars] fa iled to come up. No internal VLAN av ailab le. Explanation This message means that the port manager failed to allocate an inter nal VLAN, and the interf ace cannot come up. [chars] is the interf ace name.[...]
-
Pagina 33
Chapter 2. Message and Recovery Pr ocedures 31 PM-4-T OO_MANY_APP: Applic ation ' [c hars] ' exceed ed r egist rat ion limit . Explanation This message means that the por t manager detected an in v alid request. [chars] is the application. Response Find out mo re about the error by usin g the sho w tech-s upp ort privil eged EXEC co mmand[...]
-
Pagina 34
32 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide SP AN-3-UNKN_ERR: An internal error oc curred during a SP AN operation. Explanation This message means that SP AN detected an error in its internal operation. Response The error might be transient. T r y the SP AN operation again. If[...]
-
Pagina 35
Chapter 2. Message and Recovery Pr ocedures 33 SP ANTREE-2-CHNL_MISCFG: Detec ted loop due to ether c hannel m isconfiguratio n of [chars ] [chars] Explanation This message means that a loop that caused the misconfiguration of a channel group has been detected. An e xample of such a misconfigur ation would be when the por ts on one side of the Ethe[...]
-
Pagina 36
34 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide SP ANTREE-2-PVSTSIM_F AIL: Superior PVST BPDU rece ived on VL AN [dec] port [ch ars] , c laiming r oot [dec] : [enet] . In voking roo t guar d to bloc k the port. Explanation This message means that when a per- VLAN spanning-tree plu[...]
-
Pagina 37
Chapter 2. Message and Recovery Pr ocedures 35 SP ANTREE-2-ROO TGU ARD_BLOCK: Root guar d bloc king port [chars] on [chars] . Explanation This message means that on the listed interf ace a BPDU was receiv ed that adv er tises a superior spanning-tree root bridge (lower bridge ID , low e r path cost, and so f or th) than that in use. The interf ace [...]
-
Pagina 38
36 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide This is performed b y the STP subsystem at system initialization because the maximum number of ports on a par ticular platform does not c hange . The first [dec] is the n umber of bits f or the por t number , and the second and third[...]
-
Pagina 39
Chapter 2. Message and Recovery Pr ocedures 37 SP ANTREE-7-BLOCK-PORT -TYPE: Blocking [chars ] on [ch ars] . Incon sistent port type. Explanation This message means that the listed interf ac e is being held in the spanning-tree bloc king state until the port-type inconsistency is reso lv ed. The first [chars] is the interf a ce, and the second [cha[...]
-
Pagina 40
38 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide SP ANTREE_F AST M essa ges This section contains the spanni ng-tree f ast-conv ergence message. SP ANTREE_F AST -7-PORT_FWD_ UPLINK: [chars] [chars ] mo ved to Forwar ding (UplinkF ast). Explanation This message means that the listed[...]
-
Pagina 41
Chapter 2. Message and Recovery Pr ocedures 39 SW_VLAN Messages This section contains the VLAN manager messages. The VLAN manager receiv es inf or mation from the VTP and enab les the proper VLAN membership on all interf aces through the port manager . SW_VLAN-3-VLAN_PM_NO TIFICA TION_F AILURE: VLAN Manager synchr onization failure with P ort Manag[...]
-
Pagina 42
40 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide SW_VLAN-4-B AD_ VLAN_CONFIGURA TION_FILE: VLAN configuration file con tained incorrect verification word: [hex] . Explanation This message means that the VLAN configuration file read b y the VLAN manager did not begin with the correc[...]
-
Pagina 43
Chapter 2. Message and Recovery Pr ocedures 41 SW_VLAN-4-EXT_VLAN_INTERNAL_ERR OR : Extended VLAN ma nager received an internal error [dec] fr om [chars] : [chars] . Explanation This message means that an une xpected error code w as receiv ed by the VLAN manager from the e xtended-range VLAN configuration software . [dec] is the er ror code. The fi[...]
-
Pagina 44
42 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide SW_VLAN-4-ST ARTUP_EX T_VLAN_CONFIG_FILE_F AILED: Failed to configure e x tended range VLAN fr om startup-config. Err or [chars] . Explanation This message means that the VLAN softw are f ailed to use an e xtended-range VLAN configur[...]
-
Pagina 45
Chapter 2. Message and Recovery Pr ocedures 43 SW_VLAN-4-VTP_USER_NO TIFICA TION: VTP protocol u ser notificatio n: [char s] . Explanation This message means that the VTP code enc ountered an un usual di agnostic situation. [chars] is a descr iption of the situation. Response Find out mo re about the error by usin g the sho w tech-s upp ort privil [...]
-
Pagina 46
44 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide UDLD-3-UDLD_INTERNAL_IF_ERR OR: UDLD internal err or , interface [cha rs] : [chars] . Explanation This message means that a softw are check f ailed dur ing UDLD processing. The first [chars] is the interf ace, and the second [chars] [...]
-
Pagina 47
Chapter 2. Message and Recovery Pr ocedures 45 UF AST_MCAST_SW -4-MEM_NO T_A V AILABLE: No memory is a vail able for tr ansmitting UplinkF ast packets o n Vlan [dec ] . Explanation This message means that no memor y is availab le f or sending UplinkF ast pac kets on VLAN [dec] . [dec] is the VLAN number . Response Reduce other system activity to re[...]
-
Pagina 48
46 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide[...]
-
Pagina 49
© Copyright IBM Corp. 2004 47 Appendix A. Secu rity and QoS Configuration Messages This appe ndix des cribes the switch error m essages f or confi guring network secur ity with acces s contro l lists (ACLs) and for configur ing quali ty of ser vice ( QoS). In Ta b l e 4 , Access C ontrol P arameters ( A CPs) are r ef erred to as masks. F or more i[...]
-
Pagina 50
48 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide %Error:System Defined ACEs of TCP/UDP and IP cannot exist together in access-group within a class-map. Check class-map :[class-map name] This error mess age means that a co mbination of Lay er 3 syst em-defined a ccess co ntrol ent r[...]
-
Pagina 51
Appendix A. Security and QoS Configuration Messages 49 %Error:Invalid rule This error messa ge means tha t the hardware had a p roblem programming t he resource. Re-ente r the comma nd that you had e ntered before receiv ing the er ror message. If the mes sage rec urs, find out more abou t the error by using the show tech-sup port p rivil eged EXE [...]
-
Pagina 52
50 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide %Error:No free masks available This error mess age means that there ar e no fre e masks av ailable f or the user . Y ou mus t use one of the user-defi ned mask s that is al ready config ured. As an alter native, you can free up one o[...]
-
Pagina 53
Appendix A. Security and QoS Configuration Messages 51 %Error:FAILURE to reinsert old ACL, errcode=XX This error mess age means that a har dware f ailur e has occurr ed. Dele te the acces s group , and re-en ter the c ommand that you had enter ed before rece iving the error me ssage. If the mes sage rec urs, find out more abou t the error by using [...]
-
Pagina 54
52 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide %Error:Policer Configuration Incorrect for this interface. Check the policer rate in policy-map :[policy-map name], class-map :[class-map name]. Please choose either [lower rate] or [upper rate] (bits per second) as the policer rate [...]
-
Pagina 55
© Copyright IBM Corp. 2004 53 Appendix B. Gett ing help and technical ass istance If you need hel p , ser vice, or techn ical as sistance o r just want mo re informati on about IBM prod ucts, you will find a wi de variety of so urces available from I BM to assist you. This a ppendix con tains infor mation ab out where t o go for additional inf orm[...]
-
Pagina 56
54 BookTitle change in special and import Software service and suppor t Through IB M Suppor t Lin e, y ou can g et telephon e assistan ce, f or a fee , with usa ge, configura tion, and s oftware problems wit h BladeCe nter and x Serie s ser vers, IntelliS tation workstati ons, and appli ances. For inf orm ation abou t which pr oducts ar e suppor te[...]
-
Pagina 57
© Copyright IBM Corp. 2004 55 Appendix C. N otices This infor matio n was de veloped for products a nd ser vice s offered in the U.S .A. IBM may not offer the produc ts, ser vices, or features dis cussed in this docum ent in other co untri es. Consult your lo cal IBM re presenta tive f or informat ion on the p roducts and ser v ices curre ntly ava[...]
-
Pagina 58
56 BookTitle change in special and import T radema rks The f oll owing ter ms are trademar ks of Inter nationa l Business Ma chines Cor poration in the United States, other countri es, or both: Cisco, Cisco IOS, Cisco Sy stems, the Cis co Systems logo , Cataly st, EtherC hannel, IOS, IP/TV , Pac ket, and SwitchPr obe are re gistered tradem arks o f[...]
-
Pagina 59
57 Index Numerics 802.1X aut henticati on message s 16 see DOT 1X messag es A abbrevi ations char , var iabl e fi eld 8 chars, variab le field 8 dec, vari able field 8 enet, var iable field 8 hex, vari able field 8 inet, var iable fiel d 8 access contro l list m essages See AC L messages ACL me ssages 47 applica tion-sp ecific inte grated c ircuit [...]
-
Pagina 60
58 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide Ethe rne t con tro ller 21 hardwar e MAC addres s table mana ger 22 LACP 18 MAC addr ess table m anager 22 PAgP 18 per-VLAN sp anni ng -tre e 38 PLATFORM_CA TALYST2950 26 port mana ger 26 port secur ity 31 QoS 47 secu rity 47 SPAN 31[...]
-
Pagina 61
[...]
-
Pagina 62
IBM@ P art Number : 2 5K8409[...]